Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Biomed Opt ; 12(5): 052001, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17994887

RESUMO

Dynamic optical imaging is increasingly applied to clinically relevant areas such as brain and cancer imaging. In this approach, some external stimulus is applied and changes in relevant physiological parameters (e.g., oxy- or deoxyhemoglobin concentrations) are determined. The advantage of this approach is that the prestimulus state can be used as a reference or baseline against which the changes can be calibrated. Here we present the first application of this method to the problem of characterizing joint diseases, especially effects of rheumatoid arthritis (RA) in the proximal interphalangeal finger joints. Using a dual-wavelength tomographic imaging system together with previously implemented model-based iterative image reconstruction schemes, we have performed initial dynamic imaging case studies on a limited number of healthy volunteers and patients diagnosed with RA. Focusing on three cases studies, we illustrated our major finds. These studies support our hypothesis that differences in the vascular reactivity exist between affected and unaffected joints.


Assuntos
Artrite Reumatoide/metabolismo , Artrite Reumatoide/patologia , Articulações dos Dedos/metabolismo , Articulações dos Dedos/patologia , Hemoglobinas/análise , Interpretação de Imagem Assistida por Computador/métodos , Biomarcadores/análise , Velocidade do Fluxo Sanguíneo , Humanos , Taxa de Depuração Metabólica
2.
Rev Sci Instrum ; 78(8): 083706, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764328

RESUMO

In this article, we introduce a dynamic optical tomography system that is, unlike currently available analog instrumentation, based on digital data acquisition and filtering techniques. At the core of this continuous wave instrument is a digital signal processor (DSP) that collects, collates, processes, and filters the digitized data set. The processor is also responsible for managing system timing and the imaging routines which can acquire real-time data at rates as high as 150 Hz. Many of the synchronously timed processes are controlled by a complex programmable logic device that is also used in conjunction with the DSP to orchestrate data flow. The operation of the system is implemented through a comprehensive graphical user interface designed with LABVIEW software which integrates automated calibration, data acquisition, data organization, and signal postprocessing. Performance analysis demonstrates very low system noise (approximately 1 pW rms noise equivalent power), excellent signal precision (<0.04%-0.2%) and long term system stability (<1% over 40 min). A large dynamic range (approximately 190 dB) accommodates a wide scope of measurement geometries and tissue types. First experiments on tissue phantoms show that dynamic behavior is accurately captured and spatial location can be correctly tracked using this system.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia Óptica/instrumentação , Algoritmos , Sistemas Computacionais , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA