Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38324896

RESUMO

Objective.To mitigate the potential radiation risk, low-dose single photon emission computed tomography (SPECT) is of increasing interest. Numerous deep learning-based methods have been developed to perform low-dose imaging while maintaining image quality. However, most existing methods seldom explore the unique inner-structure inherent within sinograms. In addition, traditional supervised learning methods require large-scale labeled data, where the normal-dose data serves as annotation and is intractable to acquire in low-dose imaging. In this study, we aim to develop a novel sinogram inner-structure-aware semi-supervised framework for the task of low-dose SPECT sinogram restoration.Approach.The proposed framework retains the strengths of UNet, meanwhile introducing a sinogram-structure-based non-local neighbors graph neural network (SSN-GNN) module and a window-based K-nearest neighbors GNN (W-KNN-GNN) module to effectively exploit the inherent inner-structure within SPECT sinograms. Moreover, the proposed framework employs the mean teacher semi-supervised learning approach to leverage the information available in abundant unlabeled low-dose sinograms.Main results.The datasets exploited in this study were acquired from the (Extended Cardiac-Torso) XCAT anthropomorphic digital phantoms, which provide realistic images for imaging research of various modalities. Quantitative as well as qualitative results demonstrate that the proposed framework achieves superior performance compared to several state-of-the-art reconstruction methods. To further validate the effectiveness of the proposed framework, ablation and robustness experiments were also performed. The experimental results show that each component of the proposed framework effectively improves the model performance, and the framework exhibits superior robustness with respect to various noise levels. Besides, the proposed semi-supervised paradigm showcases the efficacy of incorporating supplementary unlabeled low-dose sinograms.Significance.The proposed framework improves the quality of low-dose SPECT reconstructed images by utilizing sinogram inner-structure and incorporating supplementary unlabeled data, which provides an important tool for dose reduction without sacrificing the image quality.


Assuntos
Coração , Tomografia Computadorizada de Emissão de Fóton Único , Radiografia , Análise por Conglomerados , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador
2.
Math Biosci Eng ; 20(6): 9728-9758, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37322909

RESUMO

In order to generate high-quality single-photon emission computed tomography (SPECT) images under low-dose acquisition mode, a sinogram denoising method was studied for suppressing random oscillation and enhancing contrast in the projection domain. A conditional generative adversarial network with cross-domain regularization (CGAN-CDR) is proposed for low-dose SPECT sinogram restoration. The generator stepwise extracts multiscale sinusoidal features from a low-dose sinogram, which are then rebuilt into a restored sinogram. Long skip connections are introduced into the generator, so that the low-level features can be better shared and reused, and the spatial and angular sinogram information can be better recovered. A patch discriminator is employed to capture detailed sinusoidal features within sinogram patches; thereby, detailed features in local receptive fields can be effectively characterized. Meanwhile, a cross-domain regularization is developed in both the projection and image domains. Projection-domain regularization directly constrains the generator via penalizing the difference between generated and label sinograms. Image-domain regularization imposes a similarity constraint on the reconstructed images, which can ameliorate the issue of ill-posedness and serves as an indirect constraint on the generator. By adversarial learning, the CGAN-CDR model can achieve high-quality sinogram restoration. Finally, the preconditioned alternating projection algorithm with total variation regularization is adopted for image reconstruction. Extensive numerical experiments show that the proposed model exhibits good performance in low-dose sinogram restoration. From visual analysis, CGAN-CDR performs well in terms of noise and artifact suppression, contrast enhancement and structure preservation, particularly in low-contrast regions. From quantitative analysis, CGAN-CDR has obtained superior results in both global and local image quality metrics. From robustness analysis, CGAN-CDR can better recover the detailed bone structure of the reconstructed image for a higher-noise sinogram. This work demonstrates the feasibility and effectiveness of CGAN-CDR in low-dose SPECT sinogram restoration. CGAN-CDR can yield significant quality improvement in both projection and image domains, which enables potential applications of the proposed method in real low-dose study.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA