1.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671359

RESUMO

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Punções/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 32(4): 925-930, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33590568

RESUMO

INTRODUCTION: Cryoballoon ablation is an established technique to achieve pulmonary vein isolation in patients with atrial fibrillation (AF). Recently, a new manufacturer of cryoballoon achieved regulatory CE marking (POLARx™; Boston Scientific). We describe our early experience of using this new market entrant of the technology and describe procedural aspects in comparison to the incumbent Medtronic Arctic Front Advance™. METHODS: We assessed the first 40 AF ablations performed with the POLARx catheter at the Barts Heart Centre. These patients were compared with a contemporaneous series of patients undergoing ablation by the same operators using the Arctic Front Advance. Procedural metrics were prospectively recorded. RESULTS: A total of four operators undertook 40 cases using the POLARx catheter, compared with 40 cases using the Arctic Front Advance. Procedure times (60.0 vs. 60.0 min) were similar between the two technologies, however left atrial dwell time (35.0 vs 39.0 min) and fluoroscopy times (3.3 vs. 5.2 min) were higher with the POLARx. Measured nadir and isolation balloon temperatures were significantly lower with POLARx. Almost all veins were isolated with a median freezing time of 16.0 (POLARx) versus 15.0 (Arctic Front Advance) min. The rate of procedural complications was low in both groups. CONCLUSION: The POLARx cryoballoon is effective for pulmonary vein isolation. Measured isolation and nadir temperatures are lower compared with the predicate Arctic Front Advance catheter. The technology appears similar in acute efficacy and has a short learning curve, but formal dosing studies may be required to prove equivalence of efficacy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Fluoroscopia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tecnologia , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33782987

RESUMO

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino
4.
Pacing Clin Electrophysiol ; 41(11): 1454-1460, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30221382

RESUMO

BACKGROUND: Many patients undergoing ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation receive antithrombotic medications.  Their uninterrupted use has the potential to affect complication rates. We assessed the incidence of complications in a large cohort of patients undergoing these procedures, according to antithrombotic medication use. METHODS: From June 2014 to June 2016, 201 VT and PVC ablations were performed at a single center. We allocated patients to three groups: (A) anticoagulation group (international normalized ratio ≥ 1.5 or non-vitamin K anticoagulant or full-dose low-molecular-weight (LMW) heparin on day of procedure); (B) antithrombotic group (antiplatelet therapy and/or prophylactic LMW heparin on day of procedure); and (C) no antithrombotics group.  We assessed periprocedural complication rates in each group.  Multivariable analysis was performed. RESULTS: Group A (47 patients) had 8.5% procedural complication rate: one stroke, one pseudoaneurysm, one femoral artery occlusion, and one access site hematoma. In this group, 37 patients had femoral arterial and 18 had epicardial access. In Group B (46 patients), the complication rate was 6.5%: two cardiac tamponades and one pericardial effusion without compromise. Group C (108 patients) had a 5.6% complication rate: three cardiac tamponades (with one periprocedural death and one concomitant gastric vessel injury), one pericardial effusion without compromise, one stomach perforation, and two access site hematomas. Multivariable analysis did not show any significant predictors of complications, though age approached significance. CONCLUSIONS: Complication rates were not significantly different between groups. These findings suggest that VT and PVC ablation can be performed safely in patients with uninterrupted antithrombotic medications.


Assuntos
Anticoagulantes/administração & dosagem , Ablação por Cateter/métodos , Complicações Pós-Operatórias/epidemiologia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/tratamento farmacológico , Complexos Ventriculares Prematuros/cirurgia , Idoso , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco
5.
Cardiol Young ; 27(2): 284-293, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27225323

RESUMO

BACKGROUND: Adults with tetralogy of Fallot experience atrial tachyarrhythmias; however, there are a few data on the outcomes of radiofrequency ablation. We examined the characteristics, outcome, and predictors of recurrence of atrial tachyarrhythmias after radiofrequency ablation in tetralogy of Fallot patients. Methods/results Retrospective data were collected from 2004 to 2013. In total, 56 ablations were performed on 37 patients. We identified two matched controls per case: patients with tetralogy of Fallot but no radiofrequency ablation and not known to have atrial tachyarrhythmias. Acute success was 98%. Left atrial arrhythmias increased in frequency over time. The mean follow-up was 41 months; 78% were arrhythmia-free. Number of cardiac surgeries, age, and presence of atrial fibrillation were predictors of recurrence. Lone cavo-tricuspid isthmus-dependent flutter reduced the likelihood of atrial fibrillation. Right and left atria in patients with tetralogy of Fallot were larger in ablated cases than controls. NYHA class was worse in cases and improved after ablation; baseline status predicted death. Of matched non-ablated controls, a number of them had atrial fibrillation. These patients were excluded from the case-control study but analysed separately. Most of them had died during follow-up, whereas of the matched ablated cases all were alive and the majority in sinus rhythm. CONCLUSION: Patients with tetralogy of Fallot and atrial tachyarrhythmias have more dilated atria than those without atrial tachyarrhythmias. Radiofrequency ablation improves functional status. Left atrial ablation is more commonly required with repeat procedures. There is a high prevalence of atrial tachyarrhythmias, particularly atrial fibrillation, in patients with tetralogy of Fallot; early radiofrequency ablation may have a protective effect against this.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Tetralogia de Fallot/complicações , Adulto , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
6.
Am J Physiol Heart Circ Physiol ; 311(3): H545-54, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27371682

RESUMO

The spatial variation in restitution properties in relation to varying stimulus site is poorly defined. This study aimed to investigate the effect of varying stimulus site on apicobasal and transmural activation time (AT), action potential duration (APD) and repolarization time (RT) during restitution studies in the intact human heart. Ten patients with structurally normal hearts, undergoing clinical electrophysiology studies, were enrolled. Decapolar catheters were placed apex to base in the endocardial right ventricle (RVendo) and left ventricle (LVendo), and an LV branch of the coronary sinus (LVepi) for transmural recording. S1-S2 restitution protocols were performed pacing RVendo apex, LVendo base, and LVepi base. Overall, 725 restitution curves were analyzed, 74% of slopes had a maximum slope of activation recovery interval (ARI) restitution (Smax) > 1 (P < 0.001); mean Smax = 1.76. APD was shorter in the LVepi compared with LVendo, regardless of pacing site (30-ms difference during RVendo pacing, 25-ms during LVendo, and 48-ms during LVepi; 50th quantile, P < 0.01). Basal LVepi pacing resulted in a significant transmural gradient of RT (77 ms, 50th quantile: P < 0.01), due to loss of negative transmural AT-APD coupling (mean slope 0.63 ± 0.3). No significant transmural gradient in RT was demonstrated during endocardial RV or LV pacing, with preserved negative transmural AT-APD coupling (mean slope -1.36 ± 1.9 and -0.71 ± 0.4, respectively). Steep ARI restitution slopes predominate in the normal ventricle and dynamic ARI; RT gradients exist that are modulated by the site of activation. Epicardial stimulation to initiate ventricular activation promotes significant transmural gradients of repolarization that could be proarrhythmic.


Assuntos
Potenciais de Ação/fisiologia , Endocárdio/fisiologia , Sistema de Condução Cardíaco/fisiologia , Ventrículos do Coração , Coração/fisiologia , Função Ventricular , Adulto , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio
7.
J Cardiovasc Electrophysiol ; 27(11): 1328-1336, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27566538

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is a risk factor for arrhythmias in patients with heart failure (HF). However, the effects of CKD on ventricular arrhythmia (VA) burden in patients with cardiac resynchronization therapy and defibrillator (CRT-D) devices in a primary prevention setting are unknown. OBJECTIVE: To determine whether baseline CKD is associated with increased risk of VA in patients implanted with primary prevention CRT-D devices. METHODS AND RESULTS: In this retrospective study, 199 consecutive primary prevention CRT-D recipients (2005-2010) were stratified by estimated glomerular filtration rate (eGFR) levels prior to device implantation with 106 (53.2%) ≥CKD III (eGFR < 60 mL/min/1.73 m2 ) (CKD group). CKD group patients were significantly older (70.0 ± 10 years vs. 61.3 ± 12 years, P < 0.05) with higher prevalence of ischemic cardiomyopathy (56.2% vs. 40.2%, P < 0.05). Detected ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes resulting in device therapy occurred significantly more frequently in the CKD group [40/106(37.8%)] than controls [24/93(25.8%)], (odd ratio [OR] = 1.74, 95% confidence interval [CI] = 1.01-3.2, P = 0.05). At 5-year follow-up, interval censored data analysis showed 41% VT/VF incidence in the CKD group compared to 24% incidence in controls (P < 0.05). Cox proportional hazards model identified CKD > III as the only predictor of sustained VA in this group (adjusted hazard ratio [HR] 2.92, CI = 1.39-6.1, P = 0.004). CONCLUSION: Baseline CKD is a strong independent risk factor for VA in primary prevention CRT-D recipients. Further understanding of the underlying arrhythmogenic mechanisms relating to CKD may be of interest to allow appropriate correction and prevention. Device programming in this cohort may need to reflect this increased risk.

8.
Europace ; 18(8): 1187-93, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26566940

RESUMO

AIMS: The Goldenberg risk score, comprising five clinical risk factors (New York Heart Association class >2, atrial fibrillation, QRS duration >120 ms, age >70 years, and urea >26 mg/dL), may help identify patients in whom the survival benefit of the defibrillator may be limited. We aim at assessing whether this score can accurately predict the long-term all-cause mortality risk of patients receiving cardiac resynchronization therapy (CRT) and identify those who are more likely to benefit from the defibrillator. METHODS AND RESULTS: In this retrospective observational cohort study, 638 patients with ischaemic or non-ischaemic dilated cardiomyopathy who had CRT-defibrillator (CRT-D) (n = 224) vs. CRT-pacemaker (CRT-P) (n = 414) implantation were prospectively followed up for survival outcomes. The long-term outcome of patients with CRT-D vs. CRT-P was compared within risk score categories and in patients with severe renal dysfunction. Mean follow-up in surviving and deceased patients was 62.7 and 32.5 months, respectively. This score showed higher discriminative performance in all-cause mortality prediction in CRT-D vs. CRT-P patients (area under the curve 0.718 ± 0.041 vs. 0.650 ± 0.032, respectively, P = 0.001). In those with scores 0-2, a CRT-D device decreased mortality rates in the first 4 years of follow-up compared with CRT-P (11.3 vs. 24.7%, P = 0.041), but this effect attenuated with longer follow-up duration (21.2 vs. 32.7%, P = 0.078). In this group, the benefit of CRT-D during the follow-up was seen after adjusting for traditional mortality predictors (hazard ratio 0.339, P = 0.001). No significant differences in mortality rates were seen in patients with score ≥3 (57.9% with CRT-D vs. 56.9%, P = 0.8) and those with severe renal dysfunction (92.9% in CRT-D vs. 76.2%, P = 0.17). Similar results were seen following propensity score matching. CONCLUSION: A simple risk stratification score comprising five clinical risk factors may help identify CRT patients who are more likely to benefit from the presence of the defibrillator.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Função Ventricular Esquerda
9.
Eur Heart J ; 36(18): 1098-105, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25549725

RESUMO

AIMS: AL amyloidosis may respond to chemotherapy but two-thirds of patients with severe cardiac involvement die within a year of diagnosis, purportedly from tachyarrhythmias or electromechanical dissociation. We sought to characterize the nature of cardiac arrhythmias in severe cardiac AL amyloidosis using implanted cardiac rhythm recorders. METHODS AND RESULTS: Implantable loop recorders (ILRs) were inserted within 24 h of baseline evaluation at the UK National Amyloidosis Centre, into 20 consecutive patients with newly diagnosed severe cardiac AL amyloidosis and symptoms of syncope or pre-syncope. Weekly ILR recordings and additional recordings at the time of symptoms were obtained. Median (range) follow-up from baseline was 308 (10-399) days. Thirteen patients died, and median survival in the whole cohort was 61 days from device insertion. In each of eight evaluable cases, death was heralded by bradycardia, usually associated with complete atrioventricular block (CAVB), followed shortly thereafter by pulseless electrical activity. Four patients received pacemakers, a median (range) of 7 (3-38) h after development of symptomatic CAVB, but these did not prevent rapid cardiac decompensation and death in three cases. Despite 272 loop recordings, there was only one episode of non-sustained ventricular tachycardia, which was preceded by severe bradycardia. Patients who died had significantly worse global left ventricular strain on echocardiography (P = 0.029) and reduced 6 min walk distance (P = 0.048) at baseline compared with survivors. CONCLUSIONS: The discovery that bradyarrhythmias heralded terminal cardiac decompensation in most patients with severe cardiac AL amyloidosis supports a study of prophylactic pacemaker insertion in this patient population.


Assuntos
Amiloidose/complicações , Arritmias Cardíacas/diagnóstico , Cardiomiopatias/complicações , Adulto , Idoso , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Arritmias Cardíacas/etiologia , Coleta de Dados , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos Implantados , Feminino , Parada Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
11.
Echocardiography ; 31(6): 736-43, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24303794

RESUMO

BACKGROUND: Assessment of transmural scar at the site of latest mechanical activation is relevant to maximize outcomes in cardiac resynchronization therapy (CRT). Few studies have assessed the ability of speckle tracking echocardiography (STE)-derived short-axis strain to identify segmental myocardial scar, defined by contrast-enhanced cardiac magnetic resonance imaging (CMR), in patients referred for CRT. METHODS: A total of 26 patients with ischemic cardiomyopathy who underwent preprocedure echocardiography and CMR were studied. Extent of transmural scar was assessed using contrast-enhanced CMR and corresponding peak segmental radial and circumferential strains were derived using two-dimensional (2D) STE. Total left ventricle (LV) scar volume was compared with parameters of global strain. CRT response was defined as >15% reduction in LV end systolic volume (LVESV) at 6 months. RESULTS: Speckle tracking short-axis strain analysis was technically possible in over 90% of LV segments. Applying a segmental radial strain cutoff value of 10% distinguished segments with >50% scar area with a high negative predictive value (98%). Global longitudinal strain <-5% predicted CRT response. CONCLUSIONS: Two-dimensional STE offers potential to characterize dysfunctional myocardium and define segmental scar offering an integrated imaging approach to guide LV lead placement for CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Cicatriz/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Isquemia Miocárdica/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Cardiomiopatias/complicações , Cicatriz/complicações , Cicatriz/terapia , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/terapia , Encaminhamento e Consulta , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/prevenção & controle
13.
Europace ; 13(6): 845-52, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21427090

RESUMO

AIMS: Left ventricular (LV) lead placement to the most delayed segment offers the greatest potential benefit to cardiac resynchronization therapy (CRT). We assessed the impact of interventricular (VV) optimization on acute changes in cardiac output (CO) in patients with and without LV pacing of the most delayed segment. METHODS AND RESULTS: In 124 patients, the most delayed segment was defined by speckle tracking radial strain and the LV lead position by biplane fluoroscopy. Patients were classified as either a concordant (LV lead at latest site), adjacent (within one segment), or remote (two or more segments away) LV lead. Atrioventricular (AV) and VV delays were optimized by echocardiography. Cardiac output was measured non-invasively and a >20% increase in CO from baseline (intrinsic) defined acute response. Changes in CO in patients with concordant, adjacent, or remote LV leads were recorded following atrioventricular optimization alone (AV OPT) and after combined AV and VV optimization (AV/VV OPT). Compared with AV OPT pacing, AV/VV OPT produced a greater rise in CO (5.45 ± 1.1 vs. 5.76 ± 1.2 L/min, P< 0.001) and higher acute response rates (48.4 vs. 61.3%, P= 0.041). In adjacent patients, compared with AV OPT pacing, AV/VV OPT settings increased the response rate from 36.4 to 63.6% (P= 0.037). VV optimization had no effect on acute response rates in patients with remote (26.7 vs. 33.3%, P = 0.581) or concordant LV leads (65.6 vs. 72.1%, P = 0.438). CONCLUSION: VV optimization overcomes some but not all of the deleterious effects of a suboptimal LV lead position.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Disfunção Ventricular Esquerda/terapia , Idoso , Idoso de 80 Anos ou mais , Débito Cardíaco/fisiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Eletrodos , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 34(11): 1527-36, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21797899

RESUMO

AIMS: Noninvasive cardiac output (CO) measurement (NICOM) is a novel method to assess ventricular function and offers a potential alternative for optimization of cardiac resynchronization therapy (CRT) devices. We compared the effect of NICOM-based optimization to no optimization (empiric settings) on CRT outcomes. METHODS: Two hundred and three patients undergoing CRT were assessed in two consecutive nonrandomized groups; an empiric group (n = 54) was programmed to "out of the box" settings with a fixed AV delay of 120 ms and a VV delay of 0 ms; and the optimization group (n = 149) underwent adjustments of both the AV and VV delays according to the greatest improvement in resting CO. The primary endpoints were improvements in left ventricular (LV) volumes and function from baseline at 6 months. Secondary endpoints were change in New York Heart Association (NYHA) class, quality of life score, and 6-minute walk test (6 MWT) performance. RESULTS: After 6 months of CRT, the optimization group had a better clinical response with lower NYHA class (2.1 ± 0.8 vs 2.4 ± 0.8, P = 0.048) and quality of life scores (35 ± 18 vs 42 ± 20, P = 0.045) but no differences in 6-MWT performance (269 ± 110 vs 277 ± 114 m, P = 0.81). Echocardiographic response was also better in the optimization group with lower LV end systolic volume (108 ± 51 vs 126 ± 60 mL, P = 0.048) and higher ejection fraction (30 ± 7 vs 27 ± 8, P = 0.01) compared to empiric settings. CONCLUSION: Device optimization using noninvasive measures of CO is associated with better clinical and echocardiographic response compared to empiric settings.


Assuntos
Débito Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Cardiografia de Impedância/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações
15.
Pacing Clin Electrophysiol ; 34(4): 467-74, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21208234

RESUMO

INTRODUCTION: Left ventricular (LV) lead placement to the latest contracting area (concordant LV lead) is associated with better response to cardiac resynchronization therapy (CRT) compared to a discordant LV lead. However, the effect of the right ventricular (RV) lead site on CRT response is unclear. We investigated the relationship of the RV and LV lead positions on CRT response. METHODS: In 131 CRT patients, the LV lead was positioned preferentially in a lateral or posterolateral vein and the RV lead to either the RV septum (RVS, n = 55) or RV apex (RVA, n = 76). The latest site of contraction was determined with two-dimensional speckle tracking radial strain imaging and patients had a concordant LV lead position if pacing the latest segment, and discordant if not. Response was defined as ≥15% reduction in LV end systolic volume (LVESV) at 6-month follow-up. RESULTS: There were no significant differences in mean reduction of LVESV at follow-up (RVS vs RVA: -23.3 ± 16% vs 22.1 ± 18%, P = 0.70) or rate of responders (58.2% vs 57.9%, P = 0.97) between the two groups. In patients with a concordant LV lead (n = 71), the response rate was significantly higher than those with a discordant lead (76.1% vs 36.7%, P < 0.001). There were no differences in outcomes in patients with a concordant or discordant LV lead according to the RV lead location. CONCLUSION: The extent of LV reverse remodeling following CRT is not related to the RV lead position, but is significantly higher in patients with a concordant LV lead.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Eletrodos Implantados , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Implantação de Prótese/estatística & dados numéricos , Idoso , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Feminino , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração , Humanos , Masculino , Prevalência , Implantação de Prótese/métodos , Resultado do Tratamento , Reino Unido/epidemiologia
16.
PLoS One ; 16(2): e0248083, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33635899

RESUMO

[This corrects the article DOI: 10.1371/journal.pone.0244059.].

17.
PLoS One ; 15(12): e0244059, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33373381

RESUMO

Numerous cropping systems of the world are experiencing the emergence of new weed species in response to conservation agriculture. Conyza stricta Willd. is being a newly emerging weed of barley-based cropping systems in response to conservational tillage practices. Seed germination ecology of four populations (irrigated, rainfed, abandoned and ruderal habitats) was studied in laboratory and greenhouse experiments. The presence/absence of seed dormancy was inferred first, which indicated seeds were non-dormant. Seed germination was then recorded under various photoperiods, constant and alternating day/night temperatures, and pH, salinity and osmotic potential levels. Seedling emergence was observed from various seed burial depths. Seeds of all populations proved photoblastic and required 12-hour light/dark period for germination. Seeds of all populations germinated under 5-30°C constant temperature; however, peak germination was recorded under 17.22-18.11°C. Nonetheless, the highest germination was noted under 20/15°C alternating day/night temperature. Ruderal and irrigated populations better tolerated salinity and germinated under 0-500 mM salinity. Similarly, rainfed population proved more tolerant to osmotic potential than other populations. Seeds of all populations required neutral pH for the highest germination, whereas decline was noted in germination under basic and alkaline pH. Seedling emergence was retarded for seeds buried >2 cm depth and no emergence was recorded from >4 cm depth. These results add valuable information towards our understanding of seed germination ecology of C. stricta. Seed germination ability of different populations under diverse environmental conditions suspects that the species can present severe challenges in future if not managed. Deep seed burial along with effective management of the emerging seedlings seems a pragmatic option to manage the species in cultivated fields. However, immediate management strategies are needed for rest of the habitats.


Assuntos
Conyza/crescimento & desenvolvimento , Germinação , Irrigação Agrícola , Biomassa , Salinidade , Solo/química , Temperatura , Controle de Plantas Daninhas/métodos
18.
Thromb Res ; 188: 90-96, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32113073

RESUMO

INTRODUCTION: Use of non-vitamin K oral anticoagulants (NOACs) has rapidly increased worldwide. We aimed to systematically assess the available evidence regarding the safety and efficacy of NOACs in patients undergoing cardiac implantable electronic device (CIED) surgery. METHODS: We performed a systematic literature search. Eligible randomised controlled trials and cohort studies were included. The primary outcome measures were clinically significant device-pocket haematoma and thromboembolic events. RESULTS: A total of 12 studies were included, equating to 2120 patients. The separate pooling of rate of events showed a low incidence of clinically significant device-pocket haematoma, although numerically higher in patients on continued (1.5%; CI95%0.8-3.0) versus interrupted NOAC (0.9%; CI95%0.5-1.7). The rate of any device-pocket haematoma was numerically higher in the continued versus interrupted NOAC group (5.4%; CI95%3.8-7.7 versus 2.4%; CI95%1.8-3.3). The incidence of thromboembolic events (0.4%; CI95%0.2-0.8) was low and comparable. From a meta-analysis of 3 studies (equating to 773 subjects) allowing for a comparison of continued versus interrupted NOAC, we found no significant difference between the 2 strategies in terms of clinically significant pocket haematoma (RR1.14; CI95%0.43-3.06, p = 0.79), thromboembolic complications (RR1.03; CI95%0.06-16.37, p = 0.98), and any pocket haematoma (RR1.19; CI95%0.65-2.20, p = 0.57). CONCLUSION: Use of NOACs at the time of CIEDs surgery appears to be safe, and either strategy of peri-procedure continuation or interruption might be reasonable. However, continuation of NOAC seems to be associated with a numerically higher rate of bleeding complications. Certainty of the evidence is low, and further studies are required to confirm these findings.


Assuntos
Fibrilação Atrial , Tromboembolia , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Hematoma/etiologia , Humanos , Tromboembolia/tratamento farmacológico , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Vitamina K
19.
Europace ; 11(5): 554-61, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19372115

RESUMO

Cardiac resynchronization therapy (CRT) offers proven benefit to patients with refractory symptomatic chronic heart failure (New York Heart Association Class III or IV), severe left ventricular (LV) systolic dysfunction (LV ejection fraction <35%), and LV dyssynchrony (QRS width >120 ms). Cardiac resynchronization therapy has the potential to improve survival and functional capacity, reduce hospital admissions, and promote LV reverse remodelling. Although difficult to truly evaluate, up to 30% of patients do not attain symptomatic benefit. Factors associated with a poor outcome include inappropriate patient selection, inadequate device programming, presence of myocardial scar, and suboptimal LV lead placement. Left ventricular dyssynchrony is an important determinant of CRT response, although at present no reliable single measure to identify patients beyond QRS width has been identified. In this review, we discuss the effect of LV lead placement to pace the region of maximal dyssynchrony, the impact of total scar burden on response, and the relationship between LV lead position and localized scar. Consideration is also given to prospectively defining placement of the LV lead including surgical epicardial lead positioning.


Assuntos
Desfibriladores Implantáveis , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Cicatriz/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
20.
Europace ; 11(11): 1491-5, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19880411

RESUMO

AIMS: Recent studies suggest differences in coronary venous anatomy between patients with ischaemic (I) and non-ischaemic (N) cardiomyopathy. We hypothesize that these differences may affect the potential for left ventricular (LV) lead targeting in patients undergoing cardiac resynchronization therapy. METHODS AND RESULTS: The retrograde contrast venograms were retrospectively reviewed in 133 patients (age 68 +/- 9 years, 101 males). The quantity and distribution of veins were recorded as well as the final lead position. There were no major differences in the distribution of LV lead positions between I and N [posterior vein, 14.0% (I) vs. 15.8% (N); posterolateral vein, 21.1 vs. 18.4%; lateral vein, 59.7 vs. 50.0%; anterolateral vein, 3.5 vs. 13.2%; P= NS]. Excluding the middle and great cardiac veins, in total only 59 of 133 patients had more than one suitable vein as potential targets for LV lead placement (I, 36.8% vs. N, 50.0%; P = 0.16). CONCLUSION: Underlying aetiology does not affect the quantity and distribution of coronary veins available for LV lead placement. The limitations of venous anatomy restrict LV lead placement to a single vein with little scope for site selection in almost half of all the patients. Given these limitations, in many patients, prospective targeting of LV lead placement may require a direct surgical approach.


Assuntos
Estimulação Cardíaca Artificial/métodos , Angiografia Coronária/métodos , Eletrodos Implantados , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Flebografia/métodos , Implantação de Prótese/métodos , Idoso , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA