Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(16): 1220-1230, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37634187

RESUMO

BACKGROUND: Computed tomography (CT) is recommended for guiding transcatheter aortic valve replacement (TAVR). However, a sizable proportion of TAVR candidates have chronic kidney disease, in whom the use of iodinated contrast media is a limitation. Cardiac magnetic resonance imaging (CMR) is a promising alternative, but randomized data comparing the effectiveness of CMR-guided versus CT-guided TAVR are lacking. METHODS: An investigator-initiated, prospective, randomized, open-label, noninferiority trial was conducted at 2 Austrian heart centers. Patients evaluated for TAVR according to the inclusion criteria (severe symptomatic aortic stenosis) and exclusion criteria (contraindication to CMR, CT, or TAVR, a life expectancy <1 year, or chronic kidney disease level 4 or 5) were randomized (1:1) to undergo CMR or CT guiding. The primary outcome was defined according to the Valve Academic Research Consortium-2 definition of implantation success at discharge, including absence of procedural mortality, correct positioning of a single prosthetic valve, and proper prosthetic valve performance. Noninferiority was assessed using a hybrid modified intention-to-treat/per-protocol approach on the basis of an absolute risk difference margin of 9%. RESULTS: Between September 11, 2017, and December 16, 2022, 380 candidates for TAVR were randomized to CMR-guided (191 patients) or CT-guided (189 patients) TAVR planning. Of these, 138 patients (72.3%) in the CMR-guided group and 129 patients (68.3%) in the CT-guided group eventually underwent TAVR (modified intention-to-treat cohort). Of these 267, 19 patients had protocol deviations, resulting in a per-protocol cohort of 248 patients (121 CMR-guided, 127 CT-guided). In the modified intention-to-treat cohort, implantation success was achieved in 129 patients (93.5%) in the CMR group and in 117 patients (90.7%) in the CT group (between-group difference, 2.8% [90% CI, -2.7% to 8.2%]; P<0.01 for noninferiority). In the per-protocol cohort (n=248), the between-group difference was 2.0% (90% CI, -3.8% to 7.8%; P<0.01 for noninferiority). CONCLUSIONS: CMR-guided TAVR was noninferior to CT-guided TAVR in terms of device implantation success. CMR can therefore be considered as an alternative for TAVR planning. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03831087.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Insuficiência Renal Crônica/cirurgia , Fatores de Risco
2.
Mov Disord ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38686449

RESUMO

BACKGROUND: Early studies in cellular models suggested an iron accumulation in Friedreich's ataxia (FA), yet findings from patients are lacking. OBJECTIVES: The objective is to characterize systemic iron metabolism, body iron storages, and intracellular iron regulation in FA patients. METHODS: In FA patients and matched healthy controls, we assessed serum iron parameters, regulatory hormones as well as the expression of regulatory proteins and iron distribution in peripheral blood mononuclear cells (PBMCs). We applied magnetic resonance imaging with R2*-relaxometry to quantify iron storages in the liver, spleen, and pancreas. Across all evaluations, we assessed the influence of the genetic severity as expressed by the length of the shorter GAA-expansion (GAA1). RESULTS: We recruited 40 FA patients (19 women). Compared to controls, FA patients displayed lower serum iron and transferrin saturation. Serum ferritin, hepcidin, mean corpuscular hemoglobin and mean corpuscular volume in FA inversely correlated with the GAA1-repeat length, indicating iron deficiency and restricted availability for erythropoiesis with increasing genetic severity. R2*-relaxometry revealed a reduction of splenic and hepatic iron stores in FA. Liver and spleen R2* values inversely correlated with the GAA1-repeat length. FA PBMCs displayed downregulation of ferritin and upregulation of transferrin receptor and divalent metal transporter-1 mRNA, particularly in patients with >500 GAA1-repeats. In FA PBMCs, intracellular iron was not increased, but shifted toward mitochondria. CONCLUSIONS: We provide evidence for a previously unrecognized iron starvation signature at systemic and cellular levels in FA patients, which is related to the underlying genetic severity. These findings challenge the use of systemic iron lowering therapies in FA. © 2024 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.

3.
Diabetologia ; 66(4): 754-767, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36525084

RESUMO

AIMS/HYPOTHESIS: Sodium-glucose cotransporter 2 (SGLT2) inhibitors are widely used in the treatment of type 2 diabetes, heart failure and chronic kidney disease. Their role in the prevention of diet-induced metabolic deteriorations, such as obesity, insulin resistance and fatty liver disease, has not been defined yet. In this study we set out to test whether empagliflozin prevents weight gain and metabolic dysfunction in a mouse model of diet-induced obesity and insulin resistance. METHODS: C57Bl/6 mice were fed a western-type diet supplemented with empagliflozin (WDE) or without empagliflozin (WD) for 10 weeks. A standard control diet (CD) without or with empagliflozin (CDE) was used to control for diet-specific effects. Metabolic phenotyping included assessment of body weight, food and water intake, body composition, hepatic energy metabolism, skeletal muscle mitochondria and measurement of insulin sensitivity using hyperinsulinaemic-euglycaemic clamps. RESULTS: Mice fed the WD were overweight, hyperglycaemic, hyperinsulinaemic and insulin resistant after 10 weeks. Supplementation of the WD with empagliflozin prevented these metabolic alterations. While water intake was significantly increased by empagliflozin supplementation, food intake was similar in WDE- and WD-fed mice. Adipose tissue depots measured by MRI were significantly smaller in WDE-fed mice than in WD-fed mice. Additionally, empagliflozin supplementation prevented significant steatosis found in WD-fed mice. Accordingly, hepatic insulin signalling was deteriorated in WD-fed mice but not in WDE-fed mice. Empagliflozin supplementation positively affected size and morphology of mitochondria in skeletal muscle in both CD- and WD-fed mice. CONCLUSIONS/INTERPRETATION: Empagliflozin protects mice from diet-induced weight gain, insulin resistance and hepatic steatosis in a preventative setting and improves muscle mitochondrial morphology independent of the type of diet.


Assuntos
Diabetes Mellitus Tipo 2 , Resistência à Insulina , Hepatopatia Gordurosa não Alcoólica , Camundongos , Animais , Resistência à Insulina/fisiologia , Diabetes Mellitus Tipo 2/metabolismo , Obesidade/metabolismo , Fígado/metabolismo , Hepatopatia Gordurosa não Alcoólica/metabolismo , Aumento de Peso , Insulina/metabolismo , Dieta Ocidental , Camundongos Endogâmicos C57BL , Dieta Hiperlipídica
4.
Eur Radiol ; 33(7): 4973-4980, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36800012

RESUMO

OBJECTIVES: To compare the quantitative measurement of splenic and pancreatic iron content using a commercial 3D-Dixon sequence (qDixon) versus an established fat-saturated R2* relaxometry method (ME-GRE). METHODS: We analyzed splenic and pancreatic iron levels in 143 MR examinations (1.5 T) using the qDixon and a ME-GRE sequence (108 patients: 65 males, 43 females, mean age 61.31 years). Splenic and pancreatic R2* values were compared between both methods using Bland-Altman plots, concordance correlation coefficients (CCC), and linear regression analyses. Iron overload (R2* > 50 1/s) was defined for both organs and compared using contingency tables, overall agreement, and Gwet's AC1 coefficient. RESULTS: Of all analyzable examinations, the median splenic R2* using the qDixon sequence was 25.75 1/s (range: 5.6-433) and for the ME-GRE sequence 35.35 1/s (range: 10.9-400.8) respectively. Concerning the pancreas, a median R2* of 29.93 1/s (range: 14-111.45) for the qDixon and 31.25 1/s (range: 14-97) for the ME-GRE sequence was found. Bland-Altman analysis showed a mean R2* difference of 2.12 1/s with a CCC of 0.934 for the spleen and of 0.29 1/s with a CCC of 0.714 for the pancreas. Linear regression for the spleen/pancreas resulted in a correlation coefficient of 0.94 (p < 0.001)/0.725 (p < 0.001). Concerning iron overload, the proportion of overall agreement between the two methods was 91.43% for the spleen and 93.18% for the pancreas. CONCLUSIONS: Our data show good concordance between R2* values obtained with a commercial qDixon sequence and a validated ME-GRE relaxometry method. The 3D-qDixon sequence, originally intended for liver assessment, seems to be a reliable tool for non-invasive evaluation of iron content also in the spleen and the pancreas. KEY POINTS: • A 3D chemical shift imaging sequence and 2D multi-gradient echo sequence show good conformity quantifying splenic and pancreatic R2* values. • The 3D chemical shift imaging sequence allows a reliable analysis also of splenic and pancreatic iron status. • In addition to the liver, the analysis of the spleen and pancreas is often helpful for further differential diagnostic clarification and patient guidance regarding the iron status.


Assuntos
Sobrecarga de Ferro , Ferro , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Ferro/análise , Baço/diagnóstico por imagem , Estudos Retrospectivos , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/química , Pâncreas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
Eur Radiol ; 33(2): 1219-1228, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35980426

RESUMO

OBJECTIVES: To investigate the prognostic value of pulmonary transit time (pTT) determined by cardiac magnetic resonance (CMR) after acute ST-segment-elevation myocardial infarction (STEMI). METHODS: Comprehensive CMR examinations were performed in 207 patients 3 days and 4 months after reperfused STEMI. Functional parameters and infarct characteristics were assessed. PTT was defined as the interval between peaks of gadolinium contrast time-intensity curves in the right and left ventricles in first-pass perfusion imaging. Cox regression models were calculated to assess the association between pTT and the occurrence of major adverse cardiac events (MACE), defined as a composite of death, re-infarction, and congestive heart failure. RESULTS: PTT was 8.6 s at baseline and 7.8 s at the 4-month CMR. In Cox regression, baseline pTT (hazard ratio [HR]: 1.58; 95% CI: 1.12 to 2.22; p = 0.009) remained significantly associated with MACE occurrence after adjustment for left ventricular ejection fraction (LVEF) and cardiac index. The association of pTT and MACE remained significant also after adjusting for infarct size and microvascular obstruction size. In Kaplan-Meier analysis, pTT ≥ 9.6 s was associated with MACE (p < 0.001). Addition of pTT to LVEF resulted in a categorical net reclassification improvement of 0.73 (95% CI: 0.27 to 1.20; p = 0.002) and integrated discrimination improvement of 0.07 (95% CI: 0.02 to 0.13; p = 0.007). CONCLUSIONS: After reperfused STEMI, CMR-derived pTT was associated with hard clinical events with prognostic information independent of and incremental to infarct size and LV systolic function. KEY POINTS: • Pulmonary transit time is the duration it takes the heart to pump blood from the right chambers across lung vessels to the left chambers. • This prospective single-centre study showed inferior outcome in patients with prolonged pulmonary transit time after myocardial infarction. • Pulmonary transit time assessed by magnetic resonance imaging added incremental information to established prognostic markers.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Volume Sistólico , Função Ventricular Esquerda , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/etiologia , Pulmão/patologia , Imagem Cinética por Ressonância Magnética/métodos
6.
Am J Hematol ; 98(6): 890-899, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36880875

RESUMO

Anemia of inflammation (AI) is frequently present in subjects with inflammatory disorders, primarily caused by inflammation-driven iron retention in macrophages. So far, only limited data on qualitative and quantitative estimates of tissue iron retention in AI patients exist. We performed a prospective cohort study analyzing splenic, hepatic, pancreatic, and cardiac iron content with MRI-based R2*-relaxometry in AI patients, including subjects with concomitant true iron deficiency (AI+IDA) hospitalized between 05/2020-01/2022. Control groups were individuals without inflammation. Spleen R2* values in AI patients with ferritin ≤200 µg/L (AI+IDA) were comparable with those found in controls. In AI patients with ferritin >200 µg/L, spleen (47.6 s-1 vs. 19.3 s-1 , p < .001) and pancreatic R2* values (32.5 s-1 vs. 24.9 s-1 , p = .011) were significantly higher compared with controls, while liver and heart R2*-values did not differ. Higher spleen R2* values were associated with higher ferritin, hepcidin, CRP, and IL-6 concentrations. Spleen R2* values normalized in AI patients after recovery (23.6 s-1 vs. 47.6 s-1 , p = .008), while no changes were found in patients with baseline AI+IDA. This is the first study investigating tissue iron distribution in patients with inflammatory anemia and AI with concomitant true iron deficiency. The results support the findings in animal models demonstrating iron retention in macrophages, which are primarily accumulating in the spleen under inflammatory conditions. MRI-related iron measurement may help to better characterize actual iron needs and to define better biomarker thresholds in the diagnosis of true ID in patients with AI. It may qualify as a useful diagnostic method to estimate the need for iron supplementation and to guide therapy.


Assuntos
Anemia Ferropriva , Anemia , Deficiências de Ferro , Animais , Ferro/metabolismo , Projetos Piloto , Estudos Prospectivos , Anemia/etiologia , Anemia Ferropriva/complicações , Hepcidinas , Ferritinas , Inflamação
7.
Hepatology ; 74(5): 2424-2435, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34048062

RESUMO

BACKGROUND AND AIMS: High serum ferritin is frequent among patients with chronic liver disease and commonly associated with hepatic iron overload. Genetic causes of high liver iron include homozygosity for the p.Cys282Tyr variant in homeostatic iron regulator (HFE) and rare variants in non-HFE genes. The aims of the present study were to describe the landscape and frequency of mutations in hemochromatosis genes and determine whether patient selection by noninvasive hepatic iron quantification using MRI improves the diagnostic yield of next-generation sequencing (NGS) in patients with hyperferritinemia. APPROACH AND RESULTS: A cohort of 410 unselected liver clinic patients with high serum ferritin (defined as ≥200 µg/L for women and ≥300 µg/L for men) was investigated by HFE genotyping and abdominal MRI R2*. Forty-one (10%) patients were homozygous for the p.Cys282Tyr variant in HFE. Of the remaining 369 patients, 256 (69%) had high transferrin saturation (TSAT; ≥45%) and 199 (53%) had confirmed hepatic iron overload (liver R2* ≥70 s-1 ). NGS of hemochromatosis genes was carried out in 180 patients with hepatic iron overload, and likely pathogenic variants were identified in 68 of 180 (38%) patients, mainly in HFE (79%), ceruloplasmin (25%), and transferrin receptor 2 (19%). Low spleen iron (R2* <50 s-1 ), but not TSAT, was significantly associated with the presence of mutations. In 167 patients (93%), no monogenic cause of hepatic iron overload could be identified. CONCLUSIONS: In patients without homozygosity for p.Cys282Tyr, coincident pathogenic variants in HFE and non-HFE genes could explain hyperferritinemia with hepatic iron overload in a subset of patients. Unlike HFE hemochromatosis, this type of polygenic hepatic iron overload presents with variable TSAT. High ferritin in blood is an indicator of the iron storage disease, hemochromatosis. A simple genetic test establishes this diagnosis in the majority of patients affected. MRI of the abdomen can guide further genetic testing.


Assuntos
Proteína da Hemocromatose/genética , Hemocromatose/diagnóstico por imagem , Hemocromatose/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Ferro/metabolismo , Hepatopatias/diagnóstico por imagem , Hepatopatias/genética , Imageamento por Ressonância Magnética/métodos , Seleção de Pacientes , Fenótipo , Adulto , Idoso , Ceruloplasmina/genética , Feminino , Ferritinas/sangue , Seguimentos , Testes Genéticos , Genótipo , Hemocromatose/sangue , Homozigoto , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Fígado/patologia , Hepatopatias/sangue , Masculino , Pessoa de Meia-Idade , Mutação , Receptores da Transferrina/genética , Estudos Retrospectivos
8.
J Cardiovasc Magn Reson ; 24(1): 7, 2022 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-34986847

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) is the diagnostic routine standard for assessing aortic stenosis (AS). However, its inaccuracies in determining stroke volume (SV) and aortic valve area (AVA) call for a more precise and dependable method. Phase-contrast cardiovascular magnetic resonance imaging (PC-CMR) is a promising tool to push these boundaries. Thus, the aim of this study was to validate a novel approach based on PC-CMR against the gold-standard of invasive determination of AVA in AS compared to TTE. METHODS: A total of 50 patients with moderate or severe AS underwent TTE, cardiac catheterization and CMR. AVA via PC-CMR was determined by plotting momentary flow across the valve against flow-velocity. SV by CMR was measured directly via PC-CMR and volumetrically using cine-images. Invasive SV and AVA were determined via Fick-principle and Gorlin-formula, respectively. TTE yielded SV and AVA using continuity equation. Gradients were calculated via the modified Bernoulli-equation. RESULTS: SV by PC-CMR (85 ± 31 ml) correlated strongly (r: 0.73, p < 0.001) with cine-CMR (85 ± 19 ml) without significant bias (lower and upper limits of agreement (LLoA and ULoA): - 41 ml and 44 ml, p = 0.83). In PC-CMR, mean pressure gradient correlated significantly with invasive determination (r: 0.36, p = 0.011). Mean AVA, as determined by PC-CMR during systole (0.78 ± 0.25 cm2), correlated moderately (r: 0.54, p < 0.001) with invasive AVA (0.70 ± 0.23 cm2), resulting in a small bias of 0.08 cm2 (LLoA and ULoA: - 0.36 cm2 and 0.55 cm2, p = 0.017). Inter-methodically, AVA by TTE (0.81 ± 0.23 cm2) compared to invasive determination showed similar correlations (r: 0.58, p < 0.001 with a bias of 0.11 cm2, LLoA and ULoA: - 0.30 and 0.52, p < 0.001) to PC-CMR. Intra- and interobserver reproducibility were excellent for AVA (intraclass-correlation-coefficients of 0.939 and 0.827, respectively). CONCLUSIONS: Our novel approach using continuous determination of flow-volumes and velocities with PC-CMR enables simple AVA measurement with no bias to invasive assessment. This approach highlights non-invasive AS grading through CMR, especially when TTE findings are inconclusive.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
9.
Eur Radiol ; 31(4): 2252-2262, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32965571

RESUMO

OBJECTIVES: To prospectively evaluate a 3D-multiecho-Dixon sequence with inline calculation of proton density fat fraction (PDFF) and R2* (qDixon), and an improved version of it (qDixon-WIP), for the MR-quantification of hepatic iron in a clinical setting. METHODS: Patients with increased serum ferritin underwent 1.5-T MRI of the liver for the evaluation of hepatic iron overload. The imaging protocol for R2* quantification included as follows: (1) a validated, 2D multigradient-echo sequence (initial TE 0.99 ms, R2*-ME-GRE), (2) a 3D-multiecho-Dixon sequence with inline calculation of PDFF and R2* (initial TE 2.38 ms, R2*-qDixon), and optionally (3) a prototype (works-in-progress, WIP) version of the latter (initial TE 1.04 ms, R2*-qDixon-WIP) with improved water/fat separation and noise-corrected parameter fitting. For all sequences, three manually co-registered regions of interest (ROIs) were placed in the liver. R2* values were compared and linear regression analysis and Bland-Altman plots calculated. RESULTS: Forty-six out of 415 patients showed fat-water (F/W) swap with qDixon and were excluded. A total of 369 patients (mean age 52 years) were included; in 203/369, the optional qDixon-WIP was acquired, which showed no F/W swaps. A strong correlation was found between R2*-ME-GRE and R2*-qDixon (r2 = 0.92, p < 0.001) with Bland-Altman revealing a mean difference of - 3.82 1/s (SD = 21.26 1/s). Correlation between R2*-GRE-ME and R2*-qDixon-WIP was r2 = 0.95 (p < 0.001) with Bland-Altman showing a mean difference of - 0.125 1/s (SD = 30.667 1/s). CONCLUSIONS: The 3D-multiecho-Dixon sequence is a reliable tool to quantify hepatic iron. Results are comparable with established relaxometry methods. Improvements to the original implementation eliminate occasional F/W swaps and limitations regarding maximum R2* values. KEY POINTS: • The 3D-multiecho-Dixon sequence for 1.5 T is a reliable tool to quantify hepatic iron. • Results of the 3D-multiecho-Dixon sequence are comparable with established relaxometry methods. • An improved version of the 3D-multiecho-Dixon sequence eliminates minor drawbacks.


Assuntos
Sobrecarga de Ferro , Ferro , Biópsia , Humanos , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Eur Radiol ; 30(11): 6014-6021, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32556465

RESUMO

OBJECTIVES: To evaluate magnetic resonance cholangiopancreatography (MRCP) with compressed sensing (CS) for the assessment of branch duct intraductal papillary mucinous neoplasm (BD-IPMN) of the pancreas. For this purpose, conventional navigator-triggered (NT) sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) MRCP was compared with various CS-SPACE-MRCP sequences in a clinical setting. METHODS: A total of 41 patients (14 male, 27 female, mean age 68 years) underwent 1.5-T MRCP for the evaluation of BD-IPMN. The MRCP protocol consisted of the following sequences: conventional NT-SPACE-MRCP, CS-SPACE-MRCP with long (BHL, 17 s) and short single breath-hold (BHS, 8 s), and NT-CS-SPACE-MRCP. Two board-certified radiologists evaluated image quality, duct sharpness, duct visualization, lesion conspicuity, confidence, and communication with the main pancreatic duct in consensus using a 5-point scale (1-5), with higher scores indicating better quality/delineation/confidence. Maximum intensity projection reconstructions and originally acquired data were used for evaluation. Wilcoxon signed-rank test was used to compare the intra-individual difference between sequences. RESULTS: BHS-CS-SPACE-MRCP had the highest scores for image quality (3.85 ± 0.79), duct sharpness (3.81 ± 1.05), and duct visualization (3.81 ± 1.01). There was a significant difference compared with NT-CS-SPACE-MRCP (p < 0.05) but no significant difference to the standard NT-SPACE-MRCP (p > 0.05). Concerning diagnostic quality, BHS-CS-SPACE-MRCP had the highest scores in lesion conspicuity (3.95 ± 0.92), confidence (4.12 ± 1.08), and communication (3.8 ± 1.06), significantly higher compared with NT-SPACE-MRCP, BHL-SPACE-MRCP, and NT-CS-SPACE-MRCP (p = <0.05). CONCLUSIONS: MRCP with CS 3D SPACE for the evaluation of BD-IPMN at 1.5 T provides the best results using a short breath-hold sequence. This approach is feasible and an excellent alternative to standard NT 3D MRCP sequences. KEY POINTS: • 1.5-T MRCP with compressed sensing for the evaluation of branch duct IPMN is a feasible method. • Short breath-hold sequences provide the best results for this purpose.


Assuntos
Colangiopancreatografia por Ressonância Magnética/métodos , Neoplasias Intraductais Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Pâncreas , Ductos Pancreáticos/diagnóstico por imagem , Pressão
11.
Eur Radiol ; 30(9): 4847-4856, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32318849

RESUMO

OBJECTIVES: To prospectively compare unenhanced quiescent-interval single-shot MR angiography (QISS-MRA) with contrast-enhanced computed tomography angiography (CTA) for contrast-free guidance in transcatheter aortic valve intervention (TAVI). METHODS: Twenty-six patients (mean age 83 ± 5 years, 15 female [58%]) referred for TAVI evaluation underwent QISS-MRA for aortoiliofemoral access guidance and non-contrast three-dimensional (3D) "whole heart" MRI for prosthesis sizing on a 1.5-T system. Contrast-enhanced CTA was performed as imaging gold standard for TAVI planning. Image quality was assessed by a 4-point Likert scale; continuous MRA and CTA measurements were compared with regression and Bland-Altman analyses. RESULTS: QISS-MRA and CTA-based measurements of aortoiliofemoral vessel diameters correlated moderately to very strong (r = 0.572 to 0.851, all p ≤ 0.002) with good to excellent inter-observer reliability (intra-class correlation coefficient (ICC) = 0.862 to 0.999, all p < 0.0001) regarding QISS assessment. Mean diameters of the infrarenal aorta and iliofemoral vessels differed significantly (bias 0.37 to 0.98 mm, p = 0.041 to < 0.0001) between the two modalities. However, inter-method decision for transfemoral access route was comparable (κ = 0.866, p < 0.0001). Aortic root parameters assessed by 3D whole heart MRI strongly correlated (r = 0.679 to 0.887, all p ≤ 0.0001) to CTA measurements. CONCLUSION: QISS-MRA provides contrast-free access route evaluation in TAVI patients with moderate to strong correlations compared with CTA and substantial inter-observer agreement. Despite some significant differences in minimal vessel diameters, inter-method agreement for transfemoral accessibility is strong. Combination with 3D whole heart MRI facilitates unenhanced TAVI guidance. KEY POINTS: • QISS-MRA and CTA inter-method agreement for transfemoral approach is strong. • QISS-MRA is a very good alternative to CTA and MRA especially in patients with Kidney Disease Outcomes Quality Initiativestages 4 and 5. • Combination of QISS-MRA and 3D "whole heart" MRI facilitates fully unenhanced TAVI guidance.


Assuntos
Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/farmacologia , Doenças das Valvas Cardíacas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Reprodutibilidade dos Testes
12.
Radiologe ; 60(10): 966-978, 2020 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-32399783

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) is a noninvasive, quantitative, MRI-based method to evaluate liver stiffness. Beside biopsy and ultrasound elastography, this imaging method plays in many places a significant role in the detection and additive characterization of chronic liver disease. OBJECTIVES, MATERIALS AND METHODS: Based on the literature, a brief review of the underlying method and the commercially available products is given. Furthermore, the practical procedure, the analysis, and the interpretation of clinically relevant questions are illustrated and a comparison with ultrasound elastography is provided. RESULTS: This relative "young" MRI method allows extensive evaluation of mechanical properties of the liver and is an important diagnostic tool especially in follow-up examinations. The MRE of the liver is with a maximum technical failure rate of 5.8% a robust technique with high accuracy and an excellent re-test reliability as well as intra- and interobserver reproducibility. There is a high diagnostic certainty within the framework of most important clinical indications, the quantification of fibrosis, and with a very good correlation with the "gold standard" biopsy. CONCLUSION: Based on its rising clinical relevance and the broad usage, MRE of the liver is increasingly used in many centers and in routine liver protocols. Therefore, basic knowledge of this method is essential for every radiologist.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Hepatopatias , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
13.
J Neurosci ; 38(31): 6983-7003, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29954847

RESUMO

In cortical structures, principal cell activity is tightly regulated by different GABAergic interneurons (INs). Among these INs are vasoactive intestinal polypeptide-expressing (VIP+) INs, which innervate preferentially other INs, providing a structural basis for temporal disinhibition of principal cells. However, relatively little is known about VIP+ INs in the amygdaloid basolateral complex (BLA). In this study, we report that VIP+ INs have a variable density in the distinct subdivisions of the mouse BLA. Based on different anatomical, neurochemical, and electrophysiological criteria, VIP+ INs could be identified as IN-selective INs (IS-INs) and basket cells expressing CB1 cannabinoid receptors. Whole-cell recordings of VIP+ IS-INs revealed three different spiking patterns, none of which was associated with the expression of calretinin. Genetic targeting combined with optogenetics and in vitro recordings enabled us to identify several types of BLA INs innervated by VIP+ INs, including other IS-INs, basket and neurogliaform cells. Moreover, light stimulation of VIP+ basket cell axon terminals, characterized by CB1 sensitivity, evoked IPSPs in ∼20% of principal neurons. Finally, we show that VIP+ INs receive a dense innervation from both GABAergic inputs (although only 10% from other VIP+ INs) and distinct glutamatergic inputs, identified by their expression of different vesicular glutamate transporters.In conclusion, our study provides a wide-range analysis of single-cell properties of VIP+ INs in the mouse BLA and of their intrinsic and extrinsic connectivity. Our results reinforce the evidence that VIP+ INs are structurally and functionally heterogeneous and that this heterogeneity could mediate different roles in amygdala-dependent functions.SIGNIFICANCE STATEMENT We provide the first comprehensive analysis of the distribution of vasoactive intestinal polypeptide-expressing (VIP+) interneurons (INs) across the entire mouse amygdaloid basolateral complex (BLA), as well as of their morphological and physiological properties. VIP+ INs in the neocortex preferentially target other INs to form a disinhibitory network that facilitates principal cell firing. Our study is the first to demonstrate the presence of such a disinhibitory circuitry in the BLA. We observed structural and functional heterogeneity of these INs and characterized their input/output connectivity. We also identified several types of BLA INs that, when inhibited, may provide a temporal window for principal cell firing and facilitate associative plasticity, e.g., in fear learning.


Assuntos
Complexo Nuclear Basolateral da Amígdala/citologia , Interneurônios/fisiologia , Peptídeo Intestinal Vasoativo/análise , Potenciais de Ação , Animais , Complexo Nuclear Basolateral da Amígdala/fisiologia , Contagem de Células , Conectoma , Cruzamentos Genéticos , Genes Reporter , Ácido Glutâmico/metabolismo , Potenciais Pós-Sinápticos Inibidores/efeitos da radiação , Interneurônios/química , Interneurônios/classificação , Interneurônios/efeitos da radiação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neurônios/metabolismo , Optogenética , Técnicas de Patch-Clamp , Terminações Pré-Sinápticas/ultraestrutura , Receptor CB1 de Canabinoide/análise , Proteínas Vesiculares de Transporte de Glutamato/metabolismo , Ácido gama-Aminobutírico/metabolismo
14.
AJR Am J Roentgenol ; 213(6): 1315-1323, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31553656

RESUMO

OBJECTIVE. The objective of our study was to compare ultrasound (US) tophus and monosodium urate (MSU) deposit detection and US tophus size in the metatarsophalangeal (MTP) 1 joint with dual-energy CT (DECT) using two DECT postprocessing protocols in patients presenting with podagra. SUBJECTS AND METHODS. Seventy-five consecutive patients with podagra (66 men and nine women; mean age, 65.6 years; age range, 33-88 years) and 75 control subjects with MTP 1 joint osteoarthritis (49 men and 26 women; mean age, 63.0 years; age range, 35-87 years) prospectively underwent US and DECT between 2016 and 2018 to assess the MTP 1 joint. Two Syngovia postprocessing DECT protocols with different minimum attenuation thresholds of 150 HU (DECT 150 protocol) versus 120 HU (DECT 120 protocol) and the same maximum attenuation threshold (500 HU) and constant kilovoltage setting of tubes A and B at 80 and 140 kVp were evaluated. Interobserver variability of the two DECT protocols was calculated and compared with that of US. RESULTS. The postprocessing DECT 150 protocol was positive for tophus detection in 55 of 75 patients (73.3%) with podagra, whereas the postprocessing DECT 120 protocol detected MSU deposits in all 75 patients (100%). Tophus size assessed using the DECT 120 protocol showed an improved correlation with tophus size detected on US (p < 0.01). Interobserver variability of DECT was improved when using the DECT 120 protocol (p < 0.01). CONCLUSION. The postprocessing DECT 120 protocol enables improved visualization of MSU deposits and provides more accurate information about tophus size that better correlates with tophus size on US compared with the standard postprocessing DECT 150 protocol.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Articulação Metatarsofalângica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ácido Úrico/análise
15.
Eur Radiol ; 28(5): 2013-2021, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29264636

RESUMO

PURPOSE: To determine whether CAIPIRINHA-Dixon-TWIST (CDT) volume-interpolated breath-hold examination (VIBE) improves image quality by reducing gadoxetate-disodium-associated transient arterial-phase motion artefacts in magnetic resonance imaging (MRI) of the liver. MATERIALS AND METHODS: MRI studies of the liver from 270 patients who had received gadoxetate disodium were retrospectively evaluated in regard to arterial timing accuracy and arterial phase motion artefact severity (VIBE: 90/270, CAIPIRINHA-VIBE: 90/270 and CDT-VIBE: 90/270 cases). Three independent and blinded readers assessed arterial phase timing and motion artefact severity (5-point scale). Interrater agreement was calculated by weighted kappa. Continuous variables were compared via a two-sided ANOVA, categorical variables via a χ2 test. An ordinal regression analysis was performed to identify other predictors of motion artefacts. RESULTS: CDT-VIBE improved correct late arterial timing rates and reduced motion-related image deterioration rates. Successful late arterial liver visualisation was achieved in 56.7% (VIBE) compared with 66.7% (CAIPIRINHA-VIBE) and 84.4% (CDT-VIBE) (P < 0.0001). Good/excellent image quality was achieved in 56.7% vs. 66.7% and 73.3%, respectively (P = 0.03). Male sex negatively influenced image quality (P = 0.03). CONCLUSION: CDT-VIBE increases the diagnostic utility of gadoxetate disodium-based liver MRI by reducing respiratory motion artefacts and optimising late arterial visualisation compared with VIBE and CAIPIRINHA-VIBE. KEY POINTS: • CAIPIRINHA-Dixon-TWIST-VIBE-MRI (CDT) mitigates effects of acute transient dyspnoea caused by gadoxetate disodium. • CDT improves late arterial imaging compared with VIBE and CAIPIRINHA-VIBE. • The rate of ideal late arterial images is higher with CDT-VIBE vs. VIBE or CAIPI-VIBE. • The impact of respiratory motion artefacts on arterial phase images can be reduced.


Assuntos
Artefatos , Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Criança , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
16.
Eur Radiol ; 28(11): 4625-4634, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29736853

RESUMO

OBJECTIVES: To compare a comprehensive cardiovascular magnetic resonance imaging (MRI) protocol with contrast-enhanced computed tomography angiography (CTA) for guidance in transcatheter aortic valve replacement (TAVR) evaluation. METHODS AND RESULTS: Non-contrast three-dimensional (3D) 'whole heart' MRI imaging for aortic annulus sizing and measurements of coronary ostia heights, contrast-enhanced MRI angiography (MRA) for evaluation of transfemoral routes as well as aortoiliofemoral-CTA were performed in 16 patients referred for evaluation of TAVR. Aortic annulus measurements by MRI and CTA showed a very strong correlation (r=0.956, p<0.0001; effective annulus area for MRI 430±74 vs. 428±78 mm2 for CTA, p=0.629). Regarding decision for valve size there was complete consistency between MRI and CTA. Moreover, vessel luminal diameters and angulations of aortoiliofemoral access as measured by MRA and CTA showed overall very strong correlations (r= 0.819 to 0.996, all p<0.001), the agreement of minimal vessel diameter between the two modalities revealed a bias of 0.02 mm (upper and lower limit of agreement: 1.02 mm and -0.98 mm). CONCLUSIONS: In patients referred for TAVR, MRI measurements of aortic annulus and minimal aortoiliofemoral diameters showed good to excellent agreement. Decisions based on MRI measurements regrading prosthesis sizing and transfemoral access would not have modified TAVR-strategy as compared to a CTA-based choice. KEY POINTS: • 'Whole heart' MRI and CTA measurements of aortic annulus correlate very strongly. • MRI- and CTA-based prostheses sizing are in excellent agreement. • MRA and CTA equally guide TAVR access strategy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Valva Aórtica/diagnóstico por imagem , Feminino , Próteses Valvulares Cardíacas , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
17.
Ann Neurol ; 79(6): 1026-30, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27016314

RESUMO

We assessed loss of dorsolateral nigral hyperintensity (DNH) on high-field susceptibility-weighted imaging (SWI), a novel magnetic resonance imaging marker for Parkinson's disease (PD), in 15 subjects with idiopathic rapid eye movement sleep behavior disorder (iRBD) and compared findings to 42 healthy controls (HCs) and 104 PD patients. We found loss of DNH in at least two thirds of iRBD subjects, which approaches the rate observed in PD and is in contrast to findings in HCs. We propose that absence of DNH on high-field SWI could identify prodromal degenerative parkinsonism in iRBD. Ann Neurol 2016;79:1026-1030.


Assuntos
Transtorno do Comportamento do Sono REM/patologia , Substância Negra/patologia , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neuroimagem , Doença de Parkinson/patologia , Sintomas Prodrômicos
18.
Mov Disord ; 32(10): 1457-1464, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28714593

RESUMO

BACKGROUND: Imaging markers that are sensitive to parkinsonism across multiple sites are critically needed for clinical trials. The objective of this study was to evaluate changes in the substantia nigra using single- and bi-tensor models of diffusion magnetic resonance imaging in PD, MSA, and PSP. METHODS: The study cohort (n = 425) included 107 healthy controls and 184 PD, 63 MSA, and 71 PSP patients from 3 movement disorder centers. Bi-tensor free water, free-water-corrected fractional anisotropy, free-water-corrected mean diffusivity, single-tensor fractional anisotropy, and single-tensor mean diffusivity were computed for the anterior and posterior substantia nigra. Correlations were computed between diffusion MRI measures and clinical measures. RESULTS: In the posterior substantia nigra, free water was greater for PSP than MSA and PD patients and controls. PD and MSA both had greater free water than controls. Free-water-corrected fractional anisotropy values were greater for PSP patents than for controls and PD patients. PSP and MSA patient single-tensor mean diffusivity values were greater than controls, and single-tensor fractional anisotropy values were lower for PSP patients than for healthy controls. The parkinsonism effect size for free water was 0.145 in the posterior substantia nigra and 0.072 for single-tensor mean diffusivity. The direction of correlations between single-tensor mean diffusivity and free-water values and clinical scores was similar at each site. CONCLUSIONS: Free-water values in the posterior substantia nigra provide a consistent pattern of findings across patients with PD, MSA, and PSP in a large cohort across 3 sites. Free water in the posterior substantia nigra relates to clinical measures of motor and cognitive symptoms in a large cohort of parkinsonism. © 2017 International Parkinson and Movement Disorder Society.


Assuntos
Imagem de Tensor de Difusão , Processamento de Imagem Assistida por Computador , Doença de Parkinson/diagnóstico por imagem , Substância Negra/diagnóstico por imagem , Água , Idoso , Análise de Variância , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Estatística como Assunto , Paralisia Supranuclear Progressiva/diagnóstico por imagem
19.
J Magn Reson Imaging ; 46(3): 793-800, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28225576

RESUMO

PURPOSE: To prospectively evaluate a new 3D-multiecho-Dixon (3D-ME-Dixon) sequence for the quantification of hepatic iron and fat in a clinical setting. MATERIALS AND METHODS: In all, 120 patients underwent 1.5T magnetic resonance imaging of the liver between December 2013 and June 2015 including the following three sequences: 3D-ME-Dixon with inline calculation of R2* and proton-density fat-fraction (PDFF) maps, single-voxel-spectroscopy (SVS), 2D multigradient-echo sequence (2D-ME-GRE). SVS and 2D-ME-GRE were used as reference for PDFF and R2*, respectively. R2*- and PDFF-values from 3D-ME-Dixon were compared with those of the reference. Linear regression analysis, Bland-Altman plots, and agreement parameters were calculated. RESULTS: In total, 103 patients were finally included (87 men and 16 women; mean age, 50.51 years); 17/120 were excluded due to fat/water-swaps or R2*-values exceeding the constraint of 400 1/s for 3D-ME-Dixon. A strong correlation (r = 0.992, P < 0.001) between R2* of 3D-ME-Dixon and the reference 2D-ME-GRE was found. Bland-Altman analysis revealed systematically lower values for 3D-ME-Dixon (16.499%). Using an adapted threshold of 57 1/s, 3D-ME-Dixon obtained a positive/negative percentage agreement (PPA/NPA) of 84.4%/91.4% for detecting hepatic iron overload. For hepatic fat the correlation between 3D-ME-Dixon and the reference SVS was strong (r = 0.957, P < 0.001); PPA/NPA was 88.3%/91.4%. CONCLUSION: The 3D-ME-Dixon sequence is a valuable tool for the evaluation of hepatic iron and fat in a clinical setting. Fat/water-swaps remain a drawback requiring improvements to the implementation and making it necessary to have proven conventional sequences at hand in case of an eventual occurrence. LEVEL OF EVIDENCE: 1. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:793-800.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Fígado Gorduroso/diagnóstico por imagem , Imageamento Tridimensional/métodos , Ferro , Fígado/diagnóstico por imagem , Fígado/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA