RESUMO
Acute cardiovascular physical exercise improves cognitive performance, as evidenced by a reduction in reaction time (RT). However, the mechanistic understanding of how this occurs is elusive and has not been rigorously investigated in humans. Here, using positron emission tomography (PET) with [11 C]raclopride, in a multi-experiment study we investigated whether acute exercise releases endogenous dopamine (DA) in the brain. We hypothesized that acute exercise augments the brain DA system, and that RT improvement is correlated with this endogenous DA release. The PET study (Experiment 1: n = 16) demonstrated that acute physical exercise released endogenous DA, and that endogenous DA release was correlated with improvements in RT of the Go/No-Go task. Thereafter, using two electrical muscle stimulation (EMS) studies (Experiments 2 and 3: n = 18 and 22 respectively), we investigated what triggers RT improvement. The EMS studies indicated that EMS with moderate arm cranking improved RT, but RT was not improved following EMS alone or EMS combined with no load arm cranking. The novel mechanistic findings from these experiments are: (1) endogenous DA appears to be an important neuromodulator for RT improvement and (2) RT is only altered when exercise is associated with central signals from higher brain centres. Our findings explain how humans rapidly alter their behaviour using neuromodulatory systems and have significant implications for promotion of cognitive health. KEY POINTS: Acute cardiovascular exercise improves cognitive performance, as evidenced by a reduction in reaction time (RT). However, the mechanistic understanding of how this occurs is elusive and has not been rigorously investigated in humans. Using the neurochemical specificity of [11 C]raclopride positron emission tomography, we demonstrated that acute supine cycling released endogenous dopamine (DA), and that this release was correlated with improved RT. Additional electrical muscle stimulation studies demonstrated that peripherally driven muscle contractions (i.e. exercise) were insufficient to improve RT. The current study suggests that endogenous DA is an important neuromodulator for RT improvement, and that RT is only altered when exercise is associated with central signals from higher brain centres.
Assuntos
Dopamina , Tomografia por Emissão de Pósitrons , Humanos , Racloprida , Tempo de Reação , Tomografia por Emissão de Pósitrons/métodos , Exercício Físico , NeurotransmissoresRESUMO
BACKGROUND: P2Y12 inhibitor monotherapy without aspirin immediately after percutaneous coronary intervention (PCI) has not been tested in East Asian patients, so in this study we aimed to assess the safety and feasibility of reduced dose (3.75 mg/day) prasugrel monotherapy in Japanese patients presenting with chronic coronary syndrome (CCS).MethodsâandâResults: ASET-JAPAN is a prospective, multicenter, single-arm pilot study that completed enrolment of 206 patients from 12 Japanese centers in September 2022. Patients with native de-novo coronary lesions and a SYNTAX score <23 were treated exclusively with biodegradable-polymer platinum-chromium everolimus-eluting stent(s). Patients were loaded with standard dual antiplatelet therapy (DAPT) and following successful PCI and optimal stent deployment, they received low-dose prasugrel (3.75 mg/day) monotherapy for 3 months. The primary ischemic endpoint was a composite of cardiac death, spontaneous target-vessel myocardial infarction, or definite stent thrombosis. The primary bleeding endpoint was Bleeding Academic Research Consortium (BARC) type 3 or 5. At 3-month follow-up, there were no primary bleeding or ischemic events, or any stent thrombosis. CONCLUSIONS: This pilot study showed the safety and feasibility of prasugrel monotherapy in selected low-risk Japanese patients with CCS. This "aspirin-free" strategy may be a safe alternative to traditional DAPT following PCI.
Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Cloridrato de Prasugrel , Humanos , Aspirina , População do Leste Asiático , Everolimo , Hemorragia , Japão , Intervenção Coronária Percutânea/métodos , Projetos Piloto , Platina , Polímeros , Cloridrato de Prasugrel/uso terapêutico , Estudos ProspectivosRESUMO
Despite advanced understanding of the biology of atherosclerosis, coronary heart disease remains the leading cause of death worldwide. Progress has been challenging as half of the individuals who suffer sudden cardiac death do not experience premonitory symptoms. Furthermore, it is well-recognized that also a plaque that does not cause a haemodynamically significant stenosis can trigger a sudden cardiac event, yet the majority of ruptured or eroded plaques remain clinically silent. In the past 30 years since the term 'vulnerable plaque' was introduced, there have been major advances in the understanding of plaque pathogenesis and pathophysiology, shifting from pursuing features of 'vulnerability' of a specific lesion to the more comprehensive goal of identifying patient 'cardiovascular vulnerability'. It has been also recognized that aside a thin-capped, lipid-rich plaque associated with plaque rupture, acute coronary syndromes (ACS) are also caused by plaque erosion underlying between 25% and 60% of ACS nowadays, by calcified nodule or by functional coronary alterations. While there have been advances in preventive strategies and in pharmacotherapy, with improved agents to reduce cholesterol, thrombosis, and inflammation, events continue to occur in patients receiving optimal medical treatment. Although at present the positive predictive value of imaging precursors of the culprit plaques remains too low for clinical relevance, improving coronary plaque imaging may be instrumental in guiding pharmacotherapy intensity and could facilitate optimal allocation of novel, more aggressive, and costly treatment strategies. Recent technical and diagnostic advances justify continuation of interdisciplinary research efforts to improve cardiovascular prognosis by both systemic and 'local' diagnostics and therapies. The present state-of-the-art document aims to present and critically appraise the latest evidence, developments, and future perspectives in detection, prevention, and treatment of 'high-risk' plaques occurring in 'vulnerable' patients.
Assuntos
Síndrome Coronariana Aguda , Aterosclerose , Doença da Artéria Coronariana , Doença das Coronárias , Placa Aterosclerótica , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Humanos , Placa Aterosclerótica/diagnóstico por imagemRESUMO
BACKGROUND: MiStent is a drug-eluting stent with a fully absorbable polymer coating containing and embedding a microcrystalline form of sirolimus into the vessel wall. It was developed to overcome the limitation of current durable polymer drug-eluting stents eluting amorphous sirolimus. The clinical effect of MiStent sirolimus-eluting stent compared with a durable polymer drug-eluting stents has not been investigated in a large randomised trial in an all-comer population. METHODS: We did a randomised, single-blind, multicentre, phase 3 study (DESSOLVE III) at 20 hospitals in Germany, France, Netherlands, and Poland. Eligible participants were any patients aged at least 18 years who underwent percutaneous coronary intervention in a lesion and had a reference vessel diameter of 2·50-3·75 mm. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting bioresorbable polymer stent (MiStent) or an everolimus-eluting durable polymer stent (Xience). Randomisation was done by local investigators via web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint (DOCE)-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between the groups at 12 months after the procedure assessed by intention-to-treat. A margin of 4·0% was defined for non-inferiority of the MiStent group compared with the Xience group. All participants were included in the safety analyses. This trial is registered with ClinicalTrials.gov, number NCT02385279. FINDINGS: Between March 20, and Dec 3, 2015, we randomly assigned 1398 patients with 2030 lesions; 703 patients with 1037 lesions were assigned to MiStent, of whom 697 received the index procedure, and 695 patients with 993 lesions were asssigned to Xience, of whom 690 received the index procedure. At 12 months, the primary endpoint had occurred in 40 patients (5·8%) in the sirolimus-eluting stent group and in 45 patients (6·5%) in the everolimus-eluting stent group (absolute difference -0·8% [95% CI -3·3 to 1·8], pnon-inferiority=0·0001). Procedural complications occurred in 12 patients (1·7%) in the sirolimus-eluting stent group and ten patients (1·4%) in the everolimus-eluting stent group; no clinical adverse events could be attributed to these dislodgements through a minimum of 12 months of follow-up. The rate of stent thrombosis, a safety indicator, did not differ between groups and was low in both treatment groups. INTERPRETATION: The sirolimus-eluting bioabsorbable polymer stent was non-inferior to the everolimus-eluting durable polymer stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. MiStent seems a reasonable alternative to other stents in clinical practice. FUNDING: The European Cardiovascular Research Institute, Micell Technologies (Durham, NC, USA), and Stentys (Paris, France).
Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Implantes Absorvíveis , Idoso , Feminino , Humanos , Masculino , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea , Estudos Prospectivos , Método Simples-Cego , Resultado do TratamentoRESUMO
OBJECTIVES: To investigate the impact of minimal stent area (MSA) evaluated by post-procedural intravascular ultrasound (IVUS) on clinical outcomes after contemporary PCI in patients with three-vessel disease (TVD). BACKGROUND: The impact of post-procedural MSA on clinical outcomes has not yet been extensively studied in patients with TVD. METHODS: The SYNTAX II study is a multicenter, all-comers, open-label, single arm study that investigated the impact of a state-of-the-art PCI strategy on clinical outcomes in patients with TVD (454 patients with 1,559 lesions). The relationships between post-procedural MSA and lesion-level outcomes at 2 years were investigated. Clinical events adjudicated per patient by clinical event committee were assessed per lesion. Lesion-oriented composite endpoint (LOCE) was defined as the composite of cardiac death, target-vessel myocardial infarction, and ischemia-driven target lesion revascularization. RESULTS: Eight hundred and nineteen lesions with post-procedural MSA available in 367 patients were included in the analysis. The post-procedural MSA per lesion was divided into terciles (smallest tercile: ≤5.0 mm2 , intermediate tercile: 5.0-6.7 mm2 , and largest tercile: >6.7 mm2 ). LOCE was observed in 16/288 (5.6%), 15/265 (5.7%), and 8/266 (3.0%) (P = 0.266). Target lesion revascularization (TLR) was observed in 16/288(5.6%), 12/265 (4.5%), and 4/266 (1.5%) (P = 0.042). The multivariate analysis demonstrated that smaller post-procedural MSA, as well as creatinine clearance, history of previous stroke, chronic total occlusion, and lesion SYNTAX Score was an independent predictor of TLR. CONCLUSIONS: In the SYNTAX II trial, larger post-procedural MSA was independently associated with the lower rate of TLR at 2 years.
Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: Little is known about serial changes in lumen and device dimensions after bioresorbable scaffold implantation in a growing animal model. MethodsâandâResults: ABSORB (n=14) or bare metal stents (ICROS amg [Abbott Vascular, Santa Clara, CA, USA], Winsen-Luhe, Germany; n=15) were implanted in the coronary arteries of domestic swine (a hybrid of Finnish-Norwegian Landrace swine) weighing 30-35 kg. Angiography and optical coherence tomography (OCT) were performed immediately after implantation and repeated at 7 days, 1, 3, 6 and 12 months after the index procedure. One month after implantation, mean lumen area decreased relative to baseline in both groups (relative area change from baseline, -41.4±15.6% for ABSORB vs. -20.9±18.6% for ICROS) while mean device area decreased only in the ABSORB group (relative area change: -11.1±9.4% vs. +0.14±7.95%, respectively). At 12 months, mean lumen area increased relative to baseline in both groups (relative area change from baseline, +55.6±22.4% vs. +32.3±83.6%, respectively) in accordance with the swine growth weighing up to 260-300 kg. Mean device area in the ICROS group remained stable whereas that in the ABSORB group began to increase between 3 and 6 months along with the vessel growth (relative area change: +107.8±25.7% vs. +0.14±7.95%). CONCLUSIONS: In the growing porcine model, ABSORB was associated with greater extent of recoil 1 month after implantation compared with ICROS but demonstrated substantial adaptability to vessel growth in late phase.
Assuntos
Implantes Absorvíveis/normas , Vasos Coronários/diagnóstico por imagem , Stents/normas , Tomografia de Coerência Óptica/métodos , Animais , Angiografia Coronária/métodos , Vasos Coronários/crescimento & desenvolvimento , Vasos Coronários/cirurgia , Modelos Animais , Desenho de Prótese/normas , Suínos , Fatores de TempoRESUMO
Aim: In current device trials, the values of angiographic late lumen loss (LLL) have become extremely low and the relationship between LLL and clinical endpoints has not been recently re-evaluated. The impact of LLL on target lesion revascularization (TLR) in a patient- and study-level analysis of contemporary coronary devices was investigated. Methods and results: We performed a patient-level meta-analysis of seven randomized controlled trials including 2426 patients treated with first- and second-generation drug-eluting stents (DES) and a study-level meta-analysis of 40 studies including 19 199 patients treated with CE-marked DES. In the patient-level analysis, the probability regression curve showed an exponential relationship between in-stent LLL and 2-year incidence of TLR. The optimal cut-off value of LLL based on Youden's index for 2-year TLR event was 0.50 mm. In the Cox proportional hazard model, LLL >0.50 mm was independently associated with an increased incidence of TLR up to 4 years after angiographic follow-up {adjusted hazard ratio (HR) 6.62 [95% confidence interval (95% CI) 4.67-9.39], P < 0.001}. In the meta-regression analysis of the DES studies, pooled mean value of LLL was as low as 0.23 mm (95% CI 0.20-0.26), and there was a moderate correlation between the 1- and 5-year incidence of TLR and the percentage of the lesions with LLL >0.50 mm (R2 = 0.44, P < 0.001 at 1 year, R2 = 0.40, P < 0.001 at 5 years). Conclusion: An angiographic LLL ≤0.50 mm was not predictive of the incidence of TLR whereas a LLL >0.50 mm was. Low LLL in contemporary device trials may not be a sufficiently discriminating parameter for the comparative evaluation of devices.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Revascularização Miocárdica/métodos , Angiografia Coronária , Doença da Artéria Coronariana/patologia , HumanosRESUMO
Aims: Coronary computed tomography angiography (CTA) has emerged as a non-invasive diagnostic method for patients with suspected coronary artery disease, but its usefulness in patients with complex coronary artery disease remains to be investigated. The present study sought to determine the agreement between separate heart teams on treatment decision-making based on either coronary CTA or conventional angiography. Methods and results: Separate heart teams composed of an interventional cardiologist, a cardiac surgeon, and a radiologist were randomized to assess the coronary artery disease with either coronary CTA or conventional angiography in patients with de novo left main or three-vessel coronary artery disease. Each heart team, blinded for the other imaging modality, quantified the anatomical complexity using the SYNTAX score and integrated clinical information using the SYNTAX Score II to provide a treatment recommendations based on mortality prediction at 4 years: coronary artery bypass grafting (CABG), percutaneous coronary intervention (PCI), or equipoise between CABG and PCI. The primary endpoint was the agreement between heart teams on the revascularization strategy. The secondary endpoint was the impact of fractional flow reserve derived from coronary CTA (FFRCT) on treatment decision and procedural planning. Overall, 223 patients were included. A treatment recommendation of CABG was made in 28% of the cases with coronary CTA and in 26% with conventional angiography. The agreement concerning treatment decision between coronary CTA and conventional angiography was high (Cohen's kappa 0.82, 95% confidence interval 0.74-0.91). The heart teams agreed on the coronary segments to be revascularized in 80% of the cases. FFRCT was available for 869/1108 lesions (196/223 patients). Fractional flow reserve derived from coronary CTA changed the treatment decision in 7% of the patients. Conclusion: In patients with left main or three-vessel coronary artery disease, a heart team treatment decision-making based on coronary CTA showed high agreement with the decision derived from conventional coronary angiography suggesting the potential feasibility of a treatment decision-making and planning based solely on this non-invasive imaging modality and clinical information. Trial registration number: NCT02813473.
Assuntos
Tomada de Decisão Clínica/métodos , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Idoso , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária PercutâneaRESUMO
Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.
Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Teorema de Bayes , Humanos , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: A novel bare metal stent with an SiO2coating was developed to prevent excessive neointimal hyperplasia by inertization of the metallic stent surface. The efficacy of the device was demonstrated in a preclinical model. The aim of this first-in-man trial was to assess the safety and feasibility of the new device.MethodsâandâResults:This prospective non-randomized single-arm trial was designed to enroll 35 patients with a de novo coronary lesion. Quantitative coronary angiography and optical coherence tomography (OCT) were performed at the baseline procedure and at the 6-month follow-up. Stent implantation was performed with OCT guidance according to optimal stent implantation criteria. The trial was terminated upon the advice of the data safety monitoring board after enrolling 14 patients due to the high incidence of re-intervention. Optimal OCT implantation criteria were achieved in only 8.3% of lesions. At 6 months, angiographic in-stent late lumen loss as the primary endpoint was 0.77±0.44 mm, and binary restenosis occurred in 33.3% of lesions. At the 6-month OCT, neointimal volume obstruction was 32.8±15.6% with a neointimal thickness of 237±117 µm. At 12 months, the device-oriented composite endpoint (defined as cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization rate) was 33.3%. CONCLUSIONS: In contrast with the preclinical study, the Axetis stent did not efficiently suppress neointimal hyperplasia in humans in this trial.
Assuntos
Materiais Revestidos Biocompatíveis/química , Estenose Coronária/terapia , Dióxido de Silício , Stents/normas , Idoso , Materiais Revestidos Biocompatíveis/normas , Reestenose Coronária/patologia , Humanos , Hiperplasia/prevenção & controle , Pessoa de Meia-Idade , Neointima/patologia , Stents/efeitos adversos , Falha de TratamentoRESUMO
AIMS: To compare the long-term safety and efficacy of bioresorbable vascular scaffold (BVS) with everolimus-eluting stent (EES) after percutaneous coronary interventions. METHODS AND RESULTS: A systematic review and meta-analysis of randomized clinical trials comparing clinical outcomes of patients treated with BVS and EES with at least 24 months follow-up was performed. Adjusted random-effect model by the Knapp-Hartung method was used to compute odds ratios (OR) and 95% confidence intervals (CI). The primary safety outcome of interest was the risk of definite/probable device thrombosis (DT). The primary efficacy outcome of interest was the risk of target lesion failure (TLF). Five randomized clinical trials (n = 1730) were included. Patients treated with Absorb BVS had a higher risk of definite/probable DT compared with patients treated with EES (OR 2.93, 95%CI 1.37-6.26, P = 0.01). Very late DT (VLDT) occurred in 13 patients [12/996 (1.4%, 95%CI: 0.08-2.5) Absorb BVS vs. 1/701 (0.5%, 95%CI: 0.2-1.6) EES; OR 3.04; 95%CI 1.2-7.68, P = 0.03], 92% of the VLDT in the BVS group occurred in the absence of dual antiplatelet therapy (DAPT). Patients treated with Absorb BVS had a trend towards higher risk of TLF (OR 1.48, 95%CI 0.90-2.42, P = 0.09), driven by a higher risk of target vessel myocardial infarction and ischaemia-driven target lesion revascularization. No difference was found in the risk of cardiac death. CONCLUSION: Compared with EES, the use of Absorb BVS was associated with a higher rate of DT and a trend towards higher risk of TLF. VLDT occurred in 1.4% of the patients, the majority of these events occurred in the absence of DAPT.
Assuntos
Implantes Absorvíveis , Trombose Coronária/etiologia , Falha de Prótese , Alicerces Teciduais , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Oclusão de Enxerto Vascular , Humanos , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Infarto do Miocárdio com Supradesnível do Segmento ST/terapiaAssuntos
Vasos Coronários , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Fenômenos Biomecânicos/fisiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Hemorreologia/fisiologia , Humanos , Imageamento Tridimensional , Estresse MecânicoRESUMO
Recently, we found that albumin overload induces expression of the transcription factor hypoxia-inducible factor-1α (HIF-1α) protein and several HIF-1 target genes in human renal proximal tubular epithelial cell line HK-2. In this study, the role of albumin-bound fatty acids in the albumin-induced HIF-1 activation was studied. The enhancing effect of fatty acid-bearing human serum albumin [FA(+)HSA] treatment on HIF-1α protein expression was much greater than that of fatty acid-depleted human serum albumin [FA(-)HSA] treatment. The FA(+)HSA treatment induced HIF-1 target gene mRNAs such as those of glucose transporter 1 (GLUT1), glyceraldehyde 3-phosphate dehydrogenase (GAPDH), and breast cancer resistance protein (BCRP) in concentration-dependent manners, while FA(-)HSA caused no significant increases in these mRNAs. Consistent with increased GLUT1 mRNA, GLUT1 protein expression and GLUT inhibitor cytochalasin B-sensitive d-[(3)H]glucose uptake activity were significantly enhanced by treatment with FA(+)HSA, but not with FA(-)HSA. These findings indicate that fatty acids bound to albumin play a crucial role in albumin-induced HIF-1 activation followed by changes in HIF-1 target gene expression and protein product activity.
Assuntos
Células Epiteliais/metabolismo , Ácidos Graxos/administração & dosagem , Ácidos Graxos/sangue , Subunidade alfa do Fator 1 Induzível por Hipóxia/biossíntese , Túbulos Renais Proximais/metabolismo , Albumina Sérica/administração & dosagem , Albumina Sérica/metabolismo , Linhagem Celular , Relação Dose-Resposta a Droga , Células Epiteliais/efeitos dos fármacos , Proteínas Facilitadoras de Transporte de Glucose/metabolismo , Humanos , Túbulos Renais Proximais/efeitos dos fármacos , Ligação ProteicaRESUMO
The optical coherence tomography (OCT)-based calcium scoring system was developed to guide optimal lesion preparation strategies for percutaneous coronary intervention (PCI) of calcified lesions. However, the score was derived retrospectively, and a prospective investigation is lacking. The CORAL (UMIN000053266) study was a single-arm, prospective, multicenter study that included patients with calcified lesions with OCT-calcium score of 1-2 to investigate whether these lesions could be optimally treated with a balloon-only preparation strategy using a non-compliant/scoring/cutting balloon. The primary endpoint was strategy success (successful stent placement with a final percent diameter stenosis [%DS] < 20% and Thrombolysis In Myocardial Infarction flow grade III without crossover to rotational atherectomy/orbital atherectomy/intravascular lithotripsy [RA/OA/IVL]). A superiority analysis for the primary endpoint was performed by comparing the study cohort with a performance goal of 83.3%. One hundred and eighteen patients with 130 lesions were enrolled. The mean age was 79.0 ± 10.3 years, and 79 patients (66.9%) were male. The OCT-calcium score was 1 for 81 lesions (62.3%) and 2 for 49 lesions (37.7%). The %DS improved from 47.0 ± 14.8% preprocedure to 11.1 ± 5.6% postprocedure. Stent expansion ≥ 70% was achieved in 90.2%. The strategy success rate was 93.1% (95% confidence interval: 87.3-96.8), and superiority against the performance goal was achieved without any crossover to RA/OA/IVL (P = 0.0027). The OCT-calcium score could identify mild/moderately calcified lesions treatable by PCI with the balloon-first strategy using a non-compliant/scoring/cutting balloon for predilatation, with a high strategy success rate. These results support the intravascular imaging-based treatment algorithm for calcified lesions proposed by CVIT.
RESUMO
BACKGROUND: Vessel-level physiological data derived from pressure wire measurements are one of the important determinant factors in the optimal revascularisation strategy for patients with multivessel disease (MVD). However, these may result in complications and a prolonged procedure time. AIMS: The feasibility of using the quantitative flow ratio (QFR), an angiography-derived fractional flow reserve (FFR), in Heart Team discussions to determine the optimal revascularisation strategy for patients with MVD was investigated. METHODS: Two Heart Teams were randomly assigned either QFR- or FFR-based data of the included patients. They then discussed the optimal revascularisation mode (percutaneous coronary intervention [PCI] or coronary artery bypass grafting [CABG]) for each patient and made treatment recommendations. The primary endpoint of the trial was the level of agreement between the treatment recommendations of both teams as assessed using Cohen's kappa. RESULTS: The trial included 248 patients with MVD from 10 study sites. Cohen's kappa in the recommended revascularisation modes between the QFR and FFR approaches was 0.73 [95% confidence interval {CI} : 0.62-0.83]. As for the revascularisation planning, agreements in the target vessels for PCI and CABG were substantial for both revascularisation modes (Cohen's kappa=0.72 [95% CI: 0.66-0.78] and 0.72 [95% CI: 0.66-0.78], respectively). The team assigned to the QFR approach provided consistent recommended revascularisation modes even after being made aware of the FFR data (Cohen's kappa=0.95 [95% CI:0.90-1.00]). CONCLUSIONS: QFR provided feasible physiological data in Heart Team discussions to determine the optimal revascularisation strategy for MVD. The QFR and FFR approaches agreed substantially in terms of treatment recommendations.
Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Feminino , Masculino , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Idoso , Ponte de Artéria Coronária/métodos , Tomada de Decisão Clínica , Cateterismo Cardíaco/métodos , Equipe de Assistência ao PacienteRESUMO
BACKGROUND: The geographical disparity in the pathophysiological pattern of coronary artery disease (CAD) among patients undergoing percutaneous coronary intervention (PCI) is unknown. OBJECTIVES: To elucidate the geographical variance in the pathophysiological characteristics of CAD. METHODS: Physiological indices derived from angiography-based fractional flow reserve pullbacks from patients with chronic coronary syndrome enrolled in the ASET Japan (n = 206) and ASET Brazil (n = 201) studies, which shared the same eligibility criteria, were analysed. The pathophysiological patterns of CAD were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the µQFR pullback pressure gradient index. RESULTS: Significant functional stenoses pre-PCI (µQFR ≤0.80) were more frequent in ASET Japan compared to ASET Brazil (89.9% vs. 67.5%, p < 0.001), as were rates of a post-PCI µQFR <0.91 (22.1% vs. 12.9%, p = 0.013). In the multivariable analysis, pre-procedural µQFR and diffuse disease were independent factors for predicting a post-PCI µQFR <0.91, which contributed to the different rates of post-PCI µQFR ≥0.91 between the studies. Among vessels with a post-PCI µQFR <0.91, a consistent diffuse pattern of CAD pre- and post-PCI occurred in 78.3% and 76.7% of patients in ASET Japan and Brazil, respectively; only 6.3% (Japan) and 10.0% (Brazil) of vessels had a major residual gradient. Independent risk factors for diffuse disease were diabetes mellitus in ASET Japan, and age and male gender in Brazil. CONCLUSIONS: There was geographic disparity in pre-procedural angiography-based pathophysiological characteristics. The combined pre-procedural physiological assessment of vessel µQFR and diffuseness of CAD may potentially identify patients who will benefit most from PCI.
Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Resultado do Tratamento , Vasos Coronários , Valor Preditivo dos TestesRESUMO
Protamine, a mixture of polypeptides that is rich in arginine, has been used clinically as an antidote to heparin overdoses and a complexing agent in a long-acting insulin preparation. When protamine is administered intravenously, its abundant accumulation in the kidneys has been reported. However, the renal uptake mechanism for protamine is not clear. In this study, we examined the transport mechanism for protamine in opossum kidney (OK) cells, a suitable in vitro model for renal proximal tubular epithelial cells. Flow cytometric analysis revealed that the association of fluorescein isothiocyanate (FITC)-labeled protamine from salmon (FITC-protamine) by OK cells was inhibited by unlabeled protamine in a concentration-dependent manner. The association of FITC-protamine was temperature- and energy-dependent. Confocal microscopy analysis showed that the fluorescence was localized in the cytoplasm and nucleus of OK cells. In addition, FITC-protamine association was inhibited by cationic drugs such as polycationic gentamicin and polymixin B, but it was increased by a basic amino acid, arginine. Inhibitors for clathrin- and caveolin-dependent endocytosis showed inhibitory effects on FITC-protamine association. Pretreatment with heparinase III partially but significantly decreased the association of FITC-protamine. These results suggest that protamine may be taken up by OK cells via receptor-mediated endocytosis, which may result in its localization in the cytoplasm and nucleus of the cells.
Assuntos
Células Epiteliais/metabolismo , Antagonistas de Heparina/metabolismo , Rim/citologia , Protaminas/metabolismo , Animais , Células Cultivadas , Endocitose , Fluoresceína-5-Isotiocianato , Corantes Fluorescentes , Masculino , Microvilosidades/metabolismo , Gambás , Ratos , Ratos WistarRESUMO
The Acetyl Salicylic Elimination Trial (ASET) Japan pilot study is a multicentre, single-arm, open-label, proof-of-concept study with a stopping rule based on the occurrence of definite stent thrombosis. This study aims to demonstrate the feasibility and safety of low-dose prasugrel monotherapy following percutaneous coronary intervention (PCI) in Japanese patients presenting with chronic coronary syndromes (CCS) or non-ST-elevation acute coronary syndromes (NSTE-ACS). Four hundred patients with a SYNTAX score <23 requiring PCI due to CCS or NSTE-ACS will be screened and considered eligible for the study. The enrolment is planned in two phases: 1) 200 patients presenting with CCS, followed by 2) 200 patients presenting with NSTE-ACS. After optimal PCI with implantation of a SYNERGY (Boston Scientific) stent, patients will be enrolled and loaded with prasugrel 20 mg, followed by a maintenance dose of prasugrel 3.75 mg once daily without aspirin continued for 3 months in Phase 1 (CCS patients), and for 12 months in Phase 2 (NSTE-ACS patients). After these follow-up periods, prasugrel will be replaced by standard antiplatelet therapy according to local practice. The primary endpoint is a composite of cardiac death, target vessel myocardial infarction, or definite stent thrombosis after the index procedure. The primary bleeding endpoint is any Bleeding Academic Research Consortium type 3 or 5 bleeding occurring within 3 months of the index PCI for CCS patients, or 12 months for NSTE-ACS patients. The ASET Japan study is designed to demonstrate the feasibility and safety of reduced-dose prasugrel monotherapy after PCI in East Asian patients with acute and chronic coronary syndromes.
RESUMO
BACKGROUND: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI. AIMS: The aim of this study was to assess the relationship between preprocedural pathophysiological haemodynamic patterns and intracoronary imaging findings, as well as their association with physiological outcomes immediately post-PCI. METHODS: Data from 206 patients with chronic coronary syndrome enrolled in the ASET-JAPAN study were analysed. Pathophysiological CAD patterns were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the pullback pressure gradient (PPG) index. Intracoronary imaging in stented segments after stent optimisation was also analysed. RESULTS: In the multivariable analysis, diffuse disease - defined by the pre-PCI µQFR-PPG index - was an independent factor for predicting a post-PCI µQFR <0.91 (per 0.1 decrease of PPG index, odds ratio 1.57, 95% confidence interval: 1.07-2.34; p=0.022), whereas the stent expansion index (EI) was not associated with a suboptimal post-PCI µQFR. Among vessels with an EI ≥80% and post-PCI µQFR <0.91, 84.0% of those vessels had a diffuse pattern preprocedure. There was no significant difference in EI between vessels with diffuse disease and those with focal disease. The average plaque burden in the stented segment was significantly larger in vessels with a preprocedural diffuse CAD pattern. CONCLUSIONS: A physiological diffuse pattern preprocedure was an independent factor in predicting unfavourable immediate haemodynamic outcomes post-PCI, even after stent optimisation using intracoronary imaging. Preprocedural assessment of CAD patterns could identify patients who are likely to exhibit superior immediate haemodynamic outcomes following PCI.