Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Stroke ; 53(12): 3622-3632, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36128905

RESUMO

BACKGROUND: A high and low estimated glomerular filtration rate (eGFR) could affect outcomes after reperfusion therapy for ischemic stroke. This study aimed to determine whether renal function based on eGFR affects mortality risk in patients with ischemic stroke within 6 months following reperfusion therapy. METHODS: This prospective registry-based cohort study included 2266 patients who received reperfusion therapy between January 2000 and September 2019 and were registered in the SECRET (Selection Criteria in Endovascular Thrombectomy and Thrombolytic Therapy) study or the Yonsei Stroke Cohort. A high and low eGFR were based on the Chronic Kidney Disease Epidemiology Collaboration equation and defined, respectively, as the 5th and 95th percentiles of age- and sex-specific eGFR. Occurrence of death within 6 months was compared among the groups according to their eGFR such as low, normal, or high eGFR. RESULTS: Of the 2266 patients, 2051 (90.5%) had a normal eGFR, 110 (4.9%) a low eGFR, and 105 (4.6%) a high eGFR. Patients with high eGFR were younger or less likely to have hypertension, diabetes, or atrial fibrillation than the other groups. Active cancer was more prevalent in the high-eGFR group. During the 6-month follow-up, there were 24 deaths (22.9%) in the high-eGFR group, 37 (33.6%) in the low-eGFR group, and 237 (11.6%) in the normal-eGFR group. After adjusting for variables with P<0.10 in the univariable analysis, 6-month mortality was independently associated with high eGFR (hazard ratio, 2.22 [95% CI, 1.36-3.62]; P=0.001) and low eGFR (HR, 2.29 [95% CI, 1.41-3.72]; P=0.001). These associations persisted regardless of treatment modality or various baseline characteristics. CONCLUSIONS: High eGFR as well as low eGFR were independently associated with 6-month mortality after reperfusion therapy. Kidney function could be considered a prognostic factor in patients with ischemic stroke after reperfusion therapy.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Feminino , Humanos , Estudos de Coortes , Rim/fisiologia , Taxa de Filtração Glomerular , Acidente Vascular Cerebral/epidemiologia , Reperfusão , Fatores de Risco
2.
Epilepsia ; 61(1): 70-80, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31828789

RESUMO

OBJECTIVE: Considering the clinical heterogeneity of temporal lobe epilepsy with amygdala enlargement (TLE-AE), identifying distinct prognostic subgroups of TLE-AE has clinical implications. Until now, baseline volume of the enlarged amygdala (EAV) has consistently failed to predict prognosis in TLE-AE. Based on studies suggesting that patients responsive to antiepileptic drugs (AEDs) exhibit remission of AE on follow-up imaging, we investigated whether reduction rate of EAV is predictive of long-term prognosis in TLE-AE. METHODS: Sixty-one consecutive patients with two separate magnetic resonance imaging (MRI) scans were enrolled. To utilize longitudinally measured biomarkers in prediction, the period beyond the first MRI acquisition was split into two periods: the "observation window" (period between the two MRIs) and "prediction window" (follow-up period beyond the second MRI). Patients were classified according to their AED responsiveness during the observation window, and AED-responsive patients were further subdivided by initial seizure frequency: (a) AED-responsive patients presenting with low-frequency seizures (<5 seizures/3 mo; Group A, n = 25), (b) high-frequency seizures (≥5 seizures/3 mo; Group B, n = 23), and (c) patients with poor initial treatment response (Group C, n = 13). Multivariate logistic regression models were constructed for identification of prognostic factors. Along with factors obtained at baseline, factors derived from the observation window (annual percentage change of EAV [APCEAV] and initial AED responsiveness) were also considered as potential predictors. RESULTS: Favorable initial treatment response and faster volume reduction rate (APCEAV ≤ -5.0%/y) were identified as factors predictive of achieving overall seizure freedom. Among the AED-responsive patients, Group A (low-frequency seizures) showed slower remission of AE and higher rate of seizure recurrence, whereas Group B (high-frequency seizures) exhibited faster remission of AE and lower rate of seizure recurrence. SIGNIFICANCE: Faster recuperation of AE in patients with initial high-frequency seizures may be indicative of seizure-induced changes. As volume reduction rate serves as a prognostic marker in TLE-AE, short-term MRI follow-up may be useful in prognostication.


Assuntos
Tonsila do Cerebelo/patologia , Epilepsia do Lobo Temporal/patologia , Adulto , Anticonvulsivantes/uso terapêutico , Epilepsia do Lobo Temporal/tratamento farmacológico , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico
3.
Diabetes Metab J ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38772545

RESUMO

Background: We investigated the association between body composition changes and new-onset diabetes mellitus (DM) development according to the body mass index (BMI) in a longitudinal setting in the general Korean population. Methods: From 2010 to 2011 (1st) and 2012 to 2013 (2nd), we included 1,607,508 stratified random sample participants without DM from the National Health Insurance Service-Health Screening dataset of Korean. The predicted appendicular skeletal muscle mass index (pASMMI), body fat mass index (pBFMI), and lean body mass index (pLBMI) were calculated using pre-validated anthropometric prediction equations. A prediction equation was constructed by combining age, weight, height, waist circumference, serum creatinine levels, alcohol consumption status, physical activity, and smoking history as variables affecting body composition. Results: Decreased pASMMI (men: hazard ratio [HR], 0.866; 95% confidence interval [CI], 0.830 to 0.903; P<0.001; women: HR, 0.748; 95% CI, 0.635 to 0.881; P<0.001), decreased pLBMI (men: HR, 0.931; 95% CI, 0.912 to 0.952; P<0.001; women: HR, 0.906; 95% CI, 0.856 to 0.959; P=0.007), and increased pBFMI (men: HR, 1.073; 95% CI, 1.050 to 1.096; P<0.001; women: HR, 1.114; 95% CI, 1.047 to 1.186; P=0.007) correlated with the development of new-onset DM. Notably, only in the overweight and obese BMI categories, decreases in pASMMI and pLBMI and increases in pBFMI associated with new-onset DM, regardless of gender. Conclusion: Decreased pASMMI and pLBMI, and increased pBFMI with excess fat accumulation may enhance the risk of newonset DM. Therefore, appropriate changes in body composition can help prevent new-onset DM.

4.
Phys Chem Chem Phys ; 15(6): 1788-92, 2013 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-23258449

RESUMO

We report the origin of the improvement of the power conversion efficiency (PCE) of hybrid thin-film solar cells when a soluble C(60) derivative, [6,6]-phenyl-C(61)-butyric acid methyl ester (PCBM), is introduced as a hole-blocking layer. The PCBM layer could establish better interfacial contact by decreasing the reverse dark-saturation current density, resulting in a decrease in the probability of carrier recombination. The PCE of this optimized device reached a maximum value of 8.34% and is the highest yet reported for hybrid thin-film solar cells.

5.
Nanomaterials (Basel) ; 12(13)2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35808145

RESUMO

Fiber-shaped dye-sensitized solar cells (FDSSCs) with flexibility, weavablity, and wearability have attracted intense scientific interest and development in recent years due to their low cost, simple fabrication, and environmentally friendly operation. Since the Grätzel group used the organic radical 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO) as the redox system in dye-sensitized solar cells (DSSCs) in 2008, TEMPO has been utilized as an electrolyte to further improve power conversion efficiency (PCE) of solar cells. Hence, the TEMPO with high catalyst oxidant characteristics was developed as a hybrid solid-state electrolyte having high conductivity and stability structure by being integrated with a lithium bis(trifluoromethanesulfonyl)imide (Li-TFSI) film for FDSSCs. The optimized 4-Oxo TEMPO (OX) based solid-state FDSSC (SS-FDSSC) showed the PCE of up to 6%, which was improved by 34.2% compared to that of the reference device with 4.47%. The OX-enhanced SS-FDSSCs reduced a series resistance (Rs) resulting in effective electron extraction with improved short-circuit current density (JSC), while increasing a shunt resistance (Rsh) to prevent the recombination of photo-excited electrons. The result is an improvement in a fill factor (FF) and consequently a higher value for the PCE.

6.
Nanomaterials (Basel) ; 13(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36616042

RESUMO

Surface coating approaches for silicon (Si) have demonstrated potential for use as anodes in lithium-ion batteries (LIBs) to address the large volume change and low conductivity of Si. However, the practical application of these approaches remains a challenge because they do not effectively accommodate the pulverization of Si during cycling or require complex processes. Herein, Si-embedded titanium oxynitride (Si-TiON) was proposed and successfully fabricated using a spray-drying process. TiON can be uniformly coated on the Si surface via self-assembly, which can enhance the Si utilization and electrode stability. This is because TiON exhibits high mechanical strength and electrical conductivity, allowing it to act as a rigid and electrically conductive matrix. As a result, the Si-TiON electrodes delivered an initial reversible capacity of 1663 mA h g-1 with remarkably enhanced capacity retention and rate performance.

7.
Nanomaterials (Basel) ; 11(8)2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34443897

RESUMO

Next-generation renewable energy sources and perovskite solar cells have revolutionised photovoltaics research and the photovoltaic industry. However, the presence of toxic lead in perovskite solar cells hampers their commercialisation. Lead-free tin-based perovskite solar cells are a potential alternative solution to this problem; however, numerous technological issues must be addressed before the efficiency and stability of tin-based perovskite solar cells can match those of lead-based perovskite solar cells. This report summarizes the development of lead-free tin-based perovskite solar cells from their conception to the most recent improvements. Further, the methods by which the issue of the oxidation of tin perovskites has been resolved, thereby enhancing the device performance and stability, are discussed in chronological order. In addition, the potential of lead-free tin-based perovskite solar cells in energy storage systems, that is, when they are integrated with batteries, is examined. Finally, we propose a research direction for tin-based perovskite solar cells in the context of battery applications.

8.
Nanomaterials (Basel) ; 11(12)2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34947770

RESUMO

Fiber-shaped solar cells (FSCs) with flexibility, wearability, and wearability have emerged as a topic of intensive interest and development in recent years. Although the development of this material is still in its early stages, bacteriophage-metallic nanostructures, which exhibit prominent localized surface plasmon resonance (LSPR) properties, are one such material that has been utilized to further improve the power conversion efficiency (PCE) of solar cells. This study confirmed that fiber-shaped dye-sensitized solar cells (FDSSCs) enhanced by silver nanoparticles-embedded M13 bacteriophage (Ag@M13) can be developed as solar cell devices with better PCE than the solar cells without them. The PCE of FDSSCs was improved by adding the Ag@M13 into an iodine species (I-/I3-) based electrolyte, which is used for redox couple reactions. The optimized Ag@M13 enhanced FDSSC showed a PCE of up to 5.80%, which was improved by 16.7% compared to that of the reference device with 4.97%.

9.
J Pharmacopuncture ; 23(4): 201-211, 2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-33408896

RESUMO

OBJECTIVES: The purpose of this study is to comprehensively review Korean domestic studies and investigate the research trends of pharmacopuncture therapy on cervical pain caused by traffic accidents. METHODS: Domestic studies between February 1999 and May 2020 from four Korean databases were searched with combinations of keywords 'cervical pain', 'traffic accident', 'whiplash injury', and 'pharmacopuncture'. RESULTS: 17 studies were selected for review, including 7 randomized controlled trials, 5 retrospective observational studies, 3 case reports, and 2 non-randomized controlled trials. Each study was reviewed by published year, study type, types of pharmacopuncture solutions, selected acupuncture points, dosage of pharmacopuncture solutions, frequency of treatment, concurrent treatments, outcome measurements, and the effectiveness of pharmacopuncture therapy. The results are as follows (1) It showed that the total number of published studies had increased slightly in the last 10 years compared to the previous decade. (2) The pharmacopuncture solutions used in the studies were in the following order Bee-Venom (), Jungsongouhyul (), Hwangryunhaedoktang () and Soyeom (). Frequently used acupuncture points were GB20, GV21, A-shi point, GV16, EX-B2, and SI15 in order. (3) The most commonly used total injection dosage was 1.0 cc at a time, and the frequency of treatment was twice a week. (4) Concurrent treatments such as acupuncture, herbal medication, physical therapy and Chuna manual therapy were performed in all 17 studies. (5) Pharmacopuncture therapy showed positive effects on cervical pain caused by traffic accidents in all 17 studies reviewed. CONCLUSION: Pharmacopuncture therapy was effective in cervical pain caused by traffic accidents in all 17 studies selected. Further studies will be needed using more larger scales and more objective data to confirm the effectiveness of pharmacopuncture therapy and to generalize its application.

10.
J Liver Cancer ; 20(2): 148-153, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37384326

RESUMO

Optimal treatments for patients with advanced hepatocellular carcinoma (HCC) are still limited and their prognosis remains dismal. Yet, there have been rare cases that have shed light on longer survival in these patients assisted by various treatments. This paper aims to present an extraordinary case of far advanced HCC that had been properly managed in spite of continuous recurrence. A patient visited the hospital with a ruptured large HCC with main portal vein tumor thrombosis but survived longer than 14 years owing to active and prompt interventions.

11.
ACS Appl Mater Interfaces ; 12(49): 54806-54814, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33216534

RESUMO

Perovskite solar cells (PSCs) have attracted immense attention owing to their outstanding power conversion efficiency (PCE). However, their counter electrodes are commonly produced by evaporating metals, such as Ag and Au, under high vacuum conditions, which make the PSCs costly, thereby limiting their large-scale production. In this study, a free-standing hybrid graphene/carbon nanotube film was carefully designed to replace noble metal PSC counter electrodes to reduce the cost and increase the stability of PSCs. A highly conductive and stable hybrid carbon thin film can be easily transferred to the various desired substrates by a simple rolling process. The PSCs with hybrid graphene/carbon nanotube films showed a high PCE of 15.36%. Moreover, the devices exhibited excellent stability and could retain 86% of their initial PCE after storage for 500 h in a high-moisture atmosphere (RH 50%). The outstanding stability of PCEs can be attributed to the efficient moisture blocking by the multilayered graphene/carbon nanotube present in the hybrid film. The thin, flexible, and easy-to-synthesize free-standing hybrid graphene/CNT film with high conductivity showed great potential for realizing the low-cost production of highly stable PSCs.

12.
Front Neurol ; 10: 563, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31231300

RESUMO

Background: Overweight contributes to type 2 diabetes mellitus (T2DM) development. Although the obesity paradox has been suggested in many vascular diseases, little information is available about stroke patients with T2DM. We investigated whether body mass index (BMI) has a differential impact on the incidence of major adverse cardiovascular events (MACE) in patients with ischemic stroke and T2DM. Methods: This retrospective study used a prospective cohort of patients with acute ischemic stroke and included consecutive patients with T2DM after excluding those with active cancer or who died within 1 month of an index stroke. We investigated the long-term risk of MACE (stroke, myocardial infarction, unstable angina, coronary revascularization procedure, and death) according to BMI. Results: Among the 1,338 patients, MACE occurred in 415 patients (31.1%) during a median follow-up of 3.6 years. Compared to the normal weight group, MACE occurred more frequently in the underweight group [adjusted hazard ratio (HR) 1.55, 95% confidence interval (CI): 1.01-2.38], but less frequently in the overweight group (adjusted HR: 0.87, 95% CI: 0.70-1.08) and obese group (adjusted HR: 0.58, 95% CI: 0.41-0.86) group. In analyses of association between BMI and each component of MACE, stroke and cardiovascular mortality indicated an L- and a U-shaped pattern, respectively. However, fatal or non-fatal stroke showed an inverse pattern, and fatal or non-fatal cardiovascular events showed a reversed J-shaped pattern. Discussions: This study showed the overall presence of the obesity paradox in stroke patients with T2DM. However, obese patients had different risks of cardiovascular events and stroke.

13.
ACS Appl Mater Interfaces ; 11(17): 16223-16232, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30969110

RESUMO

A high-performance, flexible, and transparent heater based on a hybrid of dry-spun carbon nanotubes (CNT), which is pulled out directly from a super vertically aligned CNT forest, and graphene is fabricated. The electrical, optical, and electromechanical properties of two different kinds of hybrid devices, graphene above or below the CNT film, and simple CNT film heating devices that are made of one or two layers of CNTs, are studied. The results prove that the hybrid structured film heaters are superior to the simple CNT film heaters. The simple single-layer CNT film and double-layer CNT film heaters attain maximum temperatures of 48 and 64 °C with transmittances of 73 and 64% at a wavelength of 550 nm, respectively, whereas the single-layer CNT sheet/graphene/PET and graphene/single-layer CNT sheet/PET hybrid heaters attain maximum temperatures of 81 and 85 °C with transmittances of 68 and 71%, respectively. The 10 000 bending cycle test suggests that the graphene/single-layer CNT sheet/PET heater has good mechanical and thermal stability. Further, defrost test and portable heating with a 9 V battery prove the possibility of using the hybrid heater for vehicle defrosting, portable heating, and wearable devices.

14.
Sci Rep ; 8(1): 5747, 2018 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-29636488

RESUMO

Through the direct decomposition of an Al precursor ink AlH3{O(C4H9)2}, we fabricated an Al-coated conductive fiber filter for the efficient electrostatic removal of airborne particles (>99%) with a low pressure drop (~several Pascals). The effects of the electrical and structural properties of the filters were investigated in terms of collection efficiency, pressure drop, and particle deposition behavior. The collection efficiency did not show a significant correlation with the extent of electrical conductivity, as the filter is electrostatically charged by the metallic Al layers forming electrical networks throughout the fibers. Most of the charged particles were collected via surface filtration by Coulombic interactions; consequently, the filter thickness had little effect on the collection efficiency. Based on simulations of various fiber structures, we found that surface filtration can transition to depth filtration depending on the extent of interfiber distance. Therefore, the effects of structural characteristics on collection efficiency varied depending on the degree of the fiber packing density. This study will offer valuable information pertaining to the development of a conductive metal/polymer composite air filter for an energy-efficient and high-performance electrostatic filtration system.

15.
Clin Ther ; 40(5): 752-761.e2, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29729957

RESUMO

PURPOSE: The purpose of this study was to compare the adherence of the glimepiride/metformin sustained release (GM-SR) once-daily fixed-dose combination and glimepiride/metformin immediate release (GM-IR) BID fixed-dose combination in type 2 diabetes therapies. METHODS: An open-label, randomized, multicenter, parallel-group study was conducted at 11 hospitals in the Republic of Korea. A total of 168 patients with type 2 diabetes treated with >4 mg of glimepiride and 1000 mg of metformin by using free or fixed-dose combination therapy for at least 2 weeks were enrolled. Patients were randomized to receive GM-SR 4/1000 mg once-daily or GM-IR 2/500 mg BID for 24 weeks. Adherence was compared by using the Medication Event Monitoring System (MEMS). FINDINGS: A significant difference in adherence was observed between the 2 groups. Overall adherence, defined by the number of container openings divided by the number of prescribed doses, was 91.7% in the GM-SR group and 88.6% in the GM-IR group (P < 0.001). The percentage of treatment days with the correct number of doses taken was 85.3% in the GM-SR group and 75.1% in the GM-IR group (P < 0.001). The percentage of missed doses was 11.7% in the GM-SR group and 15.3% in the GM-IR group (P < 0.001). The percentage of doses taken in the correct time window and therapeutic coverage were higher in the GM-SR group (P < 0.001). There was no significant difference in glycosylated hemoglobin changes or number of adverse events between the 2 groups. A total of 168 patients randomized to receive GM-SR once daily (86 patients) or GM-IR twice daily (82 patients). Mean Age were 57.8 ± 9.6 years old. Male : female ratio was 47.6 : 52.4 %. Body mass index were 66.3 ± 12.0 kg/m2, Diabetes duration were 10.5 ± 6.6 years. IMPLICATIONS: This study showed that patient adherence with GM-SR once daily was significantly better than with GM-IR BID. ClinicalTrials.gov identifier: NCT01620489.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Metformina/administração & dosagem , Compostos de Sulfonilureia/administração & dosagem , Idoso , Índice de Massa Corporal , Preparações de Ação Retardada/uso terapêutico , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/uso terapêutico , Masculino , Adesão à Medicação , Metformina/uso terapêutico , Pessoa de Meia-Idade , República da Coreia
16.
J Mov Disord ; 10(3): 154-157, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28704983

RESUMO

Dyskinesia hyperpyrexia syndrome is a rare medical emergency in Parkinson's disease. It is characterized by continuous dyskinesia associated with hyperthermia, rhabdomyolysis, and alteration of the mental state. We present the case of a 74-year-old woman who presented with recurrent dyskinesia hyperpyrexia syndrome. Although some provocation factors and clinical manifestations seem to be shared with parkinsonism hyperpyrexia syndrome, a clear distinction in management should be considered.

17.
ACS Appl Mater Interfaces ; 9(20): 17499-17507, 2017 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-28471157

RESUMO

Wearable pressure sensors are crucial building blocks for potential applications in real-time health monitoring, artificial electronic skins, and human-to-machine interfaces. Here we present a highly sensitive, simple-architectured wearable resistive pressure sensor based on highly compliant yet robust carbon composite conductors made of a vertically aligned carbon nanotube (VACNT) forest embedded in a polydimethylsiloxane (PDMS) matrix with irregular surface morphology. A roughened surface of the VACNT/PDMS composite conductor is simply formed using a sandblasted silicon master in a low-cost and potentially scalable manner and plays an important role in improving the sensitivity of resistive pressure sensor. After assembling two of the roughened composite conductors, our sensor shows considerable pressure sensitivity of ∼0.3 kPa-1 up to 0.7 kPa as well as stable steady-state responses under various pressures, a wide detectable range of up to 5 kPa before saturation, a relatively fast response time of ∼162 ms, and good reproducibility over 5000 cycles of pressure loading/unloading. The fabricated pressure sensor can be used to detect a wide range of human motions ranging from subtle blood pulses to dynamic joint movements, and it can also be used to map spatial pressure distribution in a multipixel platform (in a 4 × 4 pixel array).

18.
ACS Appl Mater Interfaces ; 9(2): 1770-1780, 2017 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-27996234

RESUMO

A highly stretchable, low-cost strain sensor was successfully prepared using an extremely cost-effective ionic liquid of ethylene glycol/sodium chloride. The hysteresis performance of the ionic-liquid-based sensor was able to be improved by introducing a wavy-shaped fluidic channel diminishing the hysteresis by the viscoelastic relaxation of elastomers. From the simulations on visco-hyperelastic behavior of the elastomeric channel, we demonstrated that the wavy structure can offer lower energy dissipation compared to a flat structure under a given deformation. The resistance response of the ionic-liquid-based wavy (ILBW) sensor was fairly deterministic with no hysteresis, and it was well-matched to the theoretically estimated curves. The ILBW sensors exhibited a low degree of hysteresis (0.15% at 250%), low overshoot (1.7% at 150% strain), and outstanding durability (3000 cycles at 300% strain). The ILBW sensor has excellent potential for use in precise and quantitative strain detections in various areas, such as human motion monitoring, healthcare, virtual reality, and smart clothes.


Assuntos
Líquidos Iônicos/química , Elasticidade , Elastômeros , Humanos , Íons , Movimento (Física)
19.
Ann Nucl Med ; 17(5): 411-4, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12971642

RESUMO

A 27-year-old female patient was admitted to our hospital with a history of leg pain and mass. She had a benign osteoblastoma in right tibia. Resection of the tumor without treatment by vitamin D antagonist resulted in rapid cure of the osteomalacia. Bone scintigraphy with Tc-99m MDP revealed multiple hot uptakes in initial scan, and follow up scan showed a clear resolution of the lesions.


Assuntos
Neoplasias Ósseas/complicações , Neoplasias Ósseas/diagnóstico por imagem , Osteoblastoma/complicações , Osteoblastoma/diagnóstico por imagem , Osteomalacia/diagnóstico por imagem , Osteomalacia/etiologia , Medronato de Tecnécio Tc 99m , Adulto , Neoplasias Ósseas/secundário , Diagnóstico Diferencial , Feminino , Humanos , Cintilografia , Compostos Radiofarmacêuticos , Tíbia/diagnóstico por imagem
20.
ACS Appl Mater Interfaces ; 6(22): 20423-9, 2014 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-25384110

RESUMO

This study details the development of a large-area, three-dimensional (3D), plasmonic integrated electrode (PIE) system. Vertically aligned multiwalled carbon nanotube (VA-MWNT) electrodes are grown and populated with self-assembling silver nanoparticles via thermal evaporation. Due to the geometric and surface characteristics of VA-MWNTs, evaporated silver atoms form nanoparticles approximately 15-20 nm in diameter. The nanoparticles are well distributed on VA-MWNTs, with a 5-10 nm gap between particles. The size and gap of the self-assembled plasmonic nanoparticles is dependent upon both the length of the MWNT and the thickness of the evaporated silver. The wetting properties of water of the VA-MWNT electrodes change from hydrophilic (∼70°) to hydrophobic (∼120°) as a result of the evaporated silver. This effect is particularly pronounced on the VA-MWNT electrodes with a length of 1 µm, where the contact angle is altered from an initial 8° to 124°. Based on UV-visible spectroscopic analysis, plasmonic resonance of the PIE systems occurs at a wavelength of approximately 400 nm. The optical behavior was found to vary as a function of MWNT length, with the exception of MWNT with a length of 1 µm. Using our PIE systems, we were able to obtain clear surface-enhanced Raman scattering (SERS) spectra with a detection limit of ∼10 nM and an enhancement factor of ∼10(6). This PIE system shows promise for use as a novel electrode system in next-generation optoelectronics such as photovoltaics, light-emitting diodes, and solar water splitting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA