Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Front Physiol ; 10: 47, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30778302

RESUMO

Dietary inorganic nitrate in beetroot can act as a source of nitric oxide and has been reported to lower brachial blood pressure (BP). This study examined the effect of inorganic nitrate in beetroot juice on aortic (central) BP acutely and over the subsequent 24-h period. A double blind, randomized, placebo-controlled crossover trial was performed in fifteen healthy, normotensive men and women (age 22-40 years). Participants were randomized to receive beetroot juice containing nitrate (6.5-7.3 mmol) or placebo beetroot juice from which nitrate had been removed (<0.06 mmol nitrate). Effects on aortic systolic BP were measured at 30 min (primary endpoint), 60 min and over a subsequent 24 h period using an ambulatory BP monitor. Carotid-femoral pulse wave velocity (cfPWV) was also measured at 30 min. Following a washout period, the procedure was repeated within 7 days with crossover to the opposite arm of the trial. Compared with placebo, ingestion of beetroot juice containing nitrate lowered aortic systolic BP at 30 min by 5.2 (1.9-8.5) mmHg [mean (95% confidence interval); p < 0.01]. A smaller effect on aortic systolic BP was observed at 60 min. There were minimal effects on brachial BP or cfPWV. Effects on aortic systolic BP were not sustained over the subsequent 24 h and there were no effects on other hemodynamic parameters during ambulatory monitoring. A single dose of beetroot juice containing nitrate lowers aortic BP more effectively than brachial BP in the short term, but the effects are comparatively short-lived and do not persist over the course of the same day.

2.
PLoS One ; 8(9): e75098, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24058652

RESUMO

BACKGROUND: Changes in ventricular rotation measured by two-dimensional speckle tracking echocardiography (2DSTE) are early indicators of cardiac disease. Data on the clinical feasibility of this important measure are scarce and there is no information on the comparability of different software versions. We assessed the feasibility, reproducibility and within patient temporal variability of 2DSTE in a large community based sample of older adults. We additionally compared 2DSTE results to those generated by 3DSTE. METHODS AND RESULTS: 1408 participants underwent transthoracic echocardiography. Using Philips Qlab 8.1 peak LV rotation at either the base or the apex was analysable in 432 (31%) participants. Peak twist measurements were achieved in 274 (20%) participants. 66 participants were randomly selected for the reproducibility study. 20 additional participants had scans 4-6 weeks apart for temporal variability and 3D echocardiography to assess the agreement between 2DSTE and 3DSTE. Reproducibility was evaluated using the intraclass coefficient of correlation (ICC). Better reproducibility for rotation and twist were obtained when measured at the endocardium, and when using more recent software versions, Peak twist and rotation were significantly different using two versions of the same software. Agreement with 3DSTE was better using newer software. CONCLUSION: Feasibility of 2DSTE is low in this cohort of elderly individuals severely limiting its utility in clinical settings. However if high quality images can be acquired assessment of ventricular rotation by 2DSTE is reproducible. Caution should be taken when comparing measurements of ventricular rotation by software from different vendors or different versions of software from the same vendor.


Assuntos
Ecocardiografia/instrumentação , Ecocardiografia/métodos , Endocárdio/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Software , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA