Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiol Res Pract ; 2020: 4826073, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32963824

RESUMO

BACKGROUND: Primary percutaneous coronary intervention (PCI) is the best available reperfusion strategy in patients with acute ST-segment elevation myocardial infarction (STEMI). However, PCI is associated with a serious problem known as no-reflow phenomenon, resulting in poor clinical and functional outcomes. This study aimed to compare the influences of different balloon deflation velocity on coronary flow and cardiovascular events during primary PCI in STEM as well as transient hemodynamic changes in in vitro experiments. Method and Results. 211 STEMI patients were randomly assigned to either a rapid or a slow balloon deflation group during stent deployment. The primary end point was coronary flow at the end of PCI procedure, and secondary end points included myocardial infarct size. Transient hemodynamic changes were evaluated through an in vitro experimental apparatus and a computer model. In clinical practice, the level of corrected TIMI frame count (cTFC) in slow balloon deflation after primary PCI was significantly lower than that of rapid balloon deflation, which was associated with smaller infarct size. Numerical simulations revealed that the rapid deflation led to a sharp acceleration of flow in the balloon-vessel gap and a concomitant abnormal rise in wall shear stress (WSS). CONCLUSION: This randomized study demonstrated that the slow balloon deflation during stent implantation improved coronary flow and reduced infarct size in reperfused STEMI. The change of flow in the balloon-vessel gap and WSS resulted from different balloon deflation velocity might be partly accounted for this results.

2.
Math Biosci Eng ; 17(1): 606-626, 2019 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-31731367

RESUMO

A computational hemodynamics method was employed to investigate how the morphotype and functional state of aortic valve would affect the characteristics of blood flow in aortas with pathological dilation, especially the intensity and distribution of flow turbulence. Two patient-specific aortas diagnosed to have pathological dilation of the ascending segment while differential aortic valve conditions (i.e., one with a stenotic and regurgitant RL bicuspid aortic valve (RL-BAV), whereas the other with a quasi-normal tricuspid aortic valve (TAV)) were studied. When building the computational models, in addition to in vivo data-based reconstruction of geometrical model and boundary condition setting, the large eddy simulation method was adopted to quantify potential flow turbulence in the aortas. Obtained results revealed the presence of complex flow patterns (denoted by time-varying changes in vortex structure), flow turbulence (indicated by high turbulent eddy viscosity (TEV)), and regional high wall shear stress (WSS) in the ascending segment of both aortas. Such hemodynamic characteristics were significantly augmented in the aorta with RL-BAV. For instance, the space-averaged TEV in late systole and the wall area exposed to high time-averaged WSS (judged by WSS> two times of the mean WSS in the entire aorta) in the ascending aortic segment were increased by 176% and 465%, respectively. Relatively, flow patterns in the descending aortic segment were less influenced by the aortic valve disease. These results indicate that aortic valve disease has profound impacts on flow characteristics in the ascending aorta, especially the distribution and degree of high WSS and flow turbulence.


Assuntos
Valvopatia Aórtica/diagnóstico , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico , Hemodinâmica , Idoso , Aorta , Valvopatia Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Pressão , Software , Estresse Mecânico , Tomografia Computadorizada por Raios X , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA