Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 622
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Nat Prod ; 87(4): 733-742, 2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38573876

RESUMO

Nine bacteria were isolated from the episphere of Suaeda maritima (L.) Dumort. Among them, the bacterial strain YSL2 displayed the highest antimicrobial activity on agar plates and exhibited significant novelty compared with other bacteria based on 16S rRNA analysis. Consequently, Nocardiopsis maritima YSL2T was subjected to phenotypic characterization and whole-genome sequencing. Phylogenetic analysis revealed its close association with Nocardiopsis aegyptia SNG49T. Furthermore, genomic analysis of strain YSL2T revealed the presence of various gene clusters, indicating its potential for producing antimicrobial secondary metabolites. Upon cultivation on a large scale, maritiamides A and B (1 and 2) were isolated and characterized as cyclic hexapeptides based on nuclear magnetic resonance, ultraviolet, infrared, and mass spectrometric data. The absolute configurations of the amino acid residues in the maritiamides were determined through chiral derivatization, utilizing FDAA and GITC. Maritiamides 1 and 2 exhibited promising antibacterial activities against Staphylococcus epidermidis and weakly inhibited the growth of Escherichia coli and Pseudomonas fluorescens.


Assuntos
Antibacterianos , Nocardiopsis , Antibacterianos/farmacologia , Antibacterianos/química , Chenopodiaceae/microbiologia , Escherichia coli/efeitos dos fármacos , Genômica , Metabolômica , Testes de Sensibilidade Microbiana , Estrutura Molecular , Nocardiopsis/química , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacologia , Filogenia , Pseudomonas/efeitos dos fármacos , RNA Ribossômico 16S/genética , Staphylococcus/efeitos dos fármacos
2.
Artigo em Inglês | MEDLINE | ID: mdl-39174426

RESUMO

BACKGROUND AND AIMS: The estimated glucose disposal rate (eGDR) is an easily accessible clinical parameter for assessing insulin resistance in patients with diabetes mellitus. In this study, we aimed to investigate the link between eGDR and subclinical coronary atherosclerosis in an asymptomatic middle-aged Korean population. METHODS AND RESULTS: This study involved 4004 subjects who underwent routine health checkups with coronary multidetector computed tomography (MDCT) at Asan Medical Center from 2007 to 2011, among whom 913 had a follow-up analysis through 2014. The eGDR was calculated using: 21.16 - (0.09 ∗ waist circumference [cm]) - (3.41 ∗ hypertension) - (0.55 ∗ glycated hemoglobin [%]). Patients were categorized into three groups according to the tertiles of eGDR. Subclinical coronary atherosclerosis was defined by significant coronary stenosis (≥50%), presence of plaques, coronary artery calcification (CAC) score, and its progression. As a result, a lower eGDR level was associated with higher prevalence of significant coronary stenosis, plaques, moderate to severe CAC, and CAC progression. Compared to other markers or risk scores, eGDR was superior to other biomarkers of insulin resistance but did not provide additional information beyond classic cardiovascular risk models like the Framingham Risk Score and Pooled Cohort Equations. CONCLUSION: Decreased eGDR values were significantly associated with higher subclinical coronary atherosclerosis burdens in an asymptomatic middle-aged Korean population. However, its clinical implications remain uncertain due to its weaker performance compared to established cardiovascular risk models.

3.
Nucleic Acids Res ; 50(4): 2363-2376, 2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35166843

RESUMO

Bacteria and archaea use the CRISPR-Cas system to fend off invasions of bacteriophages and foreign plasmids. In response, bacteriophages encode anti-CRISPR (Acr) proteins that potently inhibit host Cas proteins to suppress CRISPR-mediated immunity. AcrIE4-F7, which was isolated from Pseudomonas citronellolis, is a fused form of AcrIE4 and AcrIF7 that inhibits both type I-E and type I-F CRISPR-Cas systems. Here, we determined the structure of AcrIE4-F7 and identified its Cas target proteins. The N-terminal AcrIE4 domain adopts a novel α-helical fold that targets the PAM interaction site of the type I-E Cas8e subunit. The C-terminal AcrIF7 domain exhibits an αß fold like native AcrIF7, which disables target DNA recognition by the PAM interaction site in the type I-F Cas8f subunit. The two Acr domains are connected by a flexible linker that allows prompt docking onto their cognate Cas8 targets. Conserved negative charges in each Acr domain are required for interaction with their Cas8 targets. Our results illustrate a common mechanism by which AcrIE4-F7 inhibits divergent CRISPR-Cas types.


Assuntos
Bacteriófagos , Proteínas Associadas a CRISPR , Bacteriófagos/genética , Proteínas Associadas a CRISPR/metabolismo , Sistemas CRISPR-Cas , DNA/metabolismo , Proteínas Virais/metabolismo
4.
Paediatr Anaesth ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980197

RESUMO

INTRODUCTION: This study aimed to assess the impact of positive-end-expiratory pressure (PEEP) on the non-hypoxic apnea time in infants during anesthesia induction with an inspired oxygen fraction of 0.8. METHODS: This age stratified randomized controlled trial included patients under 1 year of age. Preoxygenation was performed using an inspired oxygen fraction of 0.8 for 2 min. Inspired oxygen fraction of 0.8 was administered via a face mask with volume-controlled ventilation at a tidal volume of 6 mL.kg-1, with or without 7 cmH2O of PEEP. Tracheal intubation was performed after 3 min of ventilation; however, it was disconnected from the breathing circuit. Ventilation was resumed once the pulse oximetry readings reached 95%. The primary outcome was the non-hypoxic apnea time, defined as the time from the cessation of ventilation to achieving a pulse oximeter reading of 95%. The secondary outcome measures included the degree of atelectasis assessed by ultrasonography and the presence of gastric air insufflation. RESULTS: Eighty-four patients were included in the final analysis. In the positive end-expiratory pressure group, the atelectasis score decreased (17.0 vs. 31.5, p < .001; mean difference and 95% CI of 11.6, 7.5-15.6), while the non-hypoxic apnea time increased (80.1 s vs. 70.6 s, p = .005; mean difference and 95% CI of -9.4, -16.0 to -2.9), compared to the zero end-expiratory pressure group, among infants who are 6 months old or younger, not in those aged older than 6 months. DISCUSSION: The application of positive end-expiratory pressure reduced the incidence of atelectasis and extended the non-hypoxic apnea time in infants who are 6 months old or younger. However, it did not affect the incidence of atelectasis nor the non-hypoxic apnea time in patients aged older than 6 months.

5.
Paediatr Anaesth ; 34(8): 758-767, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38693633

RESUMO

AIMS: This study determined the optimal positive end-expiratory pressure levels in infants in supine and prone positions under general anesthesia using electrical impedance tomography (EIT). METHODS: This prospective observational single-centre study included infants scheduled for surgery in the prone position. An electrical impedance tomography sensor was applied after inducing general anesthesia. The optimal positive end-expiratory pressure in the supine position was determined in a decremental trial based on EIT and compliance. Subsequently, the patient's position was changed to prone. Electrical impedance tomography parameters, including global inhomogeneity index, regional ventilation delay, opening pressure, the centre of ventilation, and pendelluft volume, were continuously obtained up to 1 h after prone positioning. The optimal positive end-expiratory pressure in the prone position was similarly determined. RESULTS: Data from 30 infants were analyzed. The mean value of electrical impedance tomography-based optimal positive end-expiratory pressure in the prone position was significantly higher than that in the supine position [10.9 (1.6) cmH2O and 6.1 (0.9) cmH2O, respectively (p < .001)]. Significant differences were observed between electrical impedance tomography- and compliance-based optimal positive end-expiratory pressure. Peak and mean airway, plateau, and driving pressures increased 1 h after prone positioning compared with those in the supine position. In addition, the centre of ventilation for balance in ventilation between the ventral and dorsal regions improved. CONCLUSION: The prone position required higher positive end-expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end-expiratory pressure, which needs to be individualized.


Assuntos
Anestesia Geral , Impedância Elétrica , Respiração com Pressão Positiva , Tomografia , Humanos , Respiração com Pressão Positiva/métodos , Anestesia Geral/métodos , Decúbito Ventral/fisiologia , Decúbito Dorsal , Lactente , Estudos Prospectivos , Masculino , Feminino , Tomografia/métodos , Recém-Nascido
6.
Paediatr Anaesth ; 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39193638

RESUMO

BACKGROUND: High-flow nasal oxygenation is reported to prolong duration of apnea while maintaining adequate oxygen saturation with the mouth closed. Also, buccal oxygenation is known to have similar effects in obese adults. We compared the effect of these two methods on prolongation of acceptable apnea time in pediatric patients with their mouth open. METHODS: Thirty-eight patients, aged 0-10 years were randomly allocated to either the high-flow nasal oxygenation group (n = 17) or the buccal oxygenation group (n = 21). After induction of anesthesia including neuromuscular blockade, manual ventilation was initiated until the expiratory oxygen concentration reached 90%. Subsequently, ventilation was paused, and the patient's head was extended, and mouth was opened. The HFNO group received 2 L·min-1·kg-1 of oxygen, and the BO group received 0.5 L·min-1·kg-1 of oxygen. We set a target apnea time according to previous literature. When the apnea time reached the target, we defined the case as "success" in prolongation of safe apnea time and resumed ventilation. When the pulse oximetry decreased to 92% before the target apnea time, it was recorded as "failure" and rescue ventilation was given. RESULTS: The success rate of safe apnea prolongation was 100% in the high-flow nasal oxygenation group compared to 76% in the buccal oxygenation group (p = .04). Oxygen reserve index, end-tidal or transcutaneous carbon dioxide partial pressure, and pulse oximetry did not differ between groups. CONCLUSION: High-flow nasal oxygenation is effective in maintaining appropriate arterial oxygen saturation during apnea even in children with their mouth open and is superior to buccal oxygenation. Buccal oxygenation may be a good alternative when high-flow nasal oxygenation is not available.

7.
Paediatr Anaesth ; 34(1): 35-41, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37587734

RESUMO

BACKGROUND: Optimal pain management after insertion of a central venous catheter in children remains unclear. AIM: This study aimed to evaluate the effects of a selective supraclavicular nerve block on postoperative analgesia in pediatric patients undergoing hickman catheter or chemoport insertion. METHODS: Fifty patients aged 3-18 years scheduled for elective Hickman or chemoport insertion were randomized into two groups of 25 each: one group received an ultrasound-guided selective supraclavicular nerve block with 0.1 mL/kg of 0.5% ropivacaine (SSCNB group), and the other group did not receive a nerve block (control group). The primary outcome was the postoperative Wong-Baker Faces Pain Rating Scale score measured between 10 and 30 min after surgery. Secondary outcomes included pain scores at 1, 3, and 24 h after the surgery, block-related complications, length of stay in the postanesthesia care unit, postoperative analgesic consumption, and time to first analgesic use 24 h after surgery. RESULTS: The worst pain score within 30 min in the recovery room was significantly lower in the SSCNB group compared to the control group (6 [5-7] vs. 3 [2-4]; median difference, -3; 95% CI, -4 to -1; p < .001). Pain scores at 1, 3, and 24 h after surgery were also significantly lower in the SSCNB group. The need for both opioid and non-opioid analgesics in the postoperative period was significantly lower in the SSCNB group (36.0% vs. 0%; p = .002 and 44.0% vs. 16.0%; mean difference, -28%; 95% CI, -56 to 0.19; p = .033, respectively), while other secondary outcomes were not significantly different between the two groups. CONCLUSIONS: Ultrasound-guided SSCNB is an effective method for managing postoperative pain in children undergoing Hickman catheter or chemoport insertion, reducing the need for analgesics within 24 h after surgery.


Assuntos
Bloqueio do Plexo Braquial , Cateteres Venosos Centrais , Humanos , Criança , Anestésicos Locais/uso terapêutico , Cateteres Venosos Centrais/efeitos adversos , Ultrassonografia de Intervenção/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Bloqueio do Plexo Braquial/efeitos adversos , Analgésicos , Analgésicos Opioides
8.
Eur J Anaesthesiol ; 41(9): 687-694, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087414

RESUMO

BACKGROUND: Hypoxaemia occurs frequently during paediatric laryngeal microsurgery. OBJECTIVE: The oxygen reserve index is a noninvasive and continuous parameter to assess PaO2 levels in the range of 100 to 200 mmHg. It ranges from 0 to 1.0. We investigated whether monitoring the oxygen reserve index can reduce the incidence of SpO2 90% or less. DESIGN: Randomised controlled trial. SETTING: A tertiary care paediatric hospital. PARTICIPANTS: Paediatric patients aged 18 years or less scheduled to undergo laryngeal microsurgery. INTERVENTION: The patients were randomly allocated to the oxygen reserve index or control groups, and stratified based on the presence of a tracheostomy tube. Rescue intervention was performed when the oxygen reserve index was 0.2 or less and the SpO2 was 94% or less in the oxygen reserve index and control groups, respectively. MAIN OUTCOME MEASURE: The primary outcome was the incidence of SpO2 90% or less during the surgery. RESULTS: Data from 88 patients were analysed. The incidence of SpO2 ≤ 90% did not differ between the oxygen reserve index and control groups [P = 0.114; 11/44, 25% vs. 18/44, 40.9%; relative risk: 1.27; and 95% confidence interval (CI): 0.94 to 1.72]. Among the 128 rescue interventions, SpO2 ≤ 90% event developed in 18 out of 75 events (24%) and 42 out of 53 events (79.2%) in the oxygen reserve index and control groups, respectively (P < 0.001; difference: 55.2%; and 95% CI 38.5 to 67.2%). The number of SpO2 ≤ 90% events per patient in the oxygen reserve index group (median 0, maximum 3) was less than that in the control group (median 0, maximum 8, P = 0.031). CONCLUSION: Additional monitoring of the oxygen reserve index, with a target value of greater than 0.2 during paediatric airway surgery, alongside peripheral oxygen saturation, did not reduce the incidence of SpO2 ≤ 90%.


Assuntos
Hipóxia , Saturação de Oxigênio , Humanos , Masculino , Feminino , Hipóxia/prevenção & controle , Hipóxia/sangue , Hipóxia/etiologia , Pré-Escolar , Oxigênio/sangue , Criança , Lactente , Microcirurgia/métodos , Laringe , Oximetria/métodos , Monitorização Intraoperatória/métodos , Adolescente
9.
Eur J Anaesthesiol ; 41(9): 641-648, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38884417

RESUMO

BACKGROUND: The association between the concentration of atmospheric particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia in children receiving general anaesthesia is unclear. OBJECTIVE: To investigate the association between the exposure to particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% for more than 1 min, in children. DESIGN: Retrospective study. SETTING: Single-centre. PARTICIPANTS: Children aged 18 years or younger who received general anaesthesia between January 2019 and October 2020. INTERVENTION: Information on daily levels of particulate matter with a diameter 10 µm or less and 2.5 µm or less measured within a neighbourhood corresponding to the area defined by the hospital's zip code was obtained from publicly available air-quality data. MAIN OUTCOME MEASURES: The primary outcome was intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% lasting for more than 1 min, manually verified by anaesthesiologists using vital sign registry data extracted at 2 s intervals. RESULTS: Of the patients finally analysed, 3.85% (489/13 175) experienced intra-operative hypoxaemia. Higher levels of particulate matter 10 µm or less in diameter (≥81 µg m -3 , 17/275, 6.2%) were associated with an increased occurrence of intra-operative hypoxaemia compared with lower particulate matter concentrations [<81 µg m -3 , 472/12 900, 3.7%; adjusted odds ratio, 1.71; 95% confidence interval (CI), 1.04 to 2.83; P  = 0.035]. CONCLUSION: The level of particulate matter on the day of surgery pose a risk of intra-operative hypoxaemia in children receiving general anaesthesia. If the concentrations of particulate matter 10 µm or less in diameter on the day of surgery are high, children receiving general anaesthesia should be managed with increased caution.


Assuntos
Anestesia Geral , Hipóxia , Material Particulado , Humanos , Anestesia Geral/efeitos adversos , Estudos Retrospectivos , Material Particulado/efeitos adversos , Hipóxia/epidemiologia , Hipóxia/etiologia , Hipóxia/induzido quimicamente , Hipóxia/sangue , Masculino , Feminino , Criança , Pré-Escolar , Lactente , República da Coreia/epidemiologia , Adolescente , Oximetria , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/induzido quimicamente , Recém-Nascido , Saturação de Oxigênio
10.
Eur J Anaesthesiol ; 41(7): 522-529, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38517311

RESUMO

BACKGROUND: The effectiveness of head mounted real-time ultrasound displays (hereafter referred to as 'smart glasses') in improving hand-eye coordination in less experienced individuals, such as trainees in anaesthesia, is unclear. OBJECTIVES: To compare the first-attempt success rate of smart glasses-assisted ultrasound-guided paediatric radial artery catheterisation with conventional ultrasound guided catheterisation performed by anaesthesiology trainees. DESIGN: Prospective randomised controlled trial. SETTINGS: Tertiary university hospital from September 2021 to February 2023. PATIENTS: One hundred and twenty-two paediatric patients (age <7 years, weight ≥3 kg) who required radial artery cannulation during general anaesthesia. INTERVENTIONS: The participants were randomly assigned to either the ultrasound screen group (control) or the smart glasses group prior to radial artery catheterisation. MAIN OUTCOME MEASURES: The primary outcome was the first attempt success rate. Secondary outcomes included the number of attempts, use of transfixion technique, overall complication rate, and clinical anaesthesiology (CA) year of the operators. RESULTS: A total of 119 paediatric patients were included in the analysis. The smart glasses group exhibited higher first-attempt success rate than did the control group (89.8% [53/59] vs. 71.7% [43/60]; P  = 0.023; odds ratio (OR) 3.49; (95% confidence interval (CI) 1.27-9.6). The overall number of attempts [median, 1; interquartile range (IQR), 1-1; range, 1-3 vs. median, 1; IQR, 1-2; range, 1-4; P   =  0.006], use of transfixion technique (12/59 [20.3%] vs. 28/60 [46.7%]; P  = 0.002), and overall complication rate (6.8% [4/59] vs. 30.0% [18/60]; P  = 0.002) were lower in the smart glasses group than in the control group. However, among paediatric anaesthesiology fellows (CA 5 years), the first- (89.3% [25/28] vs. 80.8% [21/26]; P  = 0.619) and second-attempt success rates (96.4% [27/28] vs. 80.8% [21/26]; P  = 0.163) did not differ between the two groups. CONCLUSIONS: Smart glasses-assisted ultrasound guided radial artery catheterisation improved the first attempt success rate among anaesthesiology trainees, reducing the number of attempts and overall complication rates in small paediatric patients. Smart glasses were more effective for anaesthesia residents (CA 2-4 years) but were not effective for paediatric anaesthesiology fellows (CA 5 years). TRIAL REGISTRATION: ClinicalTrials.gov (NCT05030649) ( https://classic.clinicaltrials.gov/ct2/show/NCT05030649 ).


Assuntos
Anestesiologia , Cateterismo Periférico , Artéria Radial , Ultrassonografia de Intervenção , Humanos , Artéria Radial/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Cateterismo Periférico/métodos , Anestesiologia/educação , Pré-Escolar , Criança , Lactente , Óculos Inteligentes , Anestesia Geral , Competência Clínica , Cabeça
11.
Eur J Anaesthesiol ; 41(9): 649-656, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38832435

RESUMO

BACKGROUND: The potential benefits of Analgesia Nociception Index guided intra-operative analgesia on intra-operative opioid consumption remains to be demonstrated in paediatric anaesthesia. OBJECTIVES: This study aimed to explore the effects of Analgesia Nociception Index guided analgesia on sufentanil consumption during anaesthesia and postoperative pain scores in paediatric patients with moyamoya disease. DESIGN: A prospective randomised controlled study. SETTING: Seoul National University Children's Hospital, Seoul, Republic of Korea. PATIENTS: A total of 40 children scheduled for encephaloduroarteriosynangiosis. MAIN OUTCOME MEASURES: The primary outcome was total intra-operative sufentanil consumption, and the secondary outcomes included postoperative pain scores and incidence of opioid-related adverse events. RESULTS: The Analgesia Nociception Index group showed lower intra-operative sufentanil consumption (in µg kg -1  h -1 ) compared with the Standard group (0.30 ±â€Š0.12 and 0.39 ±â€Š0.17, respectively; mean difference, -0.09; 95% confidence interval, -0.19 to 0.00; P  = 0.049). Postoperatively, compared with the Standard group, the Analgesia Nociception Index group reported lower median pain scores at 18 and 24 h and maximum pain within 24 h (1 [0 to 2] vs. 3 [2 to 5]; P  = 0.004, 1 [0 to 2] vs. 3 [1 to 4]; P  = 0.041, and 4 [3 to 5] vs. 5 [4 to 7]; P  = 0.045, respectively), with fewer patients experiencing nausea (3 [15%] vs. 10 [50%], P  = 0.043). CONCLUSION: The Analgesia Nociception Index guided analgesic protocol can reduce intra-operative sufentanil consumption and postoperative pain within 24 h with fewer nausea symptoms in paediatric patients with moyamoya disease who undergo encephaloduroarteriosynangiosis. TRIAL REGISTRATION NUMBER: NCT05672212.


Assuntos
Analgésicos Opioides , Doença de Moyamoya , Nociceptividade , Dor Pós-Operatória , Sufentanil , Humanos , Doença de Moyamoya/cirurgia , Feminino , Masculino , Criança , Estudos Prospectivos , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Sufentanil/administração & dosagem , Nociceptividade/efeitos dos fármacos , Analgésicos Opioides/administração & dosagem , Pré-Escolar , Analgesia/métodos , Medição da Dor/métodos , Adolescente , Resultado do Tratamento
12.
Chem Biodivers ; 21(4): e202301115, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38334224

RESUMO

In this study, three diterpenoids (1-3), including one known compound (1), were isolated from the fruits of Vitex rotundifolia and their structures were determined via spectroscopic analysis. In lipopolysaccharide-stimulated RAW264.7 cells, these compounds dose-dependently decreased the intracellular reactive oxygen species levels and nitric oxide production compared to those in the control cells. At 25 µM/mL, these compounds also diminished the protein expression of the pro-inflammatory cytokines, inducible nitric oxide synthase, cyclooxygenase-2, and interleukin-6, with compound 3 exhibiting the most potent inhibitory effect.


Assuntos
Diterpenos , Vitex , Vitex/química , Antioxidantes/farmacologia , Plantas Tolerantes a Sal/metabolismo , Anti-Inflamatórios/farmacologia , Diterpenos/farmacologia , Diterpenos/química , Óxido Nítrico/metabolismo , Lipopolissacarídeos/farmacologia , Óxido Nítrico Sintase Tipo II/metabolismo
13.
Int J Mol Sci ; 25(12)2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38928481

RESUMO

Ischemic stroke is a major cause of mortality worldwide. Proper etiological subtyping of ischemic stroke is crucial for tailoring treatment strategies. This study explored the utility of circulating microRNAs encapsulated in extracellular vesicles (EV-miRNAs) to distinguish the following ischemic stroke subtypes: large artery atherosclerosis (LAA), cardioembolic stroke (CES), and small artery occlusion (SAO). Using next-generation sequencing (NGS) and machine-learning techniques, we identified differentially expressed miRNAs (DEMs) associated with each subtype. Through patient selection and diagnostic evaluation, a cohort of 70 patients with acute ischemic stroke was classified: 24 in the LAA group, 24 in the SAO group, and 22 in the CES group. Our findings revealed distinct EV-miRNA profiles among the groups, suggesting their potential as diagnostic markers. Machine-learning models, particularly logistic regression models, exhibited a high diagnostic accuracy of 92% for subtype discrimination. The collective influence of multiple miRNAs was more crucial than that of individual miRNAs. Additionally, bioinformatics analyses have elucidated the functional implications of DEMs in stroke pathophysiology, offering insights into the underlying mechanisms. Despite limitations like sample size constraints and retrospective design, our study underscores the promise of EV-miRNAs coupled with machine learning for ischemic stroke subtype classification. Further investigations are warranted to validate the clinical utility of the identified EV-miRNA biomarkers in stroke patients.


Assuntos
Biomarcadores , MicroRNA Circulante , Exossomos , AVC Isquêmico , Aprendizado de Máquina , Humanos , AVC Isquêmico/sangue , AVC Isquêmico/genética , AVC Isquêmico/diagnóstico , Masculino , MicroRNA Circulante/sangue , MicroRNA Circulante/genética , Feminino , Idoso , Pessoa de Meia-Idade , Exossomos/genética , Exossomos/metabolismo , Biomarcadores/sangue , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Biologia Computacional/métodos , MicroRNAs/sangue , MicroRNAs/genética , Perfilação da Expressão Gênica/métodos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/genética
14.
EMBO J ; 38(24): e101196, 2019 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-31750563

RESUMO

Parkinson's disease (PD) is neurodegenerative movement disorder characterized by degeneration of midbrain-type dopamine (mDA) neurons in the substantia nigra (SN). The RNA-binding protein Lin28 plays a role in neuronal stem cell development and neuronal differentiation. In this study, we reveal that Lin28 conditional knockout (cKO) mice show degeneration of mDA neurons in the SN, as well as PD-related behavioral deficits. We identify a loss-of-function variant of LIN28A (R192G substitution) in two early-onset PD patients. Using an isogenic human embryonic stem cell (hESC)/human induced pluripotent stem cell (hiPSC)-based disease model, we find that the Lin28 R192G variant leads to developmental defects and PD-related phenotypes in mDA neuronal cells that can be rescued by expression of wild-type Lin28A. Cell transplantation experiments in PD model rats show that correction of the LIN28A variant in the donor patient (pt)-hiPSCs leads to improved behavioral phenotypes. Our data link LIN28A to PD pathogenesis and suggest future personalized medicine targeting this variant in patients.


Assuntos
Doença de Parkinson/metabolismo , Proteínas de Ligação a RNA/genética , Proteínas de Ligação a RNA/fisiologia , Substância Negra/metabolismo , Animais , Comportamento Animal , Transplante de Células , Modelos Animais de Doenças , Dopamina/metabolismo , Neurônios Dopaminérgicos/fisiologia , Células-Tronco Embrionárias/fisiologia , Edição de Genes , Predisposição Genética para Doença , Humanos , Células-Tronco Pluripotentes Induzidas/fisiologia , Células-Tronco Pluripotentes Induzidas/transplante , Camundongos , Camundongos Knockout , Mutação , Células-Tronco Neurais/fisiologia , Células-Tronco Neurais/transplante , Doença de Parkinson/genética , Ratos , Transplante de Células-Tronco
15.
Anesth Analg ; 136(6): 1067-1074, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36727868

RESUMO

BACKGROUND: Perioperative respiratory adverse events are common in children. We aimed to evaluate the effect of the transdermal ß-2 agonist, tulobuterol, compared with that of placebo on the incidence of perioperative respiratory adverse events in pediatric patients undergoing tonsillectomy. METHODS: In this triple-blinded (patient, anesthesia provider, and outcome assessor) randomized controlled trial, 188 patients were randomly allocated to receive tulobuterol or a placebo. The tulobuterol groups received a tulobuterol patch (1 mg) masked with a bandage, whereas the placebo only received the bandage. The assigned bandage was applied to the patients 8 to 10 hours before the surgery. The primary outcome was the occurrence of any perioperative respiratory adverse events: oxygen desaturation <95%, airway obstruction, laryngospasm, bronchospasm, severe coughing, or stridor. The outcomes were evaluated using the average relative effect test, which estimates the effect of individual components of a composite outcome and then averages effects across components. RESULTS: A total of 88 and 94 patients who received tulobuterol and placebo, respectively, were analyzed. The incidence of any perioperative respiratory adverse event was lower with tulobuterol (n = 13/88; 14.7%) than that with the placebo (n = 40/94; 42.5%), with an estimated average relative risk (95% confidence interval) across components of 0.35 (0.20-0.60; P < .001). The symptoms of airway obstruction were lower with tulobuterol (n = 8/88; 9.0%) than that with the placebo (n = 32/94; 34.0%), with relative risk (95% CI) of 0.31 (0.17-0.56; P < .001). The occurrence of severe coughing was lower with tulobuterol (n = 1/88; 1.1%) than that with the placebo (n = 8/94; 8.5%), with relative risk (95% CI) of 0.15 (0.03-0.68; P = .014). CONCLUSIONS: In preschool children undergoing tonsillectomy, the preoperative application of a tulobuterol patch could decrease the occurrence of perioperative respiratory adverse events. Further studies are needed to elucidate the effect of the tulobuterol patch in a broad spectrum of pediatric anesthesia.


Assuntos
Obstrução das Vias Respiratórias , Tonsilectomia , Pré-Escolar , Humanos , Criança , Tonsilectomia/efeitos adversos , Terbutalina/efeitos adversos , Tosse/induzido quimicamente , Tosse/epidemiologia , Tosse/prevenção & controle
16.
Can J Anaesth ; 70(12): 1957-1969, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919629

RESUMO

PURPOSE: Increased portal venous flow pulsatility is associated with major complications after adult cardiac surgery. Nevertheless, no data are available for pediatric patients with congenital heart disease. We hypothesized that Doppler parameters including portal flow pulsatility could be associated with postoperative outcomes in children undergoing various cardiac surgeries. METHODS: We conducted a prospective observational cohort study in children undergoing congenital cardiac surgery. We obtained postoperative portal, splenic, and hepatic venous Doppler data and perioperative clinical data including major postoperative complications. Portal and splenic venous flow pulsatility were calculated. We evaluated the association between venous Doppler parameters and adverse outcomes. The primary objective was to determine whether postoperative portal flow pulsatility could indicate major complications following congenital heart surgery. RESULTS: In this study, we enrolled 389 children, 74 of whom experienced major postoperative complications. The mean (standard deviation) portal pulsatility (44 [30]% vs 25 [14]%; 95% confidence interval [CI] for mean difference, 12 to 26; P < 0.001] and splenic pulsatility indices (41 [30]% vs 26 [16]%; 95% CI, 7 to 23; P < 0.001) were significantly higher in children with postoperative complications than in those without complications. The portal pulsatility index was able to help identify postoperative complications in biventricular patients and univentricular patients receiving bidirectional cavopulmonary shunt whereas it did not in other univentricular patients. An increased postoperative portal pulsatility index was significantly associated with major complications after pediatric cardiac surgery (odds ratio, 1.40; 95% CI, 1.29 to 1.91; P < 0.001). CONCLUSIONS: Higher portal venous pulsatility is associated with major postoperative complications in children undergoing cardiac surgery. Nevertheless, more data are needed to conclude the efficacy of portal venous pulsatility in patients with univentricular physiology. STUDY REGISTRATION: ClinicalTrials.gov (NCT03990779); registered 19 June 2019.


RéSUMé: OBJECTIF: L'augmentation de la pulsatilité du flux de la veine porte est associée à des complications majeures après une chirurgie cardiaque chez l'adulte. Néanmoins, aucune donnée n'est disponible pour la patientèle pédiatrique atteinte de cardiopathie congénitale. Nous avons émis l'hypothèse que les paramètres Doppler, y compris la pulsatilité du flux de la veine porte, pourraient être associés aux devenirs postopératoires des enfants bénéficiant de diverses chirurgies cardiaques. MéTHODE: Nous avons réalisé une étude de cohorte observationnelle prospective portant sur des enfants bénéficiant d'une chirurgie cardiaque congénitale. Nous avons obtenu des données Doppler des veines porte, spléniques et hépatiques postopératoires ainsi que des données cliniques périopératoires, y compris les complications postopératoires majeures. La pulsatilité du flux des veines porte et spléniques a été calculée. Nous avons évalué l'association entre les paramètres Doppler veineux et les issues indésirables. L'objectif principal était de déterminer si la pulsatilité du flux postopératoire de la veine porte pouvait constituer un indicateur des complications majeures après une chirurgie cardiaque congénitale. RéSULTATS: Dans cette étude, nous avons recruté 389 enfants, dont 74 ont présenté des complications postopératoires majeures. La pulsatilité moyenne de la veine porte (écart type) (44 [30] % vs 25 [14] %; intervalle de confiance [IC] à 95 % pour la différence moyenne, 12 à 26; P < 0,001] et les indices de pulsatilité splénique (41 [30] % vs 26 [16] %; IC 95 %, 7 à 23; P < 0,001) étaient significativement plus élevés chez les enfants présentant des complications postopératoires que chez les enfants sans complications. L'indice de pulsatilité de la veine porte a permis d'identifier les complications postopératoires chez les patient·es biventriculaires et les patient·es univentriculaires recevant une anastomose cavo-pulmonaire bidirectionnelle (procédure de Glenn), alors que ce n'était pas le cas chez les autres patient·es univentriculaires. Une augmentation postopératoire de l'indice de pulsatilité de la veine porte était significativement associée à des complications majeures après une chirurgie cardiaque pédiatrique (rapport de cotes, 1,40; IC 95 %, 1,29 à 1,91; P < 0,001). CONCLUSION: Une pulsatilité plus élevée de la veine porte est associée à des complications postopératoires majeures chez les enfants bénéficiant d'une chirurgie cardiaque. Néanmoins, davantage de données sont nécessaires pour conclure à l'efficacité de la pulsatilité de la veine porte chez les patient·es présentant une physiologie univentriculaire. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT03990779); enregistrée le 19 juin 2019.


Assuntos
Cardiopatias Congênitas , Veia Porta , Criança , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Veia Porta/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Ultrassonografia Doppler
17.
J Cardiothorac Vasc Anesth ; 37(8): 1456-1468, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37183119

RESUMO

OBJECTIVE: Little is known about changes in portal, splenic, and hepatic vein flow patterns in children undergoing congenital heart surgery. This study aimed to determine the characteristics of portal, splenic, and hepatic vein flow patterns using ultrasonography in children undergoing cardiac surgery. DESIGN: Single-center, prospective observational study. SETTING: Tertiary children's hospital, operating room. PARTICIPANTS: Children undergoing cardiac surgery. MEASUREMENT AND MAIN RESULTS: The authors obtained ultrasound data from the heart, inferior vena cava, portal, splenic, and hepatic veins before and after surgeries. In the biventricular group, which included children with atrial and ventricular septal defects and pulmonary stenosis (n = 246), the portal pulsatility index decreased from 38.7% to 25.6% (p < 0.001) after surgery. The preoperative portal pulsatility index was significantly higher in patients with pulmonary hypertension (43.3% v 27.4%; p < 0.001). In the single-ventricle group (n = 77), maximum portal vein flow velocities of Fontan patients were significantly lower (13.5 cm/s) compared with that of patients with modified Blalock-Taussig shunt (19.7 cm/s; p = 0.035) or bidirectional cavopulmonary shunt (23.1 cm/s; p < 0.001). The cardiac index was inversely correlated with the portal pulsatility index in the bidirectional cavopulmonary shunt and Fontan circulation. (ß = -5.693, r2 = 0.473; p = 0.001) The portal pulsatility index was correlated with splenic venous pulsatility and hepatic venous atrial reverse flow velocity in biventricular and single-ventricle groups. CONCLUSIONS: The characteristics of venous Doppler patterns in the portal, splenic, and hepatic veins differed according to congenital heart disease. Further studies are required to determine the association between splanchnic venous Doppler findings and clinical outcomes in this population.


Assuntos
Fibrilação Atrial , Técnica de Fontan , Cardiopatias Congênitas , Humanos , Criança , Veias Hepáticas/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Velocidade do Fluxo Sanguíneo
18.
Paediatr Anaesth ; 33(7): 562-570, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37061868

RESUMO

BACKGROUND: The light reflex, which reflects central nervous system dysfunction, can also be affected by anesthetic agents. AIMS: We evaluated whether these effects differed according to the anesthetic agent in pediatric patients. METHODS: Twenty children aged 3-12 years who were scheduled to undergo elective surgery under general anesthesia were randomly allocated to propofol and sevoflurane groups and underwent pupillometric assessments at five points during anesthesia: T1, after confirming loss of consciousness; T2, after endotracheal intubation; T3, at the time of skin incision; T4, 1 h after skin incision; and T5, before endotracheal extubation. The primary outcome was the Neurological Pupil index at T4, and the secondary outcomes were other pupillometric parameters, including pupil diameter, percentage of change in pupil diameter, dilation velocity, and constriction velocity. RESULTS: At T4, the Neurological Pupil index was significantly lower in the sevoflurane group (median difference, 0.30; 95% CI, 0.00 to 0.70; p = .036). Furthermore, the Neurological Pupil index at all time points was lower in the sevoflurane group. The time-and-group interaction effects on constriction velocity and dilation velocity were significantly different [F(1, 4) = 16.68, p = .002; F(1, 4) = 14.78, p = .008, respectively] but were not different on the Neurological Pupil index, pupil diameter, and percentage of change in pupil diameter. No intergroup differences were observed in the baseline characteristics, the flow rate of remifentanil at each time point, and total infused remifentanil. CONCLUSION: The Neurological Pupil index value in pediatric patients under general anesthesia is affected by the anesthetic agent used; this factor requires consideration in evaluations of the Neurological Pupil index during general anesthesia.


Assuntos
Anestésicos Intravenosos , Propofol , Humanos , Criança , Anestésicos Intravenosos/farmacologia , Remifentanil , Sevoflurano , Propofol/farmacologia , Anestesia Geral , Anestesia Intravenosa
19.
Paediatr Anaesth ; 33(4): 303-311, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36594749

RESUMO

BACKGROUND: Cardiopulmonary bypass can affect the pharmacokinetics of anesthetic agents. AIMS: We aimed to evaluate the pharmacokinetics of dexmedetomidine for infants and small children undergoing cardiac surgery with cardiopulmonary bypass based on population pharmacokinetics. METHODS: We enrolled 30 pediatric cardiac surgical patients in this study. After anesthetic induction with atropine (0.02 mg/kg), thiopental sodium (5 mg/kg), and fentanyl (2-3 µg/kg), we administered 1 µg/kg of dexmedetomidine for 10 min, followed by administration of 0.5 µg/kg of dexmedetomidine per hour during surgery. At the initiation of cardiopulmonary bypass, 1 µg/kg of dexmedetomidine was infused over 5 min. Arterial blood was obtained at predefined time points. A pharmacokinetic model was developed using NONMEM. Theory-based allometric scaling with fixed exponents was applied. Weight, age, post-menstrual age, fat-free mass, whether to implement cardiopulmonary bypass and temperature were explored as covariates. RESULTS: A total of 376 blood samples were obtained from 29 children (age: 20.3 ± 19.3 months, weight: 9.7 ± 4.1 kg). A two-compartment mammillary model with third compartment associated cardiopulmonary bypass procedure best explained the pharmacokinetics of dexmedetomidine. The pharmacokinetic parameter estimates (95% CI) standardized to a 70-kg person were as follows: V1 (L) = 31.6 (17.9-39.5), V2 (L) = 90.1 (44.0-330), Cl (L/min) = 1.08 (0.70-1.25), Q (L/min) = 2.0 (1.05-3.46). Volume for third compartment associated cardiopulmonary bypass procedure (L) = 39.4 (19.3-50.9). Clearance was not influenced by the presence of cardiopulmonary bypass in this model. CONCLUSION: When cardiopulmonary bypass is applied, the plasma concentration of dexmedetomidine decreases due to an increase in the volume of distribution, so a loading dose is required to maintain the previous concentration.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Dexmedetomidina , Lactente , Criança , Humanos , Pré-Escolar , Hipnóticos e Sedativos , Ponte Cardiopulmonar , Fentanila
20.
Paediatr Anaesth ; 33(11): 930-937, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37641455

RESUMO

INTRODUCTION: It is known that pulse pressure variation and systolic pressure variation cannot predict fluid responsiveness in children. In adults, the ability of these dynamic parameters to predict fluid responsiveness is improved by increasing tidal volume. We planned to investigate whether pulse pressure variation or systolic pressure variation can predict fluid responsiveness in children when augmented by increasing tidal volume by conducting a prospective study. METHODS: We enrolled children younger than 7 years who underwent cardiac surgery for atrial septal defect or ventricular septal defect. After sternum closure, pulse pressure variation and systolic pressure variation were continuously recorded while changing the tidal volume to 6, 10, and 14 mL/kg. Fluid loading was done with 10 mL/kg of crystalloids for 10 min, and stroke volume index was measured via transesophageal echocardiography. Children whose stroke volume index increased by more than 15% after the fluid loading were defined as responders to fluid therapy. We set primary outcome as the predictability of pulse pressure variation and systolic pressure variation for fluid responsiveness and measured the area under the curve of receiver operating characteristics curve. RESULTS: Twenty-six children were included, of which 15 were responders. At the tidal volume of 14 mL/kg, the area under the curves of receiver operating characteristics curves of pulse pressure variation and systolic pressure variation were 0.576 (p = .517) and 0.548 (p = .678), respectively. The differences in dynamic parameters between responders and nonresponders were not significant. DISCUSSION: Failure of pulse pressure variation or systolic pressure variation at augmented tidal volume in children may be due to difference in their arterial compliance from those of adults. Large compliance of thoracic wall may be another reason. CONCLUSIONS: Augmented pulse pressure variation or systolic pressure variation due to increased tidal volume cannot predict fluid responsiveness in children after simple cardiac surgery.


Assuntos
Hidratação , Hemodinâmica , Adulto , Humanos , Criança , Estudos Prospectivos , Volume de Ventilação Pulmonar , Pressão Sanguínea , Volume Sistólico , Frequência Cardíaca , Curva ROC , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA