Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 25(6): 1153-1160, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31107211

RESUMO

Reliable serologic tests are needed for diagnosis and surveillance of Zika virus infection. We evaluated the Euroimmun and Dia.Pro serologic tests for detection of Zika virus IgM and IgG by using a panel of 199 samples from a region endemic for flaviviruses. Kinetics of Zika virus antibodies were monitored from 300 sequential specimens sampled over a period of 10 months after infection. We observed suboptimal performance; sensitivity for Zika virus IgM was low, especially in the Euroimmun assay (49%), whereas IgM could be detected for months with the Dia.pro assay. The specificity of the Zika virus IgG assays was also low, especially that of Dia.Pro (62%); findings were strongly influenced by the epidemiologic context. These results highlight the complexity of serologic diagnosis of Zika virus infection in regions endemic for flaviviruses. Accurate analysis of the performance of assays is required to adapt and interpret algorithms.


Assuntos
Kit de Reagentes para Diagnóstico , Testes Sorológicos , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/virologia , Zika virus/classificação , Adolescente , Adulto , Idoso , Anticorpos Antivirais/imunologia , Criança , Pré-Escolar , Reações Cruzadas , Feminino , Humanos , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Lactente , Masculino , Pessoa de Meia-Idade , Kit de Reagentes para Diagnóstico/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Testes Sorológicos/normas , Fatores de Tempo , Adulto Jovem , Zika virus/imunologia , Infecção por Zika virus/imunologia
2.
Emerg Infect Dis ; 24(9): 1734-1736, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30124408

RESUMO

We report viral RNA loads and antibody responses in 6 severe human cases of Maripa virus infection (2 favorable outcomes) and monitored both measures during the 6-week course of disease in 1 nonfatal case. Further research is needed to determine prevalence of this virus and its effect on other hantaviruses.


Assuntos
Síndrome Pulmonar por Hantavirus/diagnóstico , Orthohantavírus/isolamento & purificação , Adulto , Idoso , Diagnóstico Diferencial , Guiana Francesa , Orthohantavírus/imunologia , Síndrome Pulmonar por Hantavirus/mortalidade , Síndrome Pulmonar por Hantavirus/virologia , Humanos , Masculino , Pessoa de Meia-Idade , RNA Viral/sangue , Carga Viral
4.
PLoS Negl Trop Dis ; 9(3): e0003596, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25803718

RESUMO

Considering the short lifetime of IgA antibodies in serum and the key advantages of antibody detection ELISAs in terms of sensitivity and specificity, Bio-Rad has just developed a new ELISA test based on the detection of specific anti-dengue IgA. This study has been carried out to assess the performance of this Platelia Dengue IgA Capture assay for dengue infection detection. A total of 184 well-characterized samples provided by the French Guiana NRC sera collection (Laboratory of Virology, Institut Pasteur in French Guiana) were selected among samples collected between 2002 and 2013 from patients exhibiting a dengue-like syndrome. A first group included 134 sera from confirmed dengue-infected patients, and a second included 50 sera from non-dengue infected patients, all collected between day 3 and day 15 after the onset of fever. Dengue infection diagnoses were all confirmed using reference assays by direct virological identification using RT-PCR or virus culture on acute sera samples or on paired acute-phase sera samples of selected convalescent sera. This study revealed: i) a good overall sensitivity and specificity of the IgA index test, i.e., 93% and 88% respectively, indicating its good correlation to acute dengue diagnosis; and ii) a good concordance with the Panbio IgM capture ELISA. Because of the shorter persistence of dengue virus-specific IgA than IgM, these results underlined the relevance of this new test, which could significantly improve dengue diagnosis accuracy, especially in countries where dengue virus is (hyper-) endemic. It would allow for additional refinement of dengue diagnostic strategy.


Assuntos
Vírus da Dengue/imunologia , Dengue/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina A/sangue , Adulto , Anticorpos Antivirais/sangue , Dengue/virologia , Feminino , Guiana Francesa , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
5.
J Clin Virol ; 71: 89-92, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26339948

RESUMO

BACKGROUND: The recent emergence of Chikungunya Virus (CHIKV) in the Americas constitutes a major public health problem on this continent, where the mosquito vector is widespread. The rapid diagnosis of suspected cases is essential for the monitoring and control of this ongoing outbreak. However, this requires reliable tools that are difficult to establish in areas without specialized laboratories. OBJECTIVES: The aim was to evaluate the performances of serum samples spotted onto filter paper for molecular and serological diagnosis of Chikungunya infection. STUDY DESIGN: Analyses were performed from frozen sera and serum spotted onto filter paper provided from 121 Chikungunya suspected cases collected at a biological laboratory on Saint-Martin Island. RESULTS: This approach performed well in comparisons with standard methods, with a sensitivity of 100% and a specificity of 93.6% for the combined technical approaches (RT-PCR and serological results). Comparisons of serum samples spotted onto filter paper and frozen samples showed a concordance rate of 94.8% in molecular tests and 98.2% in serological tests. CONCLUSIONS: This simple sampling technique could overcome the problems of the lack of efficient CHIKV diagnosis tools in remote regions, providing good results regardless of the molecular or serological approach used. This simple filter paper-based method can be used to diagnose both chikungunya and dengue infections, as previously demonstrated following transport at ambient temperature to specialized laboratories. Given the set-up costs and high performance of this method, it could be recommended for the monitoring and control of Chikungunya virus expansion in the Americas and in other affected regions.


Assuntos
Febre de Chikungunya/diagnóstico , Dessecação , Soro/virologia , Manejo de Espécimes/métodos , América , Humanos , Técnicas de Diagnóstico Molecular/métodos , Papel , Sensibilidade e Especificidade , Testes Sorológicos/métodos
6.
PLoS Negl Trop Dis ; 2(8): e280, 2008 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-18714359

RESUMO

BACKGROUND: We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). METHODS: We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. RESULTS: The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). CONCLUSION: Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.


Assuntos
Antígenos Virais/imunologia , Vírus da Dengue/imunologia , Dengue/diagnóstico , Dengue/virologia , Kit de Reagentes para Diagnóstico/normas , Proteínas não Estruturais Virais/imunologia , Vírus da Dengue/isolamento & purificação , Ensaio de Imunoadsorção Enzimática , Humanos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
7.
Am J Trop Med Hyg ; 79(5): 685-7, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18981504

RESUMO

During a dengue-3 outbreak in Paraguay at the beginning of 2007, capillary blood samples absorbed onto filter papers were collected from 44 suspected cases. These samples were subjected to three molecular and serologic tests, and 31 of the 44 samples gave a positive result by at least one of the techniques used. Molecular analyses detected the dengue-3 serotype in 22 patients and additionally the dengue-2 serotype in two patients. Therefore two different serotypes were co-circulating during this outbreak. Overall, this study validates the use of dried-blood samples for field screening investigations. Indeed, all types of laboratory studies of dengue were possible with samples consisting of a few drops of dried blood from finger pricks.


Assuntos
Vírus da Dengue/isolamento & purificação , Dengue/epidemiologia , Surtos de Doenças , Antígenos Virais/sangue , Dengue/sangue , Vírus da Dengue/classificação , Vírus da Dengue/genética , Vírus da Dengue/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Papel , Paraguai/epidemiologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa
8.
Clin Vaccine Immunol ; 13(11): 1185-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16988003

RESUMO

We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.


Assuntos
Antígenos Virais/sangue , Vírus da Dengue/imunologia , Dengue/sangue , Proteínas não Estruturais Virais/sangue , Adolescente , Adulto , Dengue/diagnóstico , Dengue/imunologia , Feminino , Humanos , Técnicas Imunoenzimáticas , Masculino , Pessoa de Meia-Idade
9.
J Clin Microbiol ; 43(11): 5784-6, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16272520

RESUMO

We used an enzyme-linked immunosorbent assay (ELISA) of immunoglobulin G avidity to determine the dengue immune status of 105 pairs of serum samples from patients infected with dengue virus. This study shows that a simple avidity test, for which only one acute-phase serum sample is required, is potentially more useful than the hemagglutination inhibition test for the discrimination of primary from secondary dengue virus infection, whatever the type of dengue antigen used.


Assuntos
Anticorpos Antivirais/imunologia , Vírus da Dengue/imunologia , Dengue/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina G/imunologia , Anticorpos Antivirais/sangue , Afinidade de Anticorpos , Antígenos Virais , Dengue/imunologia , Diagnóstico Diferencial , Humanos , Imunoglobulina G/sangue
10.
J Clin Microbiol ; 43(6): 2793-7, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15956399

RESUMO

For clinical and epidemiological purposes, it is necessary to be able to classify serological responses during dengue virus infection. Thus, it is important to develop a test that can distinguish between primary and secondary serological responses. The hemagglutination inhibition (HI) test, which is currently recommended by the World Health Organization, is complicated to perform. We developed an enzyme-linked immunosorbent assay based on changes in the avidity of immunoglobulin G during the infectious episode. This test can discriminate between primary and secondary infections by using a single serum sample collected during the acute phase of infection. We took 1,140 avidity measurements with 118 pairs of serum samples or sequential samples taken from patients classified as having primary or secondary infection according to World Health Organization laboratory criteria. The mean percent avidity was significantly lower during primary infection (25.9%) than during secondary infection (66.3%) (Student t test, P < 0.001). The test had a sensitivity of 82.7% (95% confidence interval [CI] = 79.0 to 86.6) and a specificity of 77.5% (95% CI = 73.3 to 81.7). Based on analysis of only blood samples collected between the third and seventh days of the illness, during which most clinical complications occur, the sensitivity and specificity of the test were 95.1% (95% CI = 92.6 to 97.7) and 80.0% (95% CI = 75.3 to 84.7), respectively. This rapid and simple test appears to be an excellent alternative to the HI test for discriminating between primary and secondary dengue virus infections during the acute phase of dengue.


Assuntos
Anticorpos Antivirais/imunologia , Afinidade de Anticorpos , Vírus da Dengue/imunologia , Dengue/diagnóstico , Imunoglobulina G/imunologia , Doença Aguda , Anticorpos Antivirais/sangue , Doença Crônica , Dengue/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA