Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Mol Sci ; 23(12)2022 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-35743050

RESUMO

Fungal infections of the lung are an increasing problem worldwide and the search for novel therapeutic agents is a current challenge due to emerging resistance to current antimycotics. The volatile defence substance allicin is formed naturally by freshly injured garlic plants and exhibits broad antimicrobial potency. Chemically synthesised allicin was active against selected fungi upon direct contact and via the gas phase at comparable concentrations to the pharmaceutically used antimycotic amphotericin B. We investigated the suppression of fungal growth by allicin vapour and aerosols in vitro in a test rig at air flow conditions mimicking the human lung. The effect of allicin via the gas phase was enhanced by ethanol. Our results suggest that allicin is a potential candidate for development for use in antifungal therapy for lung and upper respiratory tract infections.


Assuntos
Micoses , Ácidos Sulfínicos , Dissulfetos , Humanos , Pulmão , Micoses/tratamento farmacológico , Ácidos Sulfínicos/química , Ácidos Sulfínicos/farmacologia , Ácidos Sulfínicos/uso terapêutico
2.
Artif Organs ; 41(6): 529-538, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27925231

RESUMO

Flow distribution is key in artificial lungs, as it directly influences gas exchange performance as well as clot forming and blood damaging potential. The current state of computational fluid dynamics (CFD) in artificial lungs can only give insight on a macroscopic level due to model simplification applied to the fiber bundle. Based on our recent work on wound fiber bundles, we applied particle image velocimetry (PIV) to the model of an artificial lung prototype intended for neonatal use to visualize flow distribution in a stacked fiber bundle configuration to (i) evaluate the feasibility of PIV for artificial lungs, (ii) validate CFD in the fiber bundle of artificial lungs, and (iii) give a suggestion how to incorporate microscopic aspects into mainly macroscopic CFD studies. To this end, we built a fully transparent model of an artificial lung prototype. To increase spatial resolution, we scaled up the model by a factor of 5.8 compared with the original size. Similitude theory was applied to ensure comparability of the flow distribution between the device of original size and the scaled-up model. We focused our flow investigation on an area (20 × 70 × 43 mm) in a corner of the model with a Stereo-PIV setup. PIV data was compared to CFD data of the original sized artificial lung. From experimental PIV data, we were able to show local flow acceleration and declaration in the fiber bundle and meandering flow around individual fibers, which is not possible using state-of-the-art macroscopic CFD simulations. Our findings are applicable to clinically used artificial lungs with a similar stacked fiber arrangement (e.g., Novalung iLa and Maquet QUADROX-I). With respect to some limitations, we found PIV to be a feasible experimental flow visualization technique to investigate blood-sided flow in the stacked fiber arrangement of artificial lungs.


Assuntos
Velocidade do Fluxo Sanguíneo , Hidrodinâmica , Pulmão/irrigação sanguínea , Oxigenadores de Membrana , Reologia/métodos , Ventiladores Mecânicos , Simulação por Computador , Desenho de Equipamento , Hemodinâmica , Humanos , Modelos Cardiovasculares
3.
Clin Biomech (Bristol, Avon) ; 76: 105029, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32422391

RESUMO

BACKGROUND: Multiple drug resistance of a growing number of bacterial pathogens represents an increasing challenge in conventional curative treatments of infectious diseases. However, the development and testing of new antibiotics is associated with a high number of animal experiments. METHODS: A symmetrical parametrized lung test rig allowing the exposure of air-passage surfaces to antibiotics was designed and tested to demonstrate proof-of-principle with aerosols containing allicin, which is an antimicrobial natural product from garlic. An artificial lung surface is coated with bacteria embedded in a hydrogel and growth inhibition is visualized by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide, that is reduced from colourless to the dark blue formazan in the presence of metabolically active, living cells. A nebulizer is used to generate the aerosols. FINDINGS: The results show that allicin has an antibiotic effect as an aerosol and that the deposition pattern of the active agent occurred mainly around the carinal regions. INTERPRETATION: The model represents an integral system for continuous, spatial detection of aerosol deposition and allows the analysis of bacterial behaviour and the toxicity of the active agent. Thus, the deposition of antimicrobial aerosols on the bronchial surfaces is characterized in preliminary tests without any animal experiments.


Assuntos
Pulmão/efeitos dos fármacos , Ácidos Sulfínicos/farmacologia , Aerossóis , Animais , Dissulfetos , Estudos de Viabilidade , Humanos , Pulmão/microbiologia , Ácidos Sulfínicos/química , Propriedades de Superfície
4.
Exp Ther Med ; 19(2): 1541-1549, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32010336

RESUMO

Allicin is a natural antibiotic produced by garlic as a defence against pathogens and pests. Due to the worldwide increase in antibiotic resistance, new antibiotics are desperately required. Allicin is such a candidate and is active against several multidrug-resistant (MDR) strains of human pathogens, including methicillin-resistant Staphylococcus aureus (MRSA). When administered orally, allicin is titrated out by glutathione in the cells and blood, and effective therapeutic concentrations are difficult to achieve at the site of an infection. However, in the case of lung infections, allicin can be delivered directly to pathogens via the pulmonary route. In this study, we designed and constructed an in vitro lung test rig, which allowed us to model accurately the exposure of lung air-passage surfaces to allicin and gentamicin, in order to examine the feasibility of combating lung infections by direct inhalation. A prototype test rig of lung bronchi with three bifurcations was constructed, which could be coated internally with a thin layer of bacteria-seeded agar medium. The deposition of antimicrobial aerosols on the modelled bronchial surfaces was followed in preliminary tests without the need for animal experiments. The differential sensitivity of the test bacteria to different antibiotics and the dose-dependency of inhibition was shown using the model. Furthermore, a synergistic effect of allicin vapour and ethanol in inhibiting bacterial growth was demonstrated. The modelling of the axial velocity air-flow distribution correlated with the regions indicating the inhibition of bacterial growth, demonstrating that the model has predictive value and can reduce the requirement for animal sacrifice in pre-clinical trials of novel antibiotics.

5.
Front Zool ; 4: 23, 2007 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-18031576

RESUMO

BACKGROUND: Owls are known for their silent flight. Even though there is some information available on the mechanisms that lead to a reduction of noise emission, neither the morphological basis, nor the biological mechanisms of the owl's silent flight are known. Therefore, we have initiated a systematic analysis of wing morphology in both a specialist, the barn owl, and a generalist, the pigeon. This report presents a comparison between the feathers of the barn owl and the pigeon and emphasise the specific characteristics of the owl's feathers on macroscopic and microscopic level. An understanding of the features and mechanisms underlying this silent flight might eventually be employed for aerodynamic purposes and lead to a new wing design in modern aircrafts. RESULTS: A variety of different feathers (six remiges and six coverts), taken from several specimen in either species, were investigated. Quantitative analysis of digital images and scanning electron microscopy were used for a morphometric characterisation. Although both species have comparable body weights, barn owl feathers were in general larger than pigeon feathers. For both species, the depth and the area of the outer vanes of the remiges were typically smaller than those of the inner vanes. This difference was more pronounced in the barn owl than in the pigeon. Owl feathers also had lesser radiates, longer pennula, and were more translucent than pigeon feathers. The two species achieved smooth edges and regular surfaces of the vanes by different construction principles: while the angles of attachment to the rachis and the length of the barbs was nearly constant for the barn owl, these parameters varied in the pigeon. We also present a quantitative description of several characteristic features of barn owl feathers, e.g., the serrations at the leading edge of the wing, the fringes at the edges of each feather, and the velvet-like dorsal surface. CONCLUSION: The quantitative description of the feathers and the specific structures of owl feathers can be used as a model for the construction of a biomimetic airplane wing or, in general, as a source for noise-reducing applications on any surfaces subjected to flow fields.

6.
Interface Focus ; 7(1): 20160078, 2017 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-28163870

RESUMO

Owls are an order of birds of prey that are known for the development of a silent flight. We review here the morphological adaptations of owls leading to silent flight and discuss also aerodynamic properties of owl wings. We start with early observations (until 2005), and then turn to recent advances. The large wings of these birds, resulting in low wing loading and a low aspect ratio, contribute to noise reduction by allowing slow flight. The serrations on the leading edge of the wing and the velvet-like surface have an effect on noise reduction and also lead to an improvement of aerodynamic performance. The fringes at the inner feather vanes reduce noise by gliding into the grooves at the lower wing surface that are formed by barb shafts. The fringed trailing edge of the wing has been shown to reduce trailing edge noise. These adaptations to silent flight have been an inspiration for biologists and engineers for the development of devices with reduced noise production. Today several biomimetic applications such as a serrated pantograph or a fringed ventilator are available. Finally, we discuss unresolved questions and possible future directions.

7.
Cardiovasc Eng Technol ; 6(3): 340-51, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26577365

RESUMO

Computational fluid dynamics (CFD) is used to simulate blood flow inside the fiber bundles of oxygenators. The results are interpreted in terms of flow distribution, e.g., stagnation and shunt areas. However, experimental measurements that provide such information on the local flow between the fibers are missing. A transparent model of an oxygenator was built to perform particle image velocimetry (PIV), to perform the experimental validation. The similitude theory was used to adjust the size of the PIV model to the minimal resolution of the PIV system used (scale factor 3.3). A standard flow of 80 mL/min was simulated with CFD for the real oxygenator and the equivalent flow of 711 mL/min, according to the similitude theory, was investigated with PIV. CFD predicts the global size of stagnation and shunt areas well, but underestimates the streamline length and changes in velocities due to the meandering flow around the real fibers in the PIV model. Symmetrical CFD simulation cannot consider asymmetries in the flow, due to manufacturing-related asymmetries in the fiber bundle. PIV could be useful for validation of CFD simulations; measurement quality however must be improved for a quantitative validation of CFD results and the investigation of flow effects such as tortuosity and anisotropic flow behavior.


Assuntos
Hemodinâmica , Hidrodinâmica , Oxigenadores de Membrana , Reologia/métodos , Simulação por Computador , Desenho de Equipamento , Modelos Cardiovasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA