Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Skeletal Radiol ; 48(9): 1393-1398, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30790010

RESUMO

OBJECTIVE: Accurate insertion of a guidewire under image intensifier guidance is a fundamental skill required by orthopaedic surgeons. This study investigated how image intensifier distortion, which is composed of pin-cushion and sigmoidal components, changed the apparent trajectory of a guidewire, and the resulting deviation between the intended and actual guidewire tip position. MATERIALS AND METHODS: Intraoperative image intensifier images for 220 consecutive patients with hip fractures were retrospectively corrected for distortion using a global polynomial method. The deviation between the intended and actual guidewire tip positions was calculated. Additional distortion parameters were tested using an image intensifier produced by a different manufacturer, and a flat-panel c-arm. RESULTS: Deviation was approximately 1 cm if the guidewire was aimed from the extremity of the image and almost 0 if the entry point was only 20% from the centre (p < 0.001). The direction of deviation was different for left and right hips, with average deviations measuring 3 mm proximal and 5 mm distal respectively (p < 0.001). The flat-panel c-arm almost completely eliminated distortion. CONCLUSIONS: Image intensifier distortion significantly altered the intended trajectory of a guidewire, with guidewires aimed from the image periphery more affected than guidewires aimed from the centre. Furthermore, for right hips, guidewires should be aimed distal to their intended position, and for left hips they should be aimed proximal to achieve their desired position. The flat-panel c-arm eliminated the effect of distortion; hence, it may be preferable if precision in guidewire positioning is vital.


Assuntos
Fraturas do Quadril/diagnóstico por imagem , Cuidados Intraoperatórios/métodos , Procedimentos Ortopédicos/métodos , Intensificação de Imagem Radiográfica/métodos , Radiografia Intervencionista/métodos , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia , Fraturas do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Estudos Retrospectivos
2.
J Shoulder Elbow Surg ; 25(1): 12-21, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26264504

RESUMO

BACKGROUND: Patients with rotator cuff tears often recall a specific initiating event (traumatic), whereas many cannot (nontraumatic). It is unclear how important a history of trauma is to the outcomes of rotator cuff repair. METHODS: This question was addressed in a study cohort of 1300 consecutive patients who completed a preoperative questionnaire regarding their shoulder injury and had a systematic evaluation of shoulder range of motion and strength, a primary arthroscopic rotator cuff repair performed by a single surgeon, an ultrasound scan, and the same subjective and objective measurements made of their shoulder 6 months after surgery. Post hoc, this cohort was separated into 2 groups: those who reported no history of trauma on presentation (n = 489) and those with a history of traumatic injury (n = 811). RESULTS: The retear rate in the group with no history of trauma was 12%, whereas that of the group with a history of trauma was 14% (P = .36). Those patients with a history of shoulder trauma who waited longer than 24 months had higher retear rates (20%) than those who had their surgery earlier (13%) (P = .040). CONCLUSION: Recollection of a traumatic initiating event had little effect on the outcome of arthroscopic rotator cuff repair. Duration of symptoms was important in predicting retears if patients recalled a specific initiating event but not in patients who did not recall any specific initiating event. Patients with a history of trauma should be encouraged to have their rotator cuff tear repaired within 2 years.


Assuntos
Lacerações/etiologia , Lesões do Manguito Rotador , Traumatismos dos Tendões/etiologia , Cicatrização , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Feminino , Humanos , Lacerações/fisiopatologia , Lacerações/cirurgia , Masculino , Pessoa de Meia-Idade , Força Muscular , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos , Manguito Rotador/cirurgia , Ruptura/etiologia , Ruptura/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/cirurgia , Inquéritos e Questionários , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
HardwareX ; 18: e00533, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711599

RESUMO

Microscopes are essential for the biomechanical and hydrodynamical investigation of small aquatic organisms. We report a prototype of a do-it-yourself microscope that enables the visualization of organisms from two orthogonal imaging planes - top and side views. Compared to conventional imaging systems, this approach provides a comprehensive visualization strategy of organisms, which could have complex shapes and morphologies. The microscope was constructed by combining custom 3D-printed parts and off-the-shelf components. The system is designed for modularity and reconfigurability. Open-source design files and build instructions are provided in this report. Additionally, proof-of-use experiments (particularly with Hydra) and other organisms that combine the imaging with an analysis pipeline were demonstrated to highlight the system's utility. Beyond the applications demonstrated, the system can be used or modified for various imaging applications.

4.
Biology (Basel) ; 12(1)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36671808

RESUMO

Selective plane illumination microscopy (SPIM), or light sheet microscopy, is a powerful imaging approach. However, access to and interfacing microscopes with microfluidics have remained challenging. Complex interfacing with microfluidics has limited the SPIM's utility for studying the hydrodynamics of freely moving multicellular organisms. We developed SPIM-Flow, an inexpensive light sheet platform that enables easy integration with microfluidics. We used SPIM-Flow to investigate the hydrodynamics of a freely moving Hydra polyp via particle tracking in millimeter-sized chambers. Initial experiments across multiple animals, feeding on a chip (Artemia franciscana nauplii used as food), and baseline behaviors (tentacle swaying, elongation, and bending) indicated the organisms' health inside the system. Fluidics were used to investigate Hydra's response to flow. The results suggested that the animals responded to an established flow by bending and swaying their tentacles in the flow direction. Finally, using SPIM-Flow in a proof-of-concept experiment, the shear stress required to detach an animal from a surface was demonstrated. Our results demonstrated SPIM-Flow's utility for investigating the hydrodynamics of freely moving animals.

5.
ArXiv ; 2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37547659

RESUMO

Microscopes are essential for the biomechanical and hydrodynamical investigation of small aquatic organisms. We report a do-it-yourself microscope (GLUBscope) that enables the visualization of organisms from two orthogonal imaging planes - top and side views. Compared to conventional imaging systems, this approach provides a comprehensive visualization strategy of organisms, which could have complex shapes and morphologies. The microscope was constructed by combining custom 3D-printed parts and off-the-shelf components. The system is designed for modularity and reconfigurability. Open-source design files and build instructions are provided in this report. Additionally, proof-of-use experiments (particularly with Hydra) and other organisms that combine the GLUBscope with an analysis pipeline were demonstrated to highlight the system's utility. Beyond the applications demonstrated, the system can be used or modified for various imaging applications.

6.
Am J Sports Med ; 42(5): 1134-42, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24748610

RESUMO

BACKGROUND: The rate of retears after rotator cuff repair varies from 11% to 94%. A retear is associated with poorer subjective and objective clinical outcomes than intact repair. PURPOSE: This study was designed to determine which preoperative and/or intraoperative factors held the greatest association with retears after arthroscopic rotator cuff repair. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: This study retrospectively evaluated 1000 consecutive patients who had undergone a primary rotator cuff repair by a single surgeon using an arthroscopic inverted-mattress knotless technique and who had undergone an ultrasound evaluation 6 months after surgery to assess repair integrity. Exclusion criteria included previous rotator cuff repair on the same shoulder, incomplete repair, and repair using a synthetic polytetrafluoroethylene patch. All patients had completed the modified L'Insalata Questionnaire and underwent a clinical examination before surgery. Measurements of tear size, tear thickness, associated shoulder injury, tissue quality, and tendon mobility were recorded intraoperatively. RESULTS: The overall retear rate at 6 months after surgery was 17%. Retears occurred in 27% of full-thickness tears and 5% of partial-thickness tears (P < .0001). The best independent predictors of retears were anteroposterior tear length (correlation coefficient r = 0.41, P < .0001), tear size area (r = 0.40, P < .0001), mediolateral tear length (r = 0.34, P < .0001), tear thickness (r = 0.29, P < .0001), age at surgery (r = 0.27, P < .0001), and operative time (r = 0.18, P < .0001). These factors produced a predictive model for retears: logit P = (0.039 × age at surgery in years) + (0.027 × tear thickness in %) + (1 × anteroposterior tear length in cm) + (0.76 × mediolateral tear length in cm) - (0.17 × tear size area in cm(2)) + (0.018 × operative time in minutes) -9.7. Logit P can be transformed into P, which is the chance of retears at 6 months after surgery. CONCLUSION: A rotator cuff retear is a multifactorial process with no single preoperative or intraoperative factor being overwhelmingly predictive of it. Nevertheless, rotator cuff tear size (tear dimensions, tear size area, and tear thickness) showed stronger associations with retears at 6 months after surgery than did measures of tissue quality and concomitant shoulder injuries.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroscopia , Atletas/estatística & dados numéricos , Estudos de Coortes , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Força Muscular , Duração da Cirurgia , Osteoartrite/epidemiologia , Exame Físico , Recidiva , Estudos Retrospectivos , Rotação , Ruptura , Luxação do Ombro/epidemiologia , Âncoras de Sutura , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA