Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Nano Lett ; 15(12): 7905-12, 2015 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-26524388

RESUMO

The vertical transport of nonequilibrium charge carriers through semiconductor heterostructures has led to milestones in electronics with the development of the hot-electron transistor. Recently, significant advances have been made with atomically sharp heterostructures implementing various two-dimensional materials. Although graphene-base hot-electron transistors show great promise for electronic switching at high frequencies, they are limited by their low current gain. Here we show that, by choosing MoS2 and HfO2 for the filter barrier interface and using a noncrystalline semiconductor such as ITO for the collector, we can achieve an unprecedentedly high-current gain (α ∼ 0.95) in our hot-electron transistors operating at room temperature. Furthermore, the current gain can be tuned over 2 orders of magnitude with the collector-base voltage albeit this feature currently presents a drawback in the transistor performance metrics such as poor output resistance and poor intrinsic voltage gain. We anticipate our transistors will pave the way toward the realization of novel flexible 2D material-based high-density, low-energy, and high-frequency hot-carrier electronic applications.

2.
Nano Lett ; 14(5): 2709-14, 2014 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-24742304

RESUMO

We have developed a novel, all-electronic biosensor for opioids that consists of an engineered µ-opioid receptor protein, with high binding affinity for opioids, chemically bonded to a graphene field-effect transistor to read out ligand binding. A variant of the receptor protein that provided chemical recognition was computationally redesigned to enhance its solubility and stability in an aqueous environment. A shadow mask process was developed to fabricate arrays of hundreds of graphene transistors with average mobility of ∼1500 cm(2) V(-1) s(-1) and yield exceeding 98%. The biosensor exhibits high sensitivity and selectivity for the target naltrexone, an opioid receptor antagonist, with a detection limit of 10 pg/mL.


Assuntos
Técnicas Biossensoriais/métodos , Grafite/química , Naltrexona/isolamento & purificação , Receptores Opioides mu/antagonistas & inibidores , Humanos , Naltrexona/química , Receptores Opioides mu/química , Água/química
3.
J Am Chem Soc ; 134(35): 14318-21, 2012 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-22894721

RESUMO

Despite the great promise of carbon nanotube field-effect transistors (CNT FETs) for applications in chemical and biochemical detection, a quantitative understanding of sensor responses is lacking. To explore the role of electrostatics in sensor transduction, experiments were conducted with a set of highly similar compounds designed to adsorb onto the CNT FET via a pyrene linker group and take on a set of known charge states under ambient conditions. Acidic and basic species were observed to induce threshold voltage shifts of opposite sign, consistent with gating of the CNT FET by local charges due to protonation or deprotonation of the pyrene compounds by interfacial water. The magnitude of the gate voltage shift was controlled by the distance between the charged group and the CNT. Additionally, functionalization with an uncharged pyrene compound showed a threshold shift ascribed to its molecular dipole moment. This work illustrates a method for producing CNT FETs with controlled values of the turnoff gate voltage, and more generally, these results will inform the development of quantitative models for the response of CNT FET chemical and biochemical sensors.

4.
Biosens Bioelectron ; 100: 85-88, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28865242

RESUMO

We have developed a cost-effective and portable graphene-enabled biosensor to detect Zika virus with a highly specific immobilized monoclonal antibody. Field Effect Biosensing (FEB) with monoclonal antibodies covalently linked to graphene enables real-time, quantitative detection of native Zika viral (ZIKV) antigens. The percent change in capacitance in response to doses of antigen (ZIKV NS1) coincides with levels of clinical significance with detection of antigen in buffer at concentrations as low as 450pM. Potential diagnostic applications were demonstrated by measuring Zika antigen in a simulated human serum. Selectivity was validated using Japanese Encephalitis NS1, a homologous and potentially cross-reactive viral antigen. Further, the graphene platform can simultaneously provide the advanced quantitative data of nonclinical biophysical kinetics tools, making it adaptable to both clinical research and possible diagnostic applications. The speed, sensitivity, and selectivity of this first-of-its-kind graphene-enabled Zika biosensor make it an ideal candidate for development as a medical diagnostic test.


Assuntos
Anticorpos Imobilizados/química , Antígenos Virais/análise , Técnicas Biossensoriais/métodos , Grafite/química , Infecção por Zika virus/diagnóstico , Zika virus/isolamento & purificação , Antígenos Virais/sangue , Técnicas Biossensoriais/instrumentação , Desenho de Equipamento , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Sensibilidade e Especificidade , Infecção por Zika virus/sangue , Infecção por Zika virus/virologia
5.
Sci Rep ; 6: 32503, 2016 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-27581550

RESUMO

Vertical hot electron transistors incorporating atomically-thin 2D materials, such as graphene or MoS2, in the base region have been proposed and demonstrated in the development of electronic and optoelectronic applications. To the best of our knowledge, all previous 2D material-base hot electron transistors only considered applying a positive collector-base potential (VCB > 0) as is necessary for the typical unipolar hot-electron transistor behavior. Here we demonstrate a novel functionality, specifically a dual-mode operation, in our 2D material-base hot electron transistors (e.g. with either graphene or MoS2 in the base region) with the application of a negative collector-base potential (VCB < 0). That is, our 2D material-base hot electron transistors can operate in either a hot-electron or a reverse-current dominating mode depending upon the particular polarity of VCB. Furthermore, these devices operate at room temperature and their current gains can be dynamically tuned by varying VCB. We anticipate our multi-functional dual-mode transistors will pave the way towards the realization of novel flexible 2D material-based high-density and low-energy hot-carrier electronic applications.

6.
ACS Nano ; 7(3): 2800-7, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23442175

RESUMO

Vapor sensors based on functionalized carbon nanotubes (NTs) have shown great promise, with high sensitivity conferred by the reduced dimensionality and exceptional electronic properties of the NT. Critical challenges in the development of NT-based sensor arrays for chemical detection include the demonstration of reproducible fabrication methods and functionalization schemes that provide high chemical diversity to the resulting sensors. Here, we outline a scalable approach to fabricating arrays of vapor sensors consisting of NT field effect transistors functionalized with single-stranded DNA (DNA-NT). DNA-NT sensors were highly reproducible, with responses that could be described through equilibrium thermodynamics. Target analytes were detected even in large backgrounds of volatile interferents. DNA-NT sensors were able to discriminate between highly similar molecules, including structural isomers and enantiomers. The sensors were also able to detect subtle variations in complex vapors, including mixtures of structural isomers and mixtures of many volatile organic compounds characteristic of humans.


Assuntos
Técnicas Biossensoriais , DNA de Cadeia Simples , Nanotubos de Carbono/química , Compostos Orgânicos Voláteis/análise , Cicloexenos/análise , Cicloexenos/química , DNA de Cadeia Simples/química , Hemiterpenos , Humanos , Limoneno , Nanotecnologia , Ácidos Pentanoicos/análise , Eletricidade Estática , Estereoisomerismo , Terpenos/análise , Terpenos/química , Termodinâmica , Compostos Orgânicos Voláteis/química
7.
Biosens Bioelectron ; 45: 163-7, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23475141

RESUMO

We examined the potential of antibody-functionalized single-walled carbon nanotube (SWNT) field-effect transistors (FETs) to use as a fast and accurate sensor for a Lyme disease antigen. Biosensors were fabricated on oxidized silicon wafers using chemical vapor deposition grown carbon nanotubes that were functionalized using diazonium salts. Attachment of Borrelia burgdorferi (Lyme) flagellar antibodies to the nanotubes was verified by atomic force microscopy and electronic measurements. A reproducible shift in the turn-off voltage of the semiconducting SWNT FETs was seen upon incubation with B. burgdorferi flagellar antigen, indicative of the nanotube FET being locally gated by the residues of flagellar protein bound to the antibody. This sensor effectively detected antigen in buffer at concentrations as low as 1 ng/ml, and the response varied strongly over a concentration range coinciding with levels of clinical interest. Generalizable binding chemistry gives this biosensing platform the potential to be expanded to monitor other relevant antigens, enabling a multiple vector sensor for Lyme disease. The speed and sensitivity of this biosensor make it an ideal candidate for development as a medical diagnostic test.


Assuntos
Antígenos/isolamento & purificação , Técnicas Biossensoriais , Borrelia burgdorferi/isolamento & purificação , Doença de Lyme/diagnóstico , Anticorpos/química , Antígenos/imunologia , Borrelia burgdorferi/imunologia , Humanos , Doença de Lyme/imunologia , Doença de Lyme/virologia , Microscopia de Força Atômica , Nanotubos de Carbono/química
8.
ACS Nano ; 7(11): 10129-38, 2013 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-24182310

RESUMO

Graphene-boron nitride monolayer heterostructures contain adjacent electrically active and insulating regions in a continuous, single-atom thick layer. To date structures were grown at low pressure, resulting in irregular shapes and edge direction, so studies of the graphene-boron nitride interface were restricted to the microscopy of nanodomains. Here we report templated growth of single crystalline hexagonal boron nitride directly from the oriented edge of hexagonal graphene flakes by atmospheric pressure chemical vapor deposition, and physical property measurements that inform the design of in-plane hybrid electronics. Ribbons of boron nitride monolayer were grown from the edge of a graphene template and inherited its crystallographic orientation. The relative sharpness of the interface was tuned through control of growth conditions. Frequent tearing at the graphene-boron nitride interface was observed, so density functional theory was used to determine that the nitrogen-terminated interface was prone to instability during cool down. The electronic functionality of monolayer heterostructures was demonstrated through fabrication of field effect transistors with boron nitride as an in-plane gate dielectric.

9.
ACS Nano ; 6(6): 5143-9, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22575126

RESUMO

We developed a novel detection method for osteopontin (OPN), a new biomarker for prostate cancer, by attaching a genetically engineered single-chain variable fragment (scFv) protein with high binding affinity for OPN to a carbon nanotube field-effect transistor (NT-FET). Chemical functionalization using diazonium salts is used to covalently attach scFv to NT-FETs, as confirmed by atomic force microscopy, while preserving the activity of the biological binding site for OPN. Electron transport measurements indicate that functionalized NT-FET may be used to detect the binding of OPN to the complementary scFv protein. A concentration-dependent increase in the source-drain current is observed in the regime of clinical significance, with a detection limit of approximately 30 fM. The scFv-NT hybrid devices exhibit selectivity for OPN over other control proteins. These devices respond to the presence of OPN in a background of concentrated bovine serum albumin, without loss of signal. On the basis of these observations, the detection mechanism is attributed to changes in scattering at scFv protein-occupied defect sites on the carbon nanotube sidewall. The functionalization procedure described here is expected to be generalizable to any antibody containing an accessible amine group and to result in biosensors appropriate for detection of corresponding complementary proteins at fM concentrations.


Assuntos
Biomarcadores Tumorais/sangue , Imunoensaio/instrumentação , Nanotubos de Carbono/química , Osteopontina/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico , Transistores Eletrônicos , Animais , Anticorpos/genética , Bovinos , Condutometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Nanotubos de Carbono/ultraestrutura , Engenharia de Proteínas/métodos
10.
ACS Nano ; 5(7): 5408-16, 2011 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-21696137

RESUMO

We have designed and implemented a practical nanoelectronic interface to G-protein coupled receptors (GPCRs), a large family of membrane proteins whose roles in the detection of molecules outside eukaryotic cells make them important pharmaceutical targets. Specifically, we have coupled olfactory receptor proteins (ORs) with carbon nanotube transistors. The resulting devices transduce signals associated with odorant binding to ORs in the gas phase under ambient conditions and show responses that are in excellent agreement with results from established assays for OR-ligand binding. The work represents significant progress on a path toward a bioelectronic nose that can be directly compared to biological olfactory systems as well as a general method for the study of GPCR function in multiple domains using electronic readout.


Assuntos
Biomimética/instrumentação , Técnicas Biossensoriais/instrumentação , Equipamentos e Provisões Elétricas , Nanotecnologia/instrumentação , Receptores Odorantes/metabolismo , Animais , Células HEK293 , Humanos , Camundongos , Nanotubos de Carbono/química , Transistores Eletrônicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA