Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Pharmazie ; 65(3): 162-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20383934

RESUMO

During stress degradation studies of pioglitazone hydrochloride, one major unknown oxidative degradation impurity and two major unknown base degradation impurities were identified by LC-MS. These impurities were isolated using preparative liquid chromatography. Based on the spectral data (1H NMR, 13C NMR, MS and IR), oxidative degradation impurity, base degradation impurity-1 and base degradation impurity-2 were characterized as pioglitazone N-oxide, 3-(4-(2-(5-ethylpyridine-2yl) ethoxy) phenyl)-2-mercaptopropanoic acid and 2-(1-carboxy-2-{4-[2-(5-ethylpyridine-2yl)-ethoxy] phenyl}-ethyl disulfanyl)-3-{4-[2-(5-ethylpyridine-2yl)-ethoxy] phenyl propanoicacid, respectively. The formation and mechanism of these impurities were discussed and presented.


Assuntos
Ácido 3-Mercaptopropiônico/análogos & derivados , Hipoglicemiantes/química , Propionatos/análise , Piridinas/análise , Tiazolidinedionas/química , Ácido 3-Mercaptopropiônico/análise , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Contaminação de Medicamentos , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Oxirredução , Pioglitazona , Espectrometria de Massas por Ionização por Electrospray , Espectroscopia de Infravermelho com Transformada de Fourier
2.
Pharmazie ; 64(12): 800-3, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20095136

RESUMO

A simple and accurate high-performance liquid chromatographic method was developed for the determination of exo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine in endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine, commercially known as grantamine and used as a key intermediate in the preparation of granisetron bulk drug. Chromatographic separation of the exo and endo isomers of 9-methyl-9-azabicyclo[3.3.1]nonan-3-amine was achieved on an Inertsil C8 column using a mobile phase containing 0.3% trifluoroacetic acid. The resolution between the two isomers was found to be more than 4. The limit of detection (LOD) and limit of quantification (LOQ) of exo isomer were 0.8 and 2.5 microg x mL(-1) respectively, for a 10 microL injection volume. The percentage recovery of exo-isomer ranged from 99 to 102% w/w in the endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine sample. The test solution and mobile phase were observed to be stable up to 48 h after preparation. The validated method yielded good results for precision, linearity, accuracy, robustness and ruggedness. The proposed method was found to be suitable and accurate for the quantitative determination of exo-isomer in bulk samples of endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine.


Assuntos
Antieméticos/análise , Compostos Bicíclicos com Pontes/análise , Granisetron/análise , Cromatografia Líquida de Alta Pressão , Indicadores e Reagentes , Isomerismo , Reprodutibilidade dos Testes , Soluções
3.
J Chromatogr Sci ; 48(10): 807-10, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21044410

RESUMO

A rapid, sensitive, and accurate ultra-fast liquid chromatographic method is developed for the determination of related substances and degradants of Solifenacin Succinate, an active pharmaceutical ingredient used in the treatment of overactive bladder. Chromatographic separation of Solifenacin Succinate, its related substances, and degradants was achieved using a Shimpack XR-ODS-II column and mobile phase system containing 10 mM potassium dihydrogen orthophosphate in water. The pH of the buffer was adjusted to 7.0 using triethyl amine (mobile phase A). LC-grade acetonitrile was used as mobile phase B, employing a binary-gradient program at a flow rate 0.5 mL/min. The resolution between the critical pair of peaks (Impurity A and analyte) was found to be greater than 3.5. The limits of detection and quantification (LOQ) of Impurity A, Impurity B, and the analyte were 0.2 and 0.6 µg/mL, respectively for a 5-µL injection volume. The percentage recovery of impurities in the presence of sample matrix ranged from 95 to 104 w/w. The test solution and mobile phase was observed to be stable up to 24 h after the preparation. The validated method yielded good results of precision, linearity, accuracy, robustness, and ruggedness. The proposed method is found to be rapid, accurate, and suitable for the quantitative determination of related substances and degradants during quality control of Solifenacin Succinate active pharmaceutical ingredient.


Assuntos
Cromatografia Líquida/métodos , Antagonistas Muscarínicos/química , Quinuclidinas/química , Tetra-Hidroisoquinolinas/química , Contaminação de Medicamentos , Estabilidade de Medicamentos , Succinato de Solifenacina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA