Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967787

RESUMO

The need for urgent or emergent cardiovascular imaging in children is rare when compared to adults. Patients may present from the neonatal period up to adolescence, and may require imaging for both traumatic and non-traumatic causes. In children, coronary pathology is rarely the cause of an emergency unlike in adults where it is the main cause. Radiology, including chest radiography and computed tomography in conjunction with echocardiography, often plays the most important role in the acute management of these patients. Magnetic resonance imaging can occasionally be useful and may be suitable in more subacute cases. Radiologists' knowledge of how to manage and interpret these acute conditions including knowing which imaging technique to use is fundamental to appropriate care. In this review, we will concentrate on the most common cardiovascular emergencies in the thoracic region, including thoracic traumatic and non-traumatic emergencies and pulmonary vascular emergencies, as well as acute clinical disorders as a consequence of primary and postoperative congenital heart disease. This review will cover situations where cardiovascular imaging may be acutely needed, and not strictly emergencies only. Imaging recommendations will be discussed according to the different clinical presentations and underlying pathology.

2.
Pediatr Radiol ; 54(2): 260-268, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37985493

RESUMO

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment in end-stage liver disease. Imaging is a key element for successful organ-transplantation to assist surgical planning. So far, only limited data regarding the best radiological approach to prepare children for liver transplantation is available. OBJECTIVES: In an attempt to harmonize imaging surrounding pediatric liver transplantation, the European Society of Pediatric Radiology (ESPR) Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra-, and postoperative phase. This paper reports the responses on preoperative imaging. MATERIAL AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted and 22 institutions from 11 countries returned the survey. From 2018 to 2020, the participating centers collectively conducted 1,524 transplantations, with a median of 20 transplantations per center per annum (range, 8-60). RESULTS: Most sites (64%) consider ultrasound their preferred modality to define anatomy and to plan surgery in children before liver transplantation, and additional cross-sectional imaging is only used to answer specific questions (computed tomography [CT], 90.9%; magnetic resonance imaging [MRI], 54.5%). One-third of centers (31.8%) rely primarily on CT for pre-transplant evaluation. Imaging protocols differed substantially regarding applied CT scan ranges, number of contrast phases (range 1-4 phases), and applied MRI techniques. CONCLUSION: Diagnostic imaging is generally used in the work-up of children before liver transplantation. Substantial differences were noted regarding choice of modalities and protocols. We have identified starting points for future optimization and harmonization of the imaging approach to multicenter studies.


Assuntos
Transplante de Fígado , Radiologia , Criança , Humanos , Ultrassonografia , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética/métodos
3.
Pediatr Radiol ; 54(2): 269-275, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38216682

RESUMO

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of intraoperative and postoperative complications. So far, only limited data regarding the best radiological approach to monitor children during liver transplantation is available. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra- and postoperative phase. This paper reports the responses related to intraoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: Intraoperative ultrasound (US) is used by all sites to assess the quality of the vascular anastomosis in order to ensure optimal perfusion of the liver transplant. Vessel depiction is commonly achieved using color Doppler (95.3%). Additional US-based techniques are employed by fewer centers (power angio mode, 28.6%; B-flow, 19%; contrast-enhanced US, 14.3%). Most centers prefer a collaborative approach, with surgeons responsible for probe handling, while radiologists operate the US machine (47.6%). Less commonly, the intraoperative US is performed by the surgeon alone (28.6%) or by the radiologist alone (23.8%). Timing of US, imaging frequency, and documentation practices vary among centers. CONCLUSION: Intraoperative US is consistently utilized across all sites during pediatric liver transplantation. However, considerable variations were observed in terms of the US setup, technique preferences, timing of controls, and documentation practices. These differences provide valuable insights for future optimization and harmonization studies.


Assuntos
Transplante de Fígado , Radiologia , Criança , Humanos , Ultrassonografia , Radiografia , Complicações Pós-Operatórias/diagnóstico por imagem
4.
Pediatr Radiol ; 54(2): 276-284, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38285190

RESUMO

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of postoperative complications. So far, limited data is available regarding the best radiologic approach to monitor children after liver transplantation. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra-, and postoperative phases. This paper reports the responses related to postoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: All sites commence ultrasound (US) monitoring within 24 h after liver transplantation. Monitoring frequency varies across sites, ranging from every 8 h to 72 h in early, and from daily to sporadic use in late postoperative phases. Predefined US protocols are used by 73% of sites. This commonly includes gray scale, color Doppler, and quantitative flow assessment. Alternative flow imaging techniques, contrast-enhanced US, and elastography are applied at 31.8%, 18.2%, and 63.6% of sites, respectively. Computed tomography is performed at 86.4% of sites when clarification is needed. Magnetic resonance imaging is used for selected cases at 36.4% of sites, mainly for assessment of biliary abnormalities or when blood tests are abnormal. CONCLUSION: Diagnostic imaging is extensively used for postoperative surveillance of children after liver transplantation. While US is generally prioritized, substantial differences were noted in US protocol, timing, and monitoring frequency. The study highlights potential areas for future optimization and standardization of imaging, essential for conducting multicenter studies.


Assuntos
Transplante de Fígado , Radiologia , Criança , Humanos , Ultrassonografia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler , Complicações Pós-Operatórias/diagnóstico por imagem
5.
J Hepatol ; 79(5): 1270-1301, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37863545

RESUMO

Fontan-type surgery is the final step in the sequential palliative surgical treatment of infants born with a univentricular heart. The resulting long-term haemodynamic changes promote liver damage, leading to Fontan-associated liver disease (FALD), in virtually all patients with Fontan circulation. Owing to the lack of a uniform definition of FALD and the competitive risk of other complications developed by Fontan patients, the impact of FALD on the prognosis of these patients is currently debatable. However, based on the increasing number of adult Fontan patients and recent research interest, the European Association for The Study of the Liver and the European Reference Network on Rare Liver Diseases thought a position paper timely. The aims of the current paper are: (1) to provide a clear definition and description of FALD, including clinical, analytical, radiological, haemodynamic, and histological features; (2) to facilitate guidance for staging the liver disease; and (3) to provide evidence- and experience-based recommendations for the management of different clinical scenarios.


Assuntos
Técnicas de Imagem por Elasticidade , Técnica de Fontan , Hepatopatias , Adulto , Lactente , Humanos , Técnica de Fontan/efeitos adversos , Hepatopatias/diagnóstico , Hepatopatias/etiologia , Hepatopatias/cirurgia , Prognóstico , Técnicas de Imagem por Elasticidade/métodos
6.
Pediatr Transplant ; 27(7): e14591, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37583096

RESUMO

BACKGROUND: It is unknown how shear wave dispersion (SWD) is displayed in pediatric liver transplant recipients and not fully elucidated how ultrasound shear wave elastography (2D-SWE) display within this cohort, which is important to determine to improve noninvasive surveillance of these patients. The study aimed to compare SWE and SWD values with histopathology in pediatric liver recipients. METHODS: Forty-eight pediatric liver recipients were examined with SWE in conjunction with an elective liver biopsy (clinically without complication). Additionally, SWD values were measured in 21 children. SWE and SWD values were compared to histologically determined fibrosis graded as none-to-mild (F0-1) and moderate-to-severe (F2-4), and inflammation graded as low (grade 0-1) and high (grade 2-4). RESULTS: Two children were excluded due to SWE IQR/median > 30% kPa. The mean age across 46 included patients was 10.9 years (range 1.4-18). The number of patients and median (range) SWE value (kPa) for each stage of fibrosis were: F0-1 [n = 23; 5.8 (3.2-16.1)], F2 [n = 22; 6.0 (4.5-25.9)], F3 [n = 1; 33.3], and F4 [n = 0]. Significantly higher SWE values and greater variability were registered in F2-4 vs. F0-1 (p = .05). Grade of fibrosis correlated weakly to SWE values (r = .3; p = .05), but not to SWD values (r = .2; p = .27). In patients with low-grade inflammation, median SWD was 13.7 m/s KHz (10.7-17.6). Only one patient had high-grade inflammation. CONCLUSIONS: Uncomplicated transplanted liver grafts in a small pediatric cohort revealed slightly increased SWE and SWD values compared to previously reported values in healthy children. This likely reflect both the fibrotic and inflammatory elements in the grafts; however, other confounders impacting the liver's viscoelastic properties are also probable factors.

7.
J Cogn Neurosci ; 34(12): 2215-2236, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36122354

RESUMO

Ecologically valid research and wearable brain imaging are increasingly important in cognitive neuroscience as they enable researchers to measure neural mechanisms of complex social behaviors in real-world environments. This article presents a proof of principle study that aims to push the limits of what wearable brain imaging can capture and find new ways to explore the neuroscience of acting. Specifically, we focus on how to build an interdisciplinary paradigm to investigate the effects of taking on a role on an actor's sense of self and present methods to quantify interpersonal coordination at different levels (brain, physiology, behavior) as pairs of actors rehearse an extract of a play prepared for live performance. Participants were six actors from Flute Theatre, rehearsing an extract from Shakespeare's A Midsummer Night's Dream. Sense of self was measured in terms of the response of the pFC to hearing one's own name (compared with another person's name). Interpersonal coordination was measured using wavelet coherence analysis of brain signals, heartbeats, breathing, and behavior. Findings show that it is possible to capture an actor's pFC response to their own name and that this response is suppressed when an actor rehearses a segment of the play. In addition, we found that it is possible to measure interpersonal synchrony across three modalities simultaneously. These methods open the way to new studies that can use wearable neuroimaging and hyperscanning to understand the neuroscience of social interaction and the complex social-emotional processes involved in theatrical training and performing theater.


Assuntos
Relações Interpessoais , Dispositivos Eletrônicos Vestíveis , Humanos , Espectroscopia de Luz Próxima ao Infravermelho , Comportamento Social , Mapeamento Encefálico
8.
Neuroimage ; 239: 118255, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34119638

RESUMO

In Parkinson's disease, the depletion of iron-rich dopaminergic neurons in nigrosome 1 of the substantia nigra precedes motor symptoms by two decades. Methods capable of monitoring this neuronal depletion, at an early disease stage, are needed for early diagnosis and treatment monitoring. Magnetic resonance imaging (MRI) is particularly suitable for this task due to its sensitivity to tissue microstructure and in particular, to iron. However, the exact mechanisms of MRI contrast in the substantia nigra are not well understood, hindering the development of powerful biomarkers. In the present report, we illuminate the contrast mechanisms in gradient and spin echo MR images in human nigrosome 1 by combining quantitative 3D iron histology and biophysical modeling with quantitative MRI on post mortem human brain tissue. We show that the dominant contribution to the effective transverse relaxation rate (R2*) in nigrosome 1 originates from iron accumulated in the neuromelanin of dopaminergic neurons. This contribution is appropriately described by a static dephasing approximation of the MRI signal. We demonstrate that the R2* contribution from dopaminergic neurons reflects the product of cell density and cellular iron concentration. These results demonstrate that the in vivo monitoring of neuronal density and iron in nigrosome 1 may be feasible with MRI and provide directions for the development of biomarkers for an early detection of dopaminergic neuron depletion in Parkinson's disease.


Assuntos
Neurônios Dopaminérgicos/química , Ferro/análise , Imageamento por Ressonância Magnética/métodos , Substância Negra/citologia , Idoso de 80 Anos ou mais , Biofísica , Ferritinas/análise , Humanos , Masculino , Melaninas/análise , Pessoa de Meia-Idade , Modelos Neurológicos , Doença de Parkinson/metabolismo , Doença de Parkinson/patologia , Software , Substância Negra/química
9.
Eur Radiol ; 31(3): 1494-1504, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32880696

RESUMO

OBJECTIVES: To assess the concordance of whole-body MRI (WB-MRI) and an FDG-PET/CT-based reference standard for the initial staging in children with Hodgkin lymphoma (HL) METHODS: Children with newly diagnosed HL were included in this prospective, multicentre, international study and underwent WB-MRI and FDG-PET/CT at staging. Two radiologists and a nuclear medicine physician independently evaluated all images. Discrepancies between WB-MRI and FDG-PET/CT were assessed by an expert panel. All FDG-PET/CT errors were corrected to derive the FDG-PET/CT-based reference standard. The expert panel corrected all reader errors in the WB-MRI DWI dataset to form the intrinsic MRI data. Inter-observer agreement for WB-MRI DWI was calculated using overall agreement, specific agreements and kappa statistics. Concordance for correct classification of all disease sites and disease stage between WB-MRI (without DWI, with DWI and intrinsic WB-MRI DWI) and the reference standard was calculated as primary outcome. Secondary outcomes included positive predictive value, negative predictive value and kappa statistics. Clustering within patients was accounted for using a mixed-effect logistic regression model with random intercepts and a multilevel kappa analysis. RESULTS: Sixty-eight children were included. Inter-observer agreement between WB-MRI DWI readers was good for disease stage (κ = 0.74). WB-MRI DWI agreed with the FDG-PET/CT-based reference standard for determining disease stage in 96% of the patients versus 88% for WB-MRI without DWI. Agreement between WB-MRI DWI and the reference standard was excellent for both nodal (98%) and extra-nodal (100%) staging. CONCLUSIONS: WB-MRI DWI showed excellent agreement with the FDG-PET/CT-based reference standard. The addition of DWI to the WB-MRI protocol improved the staging agreement. KEY POINTS: • This study showed excellent agreement between WB-MRI DWI and an FDG-PET/CT-based reference standard for staging paediatric HL. • Diffusion-weighted imaging is a useful addition to WB-MRI in staging paediatric HL. • Inter-observer agreement for WB-MRI DWI was good for both nodal and extra-nodal staging and determining disease stage.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin , Criança , Imagem de Difusão por Ressonância Magnética , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Humanos , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Padrões de Referência , Imagem Corporal Total
10.
Eur Radiol ; 31(12): 8925-8936, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34021390

RESUMO

OBJECTIVES: To compare WB-MRI with an [18F]FDG-PET/CT-based reference for early response assessment and restaging in children with Hodgkin's lymphoma (HL). METHODS: Fifty-one children (ages 10-17) with HL were included in this prospective, multicentre study. All participants underwent WB-MRI and [18F]FDG-PET/CT at early response assessment. Thirteen of the 51 patients also underwent both WB-MRI and [18F]FDG-PET/CT at restaging. Two radiologists independently evaluated all WB-MR images in two separate readings: without and with DWI. The [18F]FDG-PET/CT examinations were evaluated by a nuclear medicine physician. An expert panel assessed all discrepancies between WB-MRI and [18F]FDG-PET/CT to derive the [18F]FDG-PET/CT-based reference standard. Inter-observer agreement for WB-MRI was calculated using kappa statistics. Concordance, PPV, NPV, sensitivity and specificity for a correct assessment of the response between WB-MRI and the reference standard were calculated for both nodal and extra-nodal disease presence and total response evaluation. RESULTS: Inter-observer agreement of WB-MRI including DWI between both readers was moderate (κ 0.46-0.60). For early response assessment, WB-MRI DWI agreed with the reference standard in 33/51 patients (65%, 95% CI 51-77%) versus 15/51 (29%, 95% CI 19-43%) for WB-MRI without DWI. For restaging, WB-MRI including DWI agreed with the reference standard in 9/13 patients (69%, 95% CI 42-87%) versus 5/13 patients (38%, 95% CI 18-64%) for WB-MRI without DWI. CONCLUSIONS: The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric HL improved agreement with the [18F]FDG-PET/CT-based reference standard. However, WB-MRI remained discordant in 30% of the patients compared to standard imaging for assessing residual disease presence. KEY POINTS: • Inter-observer agreement of WB-MRI including DWI between both readers was moderate for (early) response assessment of paediatric Hodgkin's lymphoma. • The addition of DWI to the WB-MRI protocol in early response assessment and restaging of paediatric Hodgkin's lymphoma improved agreement with the [18F]FDG-PET/CT-based reference standard. • WB-MRI including DWI agreed with the reference standard in respectively 65% and 69% of the patients for early response assessment and restaging.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin , Adolescente , Criança , Imagem de Difusão por Ressonância Magnética , Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Humanos , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos , Padrões de Referência , Imagem Corporal Total
11.
J Cardiovasc Magn Reson ; 23(1): 134, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34781968

RESUMO

BACKGROUND: The extent and significance in of cardiac remodeling in Fontan patients are unclear and were the subject of this study. METHODS: This retrospective cohort study compared cardiovascular magnetic resonance (CMR) imaging markers of cardiac function, myocardial fibrosis, and hemodynamics in young Fontan patients to controls. RESULTS: Fifty-five Fontan patients and 44 healthy controls were included (median age 14 years (range 7-17 years) vs 13 years (range 4-14 years), p = 0.057). Fontan patients had a higher indexed end-diastolic ventricular volume (EDVI 129 ml/m2 vs 93 ml/m2, p < 0.001), and lower ejection fraction (EF 45% vs 58%, p < 0.001), circumferential (CS - 23.5% vs - 30.8%, p < 0.001), radial (6.4% vs 8.2%, p < 0.001), and longitudinal strain (- 13.3% vs - 24.8%, p < 0.001). Compared to healthy controls, Fontan patients had higher extracellular volume fraction (ECV) (26.3% vs 20.6%, p < 0.001) and native T1 (1041 ms vs 986 ms, p < 0.001). Patients with a dominant right ventricle demonstrated larger ventricles (EDVI 146 ml/m2 vs 120 ml/m2, p = 0.03), lower EF (41% vs 47%, p = 0.008), worse CS (- 20.1% vs - 25.6%, p = 0.003), and a trend towards higher ECV (28.3% versus 24.1%, p = 0.09). Worse EF and CS correlated with longer cumulative bypass (R = - 0.36, p = 0.003 and R = 0.46, p < 0.001), cross-clamp (R = - 0.41, p = 0.001 and R = 0.40, p = 0.003) and circulatory arrest times (R = - 0.42, p < 0.001 and R = 0.27, p = 0.03). T1 correlated with aortopulmonary collateral (APC) flow (R = 0.36, p = 0.009) which, in the linear regression model, was independent of ventricular morphology (p = 0.9) and EDVI (p = 0.2). The composite outcome (cardiac readmission, cardiac reintervention, Fontan failure or any clinically significant arrhythmia) was associated with increased native T1 (1063 ms vs 1026 ms, p = 0.029) and EDVI (146 ml/m2 vs 118 ml/m2, p = 0.013), as well as decreased EF (42% vs 46%, p = 0.045) and worse CS (- 22% vs - 25%, p = 0.029). APC flow (HR 5.5 CI 1.9-16.2, p = 0.002) was independently associated with the composite outcome, independent of ventricular morphology (HR 0.71 CI 0.30-1.69 p = 0.44) and T1 (HR1.006 CI 1.0-1.13, p = 0.07). CONCLUSIONS: Pediatric Fontan patients have ventricular dysfunction, altered myocardial mechanics and increased fibrotic remodeling. Cumulative exposure to cardiopulmonary bypass and increased aortopulmonary collateral flow are associated with myocardial dysfunction and fibrosis. Cardiac dysfunction, fibrosis, and collateral flow are associated with adverse outcomes.


Assuntos
Ventrículos do Coração , Imagem Cinética por Ressonância Magnética , Adolescente , Criança , Fibrose , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda
12.
Pediatr Radiol ; 51(1): 66-76, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33033916

RESUMO

BACKGROUND: Children with Fontan circulation are at risk of developing hepatic fibrosis/cirrhosis. Reliable noninvasive monitoring techniques are lacking or under development. OBJECTIVE: To investigate surrogate indicators of hepatic fibrosis in adolescents with Fontan circulation by evaluating hepatic magnetic resonance (MR) T1 mapping and extracellular volume fraction measurements compared to US shear-wave elastography. MATERIALS AND METHODS: We analyzed hepatic native T1 times and extracellular volume fractions with modified Look-Locker inversion recovery. Liver stiffness was analyzed with shear-wave elastography. We compared results between 45 pediatric patients ages 16.7±0.6 years with Fontan circulation and 15 healthy controls ages 19.2±1.2 years. Measurements were correlated to clinical and hemodynamic data from cardiac catheterization. RESULTS: MR mapping was successful in 35/45 patients, revealing higher hepatic T1 times (774±44 ms) than in controls (632±52 ms; P<0.001) and higher extracellular volume fractions (47.4±5.0%) than in controls (34.6±3.8%; P<0.001). Liver stiffness was 1.91±0.13 m/s in patients vs. 1.20±0.10 m/s in controls (P<0.001). Native T1 times correlated with central venous pressures (r=0.5, P=0.007). Native T1 was not correlated with elastography in patients (r=0.2, P=0.1) or controls (r = -0.3, P=0.3). Extracellular volume fraction was correlated with elastography in patients (r=0.5, P=0.005) but not in controls (r=0.2, P=0.6). CONCLUSION: Increased hepatic MR relaxometry and shear-wave elastography values in adolescents with Fontan circulation suggested the presence of hepatic fibrosis or congestion. Central venous pressure was related to T1 times. Changes were detected differently with MR relaxometry and elastography; thus, these techniques should not be used interchangeably in monitoring hepatic fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Técnica de Fontan , Hepatopatias , Adolescente , Adulto , Criança , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatias/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Adulto Jovem
13.
Pediatr Radiol ; 51(13): 2598-2606, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34654967

RESUMO

Since Francis Fontan first introduced the eponymous technique, the Fontan procedure, this type of surgical palliation has allowed thousands of children affected by specific heart malformations to reach adulthood. Nevertheless, abdominal, thoracic, lymphatic and neurologic complications are the price that is paid by these patients. Our review focuses on Fontan-associated liver disease; the purpose is to summarize the current understanding of its physiopathology, the aim of follow-up and the specific radiologic follow-up performed in Europe. Finally, we as members of the Abdominal Task Force of the European Society of Paediatric Radiology propose a consensus-based imaging follow-up algorithm.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Hepatopatias , Radiologia , Adulto , Criança , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Fígado/patologia , Cirrose Hepática/patologia , Hepatopatias/patologia , Complicações Pós-Operatórias/patologia
14.
Pediatr Radiol ; 51(13): 2607-2610, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34654969

RESUMO

Fontan surgery is a life-saving procedure for newborns with complex cardiac malformations, but it originates complications in different organs. The liver is also affected, with development of fibrosis and sometimes cirrhosis and hepatocellular carcinoma. There is no general agreement on how to follow-up these children for the development of liver disease. To understand the current practice on liver follow-up, we invited members of the European Society of Paediatric Radiology (ESPR) to fill out an online questionnaire. The survey comprised seven questions about when and how liver follow-up is performed on Fontan patients. While we found some agreement on the use of US as screening tool, and of MRI for nodule characterization, the discrepancies on timing and the lack of a shared protocol make it currently impossible to compare data among centers.


Assuntos
Carcinoma Hepatocelular , Técnica de Fontan , Cardiopatias Congênitas , Neoplasias Hepáticas , Radiologia , Criança , Consenso , Seguimentos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Recém-Nascido , Cirrose Hepática , Neoplasias Hepáticas/diagnóstico por imagem , Inquéritos e Questionários
15.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-32375896

RESUMO

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas/normas , Consenso , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
16.
Pediatr Radiol ; 50(10): 1478, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32816053

RESUMO

In the original version of this paper there was an inadvertent misnumbering of references.

17.
Pediatr Radiol ; 50(10): 1333-1348, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32468285

RESUMO

The Fontan operation is performed for various cardiac lesions with single-ventricle physiology. The survival rate of Fontan patients is increasing for adolescents and young adults, with an expected 30-year survival of >80%. Medical health care providers including specialists in organ systems and pediatric radiologists need to improve their knowledge about the Fontan circulation and the various organ complications to monitor care. In this review the author explains the basic anatomical and functional features of Fontan palliation and gives an overview of the multiple long-term organ complications that might present in the pediatric population. These include decreased physical capacity, ventricular dysfunction, atrioventricular valve regurgitation and arrhythmia, as well as protein-losing enteropathy, plastic bronchitis, growth/bone composition disturbances, renal dysfunction, and the recently recognized and important liver fibrosis (Fontan-associated liver disease). Neuropsychological and behavioral deficits occur frequently. This review focuses on the key role of radiology in making the diagnosis of these complications, monitoring therapy and predicting outcomes in the pediatric age group. The author discusses how and when radiology is important in Fontan patients, as well as how new techniques enabling quantitative measures in imaging with US, MRI and CT are adapted for pediatric use, and how they contribute to urgently needed surveillance strategies.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Criança , Humanos
18.
J Cardiovasc Magn Reson ; 21(1): 39, 2019 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-31303178

RESUMO

BACKGROUND: Patients with single ventricle physiology are at increased risk for developing liver fibrosis. Its extent and prevalence in children with bidirectional cavopulmonary connection (BCPC) and Fontan circulation are unclear. Extracellular volume fraction (ECV), derived from cardiovascular magnetic resonance (CMR) and T1 relaxometry, reflect fibrotic remodeling and/or congestion in the liver. The aim of this study was to investigate whether pediatric patients with single ventricle physiology experience increased native T1 and ECV as markers of liver fibrosis/congestion. METHODS: Hepatic native T1 times and ECV, using a cardiac short axis modified Look-Locker inversion recovery sequence displaying the liver, were measured retrospectively in children with BCPC- and Fontan circulations and compared to pediatric controls. RESULTS: Hepatic native T1 time were increased in Fontan patients (n = 62, 11.4 ± 4.4 years, T1 762 ± 64 ms) versus BCPC patients (n = 20, 2.8 ± 0.9 years, T1 645 ± 43 ms, p = 0.04). Both cohorts had higher T1 than controls (n = 44, 13.7 ± 2.9 years, T1 604 ± 54 ms, p < 0.001 for both). ECV was 41.4 ± 4.8% in Fontan and 36.4 ± 4.8% in BCPC patients, respectively (p = 0.02). In Fontan patients, T1 values correlated with exposure to cardiopulmonary bypass time (R = 0.3, p = 0.02), systolic and end diastolic volumes (R = 0.3, p = 0.04 for both) and inversely with oxygen saturations and body surface area (R = -0.3, p = 0.04 for both). There were no demonstrable associations of T1 or ECV with central venous pressure or age after Fontan. CONCLUSION: Fontan and BCPC patients have elevated CMR markers suggestive of hepatic fibrosis and/or congestion, even at a young age. The tissue changes do not appear to be related to central venous pressures. TRIAL REGISTRATION: Retrospectively registered data.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cirrose Hepática/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Estudos de Viabilidade , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Lactente , Cirrose Hepática/etiologia , Cirrose Hepática/fisiopatologia , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
20.
Pediatr Radiol ; 48(11): 1567-1575, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29974179

RESUMO

BACKGROUND: Assessment of qualitative or subjective image quality in radiology is traditionally performed using a fixed-point scale even though reproducibility has proved challenging. OBJECTIVE: Image quality of 3-T coronary magnetic resonance (MR) angiography was evaluated using three scoring methods, hypothesizing that a continuous scoring scale like visual analogue scale would improve the assessment. MATERIALS AND METHODS: Adolescents corrected for transposition of the great arteries with arterial switch operation, ages 9-15 years (n=12), and healthy, age-matched controls (n=12), were examined with 3-D steady-state free precession magnetic resonance imaging. Image quality of the coronary artery origin was evaluated by using a fixed-point scale (1-4), visual analogue scale of 10 cm and a visual analogue scale with reference points (figurative visual analogue scale). Satisfactory image quality was set to a fixed-point scale 3=visual analogue scale/figurative visual analogue scale 6.6 cm. Statistical analysis was performed using Cohen kappa coefficient and agreement index. RESULTS: The mean interobserver scores for the fixed-point scale, visual analogue scale and figurative visual analogue scale were, respectively, in the left main stem 2.8, 5.7, 7.0; left anterior descending artery 2.8, 4.7, 6.6; circumflex artery 2.5, 4.5, 6.2, and right coronary artery 3.2, 6.3, 7.7. Scoring with a fixed-point scale gave an intraobserver κ of 0.52-0.77 while interobserver κ was lacking. For visual analogue scale and figurative visual analogue scale, intraobserver agreement indices were, respectively, 0.08-0.58 and 0.43-0.71 and interobserver agreement indices were up to 0.5 and 0.65, respectively. CONCLUSION: Qualitative image quality evaluation with coronary 3-D steady-state free precession MR angiography, using a visual analogue scale with reference points, had better reproducibility compared to a fixed-point scale and visual analogue scale. Image quality, being a continuum, may be better determined by this method.


Assuntos
Angiografia por Ressonância Magnética/normas , Qualidade da Assistência à Saúde , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Escala Visual Analógica , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA