1.
Anal Bioanal Chem ; 2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38879845

RESUMO

A simple and reliable external calibration strategy of LA-ICP-MS for fresh plant soft tissues was developed. The prepared plant suspension was frozen by the designed cryogenic ablation cell and used as external standard for quantitative elemental imaging analysis of fresh plant tissues. The controllable water content of the prepared external standards provides a similar matrix with fresh soft tissues, and a homogeneous elemental distribution could be ensured due to the fine grinding particle sizes. More interestingly, the presence of water increased the signal intensity produced by the suspension by a factor of 1.6 (Pb) to 66.6 (La) compared to that of the pressed cake. The excellent dispersing property and advantage of long-term use were achieved owing to the employment of 0.1% PAANa as suspending agent. A series of plant reference materials were analyzed, and the relative errors of most elements were less than 10 %, indicating that there is a reliable accuracy of the proposed method. The limits of detection (LODs) ranged from 0.1 ng·g-1 (La) to 1279 ng·g-1 (S). This method was used for elemental imaging analysis in rice leaves under arsenic stress, and the results were consistent with previous studies, which mean that the proposed method could provide technical support for researchers in the fields of agriculture and environment.

2.
Anal Bioanal Chem ; 415(24): 6051-6061, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37541973

RESUMO

A novel method for direct high-throughput analysis of multi-elements in cerebrospinal fluid (CSF) samples by laser ablation inductively coupled plasma mass spectrometry with an aerosol local extraction cryogenic ablation cell (ALEC-LA-ICP-MS) was developed. Microliter-level CSF samples were frozen by a designed cryogenic ablation cell and directly analyzed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) without time-consuming pretreatment. Compared with the precision obtained at room temperature (20℃), that obtained at low temperature (- 25℃) was significantly improved; the RSDs were reduced from 8.3% (Zn) to 32.6% (Mn) to 2.2% (Pb) to 6.5% (Mn) with six times parallel determination. To meet the analytical requirement of the micro-volume CSF samples, the laminar flow aerosol local extraction strategy was adopted to improve the transmission efficiency of aerosols, and the signal intensity was increased by four times compared with the standard commercial ablation cell. The standard solution with 0.4% bovine serum albumin (BSA) matrix was used as matrix-match external standard, and Rh was added into the samples as internal standard. The limits of detection (LODs) ranged from 0.17 µg·L-1 (Mn) to 8.67 µg·L-1 (Mg). Standard addition recovery experiments and the determination of CRM serum L-1 and L-2 were carried out to validate the accuracy of the method; all results indicated there were excellent accuracy and precision in the proposed method. The matrix-scanning function in the GeoLas software combined with the microwell plate realizes the high-throughput automatic analysis. Twenty-four CSF samples from different patients were determined; the results showed that there might be a correlation between the metal elements in CSF and the diseases, which means that the proposed method has potential in the diagnosis of neurological diseases.

3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 39(1): 128-138, 2022 Feb 25.
Artigo em Zh | MEDLINE | ID: mdl-35231974

RESUMO

Cell migration is defined as the directional movement of cells toward a specific chemical concentration gradient, which plays a crucial role in embryo development, wound healing and tumor metastasis. However, current research methods showed low flux and are only suitable for single-factor assessment, and it was difficult to comprehensively consider the effects of other parameters such as different concentration gradients on cell migration behavior. In this paper, a four-channel microfluidic chip was designed. Its characteristics were as follows: it relied on laminar flow and diffusion mechanisms to establish and maintain a concentration gradient; it was suitable for observation of cell migration in different concentration gradient environment under a single microscope field; four cell isolation zones (20 µm width) were integrated into the microfluidic device to calibrate the initial cell position, which ensured the accuracy of the experimental results. In particular, we used COMSOL Multiphysics software to simulate the structure of the chip, which demonstrated the necessity of designing S-shaped microchannel and horizontal pressure balance channel to maintain concentration gradient. Finally, neutrophils were incubated with advanced glycation end products (AGEs, 0, 0.2, 0.5, 1.0 µmol·L -1), which were closely related to diabetes mellitus and its complications. The migration behavior of incubated neutrophils was studied in the 100 nmol·L -1 of chemokine (N-formylmethionyl-leucyl-phenyl-alanine) concentration gradient. The results prove the reliability and practicability of the microfluidic chip.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Movimento Celular , Quimiotaxia , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Neutrófilos , Reprodutibilidade dos Testes
4.
Anal Chem ; 89(12): 6827-6833, 2017 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-28506057

RESUMO

In the present study, a novel and sensitive liquid spray dielectric barrier discharge induced plasma-chemical vapor generation technique (LSDBD-CVG) is developed for the determination of lead concentration by inductively coupled plasma mass spectrometry (ICPMS). The dissolved Pb2+ is readily converted to volatile species by LSDBD plasma induced chemical processes in the presence of 5% (v/v) formic acid in a supporting electrolyte (HCl, 0.01 mol L-1). In this LSDBD approach, the sample solution is converted to aerosol and simultaneously mixed with the DBD plasma generated at the nozzle of a pneumatic nebulizer, which greatly facilitates Pb vapor generation because of the enhanced interaction of sprayed analytes and the plasma. Optimal conditions for LSDBD-CVG were identified, and the interference effects from other metal ions were assessed. Under optimized conditions, the detection limit of Pb was found to be 0.003 µg L-1. The repeatability, expressed as the relative standard deviation (RSD) of the peak height, for the five replicate measurements of 0.03 and 1 µg L-1 lead standard, were 2.1% and 1.7%, respectively. Compared with other vapor generation methods, this new LSDBD-CVG offers several advantages including no requirement of unstable reagents, fast response, and easy coupling with flow injection, along with high tolerance for coexisting ions. The accuracy of the proposed method is demonstrated by successful analysis of Pb in reference material of stream sediment (GBW07311), soil (GBW07403), basalt (BCR-2), and simulated water sample (GBW08601). The proposed LSDBD-CVG extends the scope of elements accessible by plasma-CVG and provides an alternative efficient green approach for the vapor generation of Pb.

7.
Huan Jing Ke Xue ; 36(11): 3972-80, 2015 Nov.
Artigo em Zh | MEDLINE | ID: mdl-26910980

RESUMO

A multi-day haze episode occurred in Shijiazhuang during November 18-26, 2014. The characteristics were studied based on the data collected by the single particle aerosol mass spectrometer (SPAMS) located in the automatic monitoring station (20 meters) of Shijiazhuang. In accordance with the source spectral library of atmospheric pollutant emissions in Shijiazhuang, the main sources were distinguished and analyzed. The mass concentration of particulate matters and meteorological conditions being taken in account, the causes of haze in winter were also studied. It turned out that fine particulate matters in the Shijiazhuang air were mainly from 7 different sources: the tracer ion of coal source was Al; the tracer ions of industry sources were OC, Fe, and Pb; the tracer ion of motor vehicle tail gas source was EC; the tracer ions of dust source were Al, Ca and Si; the tracer ions of biomass burning source were K and levoglucosan; the tracer ions of pure secondary inorganic source were SO4-, NO2-, and NO3-, and the tracer ion of dining source was HOC. Of the above mentioned, OC, HOC, EC, HEC, ECOC, rich potassium particles minerals and heavy metals were 8 dominant polluting groups in hazy days. OC and ECOC particles were the majority, which accounted for more than 50% and 20% of the overall measured particles. OC particles were mainly discharged from coal combustion and industrial processes, and ECOC particles were mainly from coal combustion and vehicle exhaust emissions. When haze occurred in Shijiazhuang the proportion of pollutant particles of NH4+, SO4- , NO2- and NO3- increased, of which NH4+ was the most sharply increased. The mixed degree between EC, OC and NH4+, So4-, NO3- in the haze was higher than usual, of which NH4+ was the most sharply increased. In the static and stable weather gaseous (SO2, NO(x), NH3, VOCs) pollutants and particles were difficult to spread and accumulated rapidly, which were discharged from coal combustion, the process of the medical industry and the automobile exhaust. The gaseous pollutants tended to react for the second time and formed the ammonium nitrate and ammonium sulfate particles. Secondary particles were formed by collision and mixed with each other adequately or mildly, which caused the reduction of atmospheric visibility. This was the main cause for the haze during the winter in Shijiazhuang.


Assuntos
Poluentes Atmosféricos/química , Poluição do Ar/análise , Aerossóis , Sulfato de Amônio/química , China , Cidades , Carvão Mineral , Poeira , Gases , Espectrometria de Massas , Nitratos/química , Tamanho da Partícula , Material Particulado/análise , Estações do Ano , Emissões de Veículos , Tempo (Meteorologia)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA