Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(7): 1596-1598, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35612359

RESUMO

It has been shown that endocardial occlusion of the left atrial appendage (LAA) is equally effective in preventing embolic events compared to oral anticoagulation in patients with nonvalvular atrial fibrillation. An 82-year-old female patient was admitted for LAA occlusion for repetitive GI bleeding. She had high CHADSVASC Score and HASBLED with long persistent atrial fibrillation with many comorbities. The preprocedural transesophageal echo revealed a great mass in the left atrium (Picture 1). Cardiac surgery was denied, we performed an epicardial only ligation for closing the LAA. For this approach we performed an epicardial puncture and contrast injection within the pericardial space to delineate the LAA. An epicardial wire with a suction mechanism at its distal end was attached to the anterior lobe of the LAA. Using this epicardial wire the snare could be advanced over the appendage and closed down. Complete exclusion of the LAA was achieved. There were no procedural complications and the patient is doing well after 3 months.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Ligadura , Resultado do Tratamento
2.
Cardiology ; 146(3): 304-310, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33691308

RESUMO

INTRODUCTION: Since 2008, specialized chest pain units (CPUs) were implemented across Germany ensuring structured diagnostics in acute chest pain. This study aims to analyze the management of pulmonary embolism (PE) patients in such certified CPUs. METHODS: Data were retrieved from 13,902 patients enrolled in the German CPU registry and analyzed for the diagnosis of PE including patient characteristics, critical time intervals, diagnostic workup, treatment, and prognosis. PE patients were compared to the overall CPU patient cohort. Only patients with a complete 3-month follow-up were included. RESULTS: Overall, 1.1% of all CPU patients were diagnosed with PE. Chest pain and dyspnea were the leading symptoms. Patients with PE were older, presented with higher heart rates, and more frequently exhibited signs of heart failure, despite a normal left ventricular function. PE patients showed significantly longer time delays between symptom onset and the first medical contact, while PE patients with chest pain presented earlier than PE patients with dyspnea only. Whereas more PE patients had to be transferred to the intensive care unit, in-CPU mortality and event rates over 3 months were low. DISCUSSION/CONCLUSION: This study suggests a certain risk for underdiagnosis and consecutive potential undertreatment of PE patients in German Cardiac Society (GCS)-certified CPUs, which is thought to result from an anticipated focus on patients with acute coronary syndrome (ACS). Public awareness for PE beyond chest pain should be improved. Certified CPUs should be urged to implement strategic pathways for a better simultaneous diagnostic workup of differential diagnosis beyond ACS.


Assuntos
Síndrome Coronariana Aguda , Embolia Pulmonar , Dor no Peito/diagnóstico , Dor no Peito/epidemiologia , Dor no Peito/etiologia , Alemanha/epidemiologia , Humanos , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/terapia , Sistema de Registros
3.
Indian Pacing Electrophysiol J ; 21(2): 75-79, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33460777

RESUMO

INTRODUCTION: We present initial results of patients undergoing a combined procedure of epicardial LAA ligation in addition to left atrial ablation for AF. METHODS: 9 patients were included for additional use of LARIAT as an individual treatment approach for AF. First an epicardial LAA ligation was performed, in the same procedure left atrial ablations consisting of PVI and additional substrate based modifying ablations were performed. Follow-up at 3 months and 12 months was performed. RESULTS: There was only 1 minor procedural complication (11%) involving epicardial bleeding and 2 late adverse events of pericardial tamponade and stroke. At the final follow-up (median 20 months) 7 patients were in stable sinus rhythm (78%) and 2 pts had reduced AF burden. CONCLUSION: Concomitant epicardial LAA ligation and ablation is feasible in selected patients with a reasonable risk profile. More prospective data are required to validate the safety and efficacy.

4.
Lancet ; 394(10209): 1619-1628, 2019 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-31570258

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the preferred treatment option for older patients with symptomatic severe aortic stenosis. Differences in the properties of available TAVR systems can affect clinical outcomes. Among patients undergoing TAVR, we compared the self-expanding ACURATE neo TAVR system with the balloon-expandable SAPIEN 3 TAVR system with regard to early safety and efficacy. METHODS: In this randomised non-inferiority trial, patients (aged ≥75 years) undergoing transfemoral TAVR for treatment of symptomatic severe aortic stenosis, and who were deemed to be at increased surgical risk, were recruited at 20 tertiary heart valve centres in Germany, the Netherlands, Switzerland, and the UK. Participants were randomly assigned (1:1) to receive treatment with the ACURATE neo or the SAPIEN 3 with a computer-based randomly permuted block scheme, stratified by study centre and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) category. The primary composite safety and efficacy endpoint comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days of the procedure. Endpoint assessors were masked to treatment allocation. Non-inferiority of ACURATE neo compared with SAPIEN 3 was assessed in the intention-to-treat population on the basis of a risk-difference margin of 7·7% for the primary composite endpoint, with a one-sided α of 0·05. This trial is registered with ClinicalTrials.gov (number NCT03011346) and is ongoing but not recruiting. FINDINGS: Between Feb 8, 2017, and Feb 2, 2019, up to 5132 patients were screened and 739 (mean age 82·8 years [SD 4·1]; median STS-PROM score 3·5% [IQR 2·6-5·0]) were enrolled. 30-day follow-up was available for 367 (99%) of 372 patients allocated to the ACURATE neo group, and 364 (99%) of 367 allocated to the SAPIEN 3 group. Within 30 days, the primary endpoint occurred in 87 (24%) patients in the ACURATE neo and in 60 (16%) in the SAPIEN 3 group; thus, non-inferiority of the ACURATE neo was not met (absolute risk difference 7·1% [upper 95% confidence limit 12·0%], p=0·42). Secondary analysis of the primary endpoint suggested superiority of the SAPIEN 3 device over the ACURATE neo device (95% CI for risk difference -1·3 to -12·9, p=0·0156). The ACURATE neo and SAPIEN 3 groups did not differ in incidence of all-cause death (nine patients [2%] vs three [1%]) and stroke (seven [2%] vs 11 [3%]); whereas acute kidney injury (11 [3%] vs three [1%]) and moderate or severe prosthetic aortic regurgitation (34 [9%] vs ten [3%]) were more common in the ACURATE neo group. INTERPRETATION: TAVR with the self-expanding ACURATE neo did not meet non-inferiority compared to the balloon-expandable SAPIEN 3 device in terms of early safety and clinical efficacy outcomes. An early composite safety and efficacy endpoint was useful in discriminating the performance of different TAVR systems. FUNDING: Boston Scientific (USA).


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Feminino , Alemanha/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Países Baixos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Índice de Gravidade de Doença , Suíça/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido/epidemiologia
6.
J Interv Cardiol ; 2020: 6542028, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32934608

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a highly prevalent comorbidity in patients with severe mitral valve regurgitation (MR). Recent studies show a deleterious outcome of patients with concomitant AF after transcatheter mitral valve repair (TMVR). This underlines the essential need for additional strategies that ameliorate the prognosis of these patients. Fundamental data on AF characteristics and treatment regimes in this special cohort of patients are lacking. METHODS: We retrospectively analyzed the data of 542 consecutive patients with severe MR undergoing TMVR in three tertiary heart centers with special focus on AF type and underlying treatment strategies. RESULTS: The prevalence of concomitant AF was 73.3%, and AF did not affect the procedural success or the incidence of major adverse cardiac and cerebrovascular events. The patients with AF were more frequently >75 years, had more tricuspid regurgitation, and less coronary artery disease than non-AF patients. The distribution of AF types was 32% paroxysmal AF, 27% persistent AF, and 41% permanent AF. Except for a higher degree in severe tricuspid regurgitation and a higher likelihood of male sex, no substantial differences were observed while comparing permanent and nonpermanent AF patients. The predominant treatment regime was rate control (57%), with only beta blockers (BB) in the majority of persistent and permanent AF patients, while additional digitalis or a pacemaker was used infrequently. Rhythm control was mainly achieved with BB alone in paroxysmal AF patients and with additional antiarrhythmic drugs in the majority of persistent AF patients. Interventional rhythm control therapy was performed in 2.5% and 30.9% of paroxysmal and persistent AF patients, respectively. The guideline-adherent use of oral anticoagulants was comparable and high in both groups (91.9% in nonpermanent vs. 90.1% in permanent AF). CONCLUSION: This is the first study to provide necessary information for the understanding of the current clinical practice in dealing with TMVR patients. Since evidence suggests that AF is not a benign concomitant disease, further investigations are needed to assess the prognostic impact of these different AF treatment strategies.


Assuntos
Antiarrítmicos , Anticoagulantes , Fibrilação Atrial , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Cateterismo Cardíaco/métodos , Comorbidade , Feminino , Humanos , Masculino , Conduta do Tratamento Medicamentoso , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Fatores de Risco , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 94(3): 469-478, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30866154

RESUMO

AIMS: We aimed to assess whether the level of aortic root calcification is associated with BAV performance/omission during transcatheter aortic valve implantation (TAVI), and to explore related outcomes. METHODS AND RESULTS: EASE-IT TF was a prospective, observational, multicenter registry of patients undergoing TF-TAVI with the Edwards SAPIEN 3, with or without BAV predilation. Valvular calcification was quantified from pre-procedural multi-slice computed tomography images and compared between BAV and no BAV patients. Data for 178 patients (55 BAV; 123 no BAV) were analyzed. There were no significant differences between groups in terms of regional/leaflet sector calcification volumes, maximum asymmetry between the different leaflet sectors, or total calcification scores. Overall, a greater-than-average leaflet calcification volume was independently predictive of ≥mild PVL (OR: 5.116; 95% CI: 1.042-38.35) and the need for post-dilation (OR: 3.592; 95% CI: 1.173-12.14). The latter effect was abated in patients with BAV (OR: 1.837; 95% CI: 0.223-18.00) and intensified in those without BAV (OR: 5.575; 95% CI: 1.114-38.74). No other BAV-dependent effects of calcification on outcomes were observed. CONCLUSIONS: In the majority of transfemoral valve implantations, calcification does not appear to be the main driving factor in the decision to perform/omit BAV. Predilation may be valuable for reducing post-dilation requirements in patients only with a greater degree of leaflet calcification.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Calcinose/cirurgia , Cateterismo Periférico , Artéria Femoral , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Cateterismo Periférico/efeitos adversos , Tomada de Decisão Clínica , Feminino , Humanos , Masculino , Estudos Prospectivos , Punções , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Eur Radiol ; 28(8): 3432-3440, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29426987

RESUMO

OBJECTIVE: To compare image quality, observer confidence, radiation exposure in the standard-dose (SD-CCTA) and low-dose (LD-CCTA) protocols of coronary CT angiography (CCTA) in patients with atrial fibrillation (AF). MATERIAL AND METHODS: CCTA was performed in 303 patients using a CT scanner with 16-cm coverage (111 scans during sinus rhythm (SR); 192 during AF). LD-CCTA was used in 218 patients; SD-CCTA in 85 patients suspected of having coronary artery disease (CAD). Image quality and observer confidence were evaluated on 5-point scales. Radiation doses were recorded. RESULTS: Image quality was superior in the SD-CCTA compared to the LD-CCTA (SR 1.45±0.40; AF 1.72±0.46; vs. SR 1.83±0.48; AF 1.92±0.50; p < 0.001). Observers were more confident with SD-CCTA than with LD-CCTA (SR 1.38±0.33; AF 1.61±0.43; vs. SR 1.70±0.45; AF 1.82±0.50; p < 0.001). Radiation doses in AF were significantly higher than in the SR (LD-CCTA, 1.68±0.71 mSv; SD-CCTA, 3.72±1.95 mSv; vs. LD-CCTA, 1.3 ±0.52 mSv; SD-CCTA, 2.67±1.47 mSv; p < 0.001). CONCLUSION: Using a low-dose protocol in AF, radiation exposure can be decreased by 50 % at the expense of 20 % impaired image quality. A low-dose CCTA protocol can be considered in young patients, whereas the standard-dose protocol is recommended for older patients and those suspected of having CAD. KEY POINTS: • Whole-heart CT allows visualization of the coronary arteries in atrial fibrillation. • Low-dose CT decreases radiation exposure by 50%, image quality by 20%. • Standard-dose CT seems advantageous when concomitant coronary artery disease is suspected.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Doses de Radiação , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Exposição à Radiação
10.
Catheter Cardiovasc Interv ; 90(2): 313-320, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27649934

RESUMO

OBJECTIVES: We sought to determine the effects of experience on the Mitraclip® procedure steps as well as procedure safety and functional results. BACKGROUND: MR has proven deleterious in heart failure. Mitraclip® therapy evolved an important option in patients with severely reduced left ventricular function (LVEF). METHODS: Between 2011 and 2016, 126 consecutive patients were grouped in three groups and investigated in a prospective observational study. We evaluated the duration of procedural steps, safety endpoints, and functional results. RESULTS: The median logistic EuroScore was 32% (7-40%). Ninety-five percent of patients were in NYHA-stage ≥III and 51% had a LVEF <30%. Groups were homogeneous as to their baseline NYHA status and right heart catheterization data. Echocardiography data are comparable, albeit with a decreasing effective regurgitant orifice area (0.44 ± 0.21 group I vs. 0.34 ± 0.22 group III, P = 0.02). Frailty was less frequent and baseline 6 min walking test results improved from group I to group III. Duration of a first clip placement decreased from 106 ± 50 to 50 ± 21 min (P < 0.001). Total procedure time decreased from 221 ± 70 to 144 ± 68 (P < 0.001). The number of clips implanted increased from 66 to 79 (P = 0.02). MitraClip® implantation was effective in either group but the combined safety endpoint was reached less frequent in group III (P = 0.01). There was no difference in MACCE rate, 30 day- or intrahospital-mortality between groups. CONCLUSION: Safety and duration of procedure steps improved substantially with experience. MR reduction was sustained from the beginning without further improvement. Patient selection is a key factor for success. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Competência Clínica , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Ecocardiografia , Tolerância ao Exercício , Feminino , Alemanha , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Curva de Aprendizado , Modelos Logísticos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Teste de Caminhada
11.
Catheter Cardiovasc Interv ; 90(6): 1038-1045, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28568427

RESUMO

OBJECTIVES: This study sought to investigate whether the percutaneous mitral regurgitation (MR) reduction with the MitraClip® system in end-stage heart failure patients with a left ventricular ejection fraction (LVEF) of <20% also effects beneficial outcome or whether the underlying myogenic problem is leading and therefore of prognostic relevance. BACKROUND: The interventional treatment of functional mitral regurgitation (FMR) with the MitraClip® system could improve the clinical and hemodynamic outcome in patients with severely impaired left ventricular function. MATERIALS AND METHODS: Between 2011 and 2016, a total of 147 patients with FMR were treated with MitraClip® at our institution. The cohort was divided into two groups: LVEF ≥ 20% (N = 126) and <20% (N = 21). Follow-up assessments included exercise capacity, 6-min walk test, probrain natriuretic peptide-measurement (ProBNP), echocardiography and right heart catheterization. Only three patients with an LVEF ≥ 20% and one patient with an LVEF < 20% were lost for follow-up. RESULTS: In the vast majority of patients, a reduction from severe to mild MR was demonstrated with no difference between both groups (P = 0.422). At follow-up, both subgroups experienced similar improvements in exercise capacity and hemodynamics. Patients with an LVEF < 20% were on average 5.8 years younger, while mortality rates were comparable in both groups (P = 0.760). CONCLUSION: By careful selection, even patients in the end stage of advanced LV dysfunction as the result of the underlying myogenic problem and the additional harmful effects of the high volume loading due to the FMR can exhibit significant clinical and hemodynamic improvement after MitraClip© therapy.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Volume Sistólico/fisiologia , Instrumentos Cirúrgicos , Função Ventricular Esquerda/fisiologia , Idoso , Angiografia , Ecocardiografia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
12.
J Interv Cardiol ; 30(3): 217-225, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28439917

RESUMO

BACKGROUND: Aim of the study was to determine the impact of right- and left-ventricular systolic dysfunction on perioperative outcome and long-term survival after TAVR. METHODS: Study population consisted of 702 TAVRs between 2009 and 2014, 345 by TF, 357 by TA route. RV and LV function were determined by TAPSE and LVEF measurement during baseline echocardiography. Patients were divided according to TAPSE (>18 mm/14-18 mm/<14 mm) and LVEF (>50%/30-50%/<30%) tertiles. Outcome at day-30 and Kaplan-Meier 4-year survival were analyzed. RESULTS: Impaired RV and LV-function did not adversely affect mortality, stroke, bleeding, and vascular-complications at 30 days. Patients with TAPSE < 14 mm displayed elevated rate of renal failure requiring dialysis (11%; P < 0.01). Kaplan-Meier survival was adversely affected by RV-systolic dysfunction RVSD (P < 0.01). Multivariate analysis revealed that impaired RVSD but not LVSD was an independent determinant for late mortality (hazard ratio TAPSE 14-18 mm: 1.53; P = 0.02; TAPSE <14 mm: 2.12; P < 0.01). CONCLUSIONS: Peri-operative mortality and risk of stroke after TAVR are not adversely affected by preexisting RV or LV dysfunction. Long-term survival is impaired in patients with RVSD. RVSD but not LVSD is an independent risk factor for late mortality. TAVR should be the preferred therapy for patients with RVSD and LVSD, especially when patient is suitable for TF.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia/métodos , Feminino , Alemanha/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Efeitos Adversos de Longa Duração/mortalidade , Masculino , Modelos de Riscos Proporcionais , Fatores de Risco , Índice de Gravidade de Doença , Estatística como Assunto , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Disfunção Ventricular/diagnóstico , Disfunção Ventricular/fisiopatologia
13.
BMC Cardiovasc Disord ; 17(1): 68, 2017 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-28241861

RESUMO

BACKGROUND: Observational studies suggest there are gender based differences in the treatment of coronary artery disease, with women receiving evidence based therapy less frequently than suggested by current guidelines. The aim of our study was to evaluate gender based differences in the use of DES. METHODS: We analysed prospectively collected data from 100704 stent implantations in the PCI registry of the ALKK between 2005 and 2009. RESULTS: The usage of DES increased from 16.0 to 43.9%. Although women had smaller vessel sizes, they received DES less often compared to men (28.2 vs. 31.3%), with an adjusted odds ratio of 0.93 (95% confidence interval 0.89-0.97) at the age of 75, and an adjusted odds ratio of 0.89 (95% confidence interval 0.84-0.94) at the age of 80. CONCLUSION: Despite having smaller vessels than men, women were treated less often with DES. These findings apply to women above the age of 75 years. These findings support previous reports, that elderly women with coronary artery disease are treated differently to men.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Disparidades em Assistência à Saúde , Intervenção Coronária Percutânea/instrumentação , Avaliação de Processos em Cuidados de Saúde , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Alemanha , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
14.
J Heart Valve Dis ; 26(2): 175-184, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28820547

RESUMO

BACKGROUND: Clinically silent brain injury detected with cerebral magnetic resonance imaging (MRI) is well known after various cardiovascular interventions. Thus far, only one study has examined the periprocedural risk of cerebral ischemic events in patients undergoing percutaneous mitral valve reconstruction. The study aim was to examine the incidence and clinical impact of cerebral embolic events in patients undergoing percutaneous mitral valve reconstruction using the MitraClip® system. METHODS: Thirteen eligible high-risk patients without contraindications for MRI underwent MitraClip treatment at the authors' institution. Neurological testing with the assessment of global cognitive function was performed three days before and two days after the procedure. All patients underwent cerebral diffusion-weighted MRI (DWI) two days after the procedure. RESULTS: In nine patients, post-interventional MRI revealed newly acquired microembolic cerebral lesions. At follow up MRI scans recorded at 307 ± 270 days after the procedure, ischemic scars were not detectable in any patient. Two patients with five or more new cerebral lesions in DW-MRI showed a significant decline in their test scores. CONCLUSIONS: The MitraClip procedure results in acute cerebral lesions in the vast majority of patients. All lesions seen on DWI post-procedure resolved completely, but the number of lesions may have had an impact on cognitive function.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Embolia Intracraniana/epidemiologia , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cognição , Imagem de Difusão por Ressonância Magnética , Desenho de Equipamento , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/psicologia , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
15.
J Interv Cardiol ; 29(5): 461-468, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27477024

RESUMO

BACKGROUND: The paclitaxel drug coated balloon (DCB) is an established treatment for bare metal stent (BMS) in-stent restenosis (ISR) in native coronary arteries. The evidence of DCB-application for drug eluting stent (DES) ISR both in native coronaries and saphenous vein grafts (SVG) is limited. Aim of our study was to compare the differential efficacy of DCB for treatment of BMS- and DES-ISR in native coronary vessels and SVGs. METHODS AND RESULTS: N = 135 DCB-treated patients with available follow up (FU) angiography were included in this retrospective study. Patients received treatment between April 2009 and March 2013 at 2 tertiary care hospitals in Germany. DCB was applied in BMS-ISR (n = 65; 48%) and DES-ISR (n = 70; 52%). DCB-treated lesions were located in native coronary arteries (n = 110; 81%; BMS-ISR: n = 58; 53%; DES-ISR: n = 52; 47%) and SVGs (n = 25; 19%; BMS-ISR: n = 7, 28%; DES-ISR: n = 18, 72%). Median FU was 12 months. Endpoints were binary restenosis and target lesion revascularization (TLR). Binary restenosis (29% vs. 57%; P < 0.01) and TLR (18% vs. 46%; P < 0.01) were significantly more frequent in DES-ISR versus BMS-ISR. In SVGs, TLR was required in 72% (DES-ISR) versus 14% (BMS-ISR); P = 0.02. In the Kaplan-Meier-analysis freedom from both endpoints was significantly decreased in the DES-lesions both in the total population (binary restenosis P < 0.01; TLR P < 0.01) and native coronaries (binary restenosis P = 0.02; TLR P = 0.04). CONCLUSIONS: DCB treatment is less effective in DES-ISR than in BMS-ISR. The diminished efficacy of DCB treatment is even more pronounced in DES-ISR located within degenerated SVGs.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Antineoplásicos Fitogênicos/uso terapêutico , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Reestenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Paclitaxel/uso terapêutico , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Veia Safena/patologia , Veia Safena/transplante , Fatores de Tempo
16.
BMC Cardiovasc Disord ; 16(1): 223, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27846807

RESUMO

BACKGROUND: Transcatheter aortic valve implantation via the transfemoral route (TF-TAVI) is commonly performed as a treatment for severe aortic stenosis (AS) in patients at high surgical risk. Pre-deployment balloon aortic valvuloplasty (BAV) has generally been considered an essential step for preparing the valve landing zone for receipt of the prosthesis. However, there is little evidence supporting the clinical value of BAV, while several associated complications have been documented. This has provoked several groups to evaluate the feasibility and safety of omitting BAV form the TF-TAVI procedure (direct TF-TAVI), with encouraging results. However, studies comparing the clinical outcomes of direct TF-TAVI to standard TF-TAVI are lacking. METHODS: EASE-IT TF is a prospective, observational, two-armed, multicentre registry designed to gather data on procedural aspects, adverse events and survival rates associated with direct TF-TAVI using the Edwards SAPIEN 3 balloon-expandable prosthesis. DISCUSSION: EASE-IT-TF data will be analysed firstly to determine the risks and benefits associated with direct TF-TAVI vs. standard TF-TAVI, and secondly to identify associations between patient variables and specific outcomes. This may assist identification of patients who stand to benefit from direct TF-TAVI, therefore contributing to clinical reductions in TF-TAVI-associated morbidity and mortality rates in high-risk AS patients. TRIAL REGISTRATIONS: Clinictrials.gov: NCT02760771.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Sistema de Registros , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Estenose da Valva Aórtica/diagnóstico , Desenho de Equipamento , Feminino , Artéria Femoral , Fluoroscopia , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
17.
J Heart Valve Dis ; 25(4): 475-482, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-28009952

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) is common in patients with advanced heart failure and impaired left ventricular function. The study aim was to examine functional and hemodynamic effects at three months after MitraClip® implantation in high-risk surgical patients with FMR. METHODS: A group of 93 patients was rejected for surgical treatment by heart-team decisions due to an inacceptable risk for conventional mitral valve surgery. Between October 2011 and May 2015, 89 of these patients (96%) were treated successfully with MitraClip implantation. A subsequent complete follow up was performed over three months in 32 patients with FMR, including pro-brain natriuretic peptide (pro-BNP) measurements, six-minute walk test, echocardiography, and right heart catheterization. RESULTS: The patients (mean age 73 ± 7 years) presented with a mean left ventricular ejection fraction (LVEF) of 32 ± 13%, and mitral regurgitation (MR) grade ≥3 in 30 of 32 cases (93%). All patients suffered from severe FMR and were highly symptomatic (NYHA functional class III or IV). The mean logistic EuroSCORE was 33%. MitraClip implantation resulted in a significant clinical improvement and reverse cardiac remodelling with a decrease in LV end-diastolic and LV endsystolic diameters, while LVEF was unchanged. In addition, a statistically relevant reduction of systolic, diastolic and mean pulmonary artery pressures (PAPsystolic -7.2 mmHg, p = 0.011; PAPdiastolic -4.5 mmHg, p = 0.003; and PAPmean -5.3 mmHg, p = 0.007) were measured, while the cardiac index (+0.3 l/min/m2, p <0.001) and cardiac output (+0.5 l/min, p <0.001) were increased significantly. The 30-day mortality was 8.6% (n = 8). CONCLUSIONS: Among the study population, MitraClip implantation led to clinical improvement, reverse cardiac remodeling, and a sustained hemodynamic benefit during the three-month follow up period.


Assuntos
Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Instrumentos Cirúrgicos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
18.
J Cardiovasc Electrophysiol ; 25(4): 339-345, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24237612

RESUMO

INTRODUCTION: "Single shot" ablation devices to treat symptomatic atrial fibrillation have been engineered over the last years. Safety and efficacy also includes subclinical complications only detected with esophageal endoscopy or cerebral MRI in asymptomatic patients. We studied the acute efficacy and safety profile of a novel multipolar irrigated RF ablation catheter (nMARQ™). METHODS AND RESULTS: Forty-three patients underwent pulmonary vein isolation (PVI) using the novel ablation device. Patient baseline and procedural characteristics were documented. Efficacy of PVI was identified using only the nMARQ™ catheter. All patients underwent postablation endoscopic evaluation of the esophagus to document thermal damage and cerebral MRI (diffusion weight imaging, attenuated diffusion coefficient-map) to document incidence and number of silent cerebral lesions (SCL). Effective PVI was achieved in 98% of targeted PVs in a mean procedure time of 133 minutes. A mean of 4.8, 60-second RF applications, per PV was needed for effective PVI. No clinical procedure-associated complications were noted. Esophageal temperature increase >40.5 °C was noted in 22 (51%) patients and 14 of these had thermal esophageal lesions on endoscopic evaluation. A total of 26 SCLs were noted in 14 patients (33%; 1.9/patient; mean diameter of 2.3 mm, 88% of lesions were ≤3 mm). CONCLUSIONS: PVI using the novel irrigated RF multipolar ablation device (nMARQ™) appears to be acutely effective. No clinical complications were identified. A high incidence of SCL (33%) and thermal esophageal lesions (33%) bears caution and further studies on long-term efficacy and safety are needed.


Assuntos
Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Lesões Encefálicas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Recidiva , Segurança , Resultado do Tratamento
19.
Indian Pacing Electrophysiol J ; 14(5): 240-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25408564

RESUMO

BACKGROUND: Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear. OBJECTIVE: Comparing the risk for SCE depending on exchanges of catheters (ExCath) over a single transseptal sheath. METHODS: 88 Patients undergoing pulmonary vein isolation (PVI) only ablation using either single-tip or balloon-based technique underwent pre- and post-ablation cerebral MRI. Ablations were either performed with double transseptal access and without exchanging catheters over the transseptal sheaths (group 1: no ExCath) or after a single transseptal access and exchanges of therapeutic and diagnostic catheters (group 2: ExCath). Differences in regard to SCE rates were analyzed. Multivariate analysis was performed to identify factors related to the risk for SCE. RESULTS: Included patients underwent PVI using single tip irrigated radiofrequency in 41, endoscopic laser balloon in 27 and cryoballoon in 20 cases. Overall SCE were identified in 23 (26%) patients. In group 1 (no ExCath; N=46) 6 patients (13%) and in group 2 (N=42) 17 patients (40%) had documented SCE (p=0.007). The applied ablation technology did not affect SCE rate. In multivariate analysis age (OR 1.1, p=0.03) and catheter exchanges over a single transseptal sheath (OR 12.1, p=0.007) were the only independent predictors of a higher risk for SCE. CONCLUSIONS: Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.

20.
Artigo em Inglês | MEDLINE | ID: mdl-39161173

RESUMO

AIM: To assess the level of self-efficacy in patients with heart failure (HF), and identify differences between important subgroups including sex, and to identify the determinants of high self-efficacy. METHODS AND RESULTS: This was a pooled cross-sectional analysis of 2,030 patients from four prospective studies conducted within the German Competence Network Heart Failure. We used the Self-efficacy Subscale and the Overall Summary Score (OSS) of the Kansas City Cardiomyopathy Questionnaire (KCCQ-23) to assess self-efficacy and health-related quality of life. The cut-off of 75 score points was used for the dichotomization into high (≥75) vs low (<75) self-efficacy. Depressive symptoms were measured by the Patient Health Questionnaire (PHQ-9). A total of 1,615 patients with HF provided complete self-efficacy scores: mean age 66.6±12.3 years, 431 (27%) women. Mean self-efficacy was 67.5±24.9, with 907 patients (56.2%) showing high self-efficacy and 708 patients (43.8%) showing low self-efficacy. Men had higher self-efficacy scores than women (68.7±24.5 vs. 64.2±26.0; p=0.001). Multivariable logistic regression identified KCCQ-OSS (OR per 5-point increase 1.08, 95%CI 1.04-1.12), female sex (OR 0.72, 95%CI 0.56-0.94), depressive symptoms (OR per 3-point increase in PHQ-9 0.90, 95%CI 0.83-0.98), and acute HF (0.46, 95% CI 0.34-0.62) as important predictors of high self-efficacy. CONCLUSION: In patients with HF, women seemed to exhibit lower self-efficacy than men. Health-related quality of life and psychological well-being were dominant determinants of self-efficacy. Future studies should investigate the role of self-efficacy as a therapeutic target for tailored and sex-specific nursing interventions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA