Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026063

RESUMO

OBJECTIVES: The aim of this study is to develop a deep-learning model to create synthetic temporal bone computed tomography (CT) images from ultrashort echo-time magnetic resonance imaging (MRI) scans, thereby addressing the intrinsic limitations of MRI in localizing anatomic landmarks in temporal bone CT. MATERIALS AND METHODS: This retrospective study included patients who underwent temporal MRI and temporal bone CT within one month between April 2020 and March 2023. These patients were randomly divided into training and validation datasets. A CycleGAN model for generating synthetic temporal bone CT images was developed using temporal bone CT and pointwise encoding-time reduction with radial acquisition (PETRA). To assess the model's performance, the pixel count in mastoid air cells was measured. Two neuroradiologists evaluated the successful generation rates of 11 anatomical landmarks. RESULTS: A total of 102 patients were included in this study (training dataset, n = 54, mean age 58 ± 14, 34 females (63%); validation dataset, n = 48, mean age 61 ± 13, 29 females (60%)). In the pixel count of mastoid air cells, no difference was observed between synthetic and real images (679 ± 342 vs 738 ± 342, p = 0.13). For the six major anatomical sites, the positive generation rates were 97-100%, whereas those of the five major anatomical structures ranged from 24% to 83%. CONCLUSION: We developed a model to generate synthetic temporal bone CT images using PETRA MRI. This model can provide information regarding the major anatomic sites of the temporal bone using MRI. CLINICAL RELEVANCE STATEMENT: The proposed algorithm addresses the primary limitations of MRI in localizing anatomic sites within the temporal bone. KEY POINTS: CT is preferred for imaging the temporal bone, but has limitations in differentiating pathology there. The model achieved a high success rate in generating synthetic images of six anatomic sites. This can overcome the limitations of MRI in visualizing key anatomic sites in the temporal skull.

2.
Healthcare (Basel) ; 12(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38201011

RESUMO

This study developed an information and communication technology-based mobile application to administer cognitive behavioral therapy to community-dwelling older adults with insomnia. First, the content of the application was determined through a systematic review and preference survey. Preference data on the perception, needs, and preference for non-face-to-face service content were collected from 15 July 2021 to 31 August 2021 from 100 community-dwelling older adults aged 65 years and older. In the design stage, the structure and function of the application were determined, and an interface was designed. The application was developed in conjunction with design experts and programmers using Android Studio software (Android 9). Usability tests were conducted during the implementation stage, followed by an evaluation stage. The evaluation revealed that the application's structure and functions should comprise sleep information, sleep-habit improvement, sleep assistance, video, real-time counseling, and exercise services. These elements were finalized after receiving the results of a preference analysis and advice from an advisory panel of experts in different fields. The developed application was rated with a score of four or higher in all areas. This study successfully developed, implemented, and evaluated a new mobile application called Smart Sleep for community-dwelling older adults with insomnia.

3.
Quant Imaging Med Surg ; 14(5): 3432-3446, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720859

RESUMO

Background: Image-based assessment of prostate cancer (PCa) is increasingly emphasized in the diagnostic workflow for selecting biopsy targets and possibly predicting clinically significant prostate cancer (csPCa). Assessment is based on Prostate Imaging-Reporting and Data System (PI-RADS) which is largely dependent on T2-weighted image (T2WI) and diffusion weighted image (DWI). This study aims to determine whether deep learning reconstruction (DLR) can improve the image quality of DWI and affect the assessment of PI-RADS ≥4 in patients with PCa. Methods: In this retrospective study, 3.0T post-biopsy prostate magnetic resonance imaging (MRI) of 70 patients with PCa in Korea University Ansan Hospital from November 2021 to July 2022 was reconstructed with and without using DLR. Four DWI image sets were made: (I) conventional DWI (CDWI): DWI with acceleration factor 2 and conventional parallel imaging reconstruction, (II) DL1: DWI with acceleration factor 2 using DLR, (III) DL2: DWI with acceleration factor 3 using DLR, and (IV) DL3: DWI with acceleration factor 3 and half average b-value using DLR. Apparent diffusion coefficient (ADC) value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured by one reviewer, while two reviewers independently assessed overall image quality, noise, and lesion conspicuity using a four-point visual scoring system from each DWI image set. Two reviewers also performed PI-RADSv2.1 scoring on lesions suspected of malignancy. Results: A total of 70 patients (mean age, 70.8±9.7 years) were analyzed. The image acquisition time was 4:46 min for CDWI and DL1, 3:40 min for DL2, and 2:00 min for DL3. DL1 and DL2 images resulted in better lesion conspicuity compared to CDWI images assessed by both readers (P<0.05). DLR resulted in a significant increase in SNR, from 38.4±14.7 in CDWI to 56.9±21.0 in DL1. CNR increased from 25.1±11.5 in CDWI to 43.1±17.8 in DL1 (P<0.001). PI-RADS v2.1 scoring for PCa lesions was more agreeable with the DL1 reconstruction method than with CDWI (κ value CDWI, DL1; 0.40, 0.61, respectively). A statistically significant number of lesions were upgraded from PI-RADS <4 in CDWI image to PI-RADS ≥4 in DL1 images for both readers (P<0.05). Most of the PI-RADS upgraded lesions were from higher than unfavorable intermediate-risk groups according to the 2023 National Comprehensive Cancer Network guidelines with statistically significant difference of marginal probability in DL1 and DL2 for both readers (P<0.05). Conclusions: DLR in DWI for PCa can provide options for improving image quality with a significant impact on PI-RADS evaluation or about a 23% reduction in acquisition time without compromising image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA