Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37438144

RESUMO

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Angiografia , Insuficiência Cardíaca/diagnóstico por imagem , Estimativa de Kaplan-Meier , Rim/diagnóstico por imagem , Resultado do Tratamento
2.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38008428

RESUMO

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Modelos de Riscos Proporcionais , Cateterismo Cardíaco
3.
Heart Vessels ; 36(7): 1072-1079, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33484292

RESUMO

Preoperative frailty diminishes the potential for functional recovery after transcatheter aortic valve implantation (TAVI). However, perioperative changes in physical status and their impact on prognosis after TAVI have not previously been reported. Therefore, this study aimed to investigate whether perioperative changes in physical function affect prognosis in patients undergoing TAVI. We retrospectively reviewed 257 patients who underwent TAVI. The Short Physical Performance Battery (SPPB), an objective physical status assessment tool, was evaluated pre- and post-TAVI. Patients were divided into two groups: (i) patients whose SPPB score declined in the perioperative period (the decline group) and (ii) patients whose SPPB score did not decline in the perioperative period (the non-decline group). The primary endpoint was unplanned hospitalization owing to heart failure or cardiovascular death following TAVI. The mean follow-up period was 385 ± 151 days, mean age was 83.2 ± 5.8 years, and 67% of the patients were women. Sixteen patients required readmission owing to heart failure, and seven experienced cardiovascular-related death. Kaplan-Meier analysis revealed that the event-free rate was significantly lower in the decline group (log-rank, p = 0.006). A stepwise multivariate logistic regression analysis showed that a perioperative change in SPPB was significantly associated with primary endpoints (odds ratio, 1.51; 95% confidence interval, 1.12-2.04). Perioperative change in physical function was an independent risk factor for heart failure, hospitalization, or cardiovascular death following TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Exercício Físico/fisiologia , Fragilidade/fisiopatologia , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/epidemiologia , Feminino , Seguimentos , Fragilidade/epidemiologia , Fragilidade/etiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Readmissão do Paciente/tendências , Período Perioperatório , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
4.
Circ J ; 84(11): 2015-2022, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32999143

RESUMO

BACKGROUND: Asian patients have smaller aortic annuli. Although 20-mm balloon-expandable (BE) transcatheter heart valves (THV) are manufactured for transcatheter aortic valve implantation (TAVI) in these cases, the supra-annular design of self-expandable (SE) THV is considered more suitable; however, real-world comparative data are scarce.Methods and Results:Consecutive TAVI cases (n=330) in a single Japanese center were reviewed. Based on the cutoff for the new-generation 20-/23-mm BE-THV, a small aortic annulus was defined as <330 mm2. A considerable number of patients had small annuli: 49/302 (16%). Of these, 33 BE-THV and 13 SE-THV using new-generation valves were compared. Although the SE-THV group had smaller annulus area (median 297 (interquartile range, 280-313) vs. 309 (303-323) mm2(P=0.022)), it had more favorable post-procedural parameters; for SE-THV and BE-THV, respectively, effective orifice area (EOA), 1.5 (1.3-1.6) vs. 1.1 cm2(0.9-1.3) (P=0.002); mean pressure gradient, 7.6 (5.6-11.0) vs. 14.2 mmHg (11.2-18.8) (P=0.001); and peak velocity, 1.8 (1.6-2.4) vs. 2.7 m/s (2.3-3.1) (P=0.001). Although new left bundle branch block was higher with SE-THV (24% and 62%, P=0.02), patient-prosthesis mismatch (PPM) ≥ moderate (indexed EOA <0.85 cm2/m2) was significantly less with SE-THV than with BE-THV (8% vs. 55%; P=0.04). Hemodynamic findings were consistent up to 1 year. CONCLUSIONS: Small annuli are often seen in Asian patients, for whom SE-THV implantation results in favorable hemodynamics with less PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Resultado do Tratamento
5.
Circ J ; 84(12): 2296-2301, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33055458

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for symptomatic patients with severe aortic stenosis (AS). Sometimes patients with severe AS taking immunosuppressants are encountered. The effect of immunosuppressive therapy on clinical outcomes in patients with AS following TAVI were investigated.Methods and Results:In total, 282 consecutive patients with severe AS who underwent transfemoral TAVI from January 2016 to December 2018 at St. Marianna University School of Medicine were reviewed. They were divided into 2 groups: the immunosuppressants group (IM group) in which patients continually used immunosuppressive drugs (n=22) and the non-immunosuppressants group (non-IM group) (n=260). The composite endpoints of a major adverse cardiovascular and cerebrovascular event (MACCE) defined as non-lethal myocardial infarction, unstable angina pectoris, heart failure requiring hospitalization, stroke, and cardiovascular death were evaluated. There were no differences in the incidence of vascular access complications (32% vs. 20%, P=0.143) and the rate of procedure success (100% vs. 93%, P=0.377) between the IM and non-IM groups. During the median follow-up period of 567 (16-1,312) days after the TAVI procedure, there were no significant differences between the IM and non-IM groups in the incidence of infectious complications (14% vs. 9%, P=0.442) or MACCE (18% vs. 20%, respectively; P=0.845). CONCLUSIONS: The use of IM after TAVI is not associated with increased vascular access complications or mid-term MACCE in patients with severe AS treated with TAVI.


Assuntos
Estenose da Valva Aórtica , Imunossupressores , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Terapia de Imunossupressão , Imunossupressores/efeitos adversos , Fatores de Risco , Resultado do Tratamento
6.
Circ J ; 84(6): 1012-1019, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32224577

RESUMO

BACKGROUND: Although left bundle-branch block (LBBB) is a known conduction disorder that occurs after transcatheter aortic valve implantation (TAVI), its clinical impact in the Japanese population remains unclear.Methods and Results:Of the 298 consecutive patients who underwent TAVI from January 2016 to December 2018 in a high-volume center in Japan, 68 with prior or periprocedural permanent pacemaker implantation (PPI), pre-existing LBBB, death during hospitalization, aborted procedure, or incomplete data were excluded. Among the final cohort of 230 patients, new-onset LBBB occurred in 90 (39%) after TAVI and persisted at 1-month follow up in 29 patients (13%; persistent new-onset LBBB, PN-LBBB). On multivariable analysis, self-expandable valve (SEV) use was found to be the only predictor of PN-LBBB (odds ratio: 4.39, 95% confidence interval: 1.69-11.41, P=0.002). There were no differences between patients with and without PN-LBBB in terms of overall mortality (18.8% vs. 26.0%, log-rank P=0.90) or need for late PPI (4.0% vs. 3.5%, log-rank P=0.74), yet there was an increased re-admission rate for heart failure (HF) in the PN-LBBB group (15.6% vs. 8.0%, log-rank P=0.046) at a median follow up of 431 (interquartile range, 271-733) days. CONCLUSIONS: PN-LBBB following TAVI was not associated with mortality or late PPI, but with a higher incidence of HF-related re-hospitalization at the mid-term follow up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/epidemiologia , Hospitais com Alto Volume de Atendimentos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Readmissão do Paciente , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37500393

RESUMO

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Estudos de Viabilidade , Meios de Contraste/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
8.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37938532

RESUMO

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia sob Estresse , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
9.
Am J Cardiol ; 210: 259-265, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37875233

RESUMO

Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Prevalência , Fatores de Risco , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos
11.
Cardiovasc Revasc Med ; 59: 60-66, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37612169

RESUMO

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Assuntos
Cardiologistas , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Isquemia , Valor Preditivo dos Testes , Índice de Gravidade de Doença
12.
J Cardiovasc Magn Reson ; 15: 106, 2013 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-24359564

RESUMO

BACKGROUND: Long-term intake of long-chain n-3 polyunsaturated fatty acids (n-3 PUFAs), especially eicosapentaenoic acid (EPA) is associated with a low risk for cardiovascular disease. Phase-contrast cine cardiovascular magnetic resonance (PC cine CMR) can assess coronary flow reserve (CFR). The present study investigates the relationship between CFR evaluated by PC cine CMR and the serum EPA. METHODS: We studied 127 patients (male, 116 (91%); mean age, 72.2 ± 7.4 years) with known or suspected coronary artery disease (CAD). X-ray coronary angiography revealed no significant coronary arterial stenoses (defined as luminal diameter reduction ≥ 50% on quantitative coronary angiogram (QCA) analysis) in all study participants. Breath-hold PC cine CMR images of the coronary sinus (CS) were acquired to assess blood flow of the CS both at rest and during adenosine triphosphate (ATP) infusion. We calculated CFR as CS blood flow during ATP infusion divided by that at rest. Patients were allocated to groups according to whether they had high (n = 64, EPA ≥ 75.8 µg/mL) or low (n = 63, EPA < 75.8 µg/mL) median serum EPA. RESULTS: CFR was significantly lower in the low, than in the high EPA group (2.54 ± 1.00 vs. 2.91 ± 0.98, p = 0.038). Serum EPA positively correlated with CFR (R = 0.35, p < 0.001). We defined preserved CFR as > 2.5, which is the previously reported lower limit of normal flow reserve without obstructive CAD. Multivariate analysis revealed that EPA is an independent predictor of CFR > 2.5 (odds ratio, 1.01; 95% confidence interval, 1.00 - 1.02, p = 0.008). CONCLUSIONS: The serum EPA is significantly correlated with CFR in CAD patients without significant coronary artery stenosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Ácido Eicosapentaenoico/sangue , Reserva Fracionada de Fluxo Miocárdico , Imagem Cinética por Ressonância Magnética , Trifosfato de Adenosina , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Suspensão da Respiração , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Função Ventricular Esquerda
14.
JMIR Rehabil Assist Technol ; 10: e45247, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37195764

RESUMO

BACKGROUND: No consensus exists on the efficacy of home-based cardiac rehabilitation (CR) in patients who have undergone transcatheter aortic valve implantation (TAVI). Additionally, there are no reports on home-based cardiac telemonitoring rehabilitation (HBTR) in patients after TAVI. OBJECTIVE: We aimed to investigate the efficacy of HBTR in patients who have undergone TAVI. METHODS: This single-center preliminary study introduced HBTR to patients after TAVI, and the efficacy outcomes of the rehabilitation method were compared to that of a historical control cohort. The historical control cohort (control group) consisted of 6 consecutive patients who underwent ordinary outpatient CR after TAVI from February 2016 to March 2020. Patients who participated in the HBTR program were only recruited after the TAVI procedure and before discharge between April 2021 and May 2022. In the first 2 weeks after TAVI, patients underwent outpatient CR and were trained using telemonitoring rehabilitation systems. Thereafter, patients underwent HBTR twice a week for 12 weeks. The control group performed standard outpatient CR at least once a week for 12 to 16 weeks. Efficacy was assessed using peak oxygen uptake (VO2) prior to and after CR. RESULTS: Eleven patients were included in the HBTR group. All patients underwent 24 HBTR sessions during the 12-week training period, and no adverse events were observed. The control group participants performed 19 (SD 7) sessions during the training period, and no adverse events were observed. Participants in the HBTR and control groups had a mean age of 80.4 (SD 6.0) years and 79.0 (SD 3.9) years, respectively. In the HBTR group, preintervention and postintervention peak VO2 values were 12.0 (SD 1.7) mL/min/kg and 14.3 (SD 2.7) mL/min/kg (P=.03), respectively. The peak VO2 changes in the HBTR and control groups were 2.4 (SD 1.4) mL/min/kg and 1.3 (SD 5.0) mL/min/kg (P=.64), respectively. CONCLUSIONS: Home-based CR using a telemonitoring system is a safe outpatient rehabilitation method. Its efficacy is not inferior to that of standard CR in patients who have undergone TAVI. TRIAL REGISTRATION: Japan Registry of Clinical Trials jRCTs032200122; https://jrct.niph.go.jp/latest-detail/jRCTs032200122.

15.
Am J Cardiol ; 204: 130-139, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37541149

RESUMO

Electrocardiogram (ECG) left ventricular hypertrophy (LVH) is associated with the prognosis of patients with aortic stenosis. However, the impact of the presence or absence of ECG-LVH on the clinical outcomes after transcatheter aortic valve implantation (TAVI) is limited. This study aimed to assess the prognostic value of ECG-LVH among patients with aortic stenosis treated by TAVI. A total of 1,667 patients who underwent TAVI were prospectively enrolled into the OCEAN-TAVI (Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation) registry. A total of 1,446 patients (mean age 84 years; 29.9% men) were analyzed. The Sokolow-Lyon index was used to determine the presence of ECG-LVH. LVH was also assessed using transthoracic echocardiography (TTE). We investigated the association between ECG-LVH and all-cause and cardiovascular mortality. This study identified ECG-LVH and TTE-LVH in 743 (51.5%) and 1,242 patients (86.0%), respectively. The Kaplan-Meier analysis revealed that all-cause mortality was significantly higher among patients without ECG-LVH than among those with ECG-LVH (log-rank p <0.001). In the multivariable analysis, the absence of ECG-LVH was independently associated with all-cause mortality (hazard ratio 1.98, 95% confidence interval 1.39 to 2.82, p <0.001), regardless of the presence or absence of TTE-LVH. Furthermore, the presence of TTE-LVH with the absence of ECG-LVH was observed in 575 patients (40%), which was associated with cardiovascular mortality (hazard ratio 2.84, 95% confidence interval 1.56 to 5.17, p <0.001). In conclusion, the absence of ECG-LVH was independently associated with an increased risk of all-cause mortality after TAVI. Risk stratification using both ECG-LVH and TTE-LVH is a useful predictor of adverse clinical outcomes after TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Prognóstico , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/epidemiologia , Hipertrofia Ventricular Esquerda/etiologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Sistema de Registros , Valva Aórtica/cirurgia , Resultado do Tratamento
16.
Circ Rep ; 5(12): 442-449, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38073869

RESUMO

Background: A high score for controlling nutritional status (CONUT) due to poor nutritional status has been associated with adverse outcomes in patients with chronic heart failure. However, because little is known about the effect of CONUT score on mortality rates after transcatheter mitral valve repair, we evaluated nutrition screening tools for prognosis prediction in patients undergoing transcatheter mitral valve repair using the MitraClipTM system. Methods and Results: We retrospectively analyzed 148 patients with severe mitral regurgitation (MR) who underwent MitraClipTM implantation between April 2018 and April 2021. The preprocedural CONUT scores were assessed at the time of hospitalization, the primary outcome was all-cause death, and the analysis was of the mortality and incidence rates of cardiac events 1 year post-operation. Functional MR was of ischemic origin in the majority of patients (69.6%), with a mean left ventricular ejection fraction of 48.9±15.8%. Kaplan-Meier curves indicated that all-cause death was significantly worse in the high-CONUT score group than in the low-CONUT score group. Cox hazard analysis showed a significant association between all-cause death and CONUT score, as well as MitraScore. Conclusions: Preprocedural CONUT score, as well as MitraScore, in patients undergoing transcatheter edge-to-edge mitral valve repair may predict an increased risk of all-cause death. This knowledge should allow the heart team to accurately assess the clinical implications and prognostic benefits of the procedure in individual patients.

17.
Circ Rep ; 5(9): 358-364, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37693232

RESUMO

Background: Very severe aortic stenosis (AS) has a poor prognosis even in asymptomatic patients, and asymptomatic very severe AS is a Class IIa indication for aortic valve replacement, although the safety and effectiveness of transcatheter aortic valve implantation (TAVI) for very severe AS is not well-established. Methods and Results: This study included 366 patients undergoing TAVI at a single center, with 85 and 281 patients in the very severe AS (peak velocity ≥5 m/s or mean pressure gradient (PG) ≥60 mmHg) and severe AS groups, respectively. Procedural and clinical outcomes at 1-year follow-up were compared between groups. The calcium scores were significantly higher in the very severe AS group (2,864.5 vs. 1,405.8 arbitrary units [AU] (P<0.001). Although the patient-prosthesis mismatch rate was higher in the very severe AS group (38.3% vs. 25.7%; P=0.029), there was no significant difference in the early safety and clinical efficacy between the groups (16.5% vs. 17.1% and 12.0% vs. 18.9%, respectively). Similarly, there was no significant difference in all-cause mortality at 1 year (4.8% vs. 9.8%). Conclusions: Despite a higher incidence of prosthesis-patient mismatch in those with very severe AS, the procedural and clinical outcomes were comparable to those in patients with severe AS. TAVI may be a reasonable treatment option for very severe AS.

18.
J Am Heart Assoc ; 10(18): e019282, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34533044

RESUMO

Background Current guidelines recommend at least 6 months of antithrombotic therapy and antibiotic prophylaxis after septal-occluding device deployment in transcatheter closure of atrial septal defect. It has been estimated that it takes ≈6 months for complete neo-endothelialization; however, neo-endothelialization has not previously been assessed in vivo in humans. Methods and Results The neointimal coverage of septal occluder devices was evaluated 6 months after implantation in 15 patients by angioscopy from the right atrium. Each occluder surface was divided into 9 areas; the levels of endothelialization in each area were semiquantitatively assessed by 4-point grades. Device neo-endothelialization was sufficient in two thirds of patients, but insufficient in one third. In the comparison between patients with sufficiently endothelialized devices of average grade score ≥2 (good endothelialization group, n=10) and those with poorly endothelialized devices of average grade score <2 (poor endothelialization group, n=5), those in the poor endothelialization group had larger devices deployed (27.0 mm [25.0-31.5 mm] versus 17.0 mm [15.6-22.5 mm], respectively) and progressive right heart dilatation. The endothelialization was poorer around the central areas. Moreover, the prevalence of thrombus formation on the devices was higher in the poorly endothelialized areas than in the sufficiently endothelialized areas (Grade 0, 94.1%; Grade 1, 63.2%; Grade 2, 0%; Grade 3, 1.6%). Conclusions Neo-endothelialization on the closure devices varied 6 months after implantation. Notably, poor endothelialization and thrombus attachment were observed around the central areas and on the larger devices.


Assuntos
Angioscopia , Comunicação Interatrial , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos
19.
Clin Cardiol ; 44(8): 1089-1097, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34033124

RESUMO

BACKGROUND: A high frequency of coronary artery disease (CAD) is reported in patients with severe aortic valve stenosis (AS) who undergo transcatheter aortic valve implantation (TAVI). However, the optimal management of CAD in these patients remains unknown. HYPOTHESIS: We hypothesis that AS patients with TAVI complicated by CAD have poor prognosis. His study evaluates the prognoses of patients with CAD and severe AS after TAVI. METHODS: We divided 186 patients with severe AS undergoing TAVI into three groups: those with CAD involving the left main coronary (LM) or proximal left anterior descending artery (LAD) lesion (the CAD[LADp] group), those with CAD not involving the LM or a LAD proximal lesion (the CAD[non-LADp] group), and those without CAD (Non-CAD group). Clinical outcomes were compared among the three groups. RESULTS: The CAD[LADp] group showed a higher incidence of major adverse cardiovascular and cerebrovascular events (MACCEs) and all-cause mortality than the other two groups (log-rank p = .001 and p = .008, respectively). Even after adjustment for STS score and percutaneous coronary intervention (PCI) before TAVI, CAD[LADp] remained associated with MACCE and all-cause mortality. However, PCI for an LM or LAD proximal lesion pre-TAVI did not reduce the risk of these outcomes. CONCLUSIONS: CAD with an LM or LAD proximal lesion is a strong independent predictor of mid-term MACCEs and all-cause mortality in patients with severe AS treated with TAVI. PCI before TAVI did not influence the outcomes.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
BMJ Case Rep ; 13(12)2020 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-33376091

RESUMO

Transcatheter aortic valve implantation (TAVI) is a rapidly evolving treatment option with an inherent risk of causing cerebral infarctions. The mechanism of cerebral infarction during TAVI mainly involves embolisms from the aortic wall and valve. Transoesophageal echocardiography (TEE) is useful for detecting aortic atheromas. We present the case of a patient in whom the dispersal of aortic atheromas was monitored by TEE during TAVI. This report demonstrates the importance of preoperatively predicting embolisms from aortic atheromas in patients with severe aortic stenosis.


Assuntos
Aorta/diagnóstico por imagem , Estenose da Valva Aórtica , Aterosclerose , Infarto Cerebral , Ecocardiografia Transesofagiana/métodos , Complicações Intraoperatórias/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Aterosclerose/complicações , Aterosclerose/diagnóstico , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/etiologia , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Monitorização Intraoperatória/métodos , Cuidados Pré-Operatórios/métodos , Risco Ajustado , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA