Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Artif Organs ; 27(1): 69-72, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36807033

RESUMO

A 47-year-old woman with dilated cardiomyopathy underwent HeartMate II (HM2) implantation as a bridge-to-transplantation. Her postoperative course was good. However, 2.5 years after surgery, the outflow graft was found to be twisted and the graft and pump was exchanged. While HeartMate 3(HM3) twisting of the outflow graft is well documented, such malfunctions in HM2 are almost unknown. Although HM2 has since been discontinued, there are a significant number of patients using HM2 who are awaiting heart transplants or destination therapy. We caution that, even with HM2, the possibility of late-phase twisting requires vigilance.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos
2.
J Artif Organs ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916826

RESUMO

Biological valves are becoming more frequently used in aortic valve replacement. While several reports have evaluated the performance of biological valves, echocardiography studies during exercise stress remain scarce. Furthermore, no current reports compare rate changes in the aortic valve area of biological valves under increased exercise load. Here, we performed exercise stress echocardiography in patients after AVR with Trifecta or Inspiris valves and compared the rates of change in aortic valve areas (AVA). In addition, hydrodynamic analysis at rest was conducted with four-dimensional flow magnetic resonance imaging (4D-flow MRI). Exercise stress echocardiography was performed in seven Trifecta and seven Inspiris patients who underwent AVR at our hospital while 4D flow MRI was performed in all but two Trifecta cases. Comparing the percentage change in AVA when loaded to 25 W versus at rest, Trifecta was greater than Inspiris (28.7 ± 36.0 vs - 0.8 ± 12.4%). The smaller AVA at rest was considered causative for this. Meanwhile, Trifecta systolic energy loss in the prosthetic valve segment on 4D-flow MRI (97.5 ± 35.9 vs 52.7 ± 25.3 mW) was higher than Inspiris. The opening of the Trifecta valve was considered to be restricted at rest and this may reflect the current reports of early valve degradation requiring reoperation. Taken together, we observed that the Trifecta design may promote faster wear due to higher valve stress.

3.
J Card Surg ; 37(12): 5616-5618, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378943

RESUMO

Coronary anatomy is key for arterial switch operations as reimplantation for coronary artery patterns originating from the same sinus is often challenging. We experienced an extremely rare coronary artery anatomy case (Leiden convention: 1 R, 1LCx) and successfully performed an arterial switch operation with coronary button extension and neo-pulmonary trunk realignment maneuver.


Assuntos
Transposição das Grandes Artérias , Anomalias dos Vasos Coronários , Transposição dos Grandes Vasos , Humanos , Transposição dos Grandes Vasos/cirurgia , Coração , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/anatomia & histologia , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia
4.
J Card Surg ; 37(6): 1716-1717, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35353382

RESUMO

Residual tumor mass after large cardiac fibroma resection carries long-term risk, but cryoablation is useful during surgery to remove such tissue. Here, we present a case of a large cardiac fibroma of the posterior wall of the left ventricle, discovered during long-term, episodic ventricular tachycardia. Resection with cryoablation completely removed the tumor, eliminating postoperative, distant ventricular arrhythmias.


Assuntos
Criocirurgia , Fibroma , Neoplasias Cardíacas , Taquicardia Ventricular , Fibroma/diagnóstico por imagem , Fibroma/patologia , Fibroma/cirurgia , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/cirurgia , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
5.
J Card Surg ; 37(4): 1069-1071, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35066940

RESUMO

Thin, metallic wires can easily penetrate the gastrointestinal system if ingested and cause serious cardiac issues in children. We report a pediatric case of such an object that caused cardiac tamponade after lodging in the left ventricle. The wire was extracted without cardiopulmonary bypass and a full recovery was made. Cardiac issues after ingestion of foreign objects are rare but immediate surgery is required for resolution.


Assuntos
Tamponamento Cardíaco , Corpos Estranhos , Migração de Corpo Estranho , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Criança , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Migração de Corpo Estranho/cirurgia , Ventrículos do Coração , Humanos
6.
Surg Today ; 2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36348164

RESUMO

Surgical intervention creates reactive oxygen species through diverse molecular mechanisms, including direct stimulation of immune-mediated inflammation necessary for wound healing. However, dysregulation of redox homeostasis in surgical patients overwhelms the endogenous defense system, slowing the healing process and damaging organs. We broadly surveyed reactive oxygen species that result from surgical interventions and the endogenous and/or exogenous antioxidants that control them. This study assimilates current reports on surgical sources of reactive oxygen and nitrogen species along with literature reports on the effects of endogenous and exogenous antioxidants in human, animal, and clinical settings. Although exogenous antioxidants are generally beneficial, endogenous antioxidant systems account for over 80% of total activity, varying based on patient age, sex, and health or co-morbidity status, especially in smokers, the diabetic, and the obese. Supplementation of exogenous compounds for support in surgical patients is thus theoretically beneficial, but a lack of persuasive clinical evidence has left this potential patient support strategy without clear guidelines. A more thorough understanding of the mechanisms of exogenous antioxidants in patients with compromised health statuses and pharmacokinetic profiling may increase the utility of such support in both the operating and recovery rooms.

7.
Heart Surg Forum ; 25(3): E459-E461, 2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35787747

RESUMO

Myxoma is the most common benign cardiac tumor. Absent pulmonary valves, often treated surgically in childhood, are associated with 3-6% of tetralogy of Fallot. It is unusual for absent pulmonary valves without other congenital heart diseases to be asymptomatic until adulthood. Here, we report the unique case of an 80-year-old female with right ventricular outflow tract myxoma and absent pulmonary valve that has, to our knowledge, never been reported. We successfully performed a simple mass resection and pulmonary valve implantation.


Assuntos
Mixoma , Atresia Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Adulto , Idoso de 80 Anos ou mais , Feminino , Humanos , Mixoma/complicações , Mixoma/diagnóstico , Mixoma/cirurgia , Valva Pulmonar/anormalidades , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
8.
J Card Surg ; 36(8): 2836-2849, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33908656

RESUMO

BACKGROUND: Great variability exists in repair strategies for the tetralogy of Fallot. While transannular patching, as introduced by Kirklin, was a breakthrough for primary repair, pulmonary regurgitation and a need for reoperation have led to the development of methods that preserve the natural morphology of the right ventricular outflow tract. METHODS: State-of-the-art details of tetralogy of Fallot repair are explained from the standpoint of architectural preservation, especially with regard to sparing native tissue such as the annulus, valve, or infundibulum. Particular attention is given to the latest technical details of each approach, benefits and disadvantages, and any long-term data available. RESULTS: The choice of procedure is complex and unique to each case as transannular patching alone may carry long-term pulmonary risks. Modifications that spare the annulus, valves, or infundibulum may thus be essential as preservation of natural morphology has resulted in excellent mid-term results. CONCLUSIONS: The complexity of tetralogy of Fallot repair demands constant attention to clinical presentation and vigilance against long-term sequelae. Techniques will continue to improve over time as long-term data guides the refinement of these innovative surgical methods.


Assuntos
Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Lactente , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Reoperação , Estudos Retrospectivos , Tetralogia de Fallot/cirurgia , Preservação de Tecido , Resultado do Tratamento
9.
Heart Surg Forum ; 24(2): E231-E232, 2021 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-33798051

RESUMO

A 57-year-old female with Loeys-Dietz syndrome type 3 and MYH11 gene mutation underwent unexpected intraoperative ascending aortic dissection and subsequent rapid progression of the aortic arch dissecting aneurysm. Intra-surgical contingency plans with regard to aortic dissection and aneurysm should be considered for Loeys-Dietz syndrome, especially with comorbid mutations.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , DNA/genética , Síndrome de Loeys-Dietz/complicações , Mutação , Cadeias Pesadas de Miosina/genética , Procedimentos Cirúrgicos Vasculares/métodos , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/etiologia , Análise Mutacional de DNA , Ecocardiografia , Feminino , Humanos , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/genética , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
10.
Am J Respir Cell Mol Biol ; 63(6): 843-855, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32915674

RESUMO

The potential benefit of heart rate reduction (HRR), independent of ß-blockade, on right ventricular (RV) function in pulmonary hypertension (PH) remains undecided. We studied HRR effects on RV fibrosis and function in PH and RV pressure-loading models. Adult rats were randomized to 1) sham controls, 2) monocrotaline (MCT)-induced PH, 3) SU5416 + hypoxia (SUHX)-induced PH, or 4) pulmonary artery banding (PAB). Ivabradine (IVA) (10 mg/kg/d) was administered from 2 weeks after PH induction or PAB. Exercise tolerance, echocardiography, and pressure-volume hemodynamics were obtained at a terminal experiment 3 weeks later. RV myocardial samples were analyzed for putative mechanisms of HRR effects through fibrosis, profibrotic molecular signaling, and Ca++ handling. The effects of IVA versus carvedilol on human induced pluripotent stem cell-derived cardiomyocytes beat rate and relaxation properties were evaluated in vitro. Despite unabated severely elevated RV systolic pressures, IVA improved RV systolic and diastolic function, profibrotic signaling, and RV fibrosis in PH/PAB rats. RV systolic-elastance (control, 121 ± 116; MCT, 49 ± 36 vs. MCT+IVA, 120 ± 54; PAB, 70 ± 20 vs. PAB+IVA, 168 ± 76; SUHX, 86 ± 56 vs. SUHX +IVA, 218 ± 111; all P < 0.05), the time constant of RV relaxation, echo indices of RV function, and fibrosis (fibrosis: control, 4.6 ± 1%; MCT, 13.4 ± 6.5 vs. MCT+IVA, 6.7 ± 2.6%; PAB, 11.4 ± 4.5 vs. PAB+IVA, 6.4 ± 5.1%; SUHX, 10 ± 4.6 vs. SUHX+IVA, 3.9 ± 2.2%; all P < 0.001) were improved by IVA versus controls. IVA had a dose-response effect on induced pluripotent stem cell-derived cardiomyocytes beat rate by delaying Ca++ loss from the cytoplasm. In experimental PH or RV pressure loading, HRR improves RV fibrosis, function, and exercise endurance independent of ß-blockade. The balance between adverse tachycardia and bradycardia requires further study, but judicious HRR may provide a promising strategy to improve RV function in clinical PH.


Assuntos
Frequência Cardíaca/efeitos dos fármacos , Hipertensão Pulmonar/induzido quimicamente , Ivabradina/farmacologia , Função Ventricular Direita/efeitos dos fármacos , Animais , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Hipertensão Pulmonar/patologia , Células-Tronco Pluripotentes Induzidas/efeitos dos fármacos , Artéria Pulmonar/fisiopatologia , Ratos Sprague-Dawley , Pressão Ventricular/efeitos dos fármacos
11.
Pediatr Crit Care Med ; 21(5): e267-e273, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32106186

RESUMO

OBJECTIVES: To examine validity and reliability of the Japanese version of the Cornell Assessment of Pediatric Delirium. DESIGN: Prospective double-blinded observational cohort study. SETTING: Eight-bed mixed PICU (post-surgical and internal medicine) from May 2017 to June 2018. PATIENTS: All children between the ages of 0-13 years who were admitted to the PICU for at least 24 hours were eligible for inclusion, as long as the child was arousable to verbal stimulation. INTERVENTIONS: Two nurses simultaneously and independently assessed each patient for pediatric delirium with the Japanese version of the Cornell Assessment of Pediatric Delirium; this was compared to the gold standard of psychiatric diagnosis based on Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition standards. MEASUREMENTS AND MAIN RESULTS: Forty-one children were enrolled and 92 assessments (ranging from one to four per subject) were completed. Congenital heart disease patients accounted for 73 enrollees (79%). Forty-three percent of observations were performed in children on invasive mechanical ventilation. Pediatric delirium prevalence (as determined by psychiatric diagnosis) was 53%. The Japanese version of the Cornell Assessment of Pediatric Delirium demonstrated an optimal scoring cutpoint of 9. Overall, area under the curve was 92%, sensitivity 90% (95% CI, 79-97%), specificity 88% (95% CI, 75-96%), positive predictive value of 90% (95% CI, 79-97%), negative predictive value of 91% (95% CI, 80-97%), and a Cohen's κ of 0.89 (95% CI, 0.8-0.98). In children on invasive mechanical ventilation, the Japanese version of the Cornell Assessment of Pediatric Delirium maintained an area under the curve 87%, sensitivity 97%, and specificity 64%. CONCLUSIONS: The Japanese version of the Cornell Assessment of Pediatric Delirium is a valid and reliable tool for use in Japanese PICUs. This will allow for detection of delirium in real-time and may lead to better identification of the population and risk factors for appropriate management and therapeutic and preventative interventions.


Assuntos
Delírio , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Delírio/diagnóstico , Humanos , Lactente , Recém-Nascido , Japão , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Pediatr Cardiol ; 41(5): 932-938, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32170329

RESUMO

A restrictive blood transfusion strategy has emerged in adult cardiac surgery. However, the feasibility in children is poorly investigated. 352 consecutive patients undergoing open-heart surgery were retrospectively reviewed, excluding patients requiring extracorporeal membrane oxygenation. Patient demographics, perioperative blood product usage, and clinical outcome parameters were investigated. Variables predicting the need for blood products were delineated. Of the 352 study patients, 148 patients (42%) underwent bloodless surgery and 204 (58%) were transfused. Of the 204 transfused patients, 170 (83.4%) patients received one blood transfusion and 34 (16.6%) received two or more blood transfusions. Patient's weight and preoperative hematocrit (Hct) were statistically significant in predicting the need for blood priming the CPB circuit (AUC 0.99, p < 0.001, sensitivity 96.6%, specificity 95.2%). A body weight of 8.5 kg carried a sensitivity of 100% and specificity of 94.5% (p < 0.001) for a blood prime. Among patients with a weight less than 8.5 kg (n = 171), only 27 patients (15.8%, p < 0.001) required additional transfusion of PRBCs. Factors impacting the need for a blood transfusion during CPB included redo surgery [odds ratio (OR) 4.61, p = 0.001] and the highest lactate level on CPB (OR 1.65, p = 0.006). Redo surgery had the highest impact (OR 7.27, p = 0.012) for requiring a postoperative PRBC transfusion. A restrictive transfusion strategy can be safely implemented in pediatric cardiac surgery. The majority of children with a BW > 8.5 kg required no blood products and those with a BW ≤ 8.5 kg required only 1 unit of blood, to prime the cardiopulmonary bypass circuit.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Transfusão de Eritrócitos/estatística & dados numéricos , Cardiopatias Congênitas/cirurgia , Peso Corporal , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos
13.
J Card Surg ; 35(6): 1354-1356, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32302025

RESUMO

BACKGROUND AND AIM: Cardiopulmonary bypass (CPB) in antiphospholipid syndrome (APS) patients carries a high risk of thrombosis and hemorrhage. However, optimal anticoagulation surveillance methods have not been established and heparin optimization has not yet been totally validated as reflective of anticoagulation status. METHODS AND RESULT: Here, a 45-year-old female with APS underwent mitral valvuloplasty due to infective endocarditis. We used a perioperative, in vitro, heparin-activated clotting time (ACT) titration line coupled with synergistic, intraoperative thromboelastography (TEG) to monitor coagulation activity. After the ACT target was reached, TEG monitored the suppression of both intrinsic and extrinsic coagulation activity throughout the surgery. CONCLUSION: TEG thus provided valuable temporal information on both intrinsic and extrinsic coagulation suppression validating heparin-ACT titration targets.


Assuntos
Anticoagulantes/administração & dosagem , Síndrome Antifosfolipídica/complicações , Ponte Cardiopulmonar/efeitos adversos , Heparina/administração & dosagem , Monitorização Intraoperatória/métodos , Tromboelastografia , Trombose/etiologia , Trombose/prevenção & controle , Coagulação Sanguínea , Endocardite/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral , Trombose/sangue , Tempo de Coagulação do Sangue Total
14.
Artigo em Japonês | MEDLINE | ID: mdl-32201418

RESUMO

This study was designed to clarify the relation between the pressure resistance of an angiographical tube and the amount of contrast medium injected under a connected microcatheter used for interventional radiology (IVR). We investigated the injection pressure and the expansion rate at the center of the tube during contrast enhancement by setting the power injector to 1200 PSI pressure, with 2.0 ml/s injection speed, 10 ml injection volume, 5.0 s injection time, and 0 s rise time for tubes with different pressure resistance performance (low or high). Then we examined the amount of contrast medium material discharged from the microcatheter. The low-pressure resistant tube (less than 140 PSI) injection pressure exceeded the pressure performance. The expansion rate increased to 49%, presenting a risk of rupture. The injection pressure of the high-pressure resistant tube (less than 1200 PSI) was within the pressure-resistance performance. The expansion rate increased to 38%. However, when the contrast medium discharge amount contributing to the image was measured within the injection time under the condition of 10 ml injection for 5.0 s, the former was 2.3 ml and the latter was 4.2 ml. The entire amount was not discharged during the injection period. It became apparent that it is discharged in drips after some time. Results show that the tube expansion caused retention of the contrast medium inside, which decreases the actual amount of the injected contrast medium. From the results, we infer the possibility of preventing reduction of the injected contrast medium amount attributable to expansion.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Angiografia , Injeções , Radiologia Intervencionista
15.
Artigo em Japonês | MEDLINE | ID: mdl-32074530

RESUMO

Japanese Diagnostic Reference Levels (DRLs) were released as "Japan DRLs 2015" from Japan Network for Research and Information on Medical Exposure (J-RIME) in June 2015. In "Japan DRLs 2015", DRLs in angiography and interventional procedures are set at a fluoroscopic dose rate of 20 mGy/min at the interventional reference point using a phantom. In order to achieve optimization with DRLs, then it need to be revised regularly. Therefore, we (research group to examine the effect of Japan DRLs 2015 and the necessity of additional items in angiography and vascular interventions) examined the effects of "Japan DRLs 2015" on angiography and interventional procedures. And we also investigated for DRLs revision in the future. As a result, it turned out that it is important to create DRLs in medical procedures that can be effectively used in clinical settings.


Assuntos
Angiografia , Imagens de Fantasmas , Humanos , Japão , Doses de Radiação , Valores de Referência
17.
J Card Surg ; 34(9): 877-879, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31269268

RESUMO

A 57-year old male with a dual-chamber pacemaker and 40-year history of hemodialysis and autoinflammatory disease developed a large, 35 × 35 mm intracardiac vegetation on the right ventricular pacing lead. As this mass was large enough to occlude the tricuspid valve orifice, transvenous lead extraction was deemed unsuitable. Instead, an urgent surgical extraction of the whole pacemaker system, including leads and vegetation, was conducted under cardiopulmonary bypass. In light of a high risk of recurrent blood infection, a new dual-chamber pacing system was then immediately re-established using epicardial pacing leads on the right atrium and ventricle instead of transvenous electrodes. This case of a rare, giant intracardiac lead vegetation lacked most known causal factors, except for renal failure, but a possibly immunosuppressed cardiac microenvironment due to long-term steroid therapy may have been an important influencing factor.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Ponte Cardiopulmonar/métodos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Estafilocócicas/cirurgia , Ecocardiografia , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/microbiologia , Pericárdio , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Reimplante/métodos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Staphylococcus epidermidis/isolamento & purificação
18.
J Card Surg ; 34(11): 1405-1407, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31475758

RESUMO

While a coronary artery fistula with aneurysmal formation is rare, a fistula/aneurysm combination occurring in single coronary artery is even rarer. Here, we report the successful surgical correction of a right ventricular fistula with a large aneurysm of 30 mm and a daughter aneurysm within a case of single coronary artery.


Assuntos
Aneurisma Coronário/cirurgia , Doença da Artéria Coronariana/cirurgia , Fístula/cirurgia , Ventrículos do Coração
19.
J Card Surg ; 34(6): 511-513, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31017327

RESUMO

A 75-year-old woman presented at a prior hospital with persistent cough and was treated conservatively for a thrombosed-type aortic dissection (Stanford A). One-year after discharge, follow-up computerized tomography revealed a DeBakey type II, chronic dissecting aortic aneurysm enlarged to 54 mm. She was referred to our hospital with slight edema in the face and extremities and chest radiography showed calcification around the heart. Computerized tomography performed at the prior hospital showed a large spherical mass in the anterior pericardium in addition to the aortic dissection. We therefore resected the mass immediately before a total aortic arch replacement. Surgery was successful and uneventful with patient discharge on postoperative day 21. The final differential diagnosis was idiopathic, localized, constrictive pericarditis.


Assuntos
Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Calcinose/cirurgia , Cardiomiopatias/cirurgia , Pericardite Constritiva/complicações , Pericardite Constritiva/cirurgia , Pericárdio/cirurgia , Idoso , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Calcinose/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Doença Crônica , Feminino , Humanos , Pericardite Constritiva/patologia , Pericárdio/diagnóstico por imagem , Pericárdio/patologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Pediatr Crit Care Med ; 19(8): 713-717, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29677032

RESUMO

OBJECTIVES: Junctional ectopic tachycardia is a supraventricular tachyarrhythmia with atrioventricular dissociation that causes life-threatening postsurgical conditions in pediatric heart patients. This study evaluates the efficacy of landiolol hydrochloride for managing junctional ectopic tachycardia. DESIGN: A single-center retrospective study. SETTING: PICU at the university hospital. PATIENTS: Of 561 pediatric patients who underwent open-heart surgery between 2006 and 2017, 10 patients developed sustained junctional ectopic tachycardia and were selected for landiolol treatment. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Landiolol decreased mean heart rate significantly from 206.1 ± 14.5 to 158.0 ± 8.6 beats/min within 2 hours after administration (p < 0.01). Mean time to achieve 20% heart rate reduction was 2.1 ± 0.5 hours. Systolic blood pressure between pre and post landiolol administration did not change significantly (72.6 ± 5.9 to 79.7 ± 6.2 mm Hg). Once junctional heart rate was sufficiently suppressed, atrioventricular sequential pacing was introduced to stabilize hemodynamics. Nine of 10 cases (90%) had atrioventricular sequential pacing to maintain appropriate heart rate and restore atrioventricular synchronicity under suppressed junctional heart rate. Subsequently, eight of 10 cases (80%) were converted to regular sinus rhythm within 24 hours after starting landiolol administration. The average time to achieve sinus rhythm conversion was 7.9 ± 3.4 hours. CONCLUSIONS: Landiolol rapidly suppresses junctional heart rate in junctional ectopic tachycardia after pediatric heart surgery without significant blood pressure compromises. Subsequent atrioventricular sequential pacing was effective at restoring atrioventricular synchronicity and stabilizing hemodynamics. Combining junctional rate control with landiolol and atrioventricular sequential pacing is therefore suggested as a promising option for prompt management of postoperative junctional ectopic tachycardia.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Cardiopatias Congênitas/cirurgia , Frequência Cardíaca/efeitos dos fármacos , Morfolinas/administração & dosagem , Complicações Pós-Operatórias/tratamento farmacológico , Taquicardia Ectópica de Junção/tratamento farmacológico , Ureia/análogos & derivados , Antagonistas Adrenérgicos beta/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica , Masculino , Morfolinas/farmacologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Taquicardia Ectópica de Junção/etiologia , Fatores de Tempo , Ureia/administração & dosagem , Ureia/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA