Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Acta Paediatr ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39295087

RESUMO

AIM: This scoping review aims to assess the utility of ultrasound as a prospective tool in measuring body composition and nutritional status in the paediatric population. We provide a comprehensive summary of the existing literature, identify gaps, and propose future research directions. METHODS: We conducted a systematic scoping review following the PRISMA Extension for Scoping Reviews guidelines. This involved screening titles and abstracts of relevant studies, followed by a detailed full-text review and extraction of pertinent data. RESULTS: We identified and synthesised 34 articles. The review revealed that while ultrasound has been used to assess body composition and bone properties in children, significant gaps remain in the literature. These include limited studies on ultrasound performance, insufficient attention to relevant sample characteristics, reliance on manual image measurements, and limited sample diversity. CONCLUSION: Point-of-care ultrasound shows significant promise for assessing paediatric body composition and nutritional status. To validate and enhance its effectiveness, further research is needed. Future studies should include larger and more diverse patient cohorts and conduct longitudinal investigations to evaluate nutritional interventions. Additionally, developing artificial intelligence (AI) for standardising and automating data interpretation will be crucial in improving the accuracy and efficiency of ultrasound assessments.

2.
Australas Psychiatry ; 32(1): 18-22, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37936255

RESUMO

OBJECTIVE: The Review of health services for children, young people and families within the NSW Health system identified that novel models of care were needed to improve access to clinical management for people with ADHD. The present study aimed to evaluate GPs' knowledge of and attitudes towards ADHD and the challenges and opportunities for a more substantial role for GPs in ADHD management. METHOD: An online survey of Australian GPs was conducted, with recruitment via email invitation. RESULTS: Out of 230 respondents, 213 surveys could be analysed. Of these, 97% believed ADHD was a genuine condition, with 90% identifying inattention as a primary symptom. Most (92%) had seen and diagnosed ADHD within the past year. Prevalent concerns included inadequate access to specialist assessment and treatment; 77% felt that GPs should have a more substantial role in ADHD management. Barriers included lack of time, knowledge and experience. CONCLUSIONS: There was willingness amongst respondents take on a greater role in managing individuals with ADHD. However, a need for further training and education was highlighted. The Australian Evidence-Based Clinical Practice Guideline for ADHD may resolve an identified need for clinical guidance.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Clínicos Gerais , Criança , Humanos , Adolescente , Transtorno do Deficit de Atenção com Hiperatividade/terapia , Austrália , Atitude , Inquéritos e Questionários , Conhecimentos, Atitudes e Prática em Saúde
3.
Ophthalmic Plast Reconstr Surg ; 33(1): e4-e7, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-25514664

RESUMO

We present an unusual case of upper eyelid coloboma repair in a patient with Goldenhar syndrome. We describe the use of a modified Cutler-Beard flap with concurrent inlay graft using cartilage from a preauricular appendage. This technique provides the benefits of autologous tissue, while minimizing donor site morbidity and reducing the risk of upper eyelid retraction.


Assuntos
Blefaroplastia/métodos , Coloboma/cirurgia , Pálpebras/anormalidades , Síndrome de Goldenhar/complicações , Pálpebras/cirurgia , Humanos , Recém-Nascido , Masculino , Resultado do Tratamento
5.
HSS J ; 18(2): 229-234, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35645647

RESUMO

Background: The current treatments for chronic knee osteoarthritis (OA), a disabling and costly healthcare condition in the United States, vary in their level of supporting evidence. Although total knee replacement is one of the best-supported interventions, its associated risks should not be taken lightly, especially in older patients with comorbidities. Genicular nerve block with subsequent genicular nerve radiofrequency neurotomy (GN-RFN) has emerged as a promising intervention for refractory pain in knee OA. Purposes/Questions: We sought to assess the pain and functional outcomes of genicular nerve bipolar radiofrequency neurotomy (B-RFN) for the treatment of chronic pain due to knee OA. Methods: A total of 21 patients who underwent unilateral genicular nerve B-RFN after positive diagnostic genicular nerve block (50% or greater pain relief) treated between July 2018 to December 2018 were included. Pain numeric rating scale (NRS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were collected at baseline, 3 months, and 6 months post-B-RFN. Changes at each time point were compared to baseline scores using paired sample t tests. Results: At 3 months, 62% of patients had a greater than 50% improvement in NRS scores and 57% of patients had a greater than 50% improvement in WOMAC scores. At 6 months, 81% of patients had a greater than 50% improvement in NRS scores and 67% had a greater than 50% improvement in WOMAC scores. The absolute change in mean NRS (± standard deviation) at 6 months went from 7.5 ± 1.9 to 2.5 ± 1.2. The absolute change in mean WOMAC scores at 6 months went from 46.9 ± 8.0 to 19.0 ± 6.2. Conclusion: Of 21 patients, 14 (67%) saw greater than 50% improvements in both NRS and WOMAC scores at 6 months after genicular nerve B-RFN. Further prospective studies are needed to determine the selection criteria of patients most likely to benefit from this procedure.

6.
Clin Imaging ; 59(1): 78-83, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31760281

RESUMO

BACKGROUND: Genicular nerve block and subsequent radiofrequency neurotomy (RFN) has emerged as a novel intervention and alternative for total knee arthroplasty in patients with refractory pain from knee osteoarthritis (OA). To our knowledge, there is no cited report correlating the accuracy of localizing the genicular nerves using bony landmarks on magnetic resonance imaging (MRI). OBJECTIVES: To quantify the proximity of superomedial genicular nerve (SMGN), superolateral genicular nerve (SLGN), and inferomedial genicular nerve (IMGN) from a target point. The target point was an intersection marked by a line parallel to the diaphysis and a separate line parallel to the metaphyseal flare along the cortical surfaces of both the femur and tibia. DESIGN: Retrospective chart review. PATIENTS: A total of 25 de-identified knee MRIs were reviewed. METHODS: The coronal proton density fat suppressed sequence was used for identification and localization of the SLGN, SMGN, and IMGN. The neurovascular bundles were traced from posterior location along their origin as they wrap around the distal diaphysis. The nerve locations were determined by consensus measurements performed by two board-certified radiologists with certificates of added qualification in neuroradiology and interventional radiology. The proximity of each respective genicular nerves was measured by drawing a perpendicular line from each genicular nerve to the height of the target point. All measurements were taken on the mid-coronal view at the point of maximal epiphyseal flare. MAIN OUTCOME MEASUREMENTS: Positive values indicated the location of the neurovascular bundle to be superior to the target point. Negative values indicated the location of the neurovascular bundle to be inferior to the target point. RESULTS: The distance between our target point and the inferior border of SLGN ranged from -3 mm to 6 mm. Twenty-three out of 25 (92%) SLGN lied exactly at or above our target intersection. The distance between our target point and the inferior border of SMGN ranged from -1 mm to 2 mm with twenty-two out of 25 (88%) SMGN lied exactly at or above our target point. The distance between our target point and the superior border of IMGN ranged from 0 mm to 3 mm with all (100%) IMGN lying exactly at or above the target point. CONCLUSION: The intersection of the femoral diaphyseal shaft to a line along the metaphyseal flare and the intersection of the tibial diaphyseal shaft to a line along the medial metaphyseal can be used as a target point to localize the genicular nerves with close proximity.


Assuntos
Articulação do Joelho/inervação , Bloqueio Nervoso/métodos , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Feminino , Fêmur/inervação , Humanos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tíbia/inervação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA