Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Mutat Res ; 688(1-2): 53-61, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20227425

RESUMO

Humans are exposed to chromium and cobalt in industry, from the environment and after joint replacement surgery from the CoCr alloy in the implant. In this study we have investigated whether Cr(III), Cr(VI), Co(II) and Cr in combination with Co could induce chromosome aberrations in human fibroblasts in vitro at the same concentrations that have been found in the peripheral blood of exposed humans. We used 24 colour M-FISH as a sensitive way to detect translocations and aneuploidy and examined the effects of a 24-h exposure and its consequences up to 30 days after the exposure in order to record genomic instability and/or repair. At these physiological doses the metals induced predominantly numerical rather than structural aberrations. Co was the least reactive and Cr(VI) especially in combination with Co the most. All metals at the highest physiological doses caused simple (gain or loss of 3 or less chromosomes) and complex (more than 49 chromosomes) aneuploidy. All metals at the lowest physiological dose caused a significant increase of total aberrations. Cr(VI) was much more effective than Cr(III) in causing chromosome fragments, which were only induced at the highest doses. There was a slow resolution of aneuploidy with time after exposure. This involved a reduction in the proportion of aneuploid cells and a reduction of the number of chromosomes within cells showing complex aneuploidy. We conclude that these metal ions can cause chromosome aberrations at physiological concentrations and that their main effect is aneugenic.


Assuntos
Aneugênicos/toxicidade , Cromo/toxicidade , Cobalto/toxicidade , Instabilidade Genômica , Células Cultivadas , Aberrações Cromossômicas , Dano ao DNA , Reparo do DNA , Fibroblastos , Humanos
2.
Clin Orthop Relat Res ; 467(9): 2259-65, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19363640

RESUMO

High wear rates and high patient ion levels have been associated with high (> 55 degrees) cup inclination angles for metal-on-metal surface replacements. Wear rates and patterns have been simulated for ceramic-on-ceramic bearings by applying microseparation to replicate head offset deficiency. We tested 39-mm metal-on-metal surface replacements (n = 5) in a hip simulator with (A) an increased cup inclination angle of 60 degrees and (B) an increased cup inclination angle and microseparation over 2 million cycles. (A) resulted in a ninefold increase in wear rate and (B) resulted in a 17-fold increase in wear rate compared to a standard gait condition study. Wear particles produced under microseparation conditions were larger than those produced under standard conditions but of similar shape (round to oval). The data suggest both head and cup position influence the wear of surface replacements; we believe it likely bearings with high wear either have a high cup inclination angle, an offset deficient head, or a combination of both.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Artroplastia de Quadril/métodos , Humanos , Teste de Materiais , Tamanho da Partícula , Suporte de Carga
3.
J Biomed Mater Res B Appl Biomater ; 95(2): 263-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20860044

RESUMO

Ceramic-on-ceramic (CoC) bearings in total hip replacements (THRs) have shown low wear volumes under standard gait in hip simulator studies. However, clinical reports have indicated variations in wear rates and formation of stripe-like wear area on the ceramic femoral heads. The aim of this study was to investigate the influence of cup inclination angle and microseparation on the wear of CoC bearings in THRs. The six station Leeds II Physiological Anatomical Joint Simulator was used to investigate the wear of 28 mm diameter alumina matrix composite ceramic bearings (BIOLOX® delta). It was shown that increasing the cup inclination angle from 55° to 65° had no significant effect on the wear rate of BIOLOX® delta CoC under both standard gait and microseparation conditions in this in vitro study. Under standard gait conditions, the mean wear rate for both cup inclination angle conditions was very low at 0.05 mm(3)/million cycles. The introduction of microseparation to the standard gait cycle increased the mean wear rates to 0.13 mm(3)/million cycles for the cup inclination angle of 55° and 0.11 mm(3)/million cycles for that of 65°. The level of increased wear with microseparation was not dependent on cup angle. A stripe of wear on the head also formed, with corresponding superior rim wear on the cup. The wear rates obtained were low compared to the HIPed third generation alumina ceramic (BIOLOX® forte) tested under the same adverse conditions (1.84 mm(3)/million cycles). BIOLOX® delta has shown lower wear than previous ceramic materials used in THR under adverse conditions.


Assuntos
Artroplastia de Quadril , Cerâmica , Teste de Materiais , Fluoroscopia , Modelos Teóricos , Propriedades de Superfície
4.
J Biomed Mater Res B Appl Biomater ; 90(2): 558-65, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19195030

RESUMO

Increased patient blood and serum levels of Co and Cr and dissemination of metal wear particles throughout organs and tissues are the primary concerns with metal-on-metal surface replacements. Surface engineering, providing a ceramic bearing surface on a metal substrate, could provide a solution. This study investigated thick (>10 microm) arc evaporation plasma vapor deposition chromium nitride (CrN) coated surface replacements in terms of wear, ion levels, and wear particles in a 10 million cycle hip simulator study, compared to a contemporary metal-on-metal surface replacement. The ion levels were measured by inductively coupled plasma mass spectroscopy. The wear particles were imaged by field emission gun scanning electron microscopy. The CrN-coated bearings had 80% lower wear than the MoM controls. The Cr and Co ion levels in the lubricant of the CrN bearings were 73 and 98% lower than in the MoM controls. The wear particles produced were in the nanometer size range and round to oval in morphology. The CrN coating could provide a reduction in the wear and ion release of MoM surface replacements, thereby reducing the perceived risks to the patient associated with these prostheses.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cerâmica/química , Cromo/química , Materiais Revestidos Biocompatíveis/química , Cobalto/química , Prótese de Quadril , Humanos , Íons , Teste de Materiais , Metais/química , Microscopia Eletrônica de Varredura/métodos , Compostos de Nitrogênio/química , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA