Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 2402, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510181

RESUMO

The COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/µl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , Técnicas de Laboratório Clínico/métodos , Técnicas e Procedimentos Diagnósticos , Testes Diagnósticos de Rotina , Humanos , Limite de Detecção , Testes Imediatos , RNA Viral/genética , Transcrição Reversa , SARS-CoV-2/química , SARS-CoV-2/metabolismo , Sensibilidade e Especificidade
2.
Sci Rep ; 11(1): 5448, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750853

RESUMO

To safely re-open economies and prevent future outbreaks, rapid, frequent, point-of-need, SARS-CoV-2 diagnostic testing is necessary. However, existing field-deployable COVID-19 testing methods require the use of uncomfortable swabs and trained providers in PPE, while saliva-based methods must be transported to high complexity laboratories for testing. Here, we report the development and clinical validation of High-Performance Loop-mediated isothermal Amplification (HP-LAMP), a rapid, saliva-based, SARS-CoV-2 test with a limit of detection of 1.4 copies of virus per µl of saliva and a sensitivity and specificity with clinical samples of > 96%, on par with traditional RT-PCR based methods using swabs, but can deliver results using only a single fluid transfer step and simple heat block. Testing of 120 patient samples in 40 pools comprised of 5 patient samples each with either all negative or a single positive patient sample was 100% accurate. Thus, HP-LAMP may enable rapid and accurate results in the field using saliva, without need of a high-complexity laboratory.


Assuntos
COVID-19/diagnóstico , SARS-CoV-2/genética , Saliva/virologia , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19 , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular , Nasofaringe/virologia , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/metabolismo , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Temperatura
3.
medRxiv ; 2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-32577685

RESUMO

The COVID-19 pandemic has resulted in an urgent global need for rapid, point-of-care diagnostic testing. Existing methods for nucleic acid amplification testing (NAAT) require an RNA extraction step prior to amplification of the viral RNA. This step necessitates the use of a centralized laboratory or complex and costly proprietary cartridges and equipment, and thereby prevents low-cost, scalable, point-of-care testing. We report the development of a highly sensitive and robust, easy-to-implement, SARS-CoV-2 test that utilizes isothermal amplification and can be run directly on viral transport media following a nasopharyngeal swab without the need for prior RNA extraction. Our assay provides visual results in 30 min with 85% sensitivity, 100% specificity, and a limit of detection (LoD) of 2.5 copies/µl, and can be run using a simple heat block.

4.
medRxiv ; 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32587984

RESUMO

Rapid, scalable, point-of-need, COVID-19 diagnostic testing is necessary to safely re-open economies and prevent future outbreaks. We developed an assay that detects single copies of SARS-CoV-2 virus directly from saliva and swab samples in 30 min using a simple, one-step protocol that utilizes only a heat block and microcentrifuge tube prefilled with a mixture containing the necessary reagents and has a sensitivity and specificity of 97% and 100%, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA