1.
Ann Clin Biochem ; 29 ( Pt 1): 85-9, 1992 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1536532

RESUMO

The estimation of serum urate by uricase/peroxidase procedures involving single point bichromatic absorbance monitoring gives inaccurate results with samples which are haemolysed, icteric or lipaemic. These inaccuracies can be greatly minimized by reducing the rate of chromogen formation and applying the assay in a kinetic mode.


Assuntos
Urato Oxidase/sangue , Bilirrubina/sangue , Emulsões Gordurosas Intravenosas/metabolismo , Hemólise , Humanos , Lipídeos/sangue , Espectrofotometria Atômica/instrumentação
3.
Clin Chem ; 38(7): 1342-5, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1623602

RESUMO

We describe a method for simultaneously determining albumin, by using bromcresol purple, and calcium, by using Arsenazo III, in the same analytical cuvette on the Hitachi 704. Both assays agree well with accepted procedures. The standard curves for the albumin and calcium assays are linear from 0 to 60 g/L and 0 to 5.0 mmol/L, respectively. Calibration is stable for 7 days with use of open reagent in the instrument. Both assays are unaffected by hemoglobin less than or equal to 5 g/L and Intralipid less than or equal to 4 g/L; calcium is unaffected by bilirubin less than or equal to 600 mumol/L.


Assuntos
Cálcio/sangue , Albumina Sérica/análise , Arsenazo III , Autoanálise/métodos , Púrpura de Bromocresol , Humanos , Controle de Qualidade
4.
Clin Chem ; 38(6): 904-8, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1597016

RESUMO

We describe a method based on a single stable reagent for the determination of calcium in serum and plasma with use of Arsenazo III, 200 mumol/L in 50 mmol/L 1,4-piperazinediethanesulfonic acid (PIPES) buffer. The method showed significant positive interference in plasma at pH less than 6.6 because of the precipitation of fibrinogen, which was eliminated by increasing the pH to 6.8. The assay showed no interference from as much as 600 mumol of bilirubin and 12 g of hemoglobin per liter when applied in a simple monochromatic procedure at 660 nm. The standard curve for calcium was linear from 0 to 5.0 mmol/L. Addition of Intralipid at concentrations greater than 3 g/L demonstrated positive interference, which could be eliminated by using a 700-nm blanking wavelength. The procedure showed good agreement with all-method mean values from two external quality-control schemes.


Assuntos
Arsenazo III , Cálcio/sangue , Indicadores e Reagentes , Bilirrubina/sangue , Estabilidade de Medicamentos , Emulsões Gordurosas Intravenosas , Hemólise , Humanos , Concentração de Íons de Hidrogênio , Fotometria/estatística & dados numéricos , Controle de Qualidade
5.
Clin Chem ; 38(2): 298-302, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1311645

RESUMO

We describe a rapid kinetic glucose oxidase (EC 1.1.3.4) procedure for quantifying glucose. Glucose oxidase concentration was reduced from the more usual 20 kU/L to 4 kU/L, and pH was reduced from 7.0 to 6.6. Potassium ferrocyanide (20 mumol/L) and ascorbate oxidase (1 kU/L) were incorporated in the procedure. The assay results vary linearly with glucose concentration from 0 to 50 mmol/L and are unaffected by bilirubin concentrations less than or equal to 600 mumol/L, hemoglobin less than or equal to 12 g/L, Intralipid less than or equal to 4 g/L, urate less than or equal to 1 mmol/L, and ascorbate less than or equal to 2.0 mmol/L. The assay is readily adaptable to most open-system analyzers.


Assuntos
Glicemia/análise , Glucose Oxidase , Ácido Ascórbico , Aspergillus/enzimologia , Autoanálise/métodos , Autoanálise/estatística & dados numéricos , Bilirrubina/sangue , Ferrocianetos , Humanos , Concentração de Íons de Hidrogênio , Peroxidase , Controle de Qualidade