Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Orthop ; 95: 415-424, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023429

RESUMO

BACKGROUND AND PURPOSE: The primary aim of this systematic review and meta-analysis was to evaluate the success rate of 3 different epiphysiodesis techniques with implant usage for the treatment of leg-length discrepancy (LLD) in the pediatric population. The secondary aim was to address effectiveness (final LLD) and the reported complications of staples, tension-band plates (TBP), and percutaneous epiphysiodesis screws (PETS). METHODS: In this systematic review we searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with epiphysiodesis with an implant. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre-/postoperatively, successful/unsuccessful) and complications that were graded on severity. RESULTS: 44 studies (2,184 patients) were included. 455 underwent epiphysiodesis with PETS, 578 patients with TBP, and 1,048 with staples. Successful epiphysiodesis was reported in 76% (95% confidence interval [CI] 61-89) with PETS (9 studies), 67% (CI 54-79) with TBP (10 studies), and 51% (CI 28-65) with Blount staples (8 studies). From pooled analysis, the severe complications rate was 7% for PETS, 17% for TBP, and 16% for Blount staples. Angular deformity was reported in 4% after PETS, 10% after TBP, and 17% after Blount staples. CONCLUSION: Our results showed that epiphysiodesis with PETS implants was the most successful technique. PETS had a higher success rate, fewer severe complications, and a lower proportion with angular deformity.


Assuntos
Placas Ósseas , Parafusos Ósseos , Epífises , Desigualdade de Membros Inferiores , Humanos , Desigualdade de Membros Inferiores/cirurgia , Epífises/cirurgia , Criança , Resultado do Tratamento , Suturas , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação
2.
Acta Orthop ; 95: 225-232, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757681

RESUMO

BACKGROUND AND PURPOSE: Post-discharge inquiries to the hospital are predominantly conducted through phone calls. The rigid timing of these calls is inconvenient for patients and disrupts the workflows of healthcare professionals. The aim of this study was to investigate the effect of a team-based digital communication intervention (eDialogue) facilitated through a messenger-like commercial solution on patient-initiated phone calls to the hospital after discharge. Secondarily, we investigated other patient-initiated contacts, patients' perception of continuity of care, and their perception of feeling safe and satisfied after hospital discharge. METHODS: On the day of discharge, 70 surgically treated orthopedic patients were randomized to the intervention group with access to eDialogue (n = 35) or the control group with standard communication pathways by phone call (n = 35) for the following 8 weeks. Through eDialogue, the intervention group had access to team-based asynchronous digital communication in text and photos with healthcare professionals across disciplines and sectors. Inclusion criteria were discharge to own home and receipt of rehabilitation services from both hospital and primary care after discharge. RESULTS: We found a significant reduction in the mean number of patient-initiated phone calls to the hospital from 2.3 (95% confidence interval [CI] 1.4-4.1) in the control group to 0.5 (CI 0.3-1.0) in the intervention group (P = 0.004). Across groups, patients reported similar perceptions of continuity of care; however, the participants in the intervention group expressed significantly improved perceptions of, and satisfaction with, access to healthcare after discharge. CONCLUSION: Access to eDialogue reduced patient-initiated phone calls to the hospital, enhanced patient satisfaction with healthcare accessibility, and did not compromise patients' perception of continuity of care after discharge compared with standard communication pathways.


Assuntos
Continuidade da Assistência ao Paciente , Procedimentos Ortopédicos , Alta do Paciente , Satisfação do Paciente , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/métodos , Idoso , Telefone , Adulto , Equipe de Assistência ao Paciente , Comunicação
3.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36904954

RESUMO

Determining the presence and severity of knee osteoarthritis (OA) is a valuable application of inertial measurement units (IMUs) in the remote monitoring of patients. This study aimed to employ the Fourier representation of IMU signals to differentiate between individuals with and without knee OA. We included 27 patients with unilateral knee osteoarthritis (15 females) and 18 healthy controls (11 females). Gait acceleration signals were recorded during overground walking. We obtained the frequency features of the signals using the Fourier transform. The logistic LASSO regression was employed on the frequency domain features as well as the participant's age, sex, and BMI to distinguish between the acceleration data from individuals with and without knee OA. The model's accuracy was estimated by 10-fold cross-validation. The frequency contents of the signals were different between the two groups. The average accuracy of the classification model using the frequency features was 0.91 ± 0.01. The distribution of the selected features in the final model differed between patients with different severity of knee OA. In this study, we demonstrated that using logistic LASSO regression on the Fourier representation of acceleration signals can accurately determine the presence of knee OA.


Assuntos
Osteoartrite do Joelho , Feminino , Humanos , Articulação do Joelho , Marcha , Caminhada , Aceleração , Fenômenos Biomecânicos
4.
Acta Orthop ; 94: 51-59, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36807707

RESUMO

BACKGROUND AND PURPOSE: Intramedullary bone-lengthening nails have become increasingly popular. The 2 most used and successful nails are the FITBONE and the PRECICE nails. Uniform reporting is lacking on complications of intramedullary bone-lengthening nails. The purpose was therefore to assess and categorize the complications of lower limb bone-lengthening nails and investigate risk factors. PATIENTS AND METHODS: We performed a retrospective review of patients operated on with intramedullary lengthening nails at 2 hospitals. We included only lower limb lengthening with FITBONE and PRECICE nails. Recorded patient data was patient demographics, nail information, and any complication. Complications were graded according to severity and origin classification. Complication risk factors were assessed with modified Poisson regression. RESULTS: 314 segments in 257 patients were included. The FITBONE nail was predominantly used (75%), and most of the lengthenings were performed in the femur (80%). 53% of the patients had complications. 269 complications were identified in 175 segments (144 patients). Device-related complications were most frequent (0.3 complications/segment), followed by joint complications (0.2 complications/segment). An increased relative risk was found for complications in the tibia compared with the femur and for age groups above 30 years compared with the 10-19 years group. CONCLUSION: Complications with intramedullary bone lengthening nails were more frequent than has previously been reported, with 53% of patients sustaining a complication. Future studies need to document the complications meticulously so that the true risk can be established.


Assuntos
Alongamento Ósseo , Fixação Intramedular de Fraturas , Humanos , Adulto , Fixação Intramedular de Fraturas/efeitos adversos , Desigualdade de Membros Inferiores/cirurgia , Estudos de Coortes , Unhas , Pinos Ortopédicos , Fêmur/cirurgia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento
5.
Acta Orthop ; 94: 594-599, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093629

RESUMO

BACKGROUND AND PURPOSE: There is inconsistency in the literature regarding the relationship between increased birthweight and risk of developmental dysplasia of the hip (DDH). We aimed to investigate the correlation between birthweight and pubo-femoral distance (PFD), as well as Graf's α angle in newborns undergoing hip ultrasound examination at 6 weeks of age. PATIENTS AND METHODS: Basic newborn characteristics and ultrasound measurements were retrospectively collected during a 1-year study period. We excluded multiple births, newborns born at less than 37 gestational weeks, and incomplete information. Simple and multiple linear regression analyses were performed to evaluate the correlation of birthweight and PFD, and, second, birthweight and α angles including a stratified regression analysis investigating the potential effect modification of sex. RESULTS: 707 newborns (1,414 hips) were included. Mean birthweight was significantly higher for male newborns (P < 0.001). Increased birthweight was positively correlated to PFD values (crude coefficient 0.21, 95% confidence interval [CI] 0.10-0.32) and the correlation was still present after adjusting for sex, family history, and breech presentation (adjusted coefficient 0.18, CI 0.07-0.29). The stratified α angle model for the males was significant for both the crude coefficient (-0.73, CI -1.28 to -0.19) and the adjusted (-0.59, CI -1.15 to -0.03), and also for the females (crude coefficient -1.14, CI -1.98 to -0.31 and adjusted coefficient -1.15, CI -1.99 to -0.31). CONCLUSION: We found that increased birthweight positively correlated to PFD, and negatively correlated to α angle, but this was not of clinical significance.


Assuntos
Luxação Congênita de Quadril , Gravidez , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/epidemiologia , Peso ao Nascer , Fêmur/diagnóstico por imagem , Exame Físico , Ultrassonografia
6.
Sensors (Basel) ; 22(14)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35890969

RESUMO

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.


Assuntos
Osteoartrite do Joelho , Aceleração , Acelerometria , Idoso , Fenômenos Biomecânicos , Marcha , Humanos , Reprodutibilidade dos Testes , Caminhada
7.
Acta Paediatr ; 110(8): 2430-2434, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33914971

RESUMO

AIM: To establish the positive predictive value (PPV) of clinical hip examinations performed by referrers in the Danish screening programme for Developmental Dysplasia of the Hip (DDH) utilising three definitions of true positive DDH diagnosis. METHODS: We retrospectively identified 290 children (169 female) referred during a 4-year period to the orthopaedic outpatient clinic at our institution with a positive clinical hip examination. Positive predictive value was calculated for clinical hip examinations across three definitions of a true positive clinical hip examination for all referrers and subgroups consisting of general practitioners, midwives and paediatricians. The PPV for clinical hip examinations was calculated for paediatric orthopaedic surgeons using one of the three definitions. RESULTS: Positive predictive value of clinical hip examinations for all referrers were 5.4%, 3.6% and 1.8% with the definition of a true positive DDH diagnosis defined as clinical instability found by orthopaedic surgeon, ultrasound classification ≥Graf IIc or both definitions combined, respectively. Positive predictive value of clinical hip examinations performed by orthopaedic surgeons was 33.3% with a true positive clinical examination defined as an ultrasound classification ≥Graf IIc. CONCLUSION: We conclude that the positive predictive value of clinical hip examinations made by referrers in the Danish screening programme for DDH is low.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Criança , Feminino , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/epidemiologia , Humanos , Lactente , Recém-Nascido , Triagem Neonatal , Valor Preditivo dos Testes , Estudos Retrospectivos , Ultrassonografia
8.
Acta Orthop ; 92(4): 485-492, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34074206

RESUMO

Background and purpose - Since the introduction of intramedullary bone transport nails only very few cases have been reported in the literature. Thus we evaluated the results and complications in a single institution retrospective cohort.Patients and methods - 15 (median age 40 years (18-70), 8 males) consecutive patients, were included and the electronic patient records and radiographs were reviewed. Complications were severity graded and categorized as device or non-device related.Results - The segmental bone loss was due to non-union site in 8 femurs and 4 tibias, or traumatic bone loss in 2 femurs and 1 tibia. The segmental bone defect was a median of 3 cm (0.5-10). 9 of 10 femoral cases and 4 of 5 tibial cases healed with the bone transport nail. All 15 patients had a healed docking site and regenerate at the end of treatment after a median of 13 months (6-38). 24 complications (15 device related and 9 non-device related) occurred in 11/15 patients with a minimum follow-up of 6 months after nail removal. The number of unplanned surgeries due to device related complications was: 0 in 9 patients, 1 in 3 patients, 2 in 1 patient, 3 in 2 patients.Interpretation - Segmental bone defects can heal with a bone transport nail. However, the number of complications was high and 15 out of 24 complications were devicerelated. Optimizing nail design is therefore needed to reduce complications in intramedullary bone transport.


Assuntos
Alongamento Ósseo/métodos , Pinos Ortopédicos , Transplante Ósseo/métodos , Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Complicações Pós-Operatórias/etiologia , Tíbia/cirurgia , Adolescente , Adulto , Idoso , Estudos de Coortes , Desenho de Equipamento , Feminino , Fêmur/lesões , Consolidação da Fratura/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/lesões , Adulto Jovem
9.
Acta Orthop ; 92(1): 120-127, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33106069

RESUMO

Background and purpose - In recent years motorized intramedullary lengthening nails have become increasingly popular. Complications are heterogeneously reported in small case series and therefore we made a systematic review of complications occurring in lower limb lengthening with externally controlled motorized intramedullary bone lengthening nails.Methods - We performed a systematic search in PubMed, EMBASE, and the Cochrane Library with medical subject headings: Bone Nails, Bone Lengthening, and PRECICE and FITBONE nails. Complications were graded on severity and origin.Results - The search identified 952 articles; 116 were full text screened, and 41 were included in the final analysis. 983 segments were lengthened in 782 patients (age 8-74 years). The distribution of nails was: 214 FITBONE, 747 PRECICE, 22 either FITBONE or PRECICE. Indications for lengthening were: 208 congenital shortening, 305 acquired limb shortening, 111 short stature, 158 with unidentified etiology. We identified 332 complications (34% of segments): Type I (minimal intervention) in 11% of segments; Type II (substantial change in treatment plan) in 15% of segments; Type IIIA (failure to achieve goal) in 5% of segments; and Type IIIB (new pathology or permanent sequelae) in 3% of segments. Device and bone complications were the most frequent.Interpretation - The overall risk of complications was 1 complication for every 3 segments lengthened. In 1 of every 4 segments, complications had a major impact leading to substantial change in treatment, failure to achieve lengthening goal, introduction of a new pathology, or permanent sequelae. However, as no standardized reporting method for complications exists, the true complication rates might be different.


Assuntos
Alongamento Ósseo/métodos , Pinos Ortopédicos , Fêmur/cirurgia , Complicações Pós-Operatórias/etiologia , Tíbia/cirurgia , Alongamento Ósseo/instrumentação , Humanos
10.
Acta Orthop ; 92(4): 479-484, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33757381

RESUMO

Background and purpose - Observing serious adverse events during treatment with the Precice Stryde bone lengthening nail (NuVasive, San Diego, CA, USA), we conducted a nationwide cross-sectional study to report the prevalence of adverse events from all 30 bone segments in 27 patients treated in Denmark.Patients and methods - Radiographs of all bone segments were evaluated regarding radiographic changes in February 2021. We determined the number of bone segments with late onset of pain and/or radiographically confirmed osteolysis, periosteal reaction, or cortical hypertrophy in the junctional area of the nail.Results - In 30 bone segments of 27 patients we observed radiographic changes in 21/30 segments of 20/27 patients, i.e., 19/30 osteolysis, 12/30 periosteal reaction (most often multi-layered), and 12/30 cortical hypertrophy in the area of the junction between the telescoping nail parts. Late onset of pain was a prominent feature in 8 patients. This is likely to be a prodrome to the bony changes. Discoloration (potential corrosion) at the nail interface was observed in multiple removed nails. 15/30 nails were still at risk of developing complications, i.e., were not yet removed.Interpretation - All Stryde nails should be monitored at regular intervals until removal. Onset of pain at late stages of limb lengthening, i.e., consolidation of the regenerate, should warrant immediate radiographic examination regarding osteolysis, periosteal reaction, and cortical hypertrophy, which may be associated with discoloration (potential corrosion) of the nail. We recommend removal of Stryde implants as early as possible after consolidation of the regenerate.


Assuntos
Alongamento Ósseo/instrumentação , Pinos Ortopédicos , Osteólise/etiologia , Dor Pós-Operatória/etiologia , Periósteo/patologia , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Dinamarca , Fêmur/cirurgia , Humanos , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Dor Pós-Operatória/diagnóstico por imagem , Periósteo/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Tíbia/cirurgia , Adulto Jovem
11.
Acta Orthop ; 92(5): 621-627, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34102950

RESUMO

Background and purpose - We noted several adverse events in patients in whom the first version of the STRYDE limb-lengthening nail (NuVasive Specialized Orthopaedics, San Diego, CA) had been implanted. Pain, osteolysis, periosteal reactions, and cortical hypertrophy at the nail junction were noted. Here, we present the analysis of 23 retrieved STRYDE implants.Materials and methods - We undertook visual inspection of the retrieved nails and screws, mechanical evaluation of the junction, micro-CT analyses, microscopic inspection of the bushing, screws, screw holes, and separated parts of the implants. Positive material identification (PMI) and energy-dispersive X-ray spectroscopy (EDS) were used to analyze the chemical composition. The hardness of the material was also investigated.Results - 20/23 retrieved nails had visible signs of corrosion, i.e., discoloration at the telescopic junction. Micro-CT verified corrosion attacks in 12/12 scanned bushings. Corrosion, predominantly mechanically assisted crevice corrosion, was observed at the locking screws and screw holes in 20/23 nails. Biological material inside the nail was observed in addition to oozing from the junction of 2 nails during hardware removal, which was experimentally reproducible. Notably, the mechanical construction of the bushing changed from PRECICE P2 to STRYDE nails.Interpretation - STRYDE nails are not hermetically sealed, and liquid can pass the bushing. Biodur 108 itself is corrosion resistant; however, mechanically assisted crevice corrosion of the bushing, locking screws, and screw holes may be aggravated due to manufacturing aiming for increased strength and hardness of the alloy.Observing several adverse events, we recently published a nationwide cross-sectional analysis of all 30 STRYDE limb- lengthening nails (NuVasive, Specialized Orthopedics, San Diego, CA) that were implanted in Denmark (Rölfing et al. 2021a). 27/30 STRYDE nails have now been removed and we present data from metallurgical analysis of 23 of the retrieved implants.


Assuntos
Alongamento Ósseo/instrumentação , Pinos Ortopédicos/efeitos adversos , Parafusos Ósseos/efeitos adversos , Adolescente , Adulto , Idoso , Criança , Corrosão , Estudos Transversais , Dinamarca , Remoção de Dispositivo , Fêmur/cirurgia , Humanos , Pessoa de Meia-Idade , Tíbia/cirurgia , Adulto Jovem
13.
Clin Orthop Relat Res ; 475(2): 442-451, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27554268

RESUMO

BACKGROUND: We previously introduced a manual surgical technique that makes small perforations (cracks) through the sclerotic bone shell that typically forms during the process of aseptic loosening ("crack" revision technique). Perforating just the shell (without violating the proximal cortex) can maintain overall bone continuity while allowing marrow and vascular elements to access the implant surface. Because many revisions require bone graft to fill defects, we wanted to determine if bone graft could further increase implant fixation beyond what we have experimentally shown with the crack technique alone. Also, because both titanium (Ti6Al4V) and hydroxyapatite (HA) implant surfaces are used in revisions, we also wanted to determine their relative effectiveness in this model. QUESTIONS/PURPOSES: We hypothesized that both (1) allografted plasma-sprayed Ti6Al4V; and (2) allografted plasma-sprayed HA-coated implants inserted with a crack revision technique have better fixation compared with a noncrack revision technique in each case. METHODS: Under approval from our Institutional Animal Care and Use Committee, a female canine animal model was used to evaluate the uncemented revision technique (crack, noncrack) using paired contralateral implants while implant surface (Ti6Al4V, HA) was qualitatively compared between the two (unpaired) series. All groups received bone allograft tightly packed around the implant. This revision model includes a cylindrical implant pistoning 500 µm in a 0.75-mm gap, with polyethylene particles, for 8 weeks. This engenders a bone and tissue response representative of the metaphyseal cancellous region of an aseptically loosened component. At 8 weeks, the original implants were revised and followed for an additional 4 weeks. Mechanical fixation was assessed by load, stiffness, and energy to failure when loaded in axial pushout. Histomorphometry was used to determine the amount and location of bone and fibrous tissue in the grafted gap. RESULTS: The grafted crack revision improved mechanical shear strength, stiffness, and energy to failure (for Ti6Al4V 27- to 69-fold increase and HA twofold increases). The histomorphometric analysis demonstrated primarily fibrous membrane ongrowth and in the gap for the allografted Ti6Al4V noncrack revisions. For allografted HA noncrack revisions, bone ongrowth at the implant surface was observed, but fibrous tissue also was present in the inner gap. Although both Ti6Al4V and HA surfaces showed improved fixation with grafted crack revision, and Ti6Al4V achieved the highest percent gain, HA demonstrated the strongest overall fixation. CONCLUSIONS: The results of this study suggest that novel osteoconductive or osteoinductive coatings and bone graft substitutes or tissue-engineered constructs may further improve bone-implant fixation with the crack revision technique but require evaluation in a rigorous model such as presented here. CLINICAL RELEVANCE: This experimental study provides data on which to base clinical trials aimed to improve fixation of revision implants. Given the multifactorial nature of complex human revisions, such a protocoled clinical study is required to determine the clinical applicability of this approach.


Assuntos
Artroplastia/métodos , Transplante Ósseo/métodos , Durapatita , Titânio , Animais , Substitutos Ósseos , Materiais Revestidos Biocompatíveis , Cães , Feminino , Modelos Animais , Osseointegração , Reoperação
14.
BMC Musculoskelet Disord ; 18(1): 441, 2017 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-29132335

RESUMO

BACKGROUND: Initial micromotion of a total hip replacement is associated with aseptic loosening. The use of bisphosphonates could be one way to reduce peri-implant bone resorption induced by micromotion. Bisphosphonates compounds are inhibitors of bone resorption. The aim of this study was to investigate whether local treatment with bisphosphonate would reduce bone resorption and fibrous tissue around an experimental implant subjected to micromotion. METHODS: One micromotion implant were inserted into each medial femoral condyle in ten sheep. During each gait cycle the implant axially piston 0.5 mm. During surgery one of the femoral condyles were locally treated with 0.8 mg zoledronate. The other condyle served as control. Observation period was 12 weeks. RESULTS: Histological evaluation showed a fibrous capsule around both the control and bisphosphonate implants. Histomorphometrical analysis showed that 97% of the surface on both control and bisphosphonate implants were covered by fibrous tissue. However, the bisphosphonate was able to preserve bone in a 1 mm zone around the implants. CONCLUSION: This study indicates that local treatment with bisphosphonate cannot prevent the formation of a fibrous capsule around an implant subjected to micromotion, but bisphosphonate is able to reduce resorption of peri-prosthetic bone.


Assuntos
Conservadores da Densidade Óssea/uso terapêutico , Reabsorção Óssea/prevenção & controle , Difosfonatos/uso terapêutico , Imidazóis/uso terapêutico , Animais , Conservadores da Densidade Óssea/farmacologia , Difosfonatos/farmacologia , Avaliação Pré-Clínica de Medicamentos , Fibrose , Imidazóis/farmacologia , Falha de Prótese/efeitos dos fármacos , Ovinos , Ácido Zoledrônico
15.
J Arthroplasty ; 32(6): 1894-1901, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28111123

RESUMO

BACKGROUND: Short-term experimental and animal studies have confirmed superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. METHODS: Forty-four hips in 42 patients (19 men) were randomly operated using cementless hydroxyapatite-coated Bi-Metric stems. Patients were followed with radiostereometric analysis at baseline, 6 and 12 weeks, 1, 2, and 5 years, and measurements of periprosthetic bone mineral density at baseline, 1, 2, and 5 years. Complications during the study period and clinical outcome measures of Harris Hip Score were recorded at mean 7 years (5-8.8) after surgery. RESULTS: Absolute migrations of medio/lateral translations between the broaching group and the compaction group of mean 0.14 mm (standard deviation [SD] 0.10) vs mean 0.30 mm (SD 0.27) (P = .01) at 1 year, and of mean 0.13 mm (SD 0.10) vs 0.34 mm (0.31) (P = .01) at 5 years were different. Absolute valgus/varus rotations of mean 0.12° (SD 0.13°) in the broaching group were less than mean 0.35° (0.45°) in the compaction group (P < .01) at 1 year, but at 5 years no difference was observed (P = .19). Subsidence and retroversion were similar between groups at all follow-ups (P > .13). The compaction group had significantly less bone loss than the broaching group in Gruen zone 3 (distal-lateral to the stem) at 1 and 5 years. No further differences in bone mineral density changes were found between groups up to 5 years after surgery. Complications throughout the period and clinical outcome measures of Harris Hip Score were similar at 7 years (5-8.8) after surgery. CONCLUSION: We found increased migration when preparing the bone with compaction compared with broaching in cementless femoral stems.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Absorciometria de Fóton , Adulto , Idoso , Densidade Óssea , Durapatita , Feminino , Fêmur/diagnóstico por imagem , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Análise Radioestereométrica , Fatores de Tempo , Raios X
17.
Acta Orthop ; 87(6): 575-582, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27759486

RESUMO

Background and purpose - Short-term experimental studies have confirmed that there is superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Patients and methods - 1-stage, bilateral primary THA was performed in 28 patients between May 2001 and September 2007. The patients were randomized to femoral bone preparation with broaching on 1 side and compaction on the other side. 8 patients declined to attend the postoperative follow-up, leaving 20 patients (13 male) with a mean age of 58 (36-70) years for evaluation. The patients were followed with radiostereometric analysis (RSA) at baseline, at 6 and 12 weeks, and at 1, 2, and 5 years, and measurements of periprosthetic bone mineral density (BMD) at baseline and at 1, 2, and 5 years. The subjective part of the Harris hip score (HHS) and details of complications throughout the observation period were obtained at a mean interval of 6.3 (3.0-9.5) years after surgery. Results - Femoral stems in the compaction group had a higher degree of medio-lateral migration (0.21 mm, 95% CI: 0.03-0.40) than femoral stems in the broaching group at 5 years (p = 0.02). No other significant differences in translations or rotations were found between the 2 surgical techniques at 2 years (p > 0.4) and 5 years (p > 0.7) postoperatively. There were no individual stems with continuous migration. Periprosthetic BMD in the 7 Gruen zones was similar at 2 years and at 5 years. Intraoperative femoral fractures occurred in 2 of 20 compacted hips, but there were none in the 20 broached hips. The HHS and dislocations were similar in the 2 groups at 6.3 (3.0-9.5) years after surgery. Interpretation - Bone compaction as a surgical technique with the Bi-Metric stem did not show the superior outcomes expected compared to conventional broaching. Furthermore, 2 periprosthetic fractures occurred using the compaction technique, so we cannot recommend compaction for insertion of the cementless Bi-Metric stem.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Fêmur/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Fraturas Periprotéticas/prevenção & controle , Absorciometria de Fóton/métodos , Adolescente , Adulto , Idoso , Densidade Óssea , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico , Fraturas Periprotéticas/diagnóstico , Fraturas Periprotéticas/etiologia , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
18.
Acta Orthop ; 87(sup363): 1-5, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28271925

RESUMO

The combination of modern interventional and preventive medicine has led to an epidemic of ageing. While this phenomenon is a positive consequence of an improved lifestyle and achievements in a society, the longer life expectancy is often accompanied by decline in quality of life due to musculoskeletal pain and disability. The Aarhus Regenerative Orthopaedics Symposium (AROS) 2015 was motivated by the need to address regenerative challenges in an ageing population by engaging clinicians, basic scientists, and engineers. In this position paper, we review our contemporary understanding of societal, patient-related, and basic science-related challenges in order to provide a reasoned roadmap for the future to deal with this compelling and urgent healthcare problem.


Assuntos
Envelhecimento/fisiologia , Sistema Musculoesquelético/fisiopatologia , Medicina Regenerativa/métodos , Animais , Comorbidade , Modelos Animais de Doenças , Humanos , Regeneração/fisiologia
19.
J Orthop Case Rep ; 14(1): 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38292091

RESUMO

Introduction: The aim is to report early clinical results of an experimental surgical procedure, injecting bone void filler, for patients with lower extremity rheumatoid arthritis (RA) insufficiency fractures. Case Report: We used a cross-sectional design with retrospective follow-up. Patient-reported outcomes were reported by the body-region specific questionnaires, knee injury and osteoarthritis outcome score (KOOS), or foot and ankle outcome score (FOAS). The Eq5D-5L questionnaire reported overall health-related quality of life (QoL). Furthermore, patient satisfaction (semi-structured interview), pain reactions, and adverse events were reported.Results from the first five patients were included. The median age was 70 years (range 50-80). Fracture localizations were proximal tibia (2), distal tibia (2), and distal femur (1). Four out of five patients reported a high degree of patient satisfaction following treatment. Four out of five patients at follow-up reported no pain from the fracture location. The median improvement from baseline to follow-up on the KOOS/FAOS subscale scores was pain 65 (range 42-69), symptoms 39 (range 25-50), the activity of daily living 41 (range 29-51), sport and recreational activities (sport/rec) 48 (range 40-60), and QoL 60 (range 57-72). The median improvement for the Eq5D index was 0.30 (range 0.26-0.36). Conclusion: Surgical treatment of insufficiency fractures in RA patients with bone void filler seems promising. Four out of five patients reported considerable improvement in function and QoL and substantially lower pain scores following treatment. More research is needed to investigate the efficacy of this novel surgical procedure.

20.
EFORT Open Rev ; 9(2): 119-128, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38308954

RESUMO

Purpose: The objective of this scoping review was to describe the extent and type of evidence of using guided growth to correct rotational deformities of long bones in children. Methods: This scoping review was conducted in accordance with the JBI methodology for scoping reviews. All published and unpublished studies investigating surgical methods using guided growth to perform gradual rotation of long bones were included. Results: Fourteen studies were included: one review, three clinical studies, and ten preclinical studies. In the three clinical studies, three different surgical methods were used on 21 children. Some degree of rotation was achieved in all but two children. Adverse effects reported included limb length discrepancy (LLD), knee stiffness and rebound of rotation after removal of tethers. Of the ten preclinical studies, two were ex vivo and eight were in vivo. Rotation was achieved in all preclinical studies. Adverse effects reported included implant extrusions, LLD, articular deformities, joint stiffness and rebound of rotation after removal of tethers. Two of the studies reported on histological changes. Conclusions: All studies conclude that guided growth is a potential treatment for rotational deformities of long bones. There is great variation in animal models and surgical methods used and in reported adverse effects. More research is needed to shed light on the best surgical guided growth method, its effectiveness as well as the involved risks and complications. Based on current evidence the procedure is still to be considered experimental. Level of evidence: 4.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA