EJNMMI Phys ; 9(1): 54, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35976503

RESUMO

BACKGROUND: Dead-time correction is required for accurate quantitative SPECT-based dosimetry in the context of personalised 177Lu radiopharmaceutical therapy. We aimed to evaluate the impact of applying dead-time correction on the reconstructed SPECT image versus on the acquisition projections before reconstruction. METHODS: Data from 16 SPECT/CT acquisitions of a decaying 177Lu-filled phantom (up to 20.75 GBq) and dual-timepoint SPECT/CT in 14 patients treated with personalised 177Lu peptide receptor radionuclide therapy were analysed. Dead time was determined based on the acquisition wide-spectrum count rate for each projection and averaged for the entire acquisition. Three dead-time correction methods (DTCMs) were used: the per-projection correction, where each projection was individually corrected before reconstruction (DTCM1, the standard of reference), and two per-volume methods using the average dead-time correction factor of the acquisition applied to all projections before reconstruction (DTCM2) or to the SPECT image after reconstruction (DTCM3). Relative differences in quantification were assessed for various volumes of interest (VOIs) on the phantom and patient SPECT images. In patients, the resulting dosimetry estimates for tissues of interest were also compared between DTCMs. RESULTS: Both per-volume DTCMs (DTCM2 and DTCM3) were found to be equivalent, with VOI count differences not exceeding 0.8%. When comparing the per-volume post-reconstruction DTCM3 versus the per-projection pre-reconstruction DTCM1, differences in VOI counts and absorbed dose estimates did not exceed 2%, with very few exceptions. The largest absorbed dose deviation was observed for a kidney at 3.5%. CONCLUSION: While per-projection dead-time correction appears ideal for QSPECT, post-reconstruction correction is an acceptable alternative that is more practical to implement in the clinics, and that results in minimal deviations in quantitative accuracy and dosimetry estimates, as compared to the per-projection correction.

2.
EJNMMI Phys ; 8(1): 73, 2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34718900

RESUMO

BACKGROUND: Accurate QSPECT is crucial in dosimetry-based, personalized radiopharmaceutical therapy with 177Lu and other radionuclides. We compared the quantitative performance of three NaI(Tl)-crystal SPECT/CT systems equipped with low-energy high-resolution collimators from two vendors (Siemens Symbia T6; GE Discovery 670 and NM/CT 870 DR). METHODS: Using up to 14 GBq of 99mTc in planar mode, we determined the calibration factor and dead-time constant under the assumption that these systems have a paralyzable behaviour. We monitored their response when one or both detectors were activated. QSPECT capability was validated by SPECT/CT imaging of a customized NEMA phantom containing up to 17 GBq of 99mTc. Acquisitions were reconstructed with a third-party ordered subset expectation maximization algorithm. RESULTS: The Siemens system had a higher calibration factor (100.0 cps/MBq) and a lower dead-time constant (0.49 µs) than those from GE (75.4-87.5 cps/MBq; 1.74 µs). Activities of up to 3.3 vs. 2.3-2.7 GBq, respectively, were quantifiable by QSPECT before the observed count rate plateaued or decreased. When used in single-detector mode, the QSPECT capability of the former system increased to 5.1 GBq, whereas that of the latter two systems remained independent of the detectors activation mode. CONCLUSION: Despite similar hardware, SPECT/CT systems' response can significantly differ at high count rate, which impacts their QSPECT capability in a post-therapeutic setting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA