Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 132(8): 1111-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22622793

RESUMO

PURPOSE: Bone loss around uncemented femoral components is suspected to precede implant loosening and contribute to problems in revision surgery. Short-stemmed cementless femoral components are designed to preserve proximal femoral bone stock and ultimately the longevity of the prosthesis. METHODS: With quantitative computed tomography-assisted osteodensitometry, we prospectively analyzed femoral cortical and cancellous bone density (BD) and contact area changes of an uncemented collum femoris preserving stem (n = 38) 10 days, 1, 3 and 7 years post-operatively. RESULTS: Seven years post-operatively, cancellous BD (mg CaHA/mL) had decreased by as much as -66 % and cortical BD by up to -27 % at the metaphyseal portion of the femur; the decrease was progressive between the 1- and 3-year examinations and halted thereafter. Contact area (in % out of a possible 100 %) decreased proximally between the 1- and 3-year follow-up. CONCLUSION: Proximal cortical and cancellous bone density loss and decrease of contact area indicate that metaphyseal fixation cannot be achieved. The lack of cortical BD loss and increase of contact area values below the trochanter minor suggest diaphyseal fixation.


Assuntos
Artroplastia de Quadril/métodos , Densidade Óssea , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/anatomia & histologia , Colo do Fêmur , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Estresse Mecânico , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos
2.
Int Orthop ; 35(2): 195-200, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21079952

RESUMO

Ceramic-on-ceramic coupling is thought to be a durable alternative to metal- or alumina-on-polyethylene pairing. No evidence exists suggesting superior clinical and radiological results for hydroxyapatite-coated stems versus uncoated stems. The aim of this study is to report the performance of an alumina-on-alumina bearing cementless total hip arthroplasty and to compare stems with a tapered design with and without hydroxyapatite coating. We prospectively analysed the results of cementless tapered femoral stems (40 hydroxyapatite-coated versus 22 uncoated stems), a metal-backed fibre mesh hydroxyapatite-coated socket and alumina-on-alumina pairing. Of 75 hips studied, 62 were available for follow-up (mean of 10.5 years after surgery). The average Harris hip score was 90. Only one hydroxyapatite-coated stem was revised for aseptic loosening. One instance of non-progressive osteolysis was detected around a screw of a cup. All other components showed radiographic signs of stable ingrowth. Hydroxyapatite coating of the stem had no significant impact on the clinical or radiological results. Total hip arthroplasty with the presented implant and pairing provides a durable standard for all patients requiring hip joint replacement against which all newer generations of cementless implants should be judged.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Adulto , Idoso , Óxido de Alumínio , Artroplastia de Quadril/métodos , Cimentação , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos
3.
Arch Orthop Trauma Surg ; 131(4): 549-55, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20924764

RESUMO

AIM: Tissue sparing hip prostheses are becoming more and more popular especially for the treatment of younger patients. The objective of this study was to evaluate the clinical and radiological results after insertion of a tissue sparing hip prosthesis. METHOD: In 47 consecutive non-selected patients (50 hips), the clinical and radiographic results of cementless total hip arthroplasty using a collum femoris preserving stem, a pressfit cup and an alumina-polyethylene pairing were prospectively evaluated. The mean age at index-surgery was 58 (36-82) years, there were 38 women and 9 men. After a mean follow-up of 6.8 years (minimum 6.1 years), two patients had died and one patient underwent revision surgery due to aseptic loosening of the stem. RESULTS: The overall survival rate of the acetabular component was 100% and of the femoral component 98%. The mean Harris hip score at follow-up was 94 points. CONCLUSION: The mid-term survival with this type of total hip arthroplasty is excellent and compares equal with uncemented straight stems in this age group.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Luxação Congênita de Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Ossificação Heterotópica/epidemiologia , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos , Resultado do Tratamento
4.
J Bone Joint Surg Am ; 93(12): 1152-7, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21776552

RESUMO

BACKGROUND: As a follow-up of a previously reported three-year study, we analyzed the periprosthetic acetabular cortical and cancellous bone density changes at ten years after implantation of a press-fit cup. METHODS: Prospective clinical, radiographic, and quantitative computed tomography examinations were performed within ten days and at mean periods of one, three, and ten years after total hip arthroplasty with a press-fit cup, a femoral stem with a tapered design, and alumina-alumina pairing. Periacetabular cortical and cancellous bone density (mg CaHA/mL) in the cranial, ventral, and dorsal regions about the cup were measured for twenty-four hips in vivo. RESULTS: All acetabular cups showed radiographic signs of stable ingrowth, and no acetabular component had to be revised. The loss of periacetabular cancellous bone density about the cup was as much as -37% cranially, -60% ventrally, and -71% dorsally; the decrease was progressive between the one-year and three-year examinations only. In contrast, cortical bone density above the dome of the acetabular cup remained constant throughout the ten-year follow-up. A moderate change in cortical bone density of -5% to -18% was seen at the level of the cup ten years postoperatively. CONCLUSIONS: Both periacetabular cortical and cancellous bone density changes were nonprogressive between the three-year and ten-year examinations after press-fit cup fixation.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/instrumentação , Densidade Óssea , Prótese de Quadril , Pelve/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/métodos , Remodelação Óssea , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Pelve/cirurgia , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA