Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Surg Oncol ; 123(4): 866-871, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33333584

RESUMO

BACKGROUND: Intraoperative near-infrared imaging (NIFI) of parathyroid glands (PG) by first-generation technology had limited image quality and depth penetration. Second-generation NIFI has recently been introduced. Our aim was to compare (1) capability to detect PG and (2) image quality between older and newer technologies. METHODS: Accurately detecting PG, as well as, quality of autofluorescence (AF) was compared between an older charge-coupled device (CCD) camera and a newer complementary metal-oxide semiconductor (CMOS). χ2 , t test, and analysis of variance were used for analysis. RESULTS: There were 300 patients who underwent parathyroidectomy (PTX) and/or thyroidectomy (THY) with NIFI, 200 with CCD, and 100 with CMOS. Although both NIFI technologies detected >94% of PG, CMOS was superior to CCD. Comparing AF quality, mean pixel intensity of PG compared with the background was higher with CMOS compared with CCD. When comparing PG detected by NIFI before visual identification by a surgeon, both CCD and CMOS had similar results (25% vs. 22%; p = .3). CONCLUSION: Both NIFI cameras were excellent at detecting PG. Second-generation NIFI (CMOS) displayed higher detection rates and AF intensity. Although surgeons identified majority of PG before NIFI detection, 25% of PG were identified with NIFI first, suggesting future advancements of this technology may expand its applications during parathyroid/thyroid operations.


Assuntos
Imagem Óptica/métodos , Doenças das Paratireoides/patologia , Glândulas Paratireoides/patologia , Semicondutores , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Feminino , Humanos , Masculino , Metais/química , Pessoa de Meia-Idade , Doenças das Paratireoides/diagnóstico por imagem , Doenças das Paratireoides/cirurgia , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Paratireoidectomia , Prognóstico , Estudos Prospectivos
2.
Int J Med Robot ; 17(2): e2203, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33185308

RESUMO

BACKGROUND: The aim was to compare intraoperative conduct of adrenalectomy between laparoscopic and robotic approaches. METHODS: Intraoperative video-recordings of patients who underwent robotic (n = 30) and laparoscopic adrenalectomy (n = 30) were analysed using Mann-Whitney U, chi-square and multivariate regression analyses. RESULTS: Demographics, indications and outcomes were similar between groups. For all tumour sizes, camera was more engaged to surgical task and exhibited less vision problems in robotic versus laparoscopic group. There was less instrument exchange and restriction of exposure with robotic approach. For dissection, robotic approach allowed for a wider range of instrument reach around adrenal. Robotically, there was an increased ability to do fine dissection, rather than en bloc division with rigid laparoscopic vessel sealers. Bleeding problems were less robotically. CONCLUSION: Despite similarities in post-operative morbidity and hospital stay, there was a superiority in quality of procedure performed with robotic versus laparoscopic adrenalectomy for both small and large adrenal tumours.


Assuntos
Neoplasias das Glândulas Suprarrenais , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia , Humanos
3.
Laryngoscope ; 125(2): 493-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25124863

RESUMO

OBJECTIVES/HYPOTHESIS: To verify the reliability and validity of automated scoring and compare it to that of manual scoring for diagnosing obstructive sleep apnea using an Embletta X100 level 2 portable device. STUDY DESIGN: Retrospective study. METHODS: A total of 116 patients with suspected obstructive sleep apnea who had successfully received portable polysomnography with the Embletta X100 were examined. All polysomnography data were analyzed by automated and manual methods. Manual scoring was performed according to the revised American Academy of Sleep Medicine 2012 criteria. Automated scoring was analyzed using the automatic algorithm, which was updated with the American Academy of Sleep Medicine 2012 criteria. All parameters were evaluated statistically using correlation analysis and paired t tests. RESULTS: The apnea-hypopnea index for automated scoring and manual scoring with the Embletta X100 were moderately correlated (r = 0.76, P < .001). However, there was poor agreement (Bland-Altman plot, κ = 0.34, 0.33, and 0.26; cutoff value = 5, 15, and 30), and the apnea-hypopnea index data were generally excessively underestimated based on diagnostic agreement and disagreement criteria. Furthermore, the apnea-hypopnea index severity (Kendall tau-b = 0.62) between automated and manual scoring lacked good concordance. CONCLUSIONS: Automated scoring using the Embletta X100 was statistically moderately related to the manual scoring results. However, automated scoring tended to excessively underestimate the apnea-hypopnea index data compared to manual scoring. Thus, manual scoring by a sleep expert is essential for obstructive sleep apnea diagnosis with the Embletta X100. LEVEL OF EVIDENCE: 4.


Assuntos
Polissonografia/instrumentação , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Feminino , Humanos , Masculino , Monitorização Ambulatorial/instrumentação , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA