Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 1): 258-266, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36601945

RESUMO

As part of its Extremely Brilliant Source (EBS) upgrade project, the ESRF's BM29 BioSAXS beamline was subject to a significant upgrade and refurbishment. In addition to the replacement of the beamline's original bending magnet source by a two-pole wiggler, leading to an increase in brilliance by a factor of 60, the sample environment of the beamline was almost completely refurbished: a vacuum-compatible Pilatus3 X 2M with a sensitive area of 253.7 mm × 288 mm and frame rates up to 250 Hz was installed, increasing the active area available and thus the q-scaling of scattering images taken; the sample changer was replaced with an upgraded version, allowing more space for customizable sample environments and the installation of two new sample exposure units; the software associated with the beamline was also renewed. In addition, the layout and functionality of the BSXCuBE3 (BioSAXS Customized Beamline Environment) data acquisition software was redesigned, providing an intuitive `user first' approach for inexperienced users, while at the same time maintaining more powerful options for experienced users and beamline staff. Additional features of BSXCuBE3 are queuing of samples; either consecutive sample changer and/or SEC-SAXS (size-exclusion chromatography small-angle X-ray scattering) experiments, including column equilibration were also implemented. Automatic data processing and analysis are now managed via Dahu, an online server with upstream data reduction, data scaling and azimuthal integration built around PyFAI (Python Fast Azimuthal Integration), and data analysis performed using the open source FreeSAS. The results of this automated data analysis pipeline are displayed in ISPyB/ExiSAXS. The upgraded BM29 has been in operation since the post-EBS restart in September 2020, and here a full description of its new hardware and software characteristics together with examples of data obtained are provided.


Assuntos
Robótica , Síncrotrons , Humanos , Difração de Raios X , Espalhamento a Baixo Ângulo , Software , Coleta de Dados
3.
J Synchrotron Radiat ; 29(Pt 2): 581-590, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35254323

RESUMO

ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s-1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.


Assuntos
Lentes , Síncrotrons , Cristalografia por Raios X , Coleta de Dados , Substâncias Macromoleculares/química
4.
Angew Chem Int Ed Engl ; 60(9): 4689-4697, 2021 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-33320993

RESUMO

Fatty acid ß-oxidation (FAO) and oxidative phosphorylation (OXPHOS) are mitochondrial redox processes that generate ATP. The biogenesis of the respiratory Complex I, a 1 MDa multiprotein complex that is responsible for initiating OXPHOS, is mediated by assembly factors including the mitochondrial complex I assembly (MCIA) complex. However, the organisation and the role of the MCIA complex are still unclear. Here we show that ECSIT functions as the bridging node of the MCIA core complex. Furthermore, cryo-electron microscopy together with biochemical and biophysical experiments reveal that the C-terminal domain of ECSIT directly binds to the vestigial dehydrogenase domain of the FAO enzyme ACAD9 and induces its deflavination, switching ACAD9 from its role in FAO to an MCIA factor. These findings provide the structural basis for the MCIA complex architecture and suggest a unique molecular mechanism for coordinating the regulation of the FAO and OXPHOS pathways to ensure an efficient energy production.


Assuntos
Complexo I de Transporte de Elétrons/química , Flavina-Adenina Dinucleotídeo/metabolismo , Mitocôndrias/metabolismo , Acil-CoA Desidrogenases/genética , Acil-CoA Desidrogenases/metabolismo , Proteínas Adaptadoras de Transdução de Sinal/química , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Microscopia Crioeletrônica , Complexo I de Transporte de Elétrons/metabolismo , Metabolismo Energético , Flavina-Adenina Dinucleotídeo/química , Humanos , Fosforilação Oxidativa , Domínios e Motivos de Interação entre Proteínas , Estrutura Terciária de Proteína , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/química , Proteínas Recombinantes/isolamento & purificação
5.
J Synchrotron Radiat ; 27(Pt 3): 844-851, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32381789

RESUMO

ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s-1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.

6.
J Synchrotron Radiat ; 26(Pt 2): 393-405, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30855248

RESUMO

MXCuBE2 is the second-generation evolution of the MXCuBE beamline control software, initially developed and used at ESRF - the European Synchrotron. MXCuBE2 extends, in an intuitive graphical user interface (GUI), the functionalities and data collection methods available to users while keeping all previously available features and allowing for the straightforward incorporation of ongoing and future developments. MXCuBE2 introduces an extended abstraction layer that allows easy interfacing of any kind of macromolecular crystallography (MX) hardware component, whether this is a diffractometer, sample changer, detector or optical element. MXCuBE2 also works in strong synergy with the ISPyB Laboratory Information Management System, accessing the list of samples available for a particular experimental session and associating, either from instructions contained in ISPyB or from user input via the MXCuBE2 GUI, different data collection types to them. The development of MXCuBE2 forms the core of a fruitful collaboration which brings together several European synchrotrons and a software development factory and, as such, defines a new paradigm for the development of beamline control platforms for the European MX user community.

7.
J Synchrotron Radiat ; 25(Pt 4): 1249-1260, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979188

RESUMO

ID30B is an undulator-based high-intensity, energy-tuneable (6.0-20 keV) and variable-focus (20-200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

8.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 11): 2328-43, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26527148

RESUMO

Here, an automated procedure is described to identify the positions of many cryocooled crystals mounted on the same sample holder, to rapidly predict and rank their relative diffraction strengths and to collect partial X-ray diffraction data sets from as many of the crystals as desired. Subsequent hierarchical cluster analysis then allows the best combination of partial data sets, optimizing the quality of the final data set obtained. The results of applying the method developed to various systems and scenarios including the compilation of a complete data set from tiny crystals of the membrane protein bacteriorhodopsin and the collection of data sets for successful structure determination using the single-wavelength anomalous dispersion technique are also presented.


Assuntos
Cristalografia por Raios X/métodos , Proteínas/química , Animais , Bacillus/química , Bacteriorodopsinas/química , Bombyx/química , Análise por Conglomerados , Cristalização/métodos , Halobacterium salinarum/química , Proteínas de Insetos/química , Modelos Moleculares , Muramidase/química , Proteínas de Plantas/química , Plantas/química , Síncrotrons , Termolisina/química , Fluxo de Trabalho
9.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 1): 15-26, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25615856

RESUMO

The analysis of structural data obtained by X-ray crystallography benefits from information obtained from complementary techniques, especially as applied to the crystals themselves. As a consequence, optical spectroscopies in structural biology have become instrumental in assessing the relevance and context of many crystallographic results. Since the year 2000, it has been possible to record such data adjacent to, or directly on, the Structural Biology Group beamlines of the ESRF. A core laboratory featuring various spectrometers, named the Cryobench, is now in its third version and houses portable devices that can be directly mounted on beamlines. This paper reports the current status of the Cryobench, which is now located on the MAD beamline ID29 and is thus called the ID29S-Cryobench (where S stands for `spectroscopy'). It also reviews the diverse experiments that can be performed at the Cryobench, highlighting the various scientific questions that can be addressed.


Assuntos
Substâncias Macromoleculares/química , Espectrofotometria Ultravioleta/métodos , Análise Espectral Raman/métodos , Cor , DNA/química , Proteínas/química
10.
J Synchrotron Radiat ; 22(6): 1540-7, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524320

RESUMO

MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 Å (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.


Assuntos
Cristalização/instrumentação , Cristalografia por Raios X/instrumentação , Armazenamento e Recuperação da Informação/métodos , Complexos Multiproteicos/química , Complexos Multiproteicos/ultraestrutura , Síncrotrons/instrumentação , Algoritmos , Biopolímeros/química , Desenho de Equipamento , Análise de Falha de Equipamento , Robótica/instrumentação
11.
J Appl Crystallogr ; 57(Pt 2): 602-605, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38596739

RESUMO

In addressing the challenges faced by laboratories and universities with limited (or no) cryo-electron microscopy (cryo-EM) infrastructure, the ESRF, in collaboration with the Grenoble Institute for Structural Biology (IBS), has implemented the cryo-EM Solution-to-Structure (SOS) pipeline. This inclusive process, spanning grid preparation to high-resolution data collection, covers single-particle analysis and cryo-electron tomography (cryo-ET). Accessible through a rolling access route, proposals undergo scientific merit and technical feasibility evaluations. Stringent feasibility criteria demand robust evidence of sample homogeneity. Two distinct entry points are offered: users can either submit purified protein samples for comprehensive processing or initiate the pipeline with already vitrified cryo-EM grids. The SOS pipeline integrates negative stain imaging (exclusive to protein samples) as a first quality step, followed by cryo-EM grid preparation, grid screening and preliminary data collection for single-particle analysis, or only the first two steps for cryo-ET. In both cases, if the screening steps are successfully completed, high-resolution data collection will be carried out using a Titan Krios microscope equipped with a latest-generation direct electron counting detector coupled to an energy filter. The SOS pipeline thus emerges as a comprehensive and efficient solution, further democratizing access to cryo-EM research.

12.
Acta Crystallogr D Struct Biol ; 80(Pt 1): 16-25, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38088897

RESUMO

The technique of time-resolved macromolecular crystallography (TR-MX) has recently been rejuvenated at synchrotrons, resulting in the design of dedicated beamlines. Using pump-probe schemes, this should make the mechanistic study of photoactive proteins and other suitable systems possible with time resolutions down to microseconds. In order to identify relevant time delays, time-resolved spectroscopic experiments directly performed on protein crystals are often desirable. To this end, an instrument has been built at the icOS Lab (in crystallo Optical Spectroscopy Laboratory) at the European Synchrotron Radiation Facility using reflective focusing objectives with a tuneable nanosecond laser as a pump and a microsecond xenon flash lamp as a probe, called the TR-icOS (time-resolved icOS) setup. Using this instrument, pump-probe spectra can rapidly be recorded from single crystals with time delays ranging from a few microseconds to seconds and beyond. This can be repeated at various laser pulse energies to track the potential presence of artefacts arising from two-photon absorption, which amounts to a power titration of a photoreaction. This approach has been applied to monitor the rise and decay of the M state in the photocycle of crystallized bacteriorhodopsin and showed that the photocycle is increasingly altered with laser pulses of peak fluence greater than 100 mJ cm-2, providing experimental laser and delay parameters for a successful TR-MX experiment.


Assuntos
Proteínas , Síncrotrons , Análise Espectral , Proteínas/química , Cristalografia , Luz
13.
Acta Crystallogr D Biol Crystallogr ; 69(Pt 7): 1289-96, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23793155

RESUMO

The ESRF has worked with, and provided services for, the pharmaceutical industry since the construction of its first protein crystallography beamline in the mid-1990s. In more recent times, industrial clients have benefited from a portfolio of beamlines which offer a wide range of functionality and beam characteristics, including tunability, microfocus and micro-aperture. Included in this portfolio is a small-angle X-ray scattering beamline dedicated to the study of biological molecules in solution. The high demands on throughput and efficiency made by the ESRF's industrial clients have been a major driving force in the evolution of the ESRF's macromolecular crystallography resources, which now include remote access, the automation of crystal screening and data collection, and a beamline database allowing sample tracking, experiment reporting and real-time at-a-distance monitoring of experiments. This paper describes the key features of the functionality put in place on the ESRF structural biology beamlines and outlines the major advantages of the interaction of the ESRF with the pharmaceutical industry.


Assuntos
Cristalografia por Raios X , Coleta de Dados , Processamento Eletrônico de Dados , Indústrias , Substâncias Macromoleculares/química , Síncrotrons/instrumentação , Bases de Dados Factuais , Europa (Continente)
14.
Sci Rep ; 13(1): 8694, 2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-37248285

RESUMO

Multi-specific antibodies (msAbs) are being developed as next generation antibody-based therapeutics. Knowledge of the three-dimensional structures, in the full antibody context, of their fragment antigen-binding (Fab) moieties with or without bound antigens is key to elucidating their therapeutic efficiency and stability. However, the flexibility of msAbs, a feature essential for their multi specificity, has hindered efforts in this direction. Cross-Over Dual Variable immunoglobulin (CODVIg) is a promising bispecific antibody format, designed to simultaneously target the interleukins IL4 and IL13. In this work we present the biophysical and structural characterisation of a CODVFab:IL13 complex in the full antibody context, using cryo-electron microscopy at an overall resolution of 4.2 Å. Unlike the 1:2 stoichiometry previously observed for CODVIg:IL4, CODVIg:IL13 shows a 1:1 stoichiometry. As well as providing details of the IL13-CODV binding interface, including the residues involved in the epitope-paratope region, the structure of CODVFab:IL13 also validates the use of labelling antibody as a new strategy for the single particle cryo-EM study of msAbs in complex with one, or more, antigens. This strategy reduced the inherent flexibility of the IL13 binding domain of CODV without inducing either structural changes at the epitope level or steric hindrance between the IL4 and IL13 binding regions of CODVIg. The work presented here thus also contributes to the development of methodology for the structural study of msAbs, a promising platform for cancer immunotherapy.


Assuntos
Anticorpos Monoclonais , Interleucina-13 , Microscopia Crioeletrônica , Interleucina-4 , Antígenos , Epitopos/química
15.
Mol Microbiol ; 81(2): 354-67, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21692874

RESUMO

Activation of LysR-type transcription factors (LTTRs) is thought to result from conformational changes that occur when inducer molecules bind to their Inducer Binding Domains (IBDs). However, the exact nature of these changes remains to be fully elucidated. We present the crystal structures of two truncated constructs of the LTTR DntR in their apo- forms and in complex with its natural inducer molecule, salicylate. These provide a fuller picture of the conformational changes that can occur in LTTR IBDs and offer insights that may be relevant when considering the mechanism of activation of LTTRs. Two of the crystal structures show that DntR IBDs can bind up to two inducer molecules. The full extent of conformational changes observed is achieved only when inducer molecules are bound in both binding sites identified. Point mutations disrupting the putative secondary binding site produce DntR variants with a reduced response to salicylate in a whole cell system, suggesting that this site is functionally relevant.


Assuntos
Burkholderia/química , Salicilatos/química , Fatores de Transcrição/química , Regulação Alostérica , Sítios de Ligação , Cristalografia por Raios X , Modelos Moleculares , Proteínas Mutantes/genética , Proteínas Mutantes/metabolismo , Mutação Puntual , Ligação Proteica , Conformação Proteica , Estrutura Terciária de Proteína , Salicilatos/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
16.
Mol Microbiol ; 79(5): 1260-75, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21208302

RESUMO

Fur, the ferric uptake regulator, is a transcription factor that controls iron metabolism in bacteria. Binding of ferrous iron to Fur triggers a conformational change that activates the protein for binding to specific DNA sequences named Fur boxes. In Helicobacter pylori, HpFur is involved in acid response and is important for gastric colonization in model animals. Here we present the crystal structure of a functionally active HpFur mutant (HpFur2M; C78S-C150S) bound to zinc. Although its fold is similar to that of other Fur and Fur-like proteins, the crystal structure of HpFur reveals a unique structured N-terminal extension and an unusual C-terminal helix. The structure also shows three metal binding sites: S1 the structural ZnS4 site previously characterized biochemically in HpFur and the two zinc sites identified in other Fur proteins. Site-directed mutagenesis and spectroscopy analyses of purified wild-type HpFur and various mutants show that the two metal binding sites common to other Fur proteins can be also metallated by cobalt. DNA protection and circular dichroism experiments demonstrate that, while these two sites influence the affinity of HpFur for DNA, only one is absolutely required for DNA binding and could be responsible for the conformational changes of Fur upon metal binding while the other is a secondary site.


Assuntos
Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Helicobacter pylori/metabolismo , Ferro/metabolismo , Proteínas Repressoras/química , Proteínas Repressoras/metabolismo , Sequência de Aminoácidos , Proteínas de Bactérias/genética , Sítios de Ligação , DNA Bacteriano/metabolismo , Helicobacter pylori/química , Helicobacter pylori/genética , Dados de Sequência Molecular , Estrutura Secundária de Proteína , Proteínas Repressoras/genética , Alinhamento de Sequência
17.
J Synchrotron Radiat ; 19(Pt 3): 455-61, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514185

RESUMO

ID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.62 Što 2.07 Å) dedicated to the use of anomalous dispersion techniques in macromolecular crystallography. Since the beamline was first commissioned in 2001, ID29 has, in order to provide an improved service to both its academic and proprietary users, been the subject of almost continuous upgrade and refurbishment. It is now also the home to the ESRF Cryobench facility, ID29S. Here, the current status of the beamline is described and plans for its future are briefly outlined.


Assuntos
Substâncias Macromoleculares/química , Síncrotrons/instrumentação , Tripsina/química , Difração de Raios X
18.
Bioinformatics ; 27(22): 3186-92, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21949273

RESUMO

MOTIVATION: Individual research groups now analyze thousands of samples per year at synchrotron macromolecular crystallography (MX) resources. The efficient management of experimental data is thus essential if the best possible experiments are to be performed and the best possible data used in downstream processes in structure determination pipelines. Information System for Protein crystallography Beamlines (ISPyB), a Laboratory Information Management System (LIMS) with an underlying data model allowing for the integration of analyses down-stream of the data collection experiment was developed to facilitate such data management. RESULTS: ISPyB is now a multisite, generic LIMS for synchrotron-based MX experiments. Its initial functionality has been enhanced to include improved sample tracking and reporting of experimental protocols, the direct ranking of the diffraction characteristics of individual samples and the archiving of raw data and results from ancillary experiments and post-experiment data processing protocols. This latter feature paves the way for ISPyB to play a central role in future macromolecular structure solution pipelines and validates the application of the approach used in ISPyB to other experimental techniques, such as biological solution Small Angle X-ray Scattering and spectroscopy, which have similar sample tracking and data handling requirements.


Assuntos
Cristalografia por Raios X/métodos , Sistemas de Informação Administrativa , Proteínas/química , Síncrotrons , Cristalografia por Raios X/instrumentação , Coleta de Dados , Substâncias Macromoleculares/química , Difração de Raios X
19.
IUCrJ ; 9(Pt 6): 756-767, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36381146

RESUMO

The development of serial crystallography over the last decade at XFELs and synchrotrons has produced a renaissance in room-temperature macromolecular crystallography (RT-MX), and fostered many technical and methodological breakthroughs designed to study phenomena occurring in proteins on the picosecond-to-second timescale. However, there are components of protein dynamics that occur in much slower regimes, of which the study could readily benefit from state-of-the-art RT-MX. Here, the room-temperature structural study of the relaxation of a reaction intermediate at a synchrotron, exploiting a handful of single crystals, is described. The intermediate in question is formed in microseconds during the photoreaction of the LOV2 domain of phototropin 2 from Arabidopsis thaliana, which then decays in minutes. This work monitored its relaxation in the dark using a fast-readout EIGER X 4M detector to record several complete oscillation X-ray diffraction datasets, each of 1.2 s total exposure time, at different time points in the relaxation process. Coupled with in crystallo UV-Vis absorption spectroscopy, this RT-MX approach allowed the authors to follow the relaxation of the photoadduct, a thio-ether covalent bond between the chromophore and a cysteine residue. Unexpectedly, the return of the chromophore to its spectroscopic ground state is followed by medium-scale protein rearrangements that trigger a crystal phase transition and hinder the full recovery of the structural ground state of the protein. In addition to suggesting a hitherto unexpected role of a conserved tryptophan residue in the regulation of the photocycle of LOV2, this work provides a basis for performing routine time-resolved protein crystallography experiments at synchrotrons for phenomena occurring on the second-to-hour timescale.

20.
Commun Biol ; 5(1): 360, 2022 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-35422073

RESUMO

In this work we examine how small hydrophobic molecules such as inert gases interact with membrane proteins (MPs) at a molecular level. High pressure atmospheres of argon and krypton were used to produce noble gas derivatives of crystals of three well studied MPs (two different proton pumps and a sodium light-driven ion pump). The structures obtained using X-ray crystallography showed that the vast majority of argon and krypton binding sites were located on the outer hydrophobic surface of the MPs - a surface usually accommodating hydrophobic chains of annular lipids (which are known structural and functional determinants for MPs). In conformity with these results, supplementary in silico molecular dynamics (MD) analysis predicted even greater numbers of argon and krypton binding positions on MP surface within the bilayer. These results indicate a potential importance of such interactions, particularly as related to the phenomenon of noble gas-induced anaesthesia.


Assuntos
Anestésicos , Criptônio , Argônio/química , Argônio/farmacologia , Cristalografia por Raios X , Criptônio/química , Criptônio/metabolismo , Lipídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA