Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 30(4): 1656-1667, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36813934

RESUMO

OBJECTIVES: To assess the diagnostic performances of CZT myocardial perfusion reserve (MPR) for the detection of territories with simultaneous impaired coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) in patients without obstructive coronary artery disease. METHODS: Patients were prospectively included before being referred for coronary angiography. All patients underwent CZT MPR before invasive coronary angiography (ICA) and coronary physiology assessment. Rest and dipyridamole-induced stress myocardial blood flow (MBF) and MPR were quantified using 99mTc-SestaMIBI and a CZT camera. Fractional flow reserve (FFR), Thermodilution CFR, and IMR were assessed during ICA. RESULTS: Between December 2016 and July 2019, 36 patients were included. 25/36 patients presented no obstructive coronary artery disease. A complete functional assessment was performed in 32 arteries. No territory presented a significant ischemia on CZT myocardial perfusion imaging. A moderate yet significant correlation was observed between regional CZT MPR and CFR (r = 0.4, P = .03). Sensitivity, specificity, positive and negative predictive value, and accuracy of regional CZT MPR versus the composite invasive criterion (impaired CFR and IMR) were 87 [47% to 99%], 92% [73% to 99%], 78% [47% to 93%], 96% [78% to 99%], and 91% [75% to 98%], respectively. All territories with a regional CZT MPR ≤ 1.8 showed a CFR < 2. Regional CZT MPR values were significantly higher in arteries with CFR ≥ 2 and IMR < 25 (negative composite criterion, n = 14) than in those with CFR < 2 and IMR ≥ 25 (2.6 [2.1 to 3.6] versus 1.6 [1.2 to 1.8]), P < .01). CONCLUSION: Regional CZT MPR presented excellent diagnostic performances for the detection of territories with simultaneously impaired CFR and IMR reflecting a very high cardiovascular risk in patients without obstructive coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Projetos Piloto , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Microcirculação/fisiologia , Angiografia Coronária , Perfusão , Imagem de Perfusão do Miocárdio/métodos
2.
Eur J Nucl Med Mol Imaging ; 49(3): 809-820, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34417856

RESUMO

PURPOSE: Coronary microvascular dysfunction (CMVD) plays a major role in the occurrence of cardiovascular events (CVE). We recently suggested the clinical potential of myocardial perfusion entropy (MPE) quantification from SPECT myocardial perfusion images (MPI) for the prognosis of CVE occurrence. We hypothesized that the quantification of MPE from SPECT MPI would allow the assessment of CMVD-related MPE variations in a preclinical model of type 2 diabetes (T2D) including treatment with the anti-diabetic incretin liraglutide (LIR). METHODS: Optimal conditions for the preclinical quantification of MPE using 201Tl SPECT MPI were determined in rats with a T2D-like condition induced by a high-fat diet and streptozotocin injection (feasibility study, n = 43). Using such conditions, echocardiography and post-mortem LV capillary density evaluation were then used in order to assess the effect of LIR and the ability of MPE to assess CMVD (therapeutic study, n = 39). RESULTS: The feasibility study identified dobutamine stress and acute NO synthase and cyclooxygenase inhibition as optimal conditions for the quantification of MPE, with significant increases in MPE being observed in T2D animals (P < 0.01 vs controls). In the therapeutic study, T2D rats were hyperglycemic (5.5 ± 0.5 vs 1.1 ± 0.3 g/L for controls, P < 0.001) and had a significantly lower left ventricular ejection fraction (LVEF) (65 ± 4% vs 74 ± 9%, P < 0.01) and LV capillary density (2400 ± 300 vs 2800 ± 600 mm-3, P < 0.05). LIR partially restored glycemia (3.9 ± 0.6 g/L, P < 0.05 vs controls and T2D), totally prevented LVEF impairment (72 ± 7%, P = NS vs CTL), with no significant effect on capillary density. MPE was significantly increased in T2D rats (7.6 ± 0.5 vs 7.1 ± 0.5, P < 0.05), with no significant improvement in T2D-LIR rats (7.4 ± 0.4, P = NS vs controls and T2D). CONCLUSION: MPE quantification allowed the preclinical noninvasive assessment of CMVD. Both MPE and capillary density quantification suggested that LIR did not improve T2D-induced CMVD. The relevance of MPE for CMVD assessment warrants further clinical investigation.


Assuntos
Diabetes Mellitus Tipo 2 , Imagem de Perfusão do Miocárdio , Animais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Entropia , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Ratos , Roedores , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda/fisiologia
3.
J Nucl Cardiol ; 29(4): 1647-1656, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33988809

RESUMO

AIMS: The objective of this study was to determine the accuracy of right ventricular function (RVF) assessed by Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography (CZT-ERNA). METHODS AND RESULTS: Twenty-one consecutive patients with cardiomyopathy (aged 54 ± 19 years; 62% male) were included. RV ejection fraction (EF) and volumes were analyzed by CZT-ERNA and compared with values obtained by cardiac magnetic resonance imaging (CMR). Mean values were not different between CZT-ERNA and MRI for RVEF (48.1 ± 10.4% vs 50.8 ± 10.0%; P = .23). Significant correlations (P < .0001) were observed between CZT-ERNA and MRI for RVEF, RV end-diastolic volume, and end-systolic volume (r = 0.81, r = 0.93, and r = 0.96, respectively). Bland-Altman analysis showed a mean difference (bias) between CZT-ERNA and MRI for RVEF of -2.69% (95% CI - 5.35 to - 0.42) with good agreement between the 2 techniques (limits of agreement, -14.3 to 8.99). Intraobserver and interobserver reproducibility of RVF measured by CZT-ERNA was high. CONCLUSION: CZT-ERNA provides accurate, reproducible assessment of RVF and appears as a good alternative to cardiac magnetic resonance for the evaluation of the magnitude of RVF in patients with cardiomyopathy.


Assuntos
Cardiomiopatias , Imagem do Acúmulo Cardíaco de Comporta , Cádmio , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Zinco
4.
Eur J Nucl Med Mol Imaging ; 48(6): 1813-1821, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33219463

RESUMO

PURPOSE: Risk stratification of patients with type 2 diabetes mellitus (T2D) remains suboptimal. We hypothesized that myocardial perfusion entropy (MPE) quantified from SPECT myocardial perfusion images may provide incremental prognostic value in T2D patients independently from myocardial ischemia. METHODS: T2D patients with very high and high cardiovascular risk were prospectively included (n = 166, 65 ± 12 years). Stress perfusion defect was quantified by visual evaluation of SPECT MPI. SPECT MPI was also used for the quantification of rest and stress MPE. The primary end point was major adverse cardiac events (MACEs) defined as cardiac death, myocardial infarction (MI), and myocardial revascularization > 3 months after SPECT. RESULTS: Forty-four MACEs were observed during a 4.6-year median follow-up. Significant differences in stress MPE were observed between patients with and without MACEs (4.19 ± 0.46 vs. 3.93 ± 0.40; P ≤ .01). By Kaplan-Meier analysis, the risk of MACEs was significantly higher in patients with higher stress MPE (log-rank P ≤ 01). Stress MPE and stress perfusion defect (SSS ≥ 4) were significantly associated with the risk of MACEs (hazard ratio 2.77 and 2.06, respectively, P < .05 for both) after adjustment for clinical and imaging risk predictors as identified from preliminary univariate analysis. MPE demonstrated incremental prognostic value over clinical risk factors, stress test EKG and SSS as evidenced by nested models showing improved Akaike information criterion (AIC), reclassification (global continuous net reclassification improvement [NRI]: 63), global integrated discrimination improvement (IDI: 6%), and discrimination (change in c-statistic: 0.66 vs 0.74). CONCLUSIONS: Stress MPE provided independent and incremental prognostic information for the prediction of MACEs in diabetic patients. TRIAL REGISTRATION NUMBER: NCT02316054 (12/12/2014).


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Imagem de Perfusão do Miocárdio , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico por imagem , Entropia , Teste de Esforço , Humanos , Perfusão , Prognóstico , Medição de Risco , Fatores de Risco , Tomografia Computadorizada de Emissão de Fóton Único
5.
Eur J Nucl Med Mol Imaging ; 48(13): 4331-4338, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34169368

RESUMO

PURPOSE: The coronavirus disease 2019 (COVID-19) pandemic reshaped the usual risk: benefit equilibrium that became a trade-off between the infection exposure risk for the patient (and for staff) and the risk associated with delaying or cancelling the nuclear medicine examination. This study aimed at quantifying the impact of the first COVID-19 lockdown in France on nuclear medicine examination volume together with volume of examination cancellation and non-attendance. METHODS: We retrospectively assessed the volume of planned examinations from 1 month before to 1 month after the first lockdown in French high-volume nuclear medicine departments (NMD) sharing the same information management system including both university hospitals, UH (n = 7), and cancer centres, CC (n = 2). RESULTS: The study enrolled 31,628 consecutive patients referred for a nuclear medicine examination performed or not (NMEP or NMEnP). The total volume of NMEP significantly dropped by 43.4% between the 4 weeks before and after the starting of the lockdown. The comparison of the percentage of NMEP and NMEnP between UH and CC is significantly different (p < 0.001). The percentage of NMEP during the study was 67.9% in UH vs 84.7% in CC. Percentages of NMEnP in UH and CC were due respectively to cancellation by the patient (14.9 vs 7.4%), cancellation by the NMD (9.5 vs 3.4%), cancellation by the referring physician (5.1 vs 4.4%) and non-attender patients (2.7 vs 0.2%). CONCLUSION: The study underlines the public health issue caused by COVID-19 above the pandemic itself and should be useful in preparing for potential resource utilisation and staffing requirements.


Assuntos
COVID-19 , Medicina Nuclear , Controle de Doenças Transmissíveis , França/epidemiologia , Humanos , Estudos Retrospectivos , SARS-CoV-2
6.
Eur J Nucl Med Mol Imaging ; 46(10): 2042-2050, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31321484

RESUMO

PURPOSE: To determine whether the assessment of regional wall thickening (WT) in addition to myocardial perfusion from stress supine acquisitions could compensate for the lack of prone acquisition and the corresponding decrease in the diagnostic performance of SPECT myocardial perfusion imaging (MPI) in patients with known or suspected coronary artery disease (CAD). METHODS: The study group comprised 41 patients (123 vessels) with known or suspected CAD prospectively recruited for systematic prone and supine 201Tl stress SPECT MPI. The diagnostic performance of SPECT MPI was determined for various image sets including nongated supine images (supine NG), nongated combined prone and supine images (prone and supine NG) and gated supine images, allowing WT evaluation from NG images in addition to perfusion (supine NG + WT) using invasive coronary angiography and fractional flow reserve as the gold standards. RESULTS: The rate of false positives was significantly higher among the supine NG images (20.8%) than among either the prone and supine NG or the supine NG + WT images (3.3% and 2.7%, respectively, P < 0.05 vs. supine NG). Consequently, specificity was higher for the prone and supine NG images than for the supine NG images (96.1% vs. 76.1%, P < 0.01) and was highest for the supine NG + WT images (96.8%, P not significant vs. prone and supine NG), without significant differences in sensitivity (80.0%, 86.6% and 73.3%, respectively, P not significant for all comparisons). CONCLUSION: The diagnostic performance of supine stress SPECT MPI is improved when WT assessment of ischaemic segments is used as an additional diagnostic criterion to values not significantly different from those with combined prone and supine acquisitions.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Posicionamento do Paciente/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Imagem de Perfusão do Miocárdio/normas , Posicionamento do Paciente/normas , Valor Preditivo dos Testes , Decúbito Ventral , Compostos Radiofarmacêuticos , Semicondutores , Decúbito Dorsal , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/normas
7.
J Nucl Cardiol ; 25(3): 1017-1022, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29209950

RESUMO

Coronary microvascular dysfunction has recently emerged as a major independent prognostic factor and can be invasively assessed by coronary flow reserve (CFR) and the index of microvascular resistance (IMR). The incremental prognostic value of myocardial ischemia from SPECT myocardial perfusion imaging (MPI) over clinical characteristics, cardiac risk factors, and stress test data for the prediction of hard cardiac events (myocardial infarction and cardiac death) has been well demonstrated over the last two decades regardless of the absence or presence of epicardial CAD. Recently developed semi-conductor, cardiac-dedicated cameras allow for decreased acquisition times and systematic procubitus and decubitus acquisitions thereby limiting the occurrence of false positives historically attributable to artefactual motion, attenuation, and digestive artifacts. It is therefore likely that pathophysiological causes rather than acquisition artifacts might underlie SPECT perfusion abnormalities. Here, we report four representative examples of patients presenting with ischemia in the setting of no obstructive CAD and normal fractional flow reserve together with elevated IMR and low CFR. The results indicate that ischemia from SPECT MPI could result from microvascular dysfunction in patients without obstructive CAD and should be considered as a prognostic factor for hard cardiac events.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/etiologia , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia
8.
J Pharm Biomed Anal ; 246: 116224, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759321

RESUMO

Cardiovascular diseases, including fatal myocardial infarctions from atheromatous plaques, are the primary global mortality cause. Detecting stenotic atheromatous plaques is possible through coronary angiography, but vulnerable plaques with eccentric remodeling are undetectable with current diagnostic methods. Addressing this challenge, our group developed a radiopharmaceutical drug targeting vascular cell adhesion molecule 1 (VCAM-1), radiolabeled with technetium-99m. Given the absence of a monograph in the European Pharmacopoeia, and in order to draft the investigational medicinal product documentation, analytical methods had to be validated by high performance liquid chromatography (HPLC) and thin layer chromatography (TLC) to determine the radiochemical purity (RCP) of 99mTc-cAbVCAM1-5. This study therefore presents the results of the validation of analytical methods obtained in this context. The method validation followed the European Association of Nuclear Medicine (EANM) recommendations adapted from ICH Q2(R1), ensuring conformity with specificity, accuracy, repeatability and intermediate precision, linearity, robustness, quantification limit (LoQ), and range criteria. Regarding the results of specificity, both HPLC and TLC methods demonstrated excellent separation of 99mTc-cAbVCAM1-5 from impurities 99mTcO4-. Accuracy results indicated recovery percentages within the range of 99.52-101.40% for the HPLC and 99.51-101.97% for TLC, ensuring reliable measurements for each concentration of 99mTcO4-. Precision of the methods was validated by assessing repeatability and intermediate precision. Linearity was determined over the usual concentrations range and the correlation coefficient was greater than 0.99 for both methods. The limit of quantification was measured by diluting the 99mTcO4- to obtain a signal-to-noise ratio of around 10:1. Under these conditions, we obtained an LOQ of 2.10 MBq/mL for HPLC and 2Mbq/mL for TLC. In conclusion, the analytical methods developed in this study comply with EANM recommendations. This therefore allows us to correctly assess the radiochemical purity of 99mTc-cAbVCAM1-5, a new radiotracer targeting inflammation in vulnerable plaques.


Assuntos
Compostos Radiofarmacêuticos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Camada Fina/métodos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/análise , Reprodutibilidade dos Testes , Tecnécio/química , Tecnécio/análise , Compostos de Organotecnécio/química , Compostos de Organotecnécio/análise
9.
Eur J Hosp Pharm ; 30(6): 347-352, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-34972687

RESUMO

OBJECTIVES: Automation of parenteral nutrition (PN) preparation is nowadays a recommended practice in order to reduce human errors and thus improve the safety and accuracy of the finished product. Other benefits of automation may include full documentation of preparation and a reduction in personnel requirements or staff injuries. The market of automation compounding presents different automated compounding devices (ACDs). The aim of this study is to compare the technical characteristics of ACDs by carrying out four specific challenges. METHODS: Three ACDs: Two piston pumps with ACD 1: MediMix Multi 4120R (Impromediform) and ACD 2: Mibmix Compounder C12 (Hemedis), and one peristaltic pump ACD 3: ExactaMix Compounder EM2400 (Baxter) were assessed in a pharmaceutical manufacturing unit within a controlled atmosphere area, under horizontal laminar flow hood (LFH) according to four tests: volumetric accuracy, flush volume, smoke test, and a production test with three configurations of PN bags. For this test, a PN bag was considered accepted when all quality controls (weight, molar concentration of sodium, potassium and calcium) were fulfilled. RESULTS: The maximum relative biases found for the different ACDs were heterogeneous. ACD 1 had the best volumetric accuracy with respect to supplier specifications and for extreme volumes (0.2 mL). Evaluation of the flushing volume allowed the validation of 50 mL volumes for ACD 1 and ACD 3. The smoke test was only conclusive for ACD 1 under a horizontal LFH. The percentage of PN bags accepted were 98.8% for ACD 1, 70% for ACD 2%, and 95.5% for ACD 3. CONCLUSION: This study compared three ACDs according to four relevant and specific tests. Based on the data acquired, we conclude that ACD 1 is the most accurate, has the lowest flushing volume, is suitable for use in a LFH, and achieves the best results in the production test.


Assuntos
Nutrição Parenteral , Serviço de Farmácia Hospitalar , Humanos , Cálcio , Automação , Controle de Qualidade
10.
Eur J Hosp Pharm ; 2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37068926

RESUMO

OBJECTIVES: On the basis of its safety and accuracy, automation is recommended for parenteral nutrition (PN). The aim of this study was to highlight the changes in practices related to the automation of PN and to perform a cost study comparing manual vs automated production costs. METHODS: We conducted a micro-costing study using 1 year of manual production data for adult, neonatal and paediatric PN bagsat a hospital. We used the data to estimate the costs of automating the production process for adult, neonatal and paediatric bags. RESULTS: Major modification to the PN production process resulted in: rationalisation of raw materials, computerisation and optimisation of human needs. Switching from a manual to an automated process reduced the cost of neonatal/paediatric custom bags (€130.73 vs €124.58) and semi-custom bags (€172.08 vs €166.86); but increased the cost of adult bags (€93.06 vs €127.92). CONCLUSIONS: The changes resulting from the automation and revision of the production process globally increased annual expenditures by approximately 9.7%. However, automation minimised the risk of misproduction, bag contamination, and led to a more secure production process that reduced risks incurred by the teams. In view of the gain in patient and staff safety (linked to the use of an automated compounding device) the moderate economic impact (<10%) should not deter the automation of PN production circuits.

11.
EJNMMI Radiopharm Chem ; 8(1): 34, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37882937

RESUMO

BACKGROUND: The aim of this brief communication is to highlight the potential bacteriological risk linked to the processes control of radiopharmaceutical preparations made in a radiopharmacy laboratory. Survival rate of Pseudomonas aeruginosa (ATCC: 27853) or Staphylococcus aureus (ATCC: 25923) or Staphylococcus epidermidis (ATCC: 1228) in multidose technetium-99 m solution was studied. RESULTS: Depending on the nature and level of contamination by pathogenic bacteria, the lethal effect of radioactivity is not systematically observed. We found that P. aeruginosa was indeed affected by radioactivity. However, this was not the case for S. epidermidis, as the quantity of bacteria found in both solutions (radioactive and non-radioactive) was rapidly reduced, probably due to a lack of nutrients. Finally, the example of S. aureus is an intermediate case where we observed that high radioactivity affected the bacteria, as did the absence of nutrients in the reaction medium. The results were discussed in the light of current practices on the sterility test method, which recommends waiting for radioactivity to decay before carrying out the sterility test. CONCLUSION: In terms of patient safety, the results run counter to current practice and the latest EANM recommendation of 2021 that radiopharmaceutical preparations should be decayed before sterility testing.

12.
Emerg Microbes Infect ; 12(1): 2148563, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36458570

RESUMO

Subacute sclerosing panencephalitis (SSPE) is a late-onset and fatal viral disease caused by persistent infection of the central nervous system by measles virus (MeV). We present the case of a 10-year-old child from South Asia affected by SSPE, stabilized with a combination of intrathecal interferon-α2b (INF-α2b) injections and oral inosiplex and how we continued the treatment when inosiplex was commercially stopped worldwide.


Assuntos
Inosina Pranobex , Panencefalite Esclerosante Subaguda , Humanos , Criança , Inosina Pranobex/uso terapêutico , Panencefalite Esclerosante Subaguda/tratamento farmacológico , Interferon-alfa/uso terapêutico , Ásia Meridional
13.
EJNMMI Radiopharm Chem ; 8(1): 32, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37856008

RESUMO

BACKGROUND: Despite the development of positron emission tomography (PET), single photon emission computed tomography (SPECT) still accounts for around 80% of all examinations performed in nuclear medicine departments. The search for new radiotracers or chelating agents for Technetium-99m is therefore still ongoing. O-TRENSOX and O-TRENOX two synthetic siderophores would be good candidates for this purpose as they are hexadentate ligands based on the very versatile and efficient 8-hydroxyquinoline chelating subunit. First, the radiolabeling of O-TRENOX and O-TRENSOX with 99mTc was investigated. Different parameters such as the quantity of chelating agent, type of reducing agent, pH and temperature of the reaction mixture were adjusted in order to find the best radiolabeling conditions. Then an assessment of the partition coefficient by measuring the distribution of each radiosynthesized complex between octanol and phosphate-buffered saline was realized. The complex's charge was evaluated on three different celluloses (neutral, negatively charged P81 and positively charged DE81), and finally in vivo studies with biodistribution and SPECT imaging of [99mTc]Tc-O-TRENOX and [99mTc]Tc-O-TRENSOX were performed. RESULTS: The radiolabeling studies showed a rapid and efficient complexation of 99mTc with both chelating agents. Using tin pyrophosphate as the reducing agent and a minimum of 100 nmol of ligand, we obtained the [99mTc]Tc-O-TRENOX complex with a radiochemical purity of more than 98% and the [99mTc]Tc-O-TRENSOX complex with one above 97% at room temperature within 5 min. [99mTc]Tc-O-TRENOX complex was lipophilic and neutral, leading to a hepatobiliary elimination in mice. On the contrary, the [99mTc]Tc-O-TRENSOX complex was found to be hydrophilic and negatively charged. This was confirmed by a predominantly renal elimination in mice. CONCLUSIONS: These encouraging results allow us to consider the O-TRENOX/99mTc and O-TRENSOX/99mTc complexes as serious candidates for SPECT imaging chelators. This study should be continued by conjugating these tris-oxine ligands to peptides or antibodies and comparing them with the other bifunctional agents used with Tc.

14.
Pharmaceuticals (Basel) ; 15(5)2022 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-35631349

RESUMO

Prostate Specific Membrane Antigen (PSMA) is a highly relevant target in nuclear medicine due to its overexpression in prostate cancer. The 68Ga/177Lu-PSMA-1 combination is a theranostic agent for the detection and treatment of tumors overexpressing the PSMA target. Specifically, 177Lu-PSMA-1 is used in the treatment of castration-resistant prostate cancer that is ineffective or intolerant to the latest generation of chemotherapy and/or hormone therapy. This radiopharmaceutical is manufactured in a radiopharmaceutical synthesizing unit and must pass a quality control where the radiochemical purity (RCP) is assessed prior to release of the batch. RCP evaluation is performed by high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC). Since there is no monograph for 177Lu-PSMA-1 in the European Pharmacopoeia, we validate the analytical methods according to the EANM recommendations adapted from ICH Q2. Specificity, linearity, accuracy, precision, intermediate precision, limit of quantification (LOQ) and robustness were described for HPLC and TLC in this study. The results obtained demonstrated the robustness and reliability of the HPLC and TLC analytical methods for the evaluation of the RCP of 177Lu-PSMA-1.

15.
Eur J Pharm Sci ; 179: 106275, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35987326

RESUMO

Automated compounding device (ACD) are increasingly used for parenteral nutrition (PN) bag production, and their acquisition must be sufficiently thought. The law requires the qualification of these ACD, but did not specify the tests to be performed. The quality by design (QbD) risk based approach allowed to define the quality target product profile in order to acquire the best ACD for each unit, and thanks a risk analysis permitted to define the critical quality attributes (CQA). These CQA will allowed to define tests performed during qualification. The ACD qualified was a 12 pump volumetric system. The CQA for PN bags consisted in sterile, precisely and accurately production with enough stability. During operational qualification volumetric accuracy test was performed, and during the performance qualification: flush volume, media fill, microbiological integrity of environment, sterility of control bag and production test were performed. At the end, all tests were conclusive (excepted for some results mostly due to analytical bias) and the ACD was considered to produce sterile bags in a control environment, precisely (relative standard deviation < 4%) and accurately (mean bias < 1% for weight and < 7% for other controls) with a sufficient stability. The QbD risk based approach allowed to acquire the best ACD for our need, and qualify relevant elements regarding the production process.


Assuntos
Nutrição Parenteral , Medição de Risco , Composição de Medicamentos
16.
Cancers (Basel) ; 13(5)2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33801382

RESUMO

NeoB is a radiotracer targeting the gastrin-releasing peptide receptor (GRPR), a G-protein-coupled receptor expressed in various cancers. The aim of the present study was to evaluate the biodistribution and efficacy of this new therapeutic agent in Gastrointestinal Stromal Tumors (GIST). Eighty-two SCID mice bearing GIST-882 tumors were employed. [177Lu]Lu-NeoB biodistribution was evaluated up to seven days by organ sampling (200 pmol/0.8 MBq, i.v.). For efficacy evaluation, mice received either saline, 400 pmol or 800 pmol of [177Lu]Lu-NeoB (37MBq, 1/w, 3 w, i.v.). SPECT/CT imaging was performed at 24 h, and tumor volume was determined up to 100 days. Elevated and specific [177Lu]Lu-NeoB uptake was found in the GIST tumor, as demonstrated by in vivo competition (19.1 ± 3.9 %ID/g vs. 0.3 ± 0.1 %ID/g at 4h). [177Lu]Lu-NeoB tumor retention (half-life of 40.2 h) resulted in elevated tumor-to-background ratios. Tumor volumes were significantly reduced in both treated groups (p < 0.01), even leading to complete tumor regression at the 400 pmol dose. [177Lu]Lu-NeoB exhibited excellent pharmacokinetics with elevated and prolonged tumor uptake and low uptake in non-target organs such as pancreas. The potential of this new theragnostic agent in different indications, including GIST, is under evaluation in the FIH [177Lu]Lu-NeoB clinical trial.

17.
Cancer Imaging ; 20(1): 58, 2020 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787923

RESUMO

BACKGROUND: To assess whether whole-body (WB) bone SPECT/CT provides additional diagnostic information over [18F]-FCH PET/CT for the detection of bone metastases in the setting of prostate cancer biochemical recurrence (PC-BR). METHODS: Patients referred for a PC-BR and whom benefited from a WB bone SPECT/CT and FCH PET/CT were retrospectively included. Tests were classified as positive, equivocal, or negative for bone metastases. A best valuable comparator (BVC) strategy including imaging and follow-up data was used to determine the metastatic status in the absence of systematic histological evaluation. RESULTS: Between January 2011 and November 2017, 115 consecutive patients with a PC-BR were evaluated. According to the BVC, 30 patients had bone metastases and 85 patients did not present with bone lesions. The sensitivity, specificity, positive and negative predictive values were respectively 86.7% [69.3-96.2], 98.8% [93.6-100.0], 96.3% [78.7-99.5], and 95.5% [89.4-98.1] for WB bone SPECT/CT and 93.3% [77.9-99.2], 100.0% [95.8-100.0], 100.0 and 97.7% [91.8-99.4] for FCH PET/CT. There was no significant difference in diagnostic accuracy of bone metastases between WB Bone SPECT/CT (AUC 0.824 [0.74-0.90]) and FCH PET/CT (AUC 0.829 [0.75-0.90], p = 0.41). CONCLUSION: Despite good performances for the diagnosis of bone metastases in PC-BR, WB bone SPECT/CT does not provide additive diagnostic information over concomitant FCH PET/CT.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Colina/análogos & derivados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Neoplasias da Próstata/patologia , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Idoso , Neoplasias Ósseas/secundário , Humanos , Masculino , Pessoa de Meia-Idade
18.
Cancers (Basel) ; 11(7)2019 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-31340603

RESUMO

Recent progress in breast cancer research has led to the identification of Vascular Cell Adhesion Molecule-1 (VCAM-1) as a key actor of metastatic colonization. VCAM-1 promotes lung-metastases and is associated with clinical early recurrence and poor outcome in triple negative breast cancer (TNBC). Our objective was to perform the in vivo imaging of VCAM-1 in mice models of TNBC. The Cancer Genomic Atlas (TCGA) database was analyzed to evaluate the prognostic role of VCAM-1 in TNBC. MDA-MB-231 (VCAM-1+) and control HCC70 (VCAM-1-) TNBC cells were subcutaneously xenografted in mice and VCAM-1 expression was assessed in vivo by single-photon emission computed tomography (SPECT) imaging using 99mTc-cAbVCAM1-5. Then, MDA-MB-231 cells were intravenously injected in mice and VCAM-1 expression in lung metastasis was assessed by SPECT imaging after 8 weeks. TCGA analysis showed that VCAM-1 is associated with a poor prognosis in TNBC patients. In subcutaneous tumor models, 99mTc-cAbVCAM1-5 uptake was 2-fold higher in MDA-MB-231 than in HCC70 (p < 0.01), and 4-fold higher than that of the irrelevant control (p < 0.01). Moreover, 99mTc-cAbVCAM1-5 uptake in MDA-MB-231 lung metastases was also higher than that of 99mTc-Ctl (p < 0.05). 99mTc-cAbVCAM1-5 is therefore a suitable tool to evaluate the role of VCAM-1 as a marker of tumor aggressiveness of TNBC.

19.
Clin Nucl Med ; 43(12): e471-e472, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30300202

RESUMO

We report herein the case of an 80-year-old man who was referred for a biochemical recurrence of a high-risk prostate cancer. In addition to prostate cancer recurrence, F-choline allowed partial initial staging of an incidental diffuse large B-cell lymphoma which was further confirmed and staged using F-FDG and a biopsy. Two types of metabolic behavior were therefore identified using F-choline and F-FDG which corresponded to 2 different uptake patterns, that is, those of the prostate and lymphoma tumoral cell contingents.


Assuntos
Linfoma Difuso de Grandes Células B/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso de 80 Anos ou mais , Colina/análogos & derivados , Fluordesoxiglucose F18 , Humanos , Masculino , Compostos Radiofarmacêuticos
20.
Nucl Med Commun ; 38(7): 563-576, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28570287

RESUMO

Fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (CT) is now a standard of care in initial staging and treatment evaluation of lymphomas. It is also used in the interim evaluation in diffuse large B cell lymphoma and Hodgkin lymphoma. However, several pitfalls may occur during or after treatment, because of the nonspecificity of F-FDG for lymphoma disease and treatment as immunotherapy, thus possibly induces misinterpretation and wrong treatment decision. The aim of this pictorial review is to provide an illustrated tutorial of the most frequent pitfalls found on F-FDG-PET/CT during or after treatment.


Assuntos
Fluordesoxiglucose F18 , Linfoma/diagnóstico por imagem , Linfoma/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA