Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 22(1): 211, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35804321

RESUMO

BACKGROUND: A mismatch between oxygen delivery (DO2) and consumption (VO2) is associated with increased perioperative morbidity and mortality. Hyperlactatemia is often used as an early screening tool, but this non-continuous measurement requires intermittent arterial line sampling. Having a non-invasive tool to rapidly detect inadequate DO2 is of great clinical relevance. The respiratory exchange ratio (RER) can be easily measured in all intubated patients and has been shown to predict postoperative complications. We therefore aimed to assess the discriminative ability of the RER to detect an inadequate DO2 as reflected by hyperlactatemia in patients having intermediate-to-high risk abdominal surgery. METHODS: This historical cohort study included all consecutive patients who underwent intermediate-to-high risk surgery from January 1st, 2014, to April 30th, 2019 except those who did not have RER and/or arterial lactate measured. Blood lactate levels were measured routinely at the beginning and end of surgery and RER was calculated at the same moment as the blood gas sampling. The present study tested the hypothesis that RER measured at the end of surgery could detect hyperlactatemia at that time. A receiver operating characteristic (ROC) curve was constructed to assess if RER calculated at the end of the surgery could detect hyperlactatemia. The chosen RER threshold corresponded to the highest value of the sum of the specificity and the sensitivity (Youden Index). RESULTS: Among the 996 patients available in our study cohort, 941 were included and analyzed. The area under the ROC curve was 0.73 (95% CI: 0.70 to 0.76; p < 0.001), with a RER threshold of 0.75, allowing to discriminate a lactate > 1.5 mmol/L with a sensitivity of 87.5% and a specificity of 49.5%. CONCLUSION: In mechanically ventilated patients undergoing intermediate to high-risk abdominal surgery, the RER had moderate discriminative abilities to detect hyperlactatemia. Increased values should prompt clinicians to investigate for the presence of hyperlactatemia and treat any potential causes of DO2/VO2 mismatch as suggested by the subsequent presence of hyperlactatemia.


Assuntos
Hiperlactatemia , Estudos de Coortes , Humanos , Ácido Láctico , Complicações Pós-Operatórias/diagnóstico
2.
BMC Anesthesiol ; 22(1): 300, 2022 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-36131247

RESUMO

BACKGROUND: In patients with end stage liver disease (ESLD) scheduled for liver transplantation (LT), an intraoperative incidental finding of elevated mean pulmonary arterial pressure (mPAP) may be observed. Its association with patient outcome has not been evaluated. We aimed to estimate the effects of an incidental finding of a mPAP > 20 mmHg during LT on the incidence of pulmonary complications. METHODS: We examined all patients who underwent a LT at Paul-Brousse hospital between January 1,2015 and December 31,2020. Those who received: a LT due to acute liver failure, a combined transplantation, or a retransplantation were excluded, as well as patients for whom known porto-pulmonary hypertension was treated before the LT or patients who underwent a LT for other etiologies than ESLD. Using right sided pulmonary artery catheterization measurements made following anesthesia induction, the study cohort was divided into two groups using a mPAP cutoff of 20 mmHg. The primary outcome was a composite of pulmonary complications. Univariate and multivariable logistic regression analyses were performed to identify variables associated with the primary outcome. Sensitivity analyses of multivariable models were also conducted with other mPAP cutoffs (mPAP ≥ 25 mmHg and ≥ 35 mmHg) and even with mPAP as a continuous variable. RESULTS: Of 942 patients who underwent a LT, 659 met our inclusion criteria. Among them, 446 patients (67.7%) presented with an elevated mPAP (mPAP of 26.4 ± 5.9 mmHg). When adjusted for confounding factors, an elevated mPAP was not associated with a higher risk of pulmonary complications (adjusted OR: 1.16; 95%CI 0.8-1.7), nor with 90 days-mortality or any other complications. In our sensitivity analyses, we observed a lower prevalence of elevated mPAP when increasing thresholds (235 patients (35.7%) had an elevated mPAP when defined as ≥ 25 mmHg and 41 patients (6.2%) had an elevated mPAP when defined as ≥ 35 mmHg). We did not observe consistent association between a mPAP ≥ 25 mmHg or a mPAP ≥ 35 mmHg and our outcomes. CONCLUSION: Incidental finding of elevated mPAP was highly prevalent during LT, but it was not associated with a higher risk of postoperative complications.


Assuntos
Doença Hepática Terminal , Hipertensão Pulmonar , Transplante de Fígado , Pressão Arterial , Doença Hepática Terminal/complicações , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/epidemiologia , Achados Incidentais , Transplante de Fígado/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Artéria Pulmonar , Estudos Retrospectivos
3.
J Clin Monit Comput ; 36(5): 1525-1533, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34978654

RESUMO

We compared blood pressure (BP) values obtained with a new optical smartphone application (OptiBP™) with BP values obtained using a non-invasive automatic oscillometric brachial cuff (reference method) during the first 2 h of surveillance in a post-anesthesia care unit in patients after non-cardiac surgery. Three simultaneous BP measurements of both methods were recorded every 30 min over a 2-h period. The agreement between measurements was investigated using Bland-Altman and error grid analyses. We also evaluated the performance of the OptiBP™ using ISO81060-2:2018 standards which requires the mean of the differences ± standard deviation (SD) between both methods to be less than 5 mmHg ± 8 mmHg. Of 120 patients enrolled, 101 patients were included in the statistical analysis. The Bland-Altman analysis demonstrated a mean of the differences ± SD between the test and reference methods of + 1 mmHg ± 7 mmHg for mean arterial pressure (MAP), + 2 mmHg ± 11 mmHg for systolic arterial pressure (SAP), and + 1 mmHg ± 8 mmHg for diastolic arterial pressure (DAP). Error grid analysis showed that the proportions of measurement pairs in risk zones A to E were 90.3% (no risk), 9.7% (low risk), 0% (moderate risk), 0% (significant risk), 0% (dangerous risk) for MAP and 89.9%, 9.1%, 1%, 0%, 0% for SAP. We observed a good agreement between BP values obtained by the OptiBP™ system and BP values obtained with the reference method. The OptiBP™ system fulfilled the AAMI validation requirements for MAP and DAP and error grid analysis indicated that the vast majority of measurement pairs (≥ 99%) were in risk zones A and B.Trial Registration ClinicalTrials.gov Identifier: NCT04262323.


Assuntos
Anestesia , Smartphone , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Monitores de Pressão Arterial , Humanos , Oscilometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA