RESUMO
The surface pH is a critical factor in the quality and longevity of materials and products. Traditional fast colorimetric pH detection-based tests such as water quality control or pregnancy tests, when results are determined by the naked eye, cannot provide quantitative values. Using standard pH papers, paper-printed comparison charts, or colorimetric microfluidic paper-based analytical devices is not suitable for such technological applications and quality management systems (QMSs) where the particular tested material should contain a suitable indicator in situ, in its structure, either before or after the process, the technology or the apparatus that are being tested. This paper describes a method based on the combination of impregnation of a tested material with a pH indicator in situ, its exposure to a process of technology whose impact on pH value is to be tested, colorimetric pH measurement, and approximation of pH value using derived pH characteristic parameters (pH-CPs) based on CIE orthogonal and cylindrical color variables. The hypotheses were experimentally verified using the methyl red pH indicator, impregnating the acid lignin-containing paper, and preparing a calibration sample set with pH in the range 4 to 12 using controlled alkalization. Based on the performed measurements and statistical evaluation, it can be concluded that the best pH-CPs with the highest regression parameters for pH are â∆E, ln (a),â∆H (ab), a/L, h/b and ln (b/a). The experimental results show that the presented method allows a good estimation of pH detection of the material surfaces.
RESUMO
Coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerges to scientific research and monitoring of wastewaters to predict the spread of the virus in the community. Our study investigated the COVID-19 disease in Bratislava, based on wastewater monitoring from September 2020 until March 2021. Samples were analyzed from two wastewater treatment plants of the city with reaching 0.6 million monitored inhabitants. Obtained results from the wastewater analysis suggest significant statistical dependence. High correlations between the number of viral particles in wastewater and the number of reported positive nasopharyngeal RT-qPCR tests of infected individuals with a time lag of 2 weeks/12 days (R2 = 83.78%/R2 = 52.65%) as well as with a reported number of death cases with a time lag of 4 weeks/27 days (R2 = 83.21%/R2 = 61.89%) was observed. The obtained results and subsequent mathematical modeling will serve in the future as an early warning system for the occurrence of a local site of infection and, at the same time, predict the load on the health system up to two weeks in advance.