Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Dig Liver Dis ; 55(8): 1019-1025, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37217373

RESUMO

BACKGROUND: The FACET study is a prospective, open-label, low risk interventional clinical trial aiming at exploring the fitness-for-purpose and usability of an electronic device suite for the detection of hand-foot skin reaction symptoms in patients with metastatic colorectal cancer treated with regorafenib. METHODS: 38 patients with metastatic colorectal cancer are being selected in 6 centers in France, and will be followed for 2 regorafenib treatment cycles, or for approximately 56 days. The electronic device suite includes connected insoles and a mobile device equipped with a camera and a companion application with electronic patient-reported outcomes questionnaires and educational material. The FACET study is intended to provide information useful for the improvement of the electronic device suite and its usability before the testing of its robustness in a larger follow-up study. This paper describes the protocol of the FACET study and discusses the limitations to consider for the implementation of digital devices in real-life practice.


Assuntos
Neoplasias Colorretais , Humanos , Estudos Prospectivos , Seguimentos , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/patologia , Compostos de Fenilureia/efeitos adversos
2.
Diabetes Care ; 35(11): 2182-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22875230

RESUMO

OBJECTIVE: A key milestone in progress towards providing an efficacious and safe closed-loop artificial pancreas system for outpatient use is the development of fully automated, portable devices with fault detection capabilities to ensure patient safety. The ability to remotely monitor the operation of the closed-loop system would facilitate future physician-supervised home studies. RESEARCH DESIGN AND METHODS: This study was designed to investigate the efficacy and safety of a fully automated, portable, closed-loop system. The Medtronic Portable Glucose Control System (PGCS) consists of two subcutaneous glucose sensors, a control algorithm based on proportional-integral-derivative with insulin feedback operating from a BlackBerry Storm smartphone platform, Bluetooth radiofrequency translator, and an off-the-shelf Medtronic Paradigm Veo insulin pump. Participants with type 1 diabetes using insulin pump therapy underwent two consecutive nights of in-clinic, overnight, closed-loop control after a baseline open-loop assessment. RESULTS: Eight participants attended for 16 overnight studies. The PGCS maintained mean overnight plasma glucose levels of 6.4 ± 1.7 mmol/L (115 ± 31 mg/dL). The proportion of time with venous plasma glucose <3.9, between 3.9 and 8 (70 and 144 mg/dL), and >8 mmol/L was 7, 78, and 15%, respectively. The proportion of time the sensor glucose values were maintained between 3.9 and 8 mmol/L was greater for closed-loop than open-loop (84.5 vs. 46.7%; P < 0.0001), and time spent <3.3 mmol/L was also reduced (0.9 vs. 3%; P < 0.0001). CONCLUSIONS: These results suggest that the PGCS, an automated closed-loop device, is safe and effective in achieving overnight glucose control in patients with type 1 diabetes.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Adolescente , Adulto , Algoritmos , Criança , Feminino , Humanos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA