Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ther Drug Monit ; 39(3): 235-242, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28490046

RESUMO

BACKGROUND: Gemcitabine (2',2'-difluoro-2'-deoxycytidine) is a nucleoside analog used as a single agent and in combination regimens for the treatment of a variety of solid tumors. Several studies have shown a relationship between gemcitabine peak plasma concentration (Cmax) and hematological toxicity. An immunoassay for gemcitabine in plasma was developed and validated to facilitate therapeutic drug monitoring (TDM) by providing an economical, robust method for automated chemistry analyzers. METHODS: A monoclonal antibody was coated on nanoparticles to develop a homogenous agglutination inhibition assay. To prevent ex vivo degradation of gemcitabine in blood, tetrahydrouridine was used as a sample stabilizer. Validation was conducted for precision, recovery, cross-reactivity, and linearity on a Beckman Coulter AU480. Verification was performed on an AU5800 in a hospital laboratory. A method comparison was performed with (LC-MS/MS) liquid chromatography tandem mass spectrometry using clinical samples. Selectivity was demonstrated by testing cross-reactivity of the major metabolite, 2',2'-difluorodeoxyuridine. RESULTS: Coefficients of variation for repeatability and within-laboratory precision were <8%. The deviation between measured and assigned values was <3%. Linear range was from 0.40 to 33.02 µ/mL (1.5-125.5 µM). Correlation with validated LC-MS/MS methods was R = 0.977. The assay was specific for gemcitabine: there was no cross-reactivity to 2',2'-difluorodeoxyuridine, chemotherapeutics, concomitant, or common medications tested. Tetrahydrouridine was packaged in single-use syringes. Gemcitabine stability in whole blood was extended to 8 hours (at room temperature) and in plasma to 8 days (2-8°C). CONCLUSIONS: The assay demonstrated the selectivity, test range, precision, and linearity to perform reliable measurements of gemcitabine in plasma. The addition of stabilizer improved the sample handling. Using general clinical chemistry analyzers, gemcitabine could be measured for TDM.


Assuntos
Desoxicitidina/análogos & derivados , Plasma/química , Anticorpos Monoclonais/química , Cromatografia Líquida de Alta Pressão/métodos , Desoxicitidina/sangue , Monitoramento de Medicamentos/métodos , Humanos , Imunoensaio/métodos , Limite de Detecção , Nanopartículas/química , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Gencitabina
2.
Ther Drug Monit ; 37(4): 486-92, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25551407

RESUMO

BACKGROUND: Imatinib pharmacokinetic variability and the relationship of trough concentrations with clinical outcomes have been extensively reported. Although physical methods to quantitate imatinib exist, they are not widely available for routine use. An automated homogenous immunoassay for imatinib has been developed, facilitating routine imatinib testing. METHODS: Imatinib-selective monoclonal antibodies, without substantial cross-reactivity to the N-desmethyl metabolite or N-desmethyl conjugates, were produced. The antibodies were conjugated to 200 nm particles to develop immunoassay reagents on the Beckman Coulter AU480 analyzer. These reagents were analytically validated using Clinical Laboratory Standards Institute protocols. Method comparison to liquid chromatography tandem mass spectrometry (LC-MS/MS) was conducted using 77 plasma samples collected from subjects receiving imatinib. RESULTS: The assay requires 4 µL of sample without pretreatment. The nonlinear calibration curve ranges from 0 to 3000 ng/mL. With automated sample dilution, concentrations of up to 9000 ng/mL can be quantitated. The AU480 produces the first result in 10 minutes and up to 400 tests per hour. Repeatability ranged from 2.0% to 6.0% coefficient of variation, and within-laboratory reproducibility ranged from 2.9% to 7.4% coefficient of variation. Standard curve stability was 2 weeks and on-board reagent stability was 6 weeks. For clinical samples with imatinib concentrations from 438 to 2691 ng/mL, method comparison with LC-MS/MS gave a slope of 0.995 with a y-intercept of 24.3 and a correlation coefficient of 0.978. CONCLUSIONS: The immunoassay is suitable for quantitating imatinib in human plasma, demonstrating good correlation with a physical method. Testing for optimal imatinib exposure can now be performed on routine clinical analyzers.


Assuntos
Mesilato de Imatinib/sangue , Mesilato de Imatinib/imunologia , Imunoensaio/métodos , Anticorpos Monoclonais/imunologia , Automação , Calibragem , Cromatografia Líquida de Alta Pressão , Humanos , Limite de Detecção , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA