Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Sensors (Basel) ; 24(17)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39275547

RESUMO

Prevalence estimates of Parkinson's disease (PD)-the fastest-growing neurodegenerative disease-are generally underestimated due to issues surrounding diagnostic accuracy, symptomatic undiagnosed cases, suboptimal prodromal monitoring, and limited screening access. Remotely monitored wearable devices and sensors provide precise, objective, and frequent measures of motor and non-motor symptoms. Here, we used consumer-grade wearable device and sensor data from the WATCH-PD study to develop a PD screening tool aimed at eliminating the gap between patient symptoms and diagnosis. Early-stage PD patients (n = 82) and age-matched comparison participants (n = 50) completed a multidomain assessment battery during a one-year longitudinal multicenter study. Using disease- and behavior-relevant feature engineering and multivariate machine learning modeling of early-stage PD status, we developed a highly accurate (92.3%), sensitive (90.0%), and specific (100%) random forest classification model (AUC = 0.92) that performed well across environmental and platform contexts. These findings provide robust support for further exploration of consumer-grade wearable devices and sensors for global population-wide PD screening and surveillance.


Assuntos
Doença de Parkinson , Dispositivos Eletrônicos Vestíveis , Humanos , Doença de Parkinson/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Aprendizado de Máquina , Estudos Longitudinais , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos
2.
J Gen Intern Med ; 35(1): 283-290, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31713040

RESUMO

BACKGROUND: Urine drug testing (UDT) is an essential tool to monitor opioid misuse among patients on chronic opioid therapy. Inaccurate interpretation of UDT can have deleterious consequences. Providers' ability to accurately interpret and document UDT, particularly definitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) results, has not been widely studied. OBJECTIVE: To examine whether providers correctly interpret, document, and communicate LC-MS/MS UDT results. DESIGN: This is a retrospective chart review of 160 UDT results (80 aberrant; 80 non-aberrant) between August 2017 and February 2018 from 5 ambulatory clinics (3 primary care, 1 oncology, 1 pain management). Aberrant results were classified into one or more of the following categories: illicit drug use, simulated compliance, not taking prescribed medication, and taking a medication not prescribed. Accurate result interpretation was defined as concordance between the provider's documented interpretation and an expert laboratory toxicologist's interpretation. Outcome measures were concordance between provider and laboratory interpretation of UDT results, documentation of UDT results, results acknowledgement in the electronic health record, communication of results to the patient, and rate of prescription refills. KEY RESULTS: Aberrant results were most frequently due to illicit drug use. Overall, only 88 of the 160 (55%) had any documented provider interpretations of which 25/88 (28%) were discordant with the laboratory toxicologist's interpretation. Thirty-six of the 160 (23%) documented communication of the results to the patient. Communicating results was more likely to be documented if the results were aberrant compared with non-aberrant (33/80 [41%] vs. 3/80 [4%], p < 0.001). In all cases where provider interpretations were discordant with the laboratory interpretation, prescriptions were refilled. CONCLUSIONS: Erroneous provider interpretation of UDT results, infrequent documentation of interpretation, lack of communication of results to patients, and prescription refills despite inaccurate interpretations are common. Expert assistance with urine toxicology interpretations may be needed to improve provider accuracy when interpreting toxicology results.


Assuntos
Preparações Farmacêuticas , Espectrometria de Massas em Tandem , Analgésicos Opioides , Cromatografia Líquida , Documentação , Seguimentos , Humanos , Estudos Retrospectivos , Detecção do Abuso de Substâncias
3.
Contemp Clin Trials ; 109: 106550, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34478869

RESUMO

Nursing home (NH) care of persons living with dementia is often made challenging by behavioral and psychological symptoms of dementia (BPSD) such as aggression, vocal outbursts, wandering, and withdrawal that occur due to cognitive and communication changes. Staff frequently communicate to NH residents using "elderspeak" which is patronizing speech similar to baby talk. Residents respond to elderspeak with increased BPSD that prompts use of psychotropic medication to control symptoms. The Changing Talk (CHAT) training educates staff about effective, person-centered communication strategies and reduces elderspeak by staff and subsequent BPSD among residents. This study will test effects of an adapted online version (CHATO) increasing access and dissemination of education to busy staff across diverse care settings. Nursing homes (N = 128) will be stratified and then randomized to CHATO education (n = 64) or to the control group (n = 64). Data on behavioral symptoms (primary outcomes) and psychotropic medication use (secondary outcomes) will be extracted from the Center for Medicare and Medicaid Services Minimum Data Set before and after education and will be compared between the groups using generalized linear mixed modeling. It is hypothesized that after completing the CHATO education residents will have reduced behavioral symptoms and psychotropic medication use compared to residents in control NHs. Additionally, factors related to NH participation and cost of the intervention will be determined. The overall goal of this study is to prepare for large scale dissemination and implementation of the evidence-based nonpharmacological CHATO intervention to reduce BPSD in residents with dementia across long-term care settings.


Assuntos
Comunicação , Demência , Idoso , Demência/prevenção & controle , Demência/psicologia , Humanos , Medicare , Casas de Saúde , Ensaios Clínicos Pragmáticos como Assunto , Qualidade de Vida , Estados Unidos
4.
Pain Physician ; 21(6): E583-E592, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30508989

RESUMO

BACKGROUND: The technical advantages of direct-to-definitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) urine testing for monitoring patient compliance in pain management are well known. However, the design and implementation of LC-MS/MS methods are more controversial, including factors such as determining appropriate cutoffs, specimen processing (e.g., specimen hydrolysis), reporting of qualitative and/or quantitative results, and test menu. OBJECTIVES: The objective of the research was to compare the clinical performance of our previous urine pain toxicology panel, a combination of immunoassay (IA) screens and LC-MS/MS, to our current pain toxicology panel, which features direct-to-definitive LC-MS/MS for 34 drugs and metabolites. STUDY DESIGN: Six months of results from our previous pain toxicology panel were compared to 5.5 months of results from our current pain toxicology panel, enabling us to make conclusions regarding clinical performance. SETTING: The research took place at Brigham and Women's Hospital in Boston, MA. METHODS: The percentage of false positive IA results was evaluated for our previous pain toxicology panel. The positivity rates for each drug and/or metabolite were calculated for both the previous and current panels, including rates of detection of both prescribed and illicit drugs. The turnaround time (TAT), direct and send-out costs associated with each approach, as well as projected cost savings were also determined. RESULTS: False positive rates with IA ranged from 0% to 29%; the highest false positive rate was seen for 6-acetylmorphine (6-AM). The elimination of IA, addition of metabolites, and/or lowering of cutoffs increased the detection rate of 6-AM, benzoylecgonine (cocaine metabolite), fentanyl, morphine, and oxycodone. The ability to differentiate compliance from simulated compliance improved after eliminating specimen hydrolysis. The TAT improved significantly and projected yearly cost savings with the current panel was $95,003 (USD). In our opinion, qualitative results appeared sufficient to assess compliance in the majority of cases. LIMITATIONS: Our study was performed in a single academic center in a specific geographic region; therefore, our results may not be generalizable to other types of centers or regions. CONCLUSION: Direct-to-definitive LC-MS/MS testing has several clinical benefits, including reduction of false positive results, improved assessment of patient compliance, decreased TAT, and increased detection of drug use and abuse. Cost savings were also realized using this approach. KEY WORDS: Direct-to-definitive, LC-MS/MS, immunoassay, sensitivity, cost, pain management, turnaround time, patient compliance.


Assuntos
Cromatografia Líquida/métodos , Imunoensaio/métodos , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Urinálise/métodos , Cromatografia Líquida/economia , Reações Falso-Positivas , Feminino , Humanos , Drogas Ilícitas/urina , Imunoensaio/economia , Manejo da Dor , Detecção do Abuso de Substâncias/economia , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Transtornos Relacionados ao Uso de Substâncias/urina , Espectrometria de Massas em Tandem/economia , Urinálise/economia
5.
Clin Chim Acta ; 481: 75-82, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29499200

RESUMO

BACKGROUND: Oral fluid (OF) has become an increasingly popular matrix to assess compliance in pain management and addiction settings as it reduces the likelihood of adulteration. However, drug concentrations and windows of detection are not as well studied in OF as in urine (UR). We compared the clinical utility and analytical performance of OF and UR as matrices for detecting common benzodiazepines and opioids. METHODS: OF and UR concentrations of 5 benzodiazepines and 7 opioids were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 263 paired OF and UR specimens. UR creatinine was measured and prescription medications were reviewed. RESULTS: The benzodiazepines 7-aminoclonazepam, lorazepam, and oxazepam exhibited statistically higher detection rates in UR. For opioids, 6-AM was statistically more likely to be detected in OF, while hydromorphone and oxymorphone were statistically more likely to be detected in UR. Chemical properties including glucuronidation explain preferential detection in each matrix, not UR creatinine nor prescription status. CONCLUSION: We found that OF is the preferred matrix for 6-AM, while UR is preferred for 7-aminoclonazepam, lorazepam, oxazepam, hydromorphone, and oxymorphone. However, OF should be considered if the risk of adulteration is high and use and/or misuse of benzodiazepines, hydromorphone, and oxymorphone is low.


Assuntos
Analgésicos Opioides/análise , Benzodiazepinas/análise , Líquidos Corporais/química , Detecção do Abuso de Substâncias , Urinálise , Cromatografia Líquida , Humanos , Espectrometria de Massas em Tandem
6.
Int J Med Inform ; 106: 9-16, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28870384

RESUMO

BACKGROUND: Recent U.S. government regulations incentivize implementation of an electronic health record (EHR) with computerized order entry and structured results display. Many institutions have also chosen to interface their EHR to their laboratory information system (LIS). Reported long-term benefits include increased efficiency and improved quality and safety. In order to successfully implement an interfaced EHR-LIS, institutions must plan years in advance and anticipate the impact of an integrated system. It can be challenging to fully understand the technical, workflow and resource aspects and adequately prepare for a potentially protracted system implementation and the subsequent stabilization. OBJECTIVES: We describe the top ten challenges that we encountered in our clinical laboratories following the implementation of an interfaced EHR-LIS and offer suggestions on how to overcome these challenges. METHODS: This study was performed at a 777-bed, tertiary care center which recently implemented an interfaced EHR-LIS. Challenges were recorded during EHR-LIS implementation and stabilization and the authors describe the top ten. RESULTS: Our top ten challenges were selection and harmonization of test codes, detailed training for providers on test ordering, communication with EHR provider champions during the build process, fluid orders and collections, supporting specialized workflows, sufficient reports and metrics, increased volume of inpatient venipunctures, adequate resources during stabilization, unanticipated changes to laboratory workflow and ordering specimens for anatomic pathology. A few suggestions to overcome these challenges include regular meetings with clinical champions, advanced considerations of reports and metrics that will be needed, adequate training of laboratory staff on new workflows in the EHR and defining all tests including anatomic pathology in the LIS. CONCLUSION: EHR-LIS implementations have many challenges requiring institutions to adapt and develop new infrastructures. This article should be helpful to other institutions facing or undergoing a similar endeavor.


Assuntos
Centros Médicos Acadêmicos/normas , Sistemas de Informação em Laboratório Clínico/organização & administração , Eficiência Organizacional , Registros Eletrônicos de Saúde/estatística & dados numéricos , Laboratórios/normas , Atitude do Pessoal de Saúde , Atitude Frente aos Computadores , Humanos , Fluxo de Trabalho
7.
Lab Med ; 48(3): 282-289, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28934512

RESUMO

BACKGROUND: Patient satisfaction in outpatient phlebotomy settings typically depends on wait time and venipuncture experience, and many patients equate their experiences with their overall satisfaction with the hospital. METHODS: We compared patient service times and preanalytical errors pre- and postimplementation of an integrated electronic health record (EHR)-laboratory information system (LIS) and electronic specimen collection module. We also measured patient wait time and assessed patient satisfaction using a 5-question survey. RESULTS: The percentage of patients waiting less than 10 minutes increased from 86% preimplementation to 93% postimplementation of the EHR-LIS (P ≤.001). The median total service time decreased significantly, from 6 minutes (IQR, 4-8 minutes), to 5 minutes (IQR, 3-6 minutes) (P = .005). The preanalytical errors decreased significantly, from 3.20 to 1.93 errors per 1000 specimens (P ≤.001). Overall patient satisfaction improved, with an increase in excellent responses for all 5 questions (P ≤.001). CONCLUSIONS: We found several benefits of implementing an electronic specimen collection module, including decreased wait and service times, improved patient satisfaction, and a reduction in preanalytical errors.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Satisfação do Paciente/estatística & dados numéricos , Registros Eletrônicos de Saúde , Humanos , Laboratórios , Pacientes Ambulatoriais , Flebotomia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA