Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 24(2): 44, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39077410

RESUMO

Background: Prevention of stroke by anticoagulation is essential in patients with Atrial fibrillation (AF); with direct oral anticoagulants (DOACs) being preferred over warfarin in most patients. The Long-term efficacy and safety of DOACs vs. Left Atrial Appendage Occlusion (LAAO) remain unknown. Methods: Electronic databases (PubMed, Embase, Scopus) were searched from inception to February 10th, 2021. The primary endpoint was cardiovascular mortality. Secondary outcomes included incidence of ischemic stroke/transient ischemic attack (TIA) and systemicembolism. The safety endpoint was clinically relevant bleeding (a composite of major or minor clinically relevant bleeding). Results: A total of three studies with 3039 participants (LAAO = 1465; DOACs = 1574) were included. Mean age was 74.2 and 75.3 years in the LAAO and DOAC group respectively. Average follow-up period was 2 years. There was no difference in terms of cardiac mortality (RR 0.90, 95% CI 0.40-2.03; p = 0.81), ischemic stroke/TIA (RR 1.15, 95% CI 0.80-1.65; p = 0.46; I 2 = 0) and clinically significant bleeding (RR 0.77, 95% CI 0.50-1.17; p = 0.22; I 2 = 69) between the groups. Conclusions: Among patients with AF, LAAO was comparable to DOACs with similar efficacy and safety profiles.

2.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378620

RESUMO

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Arritmias Cardíacas , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
3.
Rev Cardiovasc Med ; 23(3): 112, 2022 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-35345279

RESUMO

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF), primarily performed in patients who fail antiarrhythmic drugs. Whether early catheter ablation, as first-line therapy, is associated with improved clinical outcomes remains unclear. METHODS: Electronic databases (PubMed, Scopus, Embase) were searched until March 28th, 2021. Randomized controlled trials (RCTs) compared catheter ablation vs antiarrhythmic drug therapy as first-line therapy were included. The primary outcome of interest was the first documented recurrence of any atrial tachyarrhythmia (symptomatic or asymptomatic; AF, atrial flutter, and atrial tachycardia). Secondary outcomes included symptomatic atrial tachyarrhythmia (AF, atrial flutter, and atrial tachycardia) and serious adverse events. Unadjusted risk ratios (RR) were calculated from dichotomous data using Mantel Haenszel (M-H) random-effects with statistical significance considered if the confidence interval (CI) excludes one and p < 0.05. RESULTS: A total of six RCTs with 1212 patients (Ablation n = 609; Antiarrhythmic n = 603) were included. Follow- up period ranged from 1-2 years. Patients who underwent ablation were less likely to experience any recurrent atrial tachyarrhythmia when compared to patients receiving antiarrhythmic drugs (RR 0.63; 95% CI 0.55-0.73; p < 0.00001). Symptomatic atrial tachyarrhythmia was also lower in the ablation arm (RR 0.53; 95% CI 0.32-0.87; p = 0.01). No statistically significant differences were noted for overall any type of adverse events (RR 0.93; 95% CI 0.68-1.27; p = 0.64) and cardiovascular adverse events (RR 0.90; 95% CI 0.56-1.44; p = 0.65) respectively. CONCLUSIONS: Catheter ablation, as first-line therapy, was associated with a significantly lower rate of tachyarrhythmia recurrence compared to conventional antiarrhythmic drugs, with a similar adverse effect risk profile. These findings support a catheter ablation strategy as first-line therapy among patients with symptomatic paroxysmal atrial fibrillation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Flutter Atrial/tratamento farmacológico , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Recidiva , Taquicardia/tratamento farmacológico , Taquicardia/etiologia , Taquicardia/cirurgia , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 100(4): 575-584, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36073017

RESUMO

BACKGROUND: Measures were undertaken at the Cleveland Clinic to reduce radiation exposure to patients and personnel working in the catheterization laboratories. We report our experience with these improved systems over a 7-year period in patients undergoing diagnostic catheterization (DC) and percutaneous coronary interventions (PCIs). METHODS: Patients were categorized into preinitiative (2009-2012) and postinitiative (2013-2019) groups in the DC and PCI cohorts. Propensity score matching was done between the pre- and postinitiative groups for both cohorts based on age, sex, body surface area, total fluoroscopy time, and total acquisition time. The effectiveness of radiation reduction measures was assessed by comparing the total air kerma (Ka,r ), and fluoroscopy- and acquisition-mode air kerma in patients in the two groups. RESULTS: In the DC cohort, there was a significant reduction in Ka,r in the postinitiative group in comparison to the preinitiative group (median, 396 vs. 857 mGy; p < 0.001). In the PCI cohort, Ka,r in the postinitiative group was 1265 mGy, which was significantly lower than the corresponding values in the preinitiative group (1994 mGy; p < 0.001). We also observed a significant reduction in fluoroscopy- and acquisition-based air kerma rates, and air kerma area product in the postinitiative group in comparison to the preinitiative group in both matched and unmatched DC and PCI cohorts after the institution of radiation reduction measures. CONCLUSION: There was a significant and sustained reduction in radiation exposure to patients in the catheterization laboratory with the implementation of advanced protocols. Similar algorithms can be applied in other laboratories to achieve a similar reduction in radiation exposure.


Assuntos
Intervenção Coronária Percutânea , Exposição à Radiação , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Fluoroscopia/efeitos adversos , Fluoroscopia/métodos , Humanos , Laboratórios , Intervenção Coronária Percutânea/efeitos adversos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3379-3388, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35491368

RESUMO

Adult congenital heart disease (ACHD) is a rising concern for the current healthcare system, with a prevalence that is anticipated to steadily increase through the year 2050. It is estimated that there are >1.4 million adults in the United States living with a congenital heart defect. Despite significant advances in medical and surgical therapy, most of these patients progress to advanced heart failure due to the unique anatomic, physiological, and hemodynamic abnormalities associated with the disease. Patient awareness of the disease coupled with advances in the diagnosis and treatment has led to a significant increase in the surgical treatment of CHD in adults. The authors aim to summarize and critically appraise the current literature on the morbidity, mortality, and risk scores associated with ACHD.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Adulto , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/cirurgia , Humanos , Morbidade , Medição de Risco , Fatores de Risco , Estados Unidos
6.
Rev Cardiovasc Med ; 22(4): 1095-1113, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957756

RESUMO

Artificial Intelligence (AI) performs human intelligence-dependant tasks using tools such as Machine Learning, and its subtype Deep Learning. AI has incorporated itself in the field of cardiovascular medicine, and increasingly employed to revolutionize diagnosis, treatment, risk prediction, clinical care, and drug discovery. Heart failure has a high prevalence, and mortality rate following hospitalization being 10.4% at 30-days, 22% at 1-year, and 42.3% at 5-years. Early detection of heart failure is of vital importance in shaping the medical, and surgical interventions specific to HF patients. This has been accomplished with the advent of Neural Network (NN) model, the accuracy of which has proven to be 85%. AI can be of tremendous help in analyzing raw image data from cardiac imaging techniques (such as echocardiography, computed tomography, cardiac MRI amongst others) and electrocardiogram recordings through incorporation of an algorithm. The use of decision trees by Rough Sets (RS), and logistic regression (LR) methods utilized to construct decision-making model to diagnose congestive heart failure, and role of AI in early detection of future mortality and destabilization episodes has played a vital role in optimizing cardiovascular disease outcomes. The review highlights the major achievements of AI in recent years that has radically changed nearly all areas of HF prevention, diagnosis, and management.


Assuntos
Inteligência Artificial , Insuficiência Cardíaca , Algoritmos , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Aprendizado de Máquina
7.
Rev Cardiovasc Med ; 22(1): 83-95, 2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33792250

RESUMO

The coronavirus disease-19 (COVID-19) pandemic has forced hospitals to prioritize COVID-19 patients, restrict resources, and cancel all non-urgent elective cardiac procedures. Clinical visits have only been facilitated for emergency purposes. Fewer patients have been admitted to the hospital for both ST-segment elevation myocardial infarctions (STEMI) and non-ST segment elevation myocardial infarctions (NSTEMI) and a profound decrease in heart failure services has been reported. A similar reduction in the patient presentation is seen for ischemic heart disease, decompensated heart failure, and endocarditis. Cardiovascular services, including catheterization, primary percutaneous coronary intervention (PPCI), cardiac investigations such as electrocardiograms (ECGs), exercise tolerance test (ETT), dobutamine stress test, computed tomography (CT) angiography, transesophageal echocardiography (TOE) have been reported to have declined and performed on a priority basis. The long-term implications of this decline have been discussed with major concerns of severe cardiac complications and vulnerabilities in cardiac patients. The pandemic has also had psychological impacts on patients causing them to avoid seeking medical help. This review discusses the effects of the COVID-19 pandemic on the provision of various cardiology services and aims to provide strategies to restore cardiovascular services including structural changes in the hospital to make up for the reduced staff personnel, the use of personal protective equipment in healthcare workers, and provides alternatives for high-risk cardiac imaging, cardiac interventions, and procedures. Implementation of the triage system, risk assessment scores, and telemedicine services in patients and their adaptation to the cardiovascular department have been discussed.


Assuntos
COVID-19/epidemiologia , Cardiologia/organização & administração , Atenção à Saúde/organização & administração , Controle de Infecções/organização & administração , COVID-19/prevenção & controle , COVID-19/transmissão , Procedimentos Cirúrgicos Cardiovasculares , Humanos , Telemedicina , Triagem
8.
Catheter Cardiovasc Interv ; 98(1): E127-E138, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33010100

RESUMO

BACKGROUND: Baseline conduction abnormalities are known risk factors for permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR). We sought to determine the impact of baseline right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior hemiblock (LAHB), first-degree atrioventricular block (AVB) and atrial fibrillation/flutter (AF) on TAVR outcomes. METHODS: Consecutive patients who underwent transfemoral TAVR with SAPIEN-3 (S3) were included. We excluded patients with prior PPM, nontransfemoral access or valve-in-valve. RESULTS: Among 886 patients, baseline RBBB was seen in 15.9%, LBBB in 6.3%, LAHB in 6.2%, first-degree AVB in 26.3% and AF in 37.5%. The rate of 30-day PPM was 10.1%. Baseline RBBB (OR 4.005; 95% CI 2.386-6.723; p < .001) and first-degree AVB (OR 1.847; 95% CI 1.133-3.009; p = .014) were independent predictors of 30 day PPM. LAHB also resulted in higher PPM rates but only in unadjusted analysis (21.8% vs. 9.4%; p = .003). Baseline LBBB and AF were associated with lower left ventricular ejection fraction (LVEF) at both baseline and 1 year after TAVR. However, Δ LVEF over time were noted to be similar with baseline LBBB (1.8% vs. 1.4%; p = .809) and AF (1.1% vs. 1.7%; p = .458). Moreover, baseline AF was also associated with higher stroke/transient ischemic attack (TIA) at 1 year (4.4% vs. 1.8%; p = .019), 1-year major adverse cardiac and cerebrovascular events (MACCE) (19.5% vs. 13.3%; p = .012) and 2 year mortality (23.5% vs. 15.2%; p = .016). None of the other baseline conduction defects affected long-term mortality or MACCE. CONCLUSION: In our S3 TAVR population, baseline RBBB and first-degree AVB predicted higher PPM risk. Prior LBBB and AF were associated with lower LVEF at both baseline and 1 year. Lastly, preexisting AF was associated with higher rates of mortality, stroke/TIA, and MACCE.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
9.
Catheter Cardiovasc Interv ; 98(3): E436-E443, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33512085

RESUMO

BACKGROUND: Monitored anesthesia care (MAC) has become more widely used during transcatheter aortic valve replacement (TAVR) to avoid the complications of general anesthesia (GA). METHODS: We included consecutive patients who underwent transfemoral-TAVR at our institution between January 2012 and April 2017. We compared outcomes with GA versus MAC. RESULTS: Of 998 patients, MAC was used in 43.9%. MAC was associated with shorter procedural time (96.9 ± 30.9 vs. 135 ± 64.6 mins; p < .001), fluoroscopy time (20.4 ± 8.9 vs. 29 ± 18.7 mins; p < .001), lower contrast volume (45.5 ± 27 vs. 60.4 ± 43 cc; p < .001), and decreased radiation exposure (12,869 ± 8,099 vs. 20,630 ± 16,276 cGy-cm2 ; p < .001). Patients who underwent MAC had a briefer median (IQR) intensive care unit stay [23.3 (21-24) vs. 23.4 (20.8-26) hrs; p < .001], and hospital stay [2 (2, 3) vs. 3 (2-6) days; p < .001], and were more frequently discharged to home (93.4% vs. 82.9%; p < .001). MAC was associated with lower mortality at 30 days (0.5% vs. 2.9%; log-rank p = .012; adjHR 0.22, 95% CI 0.06-0.82; p = .024), but not at 1 year (11.7% vs. 14.6%; log-rank p = .157) or 3 years (36.8% vs. 38.4%; log-rank p = 0.433). There were no differences in major adverse cardiac and cerebrovascular events (MACCE) at either 30 days (4.6% vs. 9.3%; log-rank p = .14) or 1 year (21.1% vs. 21.5%; log-rank p = .653). Similar findings were seen among patients who received newer-generation SAPIEN-3 valves. CONCLUSION: Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Tempo de Internação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Echocardiography ; 38(6): 1077-1080, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33929773

RESUMO

The presence of human coronavirus HKU1 infection associated with pericardial inflammation is not reported. We are reporting a young woman with systemic lupus erythematosus, who was positive for HKU1 during her pericarditis flare. Diagnostic imaging demonstrated pericardial effusion, edema, and late gadolinium enhancement on cardiac magnetic resonance imaging and echocardiography. She was on multiple anti-inflammatory medications and achieved remission with anakinra. Her management and a brief literature review is also presented.


Assuntos
Coronavirus , Lúpus Eritematoso Sistêmico , Pericardite , Meios de Contraste , Feminino , Gadolínio , Humanos , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Pericardite/complicações , Pericardite/diagnóstico
11.
Cardiology ; 145(9): 601-607, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32653884

RESUMO

Coronary subclavian steal syndrome (CSSS) is a rare cause of angina. It occurs in patients with prior coronary artery bypass grafting and, specifically, a left internal mammary artery (LIMA) to left anterior descending artery (LAD) graft and co-existent significant subclavian artery stenosis. In this context, there is retrograde blood flow through the LIMA to LAD graft to supply the subclavian artery beyond the significant stenosis. This potentially occurs at the cost of compromising coronary artery perfusion dependent on the LIMA graft. In this review, we present a case of a middle-aged female who suffered from CSSS and review the literature for the contemporary diagnosis and management of this condition.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Síndrome do Roubo Coronário-Subclávio/etiologia , Anastomose de Artéria Torácica Interna-Coronária/efeitos adversos , Síndrome do Roubo Subclávio/complicações , Angina Pectoris/etiologia , Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana/cirurgia , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade
12.
Echocardiography ; 37(8): 1300-1303, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32648315

RESUMO

Pericardial cysts are considered rare incidental findings, which are generally asymptomatic in nature. Occasionally, patients may represent with chest discomfort, dyspnea, or palpitations. Pericarditis related to a ruptured pericardial cyst has not been previously reported in the literature. Here, we report the case of a 62-year-old man who developed acute pericarditis as a result of a ruptured enlarging pericardial cyst.


Assuntos
Cisto Mediastínico , Pericardite , Humanos , Masculino , Cisto Mediastínico/complicações , Cisto Mediastínico/diagnóstico por imagem , Pessoa de Meia-Idade , Pericardite/complicações , Pericardite/diagnóstico por imagem , Pericárdio , Doenças Raras , Tomografia Computadorizada por Raios X
15.
Am J Cardiol ; 201: 123-130, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37385163

RESUMO

There is a paucity of data on the prognostic impact of mitral annular calcification (MAC) in patients who underwent transcatheter aortic valve implantation (TAVI) with conflicting results being reported by the studies that are published. Therefore, we performed a meta-analysis to assess the short-term and long-term outcomes of MAC in patients after TAVI. Of 25,407 studies identified after the initial database search, 4 observational studies comprising 2,620 patients (2,030 patients in the nonsevere MAC arm and 590 patients in the severe MAC arm) were included in the final analysis. Compared with patients with nonsevere MAC, the severe MAC group was associated with significantly higher incidences of overall bleeding (0.75 [0.57 to 0.98], p = 0.03, I2 = 0%) at 30 days. However, no significant difference was observed between the 2 groups for the rest of the 30-day outcomes: all-cause mortality (0.79 [0.42 to 1.48], p = 0.46, I2 = 9%), myocardial infarction (1.62 [0.37 to 7.04], p = 0.52, I2 = 0%), cerebrovascular accident or stroke (1.22 [0.53 to 2.83], p = 0.64, I2 = 0%), acute kidney injury (1.48 [0.64 to 3.42], p = 0.35, I2 = 0%), and pacemaker implantation (0.70 [0.39 to 1.25], p = 0.23, I2 = 68%). Similarly, follow-up outcomes also showed no significant difference between the 2 groups: all-cause mortality (0.69 [0.46 to 1.03], p = 0.07, I2 = 44%), cardiovascular mortality (0.52 [0.24 to 1.13], p = 0.10, I2 = 70%) and stroke (0.83 [0.41 to 1.69], p = 0.61, I2 = 22%). The sensitivity analysis, however, demonstrated significant results for all-cause mortality (0.57 [0.39 to 0.84], p = 0.005, I2 = 7%) by removing the study by Okuno et al5 and cardiovascular mortality (0.41 [0.21 to 0.82], p = 0.01, I2 = 66%) by removing the study by Lak et al.7 In conclusion, our meta-analysis corroborates the notion that isolated MAC is not an independent predictor of long-term mortality after TAVI and determines severe MAC to be a predictor of mortality at follow-up because of the higher incidence of mitral valve dysfunction associated with it.


Assuntos
Estenose da Valva Aórtica , Calcinose , Cardiopatias Congênitas , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Prevalência , Doenças das Valvas Cardíacas/complicações , Calcinose/complicações , Calcinose/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Cardiopatias Congênitas/complicações , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos
16.
Am J Cardiol ; 197: 24-33, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37137251

RESUMO

Data regarding the impact of pacing on outcomes after transcatheter aortic valve implantation (TAVI) is evolving especially with regards to pre-existing permanent pacemaker (PPM). We examined the impact of new and previous PPM on the clinical and hemodynamic outcomes after SAPIEN-3 TAVI. We included all consecutive patients who underwent transfemoral TAVI using SAPIEN-3 valve from 2015 to 2018 at our institution. Among 1,028 patients, 10.2% required a new PPM within 30 days, whereas 14% had a pre-existing PPM. The presence of either previous or new PPM had no impact on the 3-year mortality (log-rank p = 0.6) or 1-year major adverse cardiac and cerebrovascular events (log-rank p = 0.65). New PPM was associated with lower left ventricular (LV) ejection fraction (LVEF) at both 30 days (54.4 ± 11.3% vs 58.4 ± 10.1%, p = 0.001) and 1 year (54.2 ± 12% vs 59.1 ± 9.9%, p = 0.009) than no PPM. Similarly, previous PPM was associated with worse LVEF at 30 days (53.6 ± 12.3%, p <0.001) and 1 year (55.5 ± 12.1%, p = 0.006) than no PPM. Interestingly, new PPM was associated with lower 1-year mean gradient (11.4 ± 3.8 vs 12.6 ± 5.6 mm Hg, p = 0.04) and peak gradient (21.3 ± 6.5 vs 24.1 ± 10.4 mm Hg, p = 0.01), despite no baseline differences. Previous PPM was also associated with lower 1-year mean gradient (10.3 ± 4.4 mm Hg, p = 0.001) and peak gradient (19.4 ± 8 mm Hg, p <0.001) and higher Doppler velocity index (0.51 ± 0.12 vs 0.47 ± 0.13, p = 0.039). Moreover, 1-year LV end-systolic volume index was higher with new (23.2 ± 16.1 vs 20 ± 10.8 ml/m2, p = 0.038) and previous PPM (24.5 ± 19.7, p = 0.038) than no PPM. Previous PPM was associated with higher moderate-to-severe tricuspid regurgitation (35.3% vs 17.7%, p <0.001). There were no differences regarding the rest of the studied echocardiographic outcomes at 1 year. In conclusion, new and previous PPM did not affect 3-year mortality or 1-year major adverse cardiac and cerebrovascular events; however, they were associated with worse LVEF, higher 1-year LV end-systolic volume index, and lower mean and peak gradients on follow-up than no PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Ecocardiografia , Função Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
17.
Transplant Proc ; 54(3): 663-670, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35256200

RESUMO

BACKGROUND: Cardiovascular disease is the most common cause of death among kidney transplant (KT) recipients. Trials routinely exclude patients with end-stage renal disease when assessing the effect of coronary artery revascularization. We looked to compare long-term outcomes in patients who underwent percutaneous coronary intervention (PCI) before KT with those managed medically. METHODS: We identified all patients who underwent coronary artery catheterization before KT from January 2008 to November 2019 at the Cleveland Clinic. The primary endpoint was all-cause mortality. RESULTS: A total of 272 patients were included, of whom 52 (19.11%) underwent PCI, and the remaining 220 patients were managed medically. The median age in the PCI group was 57.4 years (interquartile range [IQR], 46.9-61.2 years), whereas it was 53.9 years (IQR, 44.6-61 years) in the group medically managed. Baseline characteristics including sex, race, hypertension, diabetes, smoking, and hyperlipidemia were comparable in both groups. The median time to KT was 2.4 years (IQR, 1-5 years) in the PCI group vs 1.2 years (IQR, 0.6-3.3 years) in the medically managed group (P = .001). Among patients who underwent PCI, 40.4% had single vessel disease and 59.6% had multivessel disease compared with 16.8% and 28.6%, respectively, in the medically managed group (P < .001). Overall, there was no difference in mortality in the PCI group compared with the medically managed group after 10 years of follow-up (P = .416). CONCLUSIONS: Patients with coronary artery disease can be safely treated with PCI before KT and have comparable outcomes to those who are managed medically.


Assuntos
Doença da Artéria Coronariana , Transplante de Rim , Intervenção Coronária Percutânea , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/etiologia , Humanos , Transplante de Rim/efeitos adversos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Fatores de Risco , Resultado do Tratamento
18.
Am J Cardiol ; 170: 31-39, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35248389

RESUMO

Data comparing outcomes of distal radial (DR) and traditional radial (TR) access of coronary angiography and percutaneous coronary intervention (PCI) are limited. Online databases including Medline and Cochrane Central databases were explored to identify studies that compared DR and TR access for PCI. The primary outcome was the rate of radial artery occlusion (RAO) and access failure. Secondary outcomes included access site hematoma, access site bleeding, access site pain, radial artery spasm, radial artery dissection, and crossover. Unadjusted odds ratios (ORs) with a random-effect model, 95% confidence interval (CI), and p <0.05 were used for statistical significance. Metaregression was performed for 16 studies with 9,973 (DR 4,750 and TR 5,523) patients were included. Compared with TR, DR was associated with lower risk of RAO (OR 0.51, 95% CI 0.29 to 0.90, I2 = 42.6%, p = 0.02). RAO was lower in DR undergoing coronary angiography rather than PCI. Access failure rate (OR 1.77, 95% CI 0.69 to 4.55, I2 87.36%, p = 0.24), access site hematoma (OR 1.11, 95% CI 0.68 to 1.83, I2 0%, p = 0.68), access site pain (OR 2.22, 95% CI 0.28 to 17.38, I2 0%, p = 0.45), access site bleeding (OR 1.11, 95% CI 0.16 to 7.62, I2 85.11%, p = 0.91), radial artery spasm (OR 0.79, 95% CI 0.49 to 1.29, I2 0%, p = 0.35), radial artery dissection (OR 1.63, 95% CI 0.46 to 5.84, I2 0%, p = 0.45), and crossover (OR 1.54, 95% CI 0.64 to 3.70, I2 25.48%, p = 0.33) did not show any significant difference. DR was associated with lower incidence RAO when compared with TR, whereas other procedural-related complications were similar.


Assuntos
Arteriopatias Oclusivas , Cateterismo Periférico , Intervenção Coronária Percutânea , Arteriopatias Oclusivas/etiologia , Cateterismo Periférico/efeitos adversos , Angiografia Coronária/efeitos adversos , Artéria Femoral , Hematoma/epidemiologia , Hematoma/etiologia , Hemorragia/complicações , Humanos , Dor/complicações , Intervenção Coronária Percutânea/efeitos adversos , Artéria Radial , Fatores de Risco , Espasmo/complicações , Resultado do Tratamento
19.
Int J Cardiol Heart Vasc ; 43: 101151, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36411872

RESUMO

Introduction: Coronavirus Disease 2019 (COVID-19) has been associated with an increased risk of adverse cardiovascular events including arteriovenous thrombosis, myocarditis and acute myocardial injury. Relevant literature to date has reported widely varying estimates of mortality, ranging from approximately 2 to 11 times higher odds of mortality in COVID-19-positive STEMI (ST-segment elevation myocardial infarction) patients. Hence, we conducted this meta-analysis to resolve these inconsistencies and assess the impact of COVID-19 infection on mortality and other clinical outcomes in patients presenting with STEMI. Methods: This meta-analysis was registered in PROSPERO (CRD42021297458) and performed according to the Cochrane Handbook for Systematic Reviews of Interventions. PubMed and Embase were searched from inception to November 2021 (updated on April 2022) using a search strategy consisting of terms relating to COVID-19, STEMI, and mortality. Results: We identified 435 studies through our initial search. After screening according to our eligibility criteria, a total of 11 studies were included. Compared with the non-COVID-19 STEMI patients, the in-hospital mortality rate was higher in COVID-19-positive STEMI patients. Similarly, the risk of cardiogenic shock was higher in the COVID-19-positive patients. Length of hospital stay was longer in STEMI patients with COVID-19. Conclusions: Our study highlights the necessity for early evaluation of COVID-19 status in all STEMI patients followed by risk stratification, prompt reperfusion and more aggressive management of COVID-19-positive patients. Further research is needed to elucidate the mechanisms behind poorer prognosis in such patients.

20.
Open Heart ; 9(1)2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35728890

RESUMO

BACKGROUND: Increase in left ventricular filling pressure (FP) and diastolic dysfunction are established consequences of progressive aortic stenosis (AS). However, the impact of elevated FP as detected by pretranscatheter aortic valve replacement (TAVR) echocardiogram on long-term outcomes after TAVR remains unclear. OBJECTIVE: To understand the impact of elevated FP in patients with severe AS who undergo TAVR. METHODS: This was a retrospective study of all patients who underwent TAVR between 1 January 2014 and 31 December 2017. The presence of elevated FP was determined in accordance with the latest guidelines using the last available comprehensive echocardiogram prior to TAVR. RESULTS: Of 983 patients who were included in our study, 422 patients (43%) were found to have elevated FP and 561 patients (57%) had normal FP prior to TAVR. Patients with elevated FP had a mean age of 81.2±8.6 years and were more likely to be males (62%), diabetic (41% vs 35%, p=0.046), and have a higher prevalence of atrial fibrillation (Afib) (53% vs 39%, p<0.001). The 5-year all-cause mortality after TAVR was significantly higher in patients with elevated FP when compared with patients with normal FP (32% vs 24%, p=0.006). The presence of elevated FP, history of Afib and prior PCI emerged as independent predictors of long-term mortality after TAVR. CONCLUSION: Elevated FP is associated with increased mortality in patients with severe AS undergoing TAVR. Assessment of FP should be incorporated into the risk assessment of AS patients to identify those who may benefit from early intervention.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA