Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Orthop Sci ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38890095

RESUMO

BACKGROUND: Even though 20% of chronic lateral ankle instability results from a combined anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) injury, only the ATFL is sutured using arthroscopic ligament repair techniques. Although some biomechanical and clinical studies have proved that isolated ATFL repair yields excellent results, previous biomechanical studies were performed using systems that only allow indirect estimations. The purpose of this study was to clarify strain patterns by directly measuring repaired ATFL and CFL strain patterns on cadaveric models that underwent isolated ATFL repair of a combined ATFL and CFL injury. METHODS: The miniaturization ligament performance probe (MLPP) system was used for directly measuring the strain patterns to insert the strain gauges into the mid-substance of normal and repaired ATFL and CFL fibers in five cadaveric specimens to allow measurement of strain patterns in the axial and three-dimensional motion of the ankle. RESULTS: The normal and repaired ATFL showed similar strain patterns in axial and three-dimensional motions. During the axial range of motion of the ankle, the repaired CFL showed a strain pattern almost similar to that of normal CFL, but the strain increased as the plantar flexion or dorsiflexion angle increased to the maximum value of 100 at 30° plantarflexion or strain values of 17-55/100 at 15°dorsiflexion. During three-dimensional motion, the repaired CFL was under the maximum value of 100 during dorsiflexion-inversion and exhibited less strain (7-38/100) during plantar flexion-eversion. CONCLUSION: The repaired CFL did not show a strain pattern that was completely consistent with a normal strain pattern; however, it did have some degree of tension similar to a normal strain pattern, even though it was not directly repaired.

2.
BMC Musculoskelet Disord ; 24(1): 915, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38012651

RESUMO

PURPOSE: To evaluate the radiographic diagnostic criteria and propose standardised radiographic criteria for Lisfranc injuries. METHODS: A systematic review of the PubMed and Embase databases was performed according to the PRISMA guidelines. The various radiographic criteria for the diagnosis of Lisfranc injuries were extracted. Descriptive statistics were presented for all continuous (as mean ± standard deviation) and categorical variables (as frequencies by percentages). RESULTS: The literature search included 29 studies that totalled 1115 Lisfranc injuries. The risk of bias ranged from "Low" to "Moderate" risk according to the ROBINS-I tool. The overall recommendations according to the GRADE assessment ranged from "Very Low" to "High". 1st metatarsal to 2nd metatarsal diastasis was the most common of the 12 various radiographic diagnostic criteria observed, as was employed in 18 studies. This was followed by 2nd cuneiform to 2nd metatarsal subluxation, as was employed in 11 studies. CONCLUSION: The radiographic diagnostic criteria of Lisfranc injuries were heterogeneous. The proposition for homogenous radiographic diagnostic criteria is that the following features must be observed for the diagnosis of Lisfranc injuries: 1st metatarsal to 2nd metatarsal diastasis of ≥ 2 mm on anteroposterior view or 2nd cuneiform to 2nd metatarsal subluxation on anteroposterior or oblique views. Further advanced imaging by CT or MRI may be required in patients with normal radiographs but with continued suspicion for Lisfranc injuries. LEVEL OF EVIDENCE: 4, systematic review.


Assuntos
Traumatismos do Pé , Luxações Articulares , Ossos do Metatarso , Humanos , Luxações Articulares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiografia , Ossos do Metatarso/diagnóstico por imagem , Ossos do Metatarso/lesões , Traumatismos do Pé/diagnóstico por imagem
3.
BMC Musculoskelet Disord ; 22(1): 558, 2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34144675

RESUMO

BACKGROUND: Inversion ankle sprains, or lateral ankle sprains, often result in symptomatic lateral ankle instability, and some patients need lateral ankle ligament reconstruction to reduce pain, improve function, and prevent subsequent injuries. Although anatomically reconstructed ligaments should behave in a biomechanically normal manner, previous studies have not measured the strain patterns of the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) after anatomical reconstruction. This study aimed to measure the strain patterns of normal and reconstructed ATFL and CFLs using the miniaturization ligament performance probe (MLPP) system. METHODS: The MLPP was sutured into the ligamentous bands of the ATFLs and CTLs of three freshly frozen cadaveric lower-extremity specimens. Each ankle was manually moved from 15° dorsiflexion to 30° plantar flexion, and a 1.2-N m force was applied to the ankle and subtalar joint complex. RESULTS: The normal and reconstructed ATFLs exhibited maximal strain (100) during supination in three-dimensional motion. Although the normal ATFLs were not strained during pronation, the reconstructed ATFLs demonstrated relative strain values of 16-36. During the axial motion, the normal ATFLs started to gradually tense at 0° plantar flexion, with the strain increasing as the plantar flexion angle increased, to a maximal value (100) at 30° plantar flexion; the reconstructed ATFLs showed similar strain patterns. Further, the normal CFLs exhibited maximal strain (100) during plantar flexion-abduction and relative strain values of 30-52 during dorsiflexion in three-dimensional motion. The reconstructed CFLs exhibited the most strain during dorsiflexion-adduction and demonstrated relative strain values of 29-62 during plantar flexion-abduction. During the axial motion, the normal CFLs started to gradually tense at 20° plantar flexion and 5° dorsiflexion. CONCLUSION: Our results showed that the strain patterns of reconstructed ATFLs and CFLs are not similar to those of normal ATFLs and CFLs.


Assuntos
Instabilidade Articular , Ligamentos Laterais do Tornozelo , Articulação do Tornozelo/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Ligamentos Laterais do Tornozelo/cirurgia , Tendões/cirurgia
4.
BMC Musculoskelet Disord ; 22(1): 208, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610165

RESUMO

BACKGROUND: Measuring the strain patterns of ligaments at various joint positions informs our understanding of their function. However, few studies have examined the biomechanical properties of ankle ligaments; further, the tensile properties of each ligament, during motion, have not been described. This limitation exists because current biomechanical sensors are too big to insert within the ankle. The present study aimed to validate a novel miniaturized ligament performance probe (MLPP) system for measuring the strain patterns of the anterior talofibular ligament (ATFL) during ankle motion. METHODS: Six fresh-frozen, through-the-knee, lower extremity, cadaveric specimens were used to conduct this study. An MLPP system, comprising a commercially available strain gauge (force probe), amplifier unit, display unit, and logger, was sutured into the midsubstance of the ATFL fibers. To measure tensile forces, a round, metal disk (a "clock", 150 mm in diameter) was affixed to the plantar aspect of each foot. With a 1.2-Nm load applied to the ankle and subtalar joint complex, the ankle was manually moved from 15° dorsiflexion to 30° plantar flexion. The clock was rotated in 30° increments to measure the ATFL strain detected at each endpoint by the miniature force probe. Individual strain data were aligned with the neutral (0) position value; the maximum value was 100. RESULTS: Throughout the motion required to shift from 15° dorsiflexion to 30° plantar flexion, the ATFL tensed near 20° (plantar flexion), and the strain increased as the plantar flexion angle increased. The ATFL was maximally tensioned at the 2 and 3 o'clock (inversion) positions (96.0 ± 5.8 and 96.3 ± 5.7) and declined sharply towards the 7 o'clock position (12.4 ± 16.8). Within the elastic range of the ATFL (the range within which it can return to its original shape and length), the tensile force was proportional to the strain, in all specimens. CONCLUSION: The MLPP system is capable of measuring ATFL strain patterns; thus, this system may be used to effectively determine the relationship between limb position and ATFL ankle ligament strain patterns.


Assuntos
Instabilidade Articular , Ligamentos Laterais do Tornozelo , Tornozelo , Articulação do Tornozelo , Fenômenos Biomecânicos , Cadáver , Humanos
5.
BMC Musculoskelet Disord ; 21(1): 289, 2020 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-32386522

RESUMO

BACKGROUND: There are few reports on the detailed biomechanics of the deltoid ligament, and no studies have measured the biomechanics of each ligamentous band because of the difficulty in inserting sensors into the narrow ligaments. This study aimed to measure the strain pattern of the deltoid ligament bands directly using a Miniaturization Ligament Performance Probe (MLPP) system. METHODS: The MLPP was sutured into the ligamentous bands of the deltoid ligament in 6 fresh-frozen lower extremity cadaveric specimens. The strain was measured using a round metal disk (clock) fixed on the plantar aspect of the foot. The ankle was manually moved from 15° dorsiflexion to 30° plantar flexion, and a 1.2-N-m force was applied to the ankle and subtalar joint complex. Then the clock was rotated every 30° to measure the strain of each ligamentous band at each endpoint. RESULTS: The tibionavicular ligament (TNL) began to tense at 10° plantar flexion, and the tension becomes stronger as the angle increased; the TNL worked most effectively in plantar flex-abduction. The tibiospring ligament (TSL) began to tense gradually at 15° plantar flexion, and the tension became stronger as the angle increased. The TSL worked most effectively in abduction. The tibiocalcaneal ligament (TCL) began to tense gradually at 0° dorsiflexion, and the tension became stronger as the angle increased. The TCL worked most effectively in pronation (dorsiflexion-abduction). The superficial posterior tibiotalar ligament (SPTTL) began to tense gradually at 0° dorsiflexion, and the tension became stronger as the angle increased, with the SPTTL working most effectively in dorsiflexion. CONCLUSION: Our results show the biomechanical function of the superficial deltoid ligament and may contribute to determining which ligament is damaged during assessment in the clinical setting.


Assuntos
Articulação do Tornozelo/fisiopatologia , Ligamentos Articulares/fisiopatologia , Amplitude de Movimento Articular , Rotação , Tornozelo , Fenômenos Biomecânicos , Cadáver , , Humanos
6.
Knee Surg Sports Traumatol Arthrosc ; 28(1): 298-304, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31535192

RESUMO

PURPOSE: To elucidate surgical outcomes in pediatric/adolescent patients with chronic lateral ankle instability and os subfibulare. METHODS: A retrospective chart review was conducted of pediatric/adolescent patients with chronic lateral ankle instability and os subfibulare following simultaneous ossicle resection and lateral ligament repair using suture anchors with subsequent immediate full weightbearing and active range of motion exercises for the ankle in our department between 2013 and 2017. Clinical outcomes were evaluated by comparing preoperative and final follow-up American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale (AOFAS) and Karlsson-Peterson ankle function scores. Intervals between surgery and return to physical education in school were determined. RESULTS: 31 feet of 15 male and 16 female patients were examined. Mean postoperative follow-up duration was 40.7 ± 12.7 (range 24-66) months. Mean AOFAS score increased significantly from 66.3 ± 2.5 (range 62-77) preoperatively to 96.5 ± 4.9 (range 87-100) at final follow-up (p < 0.001). Mean Karlsson-Peterson score increased significantly from 51.7 ± 4.0 (range 47-70) preoperatively to 95.3 ± 6.7 (range 80-100) at final follow-up (p < 0.001). Mean interval between surgery and return to physical education in school was 11.4 ± 1.6 (range 10-18) weeks. CONCLUSION: Simultaneous ossicle resection and lateral ligament repair using suture anchors with subsequent immediate full weightbearing and active ankle range of motion exercises may give excellent clinical outcomes with early return to physical activity for chronic lateral ankle instability with os subfibulare in pediatric/adolescent patients desiring an early return to physical activity. Level of evidence III.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia/métodos , Instabilidade Articular/cirurgia , Ligamentos Laterais do Tornozelo/cirurgia , Adolescente , Tornozelo/cirurgia , Traumatismos do Tornozelo/cirurgia , Artroplastia/estatística & dados numéricos , Criança , Exercício Físico , Feminino , Humanos , Masculino , Período Pós-Operatório , Amplitude de Movimento Articular , Estudos Retrospectivos , Volta ao Esporte , Âncoras de Sutura , Suporte de Carga
7.
BMC Musculoskelet Disord ; 20(1): 401, 2019 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-31481055

RESUMO

BACKGROUND: Stress fracture of the lateral tubercle of the posterior talar process in runners is extremely rare. Here, we describe a case of a female long-distance runner who sustained a stress fracture of the lateral tubercle of the posterior talar process. Osteosynthesis with screw fixation via two-portal hindfoot endoscopy achieved a good surgical outcome with a less invasive procedure. CASE PRESENTATION: An 18-year-old female long-distance runner who belonged to her university's road running club presented to our institution with a half-year history of persistent left hindfoot pain when running. Radiographs revealed a stress fracture of the lateral tubercle of the posterior talar process. Because the fracture showed no signs of healing 3 months after starting conservative therapy, osteosynthesis with screw fixation was performed via two-portal hindfoot endoscopy. Non-contrast computed tomography at 10 weeks postoperatively revealed consolidation of the stress fracture. At 15 weeks postoperatively, the patient was permitted to jog and return to athletic activity while wearing an orthosis. As of this writing 2 years postoperatively, she remains an active competitive runner. CONCLUSIONS: Osteosynthesis with screw fixation via two-portal hindfoot endoscopy was a less invasive procedure that successfully treated stress fracture of the lateral tubercle of the posterior talar process in this female long-distance runner.


Assuntos
Atletas , Endoscopia/métodos , Fixação Interna de Fraturas/métodos , Fraturas de Estresse/cirurgia , Tálus/lesões , Adolescente , Parafusos Ósseos , Endoscopia/instrumentação , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Aparelhos Ortopédicos , Radiografia , Corrida , Tálus/cirurgia , Resultado do Tratamento
9.
Foot Ankle Orthop ; 6(2): 24730114211003541, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35097441

RESUMO

BACKGROUND: The purpose of this retrospective study was to clarify the operative outcomes of the side-locking loop suture (SLLS) technique accompanied by autologous semitendinosus tendon grafting for chronic Achilles tendon rupture. METHODS: A chart review was conducted of consecutive patients treated with the SLLS technique at our department from 2012 to 2017. Postoperatively, a below-knee splint was applied for 2 weeks in 20 degrees of plantar flexion and then active range of motion exercise was started. Partial weightbearing exercise was allowed at 4 weeks according to patient tolerance, and full weightbearing without crutches was allowed at 8 weeks. The American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale score and the Achilles tendon rupture score (ATRS) were used to evaluate clinical outcomes preoperatively and at the final follow-up. RESULTS: Ten patients (6 men, 4 women) were included in the analysis. Mean AOFAS ankle-hindfoot scale score increased significantly from 64.2 ± 5.6 points preoperatively to 95.0 ± 5.3 points at the final follow-up (P < .001). The mean ATRS also increased significantly from 29.8 ± 4.4 points to 86.2 ± 7.7 points, respectively (P < .001). Mean time between surgery and ability to perform 20 continuous double-leg heel raises of the operated foot was 13.5 ± 3.4 (range 10-18) weeks. One patient complained of postoperative hypoesthesia in the foot, which had spontaneously resolved by 3 months after surgery. CONCLUSION: The SLLS technique accompanied by autologous semitendinosus tendon grafting provided successful operative outcomes for patients with chronic Achilles tendon rupture regardless of the size of the defect, and thus long-term orthotic use was not needed after surgery. LEVEL OF EVIDENCE: Level IV, retrospective case series.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA