Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Cardiovasc Electrophysiol ; 28(4): 466-473, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28063271

RESUMO

INTRODUCTION: Despite the overall safety, transvenous lead extraction (TLE) remains a challenging procedure with inherent risks, where surgery can still be required in elective cases. In this study, we report our experience with a minimally invasive "hybrid" approach, defined as a procedure performed by an electrophysiologist with the support of a cardiac surgeon in the same operative session. METHODS AND RESULTS: We reported 12 cases of planned hybrid lead extraction; minithoracotomy and thoracoscopy were performed on 10 (83%) and 2 (17%) patients, respectively. A total of 25 leads out of 27 (median lead age 19 years) were successfully extracted with laser, mechanical or combined transvenous sheath. In 3 patients, the direct monitoring of vascular and myocardial integrity allowed for prompt treatment of potential vascular injury during the lead extraction maneuvers. Mean in-hospital stay was 4 ± 2 days. There were no major intraoperative complications and no deaths occurred after 30 days' follow-up. CONCLUSION: The hybrid approach, with minithoracotomy or thoracoscopy, is feasible and it might increase the safety in the most challenging TLE procedures: the minimally invasive surgical intervention allows for continuous monitoring of the critical cardiac structures and prompt treatment of potential complications.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Toracoscopia , Toracotomia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiologistas , Remoção de Dispositivo/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Humanos , Tempo de Internação , Masculino , Equipe de Assistência ao Paciente , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Cirurgiões , Toracoscopia/efeitos adversos , Toracotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
EuroIntervention ; 12(8): e1031-e1038, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-26485733

RESUMO

AIMS: Long-term data on the durability of currently available transcatheter heart valves are limited. We sought to assess four-year clinical and echocardiographic outcomes in patients undergoing transcatheter aortic valve implantation (TAVI) with the CoreValve prosthesis. METHODS AND RESULTS: Between June 2007 and February 2014, 450 consecutive patients with symptomatic severe aortic stenosis underwent TAVI in our institution. For the purposes of this study, we included only those patients undergoing successful TAVI with the CoreValve prosthesis who had a minimum follow-up of four years (n=125). Survival rates at one, two, three and four years were 83.2, 76.8, 73.6 and 66.3%, respectively. Aortic regurgitation was a common finding after the procedure, especially due to paravalvular regurgitation (PVR), which was observed in the majority of patients (71.5%), mostly mild (52.0%). Progression from mild acute PVR to moderate PVR at four-year follow-up was reported in three patients. No cases of severe PVR were observed. Prosthetic valve failure was reported in four patients (3.2%). CONCLUSIONS: Our study demonstrates that favourable outcomes after successful TAVI are associated with sustained clinical and functional cardiovascular benefits up to four-year follow-up. Signs of moderate prosthetic valve failure are present only in a small percentage of patients.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Falha de Prótese , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA