Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(5): 1130-1140, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37102590

RESUMO

INTRODUCTION: Various adjunctive approaches to pulmonary vein isolation (PVI) have been attempted for persistent atrial fibrillation (perAF) and longstanding persistent AF (ls-perAF). We aimed to identify the novel zones responsible for perpetuation of AF. METHODS: To identify novel zones acting as a source of perAF and ls-perAF after PVI/re-PVI, we performed fractionation mapping in 258 consecutive patients with perAF (n = 207) and ls-perAF (n = 51) in whom PVI/re-PVI failed to restore sinus rhythm. RESULTS: In 15 patients with perAF (5.8%: 15/258), fractionation mapping identified a small solitary zone (<1 cm2 ) with high-frequency and irregular waves, showing fractionated electrograms (EGM). We defined this zone as the small solitary atrial fractionated EGM (SAFE) zone. The small SAFE zone was surrounded characteristically by a homogeneous area showing relatively organized activation with nonrapid and nonfractionated waves. Only one small SAFE zone was detected in each patient. This characteristic electrical phenomenon was observed stably during the procedure until ablation. AF duration, (defined as the duration between initial detection of AF and the current ablation) was longer in patients with the small SAFE zone than in those without (median, [25 and 75 percentiles]; 5.0 [3.5, 7.0] vs. 1.1 [1.0, 4.0] years, p = .0008). Longer AF cycle length was observed in patients with the small SAFE zone than in those without. The ablation of the small SAFE zone terminated AF in all 15 patients without any need for other ablations. AF/atrial tachycardia-free rate at follow-up was 93% (14/15) at 6 months, 87% (13/15) at 1 year, and 60% (9/15) at 2 years. CONCLUSIONS: Using fractionation mapping, this study identified a small SAFE zone surrounded characteristically by a homogeneous, relatively organized, low-excitability EGM lesion. The ablation of the small SAFE zone terminated AF in all patients, demonstrating it as a substrate for perpetuated AF. Our findings provide novel ablation targets in perAF patients with prolonged AF duration. Further studies to confirm the present results are warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Recidiva
2.
Int J Cardiovasc Imaging ; 39(12): 2517-2526, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37646891

RESUMO

Enhanced computed tomography (CT) is unsuitable for patients with reduced renal function and/or allergy for contrast medium (CM). CT image registration into an electroanatomic system (EAMS) is essential to perform pulmonary vein isolation (PVI) safely and smoothly in patients with atrial fibrillation (AF). To create three-dimensional pulmonary vein-left atrium (3D PV-LA) images from non-enhanced CT images to register them into EAMS for AF ablation. Using a non-enhanced ECG-gated image, 3D PV-LA images were generated by our developed techniques with an EnSite image analyzing tool for patients unfit for CM use (n = 100). Segmentation between tissues was performed as follows: tissues distal from or close to PV-LA were segmented in transverse slices to clearly show the whole LA. Tissues bordering PV-LA, including the pulmonary artery, left ventricle, and right atrium, were segmented manually with great care. Practical ablation parameters were compared with those obtained from enhanced CT (n = 100). 3D PV-LA image reconstruction from non-enhanced CT imaging required a longer time than that from enhanced CT (42 ± 6 vs 14 ± 3 min). All 100 PV-LA non-enhanced CT images were successfully reconstructed and registered into the EAM system without the need for re-segmentation. Practical ablation parameters, including procedural time and AF recurrence rate, did not differ between imaging methods. This study provides clinically useful information on a detailed methodology for 3D PV-LA image reconstruction using non-enhanced CT. Non-enhanced CT 3D PV-LA images were successfully registered into the EAM system and useful for patients unsuitable for CM use.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento , Valor Preditivo dos Testes , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imageamento Tridimensional/métodos , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA