Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(4): 212, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480541

RESUMO

OBJECTIVES: To assess root canal localization accuracy using a dynamic approach, surgical guides and freehand technique in vitro. MATERIALS AND METHODS: Access cavities were prepared for 4 different 3D printed tooth types by 4 operators (n = 144). Deviations from the planning in angle and bur positioning were compared and operating time as well as tooth substance loss were evaluated (Kruskal-Wallis Test, ANOVA). Operating method, tooth type, and operator effects were analyzed (partial eta-squared statistic). RESULTS: Angle deviation varied significantly between the operating methods (p < .0001): freehand (9.53 ± 6.36°), dynamic (2.82 ± 1.8°) and static navigation (1.12 ± 0.85°). The highest effect size was calculated for operating method (ηP²=0.524), followed by tooth type (0.364), and operator (0.08). Regarding deviation of bur base and tip localization no significant difference was found between the methods. Operating method mainly influenced both parameters (ηP²=0.471, 0.379) with minor effects of tooth type (0.157) and operator. Freehand technique caused most substance loss (p < .001), dynamic navigation least (p < .0001). Operating time was the shortest for freehand followed by static and dynamic navigation. CONCLUSIONS: Guided endodontic access may aid in precise root canal localization and save tooth structure. CLINICAL RELEVANCE: Although guided endodontic access preparation may require more time compared to the freehand technique, the guided navigation is more accurate and saves tooth structure.


Assuntos
Endodontia , Dente , Preparo de Canal Radicular/métodos , Cavidade Pulpar/cirurgia , Tomografia Computadorizada de Feixe Cônico , Endodontia/métodos , Impressão Tridimensional
2.
J Prosthet Dent ; 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38853056

RESUMO

STATEMENT OF PROBLEM: Although bonding is important for long-term clinical success, studies on the bonding of additively manufactured ceramics are sparse. PURPOSE: The purpose of this in vitro study was to determine the influence of manufacturing methods, additive (LCM) versus subtractive (CAM). and ceramic materials, zirconia (ZrO2) and lithium disilicate (LiSi), on the tensile bond strength (TBS), failure mode, and surface roughness of ceramics. MATERIAL AND METHODS: A total of 240 ceramic specimens (n=60/group; 2×2×10 mm) were prepared. Two additively manufactured (LCM-printed) ceramics, LiSi and ZrO2 (Lithoz), subtractively manufactured LiSi (IPS e.max CAD), and subtractively manufactured ZrO2 (KATANA Zirconia HTML PLUS) were evaluated. From each material, 40 specimens were bonded together (n=20 ceramic-ceramic specimens/group), and 20 specimens were bonded to equally sized human dentin specimens (n=20 ceramic-dentin specimens/group). The ZrO2 specimens were airborne-particle abraded (Al2O3, 50 µm, 0.1 MPa), and the LiSi specimens were etched with hydrofluoric acid. Then, a universal primer (Monobond Plus) was applied. After the dentin was coated with an etch-and-rinse adhesive (Syntac Classic), the specimens were bonded with luting composite resin (Variolink Esthetic DC), light polymerized for 40 seconds, thermally aged (10 000 cycles between 5 °C and 55 °C), tested for TBS, and statistically analyzed (1- and 3-way ANOVA and Weibull analysis). The ceramic surface was examined with scanning electron microscopy, and surface roughness was measured with digital microscopy before and after surface pretreatment. RESULTS: TBS varied between 5.88 ±2.22 MPa and 6.34 ±2.26 MPa in the ceramic-dentin groups and 12.40 ±1.56 MPa and 18.82 ±5.92 MPa in the ceramic-ceramic groups. No significant difference was observed regarding the manufacturing method and material for different bonding conditions (P>.05). Additive and subtractive LiSi showed the highest reliability with m=18.27. The ceramic-ceramic specimens failed cohesively in the luting composite resin, whereas the ceramic-dentin specimens failed adhesively. CONCLUSIONS: The manufacturing method and material used had little effect on bond strength values or surface properties. The recently introduced printed materials performed similarly to conventionally milled materials.

3.
Eur J Dent Educ ; 28(1): 9-19, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37118941

RESUMO

INTRODUCTION: The application of virtual reality (VR) presents a big trend in medical education. The aim of this investigation was the presentation and assessment of a multi-user virtual prosthetic case planning environment using criteria such as perceived immersion, cognitive load, authenticity and students´ learning motivation during a virtual seminar. MATERIALS AND METHODS: The virtual case planning environment consisted of two different virtual environments - the entrance area and the case planning environment. Students and lecturers visited it with the used VR glasses Oculus Quest 2 (Meta Quest). All participants appeared as tooth avatars (molars) during the prosthetic case planning seminar and were able to communicate. These voluntary virtual case planning seminars took place in the clinical prosthetic courses (4th and 5th year). Students were asked to fill in the questionnaire comprising 15 questions separated into four categories, each assessed by a 11-point Likert scale: perceived presence/immersion, cognitive load, motivation and authenticity. A negative and a positive focus group were built, each consisting of three students answering three guiding questions. An exploratory data analysis was performed with the significance level set at p = .05. RESULTS: A total of 64 students out of 98 participated in the virtual seminars. The results demonstrated that the students felt very comfortable in the virtual seminar environment and were able to focus well on the content, demonstrated in predominantly positive results for presence/immersion. Cognitive load and authenticity presented positive results. In particular, the motivation of the students showed a high score (median: 2.1-2.6; IQR: 3.9). The cognitive load should be reduced if necessary to increase focus. The cyber sickness is a challenge for some students as well as the technical requirements of the internet connection, which needs to be addressed. Nevertheless, virtual case planning seminars are an essential tool for motivating the new generation of students. CONCLUSIONS: The results of the investigation demonstrate that the students felt very comfortable in the virtual seminar environment and were able to focus well on the content. The prosthetic case plannings were well understood and the students quickly become familiar with the environment. The cognitive load could be reduced to increase focus. In particular, the motivation of the students showed a high score. The cyber sickness is a challenge for some students as well as the technical requirements of the internet connection, which needs to be addressed.


Assuntos
Cognição , Motivação , Estudantes de Odontologia , Humanos , Educação em Odontologia , Estudantes de Odontologia/psicologia
4.
Clin Oral Investig ; 27(1): 31-43, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36441267

RESUMO

OBJECTIVES: The influence of different cleaning methods, air-abrasion parameters, and aging on shear bond strength (SBS) and tensile bond strength (TBS) of 3D resin luted to composite resin. MATERIALS AND METHODS: Nine hundred resin substrates were 3D printed (D20II, Rapid Shape) and cleaned with either isopropanol (ISO), butyldiglycol-based solution (BUT), or centrifugation (CEN). After 24-h storage in 37 °C water, specimens were air-abraded (mean particle size 50 µm; n = 60) with either alumina at 0.1 MPa (AL0.1) or 0.4 MPa (AL0.4) and glass pearls at 0.1 MPa (GP0.1) and 0.4 MPa (GP0.4) or conditioned with visio.link (control) and luted with PanaviaV5. Initially (24 h, 37 °C water storage) or after aging (10,000 thermal cycles), SBS and TBS were measured, and fracture types were examined. Surface free energy (SFE) and roughness (Ra) were determined after air-abrasion. Kolmogorov-Smirnov, Kruskal-Wallis H, Mann-Whitney U, chi-square, and partial eta-squared were computed. RESULTS: SBS measurements presented higher values than TBS (p < 0.001-0.033). Within the pretreatment groups, CEN showed the highest SBS and TBS values compared to cleaning with ISO or BUT (p < 0.001-0.040). Pretreatment with GP0.1 displayed the lowest bond strength values (p < 0.001-0.049), and mostly adhesive fractures occurred. The highest Ra values (p < 0.001) were observed for AL0.4 pretreatment. CONCLUSIONS: Pretreatment with AL0.4 and the control group mainly presented the highest bond strength values. Thermocycling had a positive effect on the bond strength. CLINICAL RELEVANCE: According to this study, 3D-printed restorations should be pretreated with AL0.4 or with visio.link before adhesive luting, regardless of their cleaning.


Assuntos
Colagem Dentária , Colagem Dentária/métodos , Propriedades de Superfície , Resinas Compostas/química , Resistência à Tração , Resistência ao Cisalhamento , Água , Cimentos de Resina/química , Teste de Materiais , Análise do Estresse Dentário
5.
Clin Oral Investig ; 27(8): 4389-4399, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37166534

RESUMO

OBJECTIVE: Evaluating various polishing methods after bracket debonding and excessive attachment material removal for different ceramics and pretreatments. MATERIAL AND METHODS: Zirconia (ZrO2), leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with a) silica coated alumina particles (CoJet); LEU and LiSi additionally with b) hydrofluoric acid (HF), c) Monobond Etch&Prime (MEP), d) silicium carbide grinder (SiC) before bracket bonding, shearing off, ARI evaluation, excessive attachment material removal and polishing with i) Sof-Lex Discs (Soflex), ii) polishing paste (Paste), iii) polishing set (Set). Before/after polishing surface roughness (Ra) was measured with a profilometer. Martens hardness parameter were also assessed. RESULTS: Irrespective of pretreatment Ra of LEU increased the most, followed by LiSi and ZrO2 (p < 0.001, SiC: p = 0.012), in accordance with the measured Martens hardness parameter. CoJet/SiC caused greater roughness as HF/MEP (p < 0.001). The ZrO2 surface was rougher after polishing with Paste/Set (p < 0.001; p = 0.047). Ra improved in the LEU/CoJet, LEU/SiC and LiSi/SiC groups with Soflex/Set (p < 0.001), in the LiSi/CoJet and LEU/HF groups by Soflex (p = 0.003, p < 0.001) and worsened by Paste (p = 0.017, p < 0.001). Polishing of HF or MEP pretreated LiSi with Set increased Ra (p = 0.001, p < 0.001), so did Paste in the LEU/MEP group (p < 0.001). CONCLUSIONS: Paste couldn't improve the surfaces. Soflex was the only method decreasing Ra on rough surfaces and not causing roughness worsening. Polishing of LEU/LiSi after MEP, LEU after HF pretreatment doesn´t seem to have any benefit. CLINICAL RELEVANCE: To avoid long-term damage to ceramic restorations, special attention should be paid to the polishing method after orthodontic treatment.


Assuntos
Cerâmica , Zircônio , Zircônio/química , Teste de Materiais , Cerâmica/química , Porcelana Dentária/química , Propriedades de Superfície , Polimento Dentário/métodos
6.
Clin Oral Investig ; 27(7): 4007-4016, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37086284

RESUMO

OBJECTIVES: A variety of dental materials are available for the fabrication of telescopic crowns. The aim was to investigate the impact of material combinations and removal and insertion cycles on their retention forces. MATERIALS AND METHODS: CAD/CAM-fabricated cobalt-chromium-molybdenum (CoCr) and zirconia (ZrO2) primary crowns were combined with polyetheretherketone (PEEK), polyetherketoneketone (PEKK), CoCr, and ZrO2 secondary crowns (four combinations included PEEK/PEKK secondary crowns in a thickness of 0.5 mm bonded to the CoCr tertiary construction), resulting in 12 different material combinations: CoCr-PEEK; CoCr-PEKK; CoCr-ZrO2; CoCr-CoCr; CoCr-PEEK 0.5; CoCr-PEKK 0.5; ZrO2-PEEK; ZrO2-PEKK; ZrO2-ZrO2, ZrO2-CoCr; ZrO2-PEEK 0.5; and ZrO2-PEKK 0.5 (n = 15 pairings per material combination). Pull-off tests were performed with a universal testing machine initially and after 500, 5000, and 10,000 removal and insertion cycles in a mastication simulator. Descriptive statistics with the Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests were computed (α = 0.05). RESULTS: The tested parameters, material combination, and removal and insertion cycles had significant impact on the retention force values (p < 0.001). An increase in removal and insertion cycles was associated with a decrease in retention forces within CoCr and ZrO2 secondary crowns, regardless of the primary crown material. In contrast, PEEK and PEKK secondary crowns presented higher retention load values after 10,000 cycles than initially. CONCLUSION: Different material combinations behaved differently after simulated removal and insertion regimens. This difference should be considered during treatment planning. CLINICAL RELEVANCE: Telescopic crown systems should be made of materials with predictable retention forces that do not deteriorate with time. The implementation of new materials and technologies facilitates reproducibility and time-saving fabrication.


Assuntos
Benzofenonas , Polímeros , Reprodutibilidade dos Testes , Polietilenoglicóis , Cetonas , Coroas , Análise do Estresse Dentário , Teste de Materiais
7.
Clin Oral Investig ; 27(7): 3415-3421, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37277537

RESUMO

OBJECTIVES: Long-term studies of modern zirconia implants are still insufficient. This prospective 8-year follow-up study investigated one-piece zirconia implants. MATERIALS AND METHODS: Patients who had received a one-piece zirconia dental implant (PURE ceramic implant, Institut Straumann GmbH, Basel, Switzerland) were included in this study. Next to the implant survival and success rates, the radiographic and clinical implant parameters were assessed. RESULTS: The overall survival rate of 67 zirconia implants in 39 patients was 100%. The overall success rate was 89.6%. Around the immediate zirconia implants, the success rate was 94.7%, and around the delayed implants, 87.5%. The immediate implants showed a significantly higher bone crest compared to the delayed implants (p = 0.0120). According to the pink esthetic score, the immediate implants revealed more favorable esthetic results compared to the delayed implants after an 8-year follow-up (p = 0.0002). CONCLUSIONS: After 8 years, the one-piece zirconia implants presented an 89.6% success rate. Regarding the timing of implantation, in individual cases, immediate implantation can have slight advantages over delayed implantation. CLINICAL RELEVANCE: Immediate implants can also be considered for zirconia implants and should not be excluded on principle.


Assuntos
Implantes Dentários , Humanos , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Estética Dentária , Zircônio
8.
J Esthet Restor Dent ; 35(1): 116-128, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35919964

RESUMO

OBJECTIVE: To report the long-term clinical survival and failure rates of single-tooth restorations made of pressable lithium disilicate ceramics (LS2 ) and CAD/CAM resin composite (RC) by two separate clinical observations. MATERIALS AND METHODS: Twenty-one patients (12 female, nine male) were treated with 436 minimally invasive single-tooth restorations made of 274 pressed LS2 (n = 12; posterior: monolithic IPS e.max Press; anterior: IPS e.max Ceram veneered, Ivoclar) or 162 milled from RC (n = 9; monolithic exp. CAD/CAM resin composite, Ivoclar). The mean age of patients was 44.1 ± 9.3 years and the mean observation time was 86.2 ± 13.5 months (7.7 ± 1.1 years), with 8.5 ± 2.7 years for LS2 and 6.7 ± 0.5 years for RC. All restorations were observed for technical/biological failures using the modified criteria of the United States Public Health Service (USPHS). Collected data were analyzed using Kaplan-Meier survival analysis and log-rank test (α < 0.025). RESULTS: The 274 LS2 restorations showed a survival of 100% and a total failure rate of 5.5%. The 162 RC restorations showed a survival of 100% and a total failure rate of 25.3%. RC restorations exhibited more material fractures (p = 0.020) and higher discoloration rates (p < 0.001). CONCLUSIONS: Pressed LS2 single-tooth restorations showed lower long-term failure rates than restorations made of RC. CLINICAL SIGNIFICANCE: Despite the limitations of the clinical observations, single-tooth restorations of both materials can be recommended for permanent use in patients with severe tooth wear.


Assuntos
Porcelana Dentária , Desgaste dos Dentes , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cerâmica , Resinas Compostas , Desenho Assistido por Computador , Teste de Materiais , Falha de Restauração Dentária
9.
J Prosthet Dent ; 130(4): 639-645, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34930599

RESUMO

STATEMENT OF PROBLEM: High-speed sintering allows the rapid fabrication of esthetic restorations with adequate flexural strength. However, data on the fatigue behavior of high-speed sintered 4 mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP) are lacking. PURPOSE: The purpose of this in vitro study was to examine the effect of high-speed sintering and the preshading of blanks (monochrome versus multilayer) on the fatigue behavior of 4Y-TZP ceramics. MATERIAL AND METHODS: Four-point flexural strength specimens (N=405) were fabricated from high-speed sintered multilayer 4Y-TZP (Zolid DRS) processed at 1580 °C for about 20 minutes and conventionally sintered at 1450 °C for about 10 hours, multilayer 4Y-TZP (Zolid Gen-x), and monochrome 4Y-TZP (Ceramill Zolid HT+PS), the control group. The specimens were loaded under 5 different dynamic test conditions for fatigue testing (P1-P5). Three were step-stress protocols (P1: 50 N for 5000 cycles; P2: 10 N for 1000 cycles, P3: 5% for 5000 cycles), 1 was tested with a constant force of 720 N (P4), and 1 was tested for different constant load levels (P5). For analysis of P1-P3, the Kaplan-Meier test and Mantel Cox test were performed (α=.05). P4 was analyzed with the Kolmogorov-Smirnov, Kruskal-Wallis, and Mann-Whitney U tests, and P5 by creating a load-cycle diagram. A fracture analysis was performed. RESULTS: ZMLC showed better fatigue behavior than ZMLH (P≤.006) and ZMOC (P≤.002) in all 3 step-stress protocols (P1-P3). ZMLH showed results comparable with those for ZMOC (P≥.285). In P4 and P5, all materials showed comparable values (P=.163 for P4). CONCLUSIONS: The multilayer technique showed a positive effect on the fatigue behavior of 4Y-TZP. In contrast, high-speed sintering negatively influenced the fatigue behavior of multilayer 4Y-TZP. The high-speed sintered material showed no deterioration compared with the conventional sintered monochrome material.

10.
J Oral Implantol ; 49(1): 39-45, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446931

RESUMO

Medication-related osteonecrosis of the jaw (MRONJ) is a serious concern for dentists as well as maxillofacial surgeons. Therefore, the safety of dental implant placement in patient receiving antiresorptive drugs (ARDs) has been the subject of controversial debate for several years and remains a source of uncertainty for surgeons and patients. This consecutive case series assessed the clinical and radiographic outcomes of dental implants placed in patients under antiresorptive therapy. Patients who received at least one dental implant at the Department of Oral and Maxillofacial Surgery, Ludwig Maximilian University (LMU), Munich, Germany, between 2010 and 2019 with a history of current or past antiresorptive medication were included the study. The main outcomes were occurrence of MRONJ, implant success, and survival rate. A total of 16 patients were treated with 39 implants. No implant loss or MRONJ occurred in the respective patients. The reasons for antiresorptive intake were osteoporosis, malignancy, edema of bone marrow, or diffuse sclerosing osteomyelitis (DSO). MRONJ occurred neither around implants nor in other locations. Cumulative implant success was 92.6% (25 of 27). No subjective complaints or postoperative complications were documented. Mean bone loss was 0.60 ± 0.98 mm. The prevalence of peri-implantitis was 30% on patient level and 29.6% on implant level. None of the patients had failed implants. No major complications after implant placement under antiresorptives could be detected. As long as implant surgery follows a specific protocol, implant placement in patients treated with antiresorptive therapy seems to be safe and predictable.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Implantes Dentários , Peri-Implantite , Humanos , Conservadores da Densidade Óssea/efeitos adversos , Implantes Dentários/efeitos adversos , Difosfonatos/efeitos adversos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Peri-Implantite/diagnóstico por imagem , Peri-Implantite/tratamento farmacológico
11.
BMC Med Educ ; 22(1): 872, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36527078

RESUMO

BACKGROUND: Digital teaching and learning tools, such as computer/mobile apps, are becoming an important factor in modern university education. The objective of our study was to introduce, analyze, and assess an organization and dual assessment app for clinical courses in dental medicine. METHODS: This was a survey-based study of dental students from the clinical study phase (4th/5th year; 8th/10th semester) of a department of prosthetic dentistry at a German university hospital about the benefits of a novel web-based and mobile app for organization and dual assessment of dental clinical courses. A total of eight questions were answered in an anonymous online survey. Data were analyzed using the Kolmogorov-Smirnov test, followed by an exploratory data analysis (α < 0.05). RESULTS: The app was given an average grade of 2.4, whereby 56.9% of the respondents rated the app with a grade of 2 (2 = good). In all, 94.6% of the study participants had not experienced any technical problems when using the app. Concerning the assessment, teaching doctor assessment (51.5 [IQR: 44.0]) was rated significantly better (p = 0.002) than self-assessment (39.5 [IQR: 32.8]). CONCLUSIONS: This investigation evaluated a newly introduced app to optimize dental clinical course workflows and assessment. The organizational feature was rated as good, while the daily self- and teaching doctor assessments were evaluated as less important. The results outline how the use of app technologies can provide an infrastructure for managing organization and daily assessments in dental education.


Assuntos
Aplicativos Móveis , Médicos , Humanos , Aprendizagem , Inquéritos e Questionários , Progressão da Doença
12.
Clin Oral Investig ; 25(4): 2191-2201, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32852596

RESUMO

OBJECTIVES: To analyze the oral health-related impact profile in patients treated with three different types of dental prosthesis in student courses. MATERIALS AND METHODS: This prospective bicenter clinical trial was conducted with 151 patients being treated with fixed (n = 70), removable (n = 61), or telescopic dental prostheses (n = 20) in clinical student courses of two German universities from October 2018 to October 2019. All patients completed three standardized German versions of the Oral Health Impact Profile (OHIP-G49/53) before prosthetic treatment (T0), at control after 1 week (T1), and after 3 months (T2), divided into five dimensions: (a) appearance, (b) oral function, (c) psychosocial impact, (d) linguistic limitations, and (e) orofacial pain. Data were analyzed with Kolmogorov-Smirnov, Wilcoxon signed-rank, Kruskal-Wallis, Mann-Whitney, and Cronbach's alpha tests. RESULTS: Within T0-T1 and T0-T2, greater improvements were determined for removable compared with fixed dental prostheses for the dimensions' oral function (p ≤ 0.014), linguistic limitations (p ≤ 0.016), and appearance (p ≤ 0.003). No significant differences were found between fixed and telescopic dental prostheses (p ≥ 0.104) or between removable (partial dental prosthesis with clasps and complete dental prosthesis) and telescopic dental prostheses (p ≥ 0.100). Within T1-T2, a significant improvement in orofacial pain could be determined (p = 0.007). CONCLUSIONS: Restorations presented an improvement in oral health-related quality of life. Removable dental prostheses showed better improvement than fixed ones in various dimensions. CLINICAL RELEVANCE: Knowledge about the influence of oral health-related quality of life on the three different types of prosthesis used in student courses can be of decisive help in dental consultations.


Assuntos
Prótese Dentária , Prótese Parcial Removível , Prótese Dentária Fixada por Implante , Humanos , Saúde Bucal , Estudos Prospectivos , Qualidade de Vida , Estudantes
13.
J Esthet Restor Dent ; 33(5): 786-794, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33949098

RESUMO

OBJECTIVE: To analyze the impact of the color of a resin composite cement (RCC) on the optical properties of different computer-aided design and computer-aided manufacturing (CAD/CAM) ceramics. MATERIALS AND METHODS: Specimens (N = 220, thickness: 0.9 ± 0.03 mm) were fabricated from: leucite (Initial LRF Block/IPS Empress CAD), lithium disilicate (Amber Mill/IPS e.max CAD), lithium metasilicate (Celtra Duo), and lithium alumina silicate ceramic (n!ce) in translucency levels HT and LT. All specimens were bonded with an RCC (Light+/Warm+). Color was analyzed (spectrophotometer) initially as well as after bonding of RCC with CAD/CAM ceramics using CIELab and CIEDE2000. Kolmogorov-Smirnov test, one-way ANOVA and t test served for analyzing (α = 0.05). RESULTS: Highest impact on ΔE presented the choice of ceramic (ηp2  = 0.155/p < 0.001), followed by translucency level (HT/LT; ηp2  = 0.050/p = 0.001) as well as interaction between ceramic and translucency level (ηp2  = 0.175/p < 0.001). ΔE00 was mainly influenced by the choice of ceramic (ηp2  = 0.490/p < 0.001), the shade of resin composite (ηp2  = 0.031/p = 0.012) as well as the interaction between ceramic and resin composite (ηp2  = 0.258/p < 0.001). CONCLUSIONS: RCC shades presented differential impacts on color change of CAD/CAM ceramics. CLINICAL SIGNIFICANCE: Knowledge of the impact of available RCC shades on different CAD/CAM ceramics is crucial for an esthetic outcome and proper selection of ceramic restorations.


Assuntos
Porcelana Dentária , Cimentos de Resina , Cerâmica , Cor , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície
14.
J Prosthet Dent ; 125(6): 940-945, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32624221

RESUMO

STATEMENT OF PROBLEM: Veneering composite resins (VCRs) are often used to veneer frameworks, but knowledge of mechanical, surface, and discoloring properties is scarce. PURPOSE: The purpose of this in vitro study was to evaluate the impact of thermocycling on flexural strength (FS) and the influence of different staining media on the discoloration (ΔE) and surface free energy (SFE) of VCRs. MATERIAL AND METHODS: The following VCRs were tested: Ceramage, dialog Vario, Gradia Plus, in:joy, Signum composite, and SR Nexco. FS was tested with enamel and dentin pastes (except SR Nexco: only enamel paste), whereas ΔE and SFE were analyzed for enamel pastes. ΔE was determined by using a spectrophotometer, and SFE was evaluated with contact angle measurements. For FS, rod-shaped specimens (N=660, n=10/subgroup; 25×2×2 mm) were fabricated, thermocycled for 220, 1500, 10 000, 20 000, and 40 000 cycles (5 °C/55 °C). and tested immediately after fabrication (initial) and after aging. For ΔE and SFE, disc-shaped specimens (N=300, n=10/subgroup; 15x15x1.4 mm) were fabricated and stored for 14 days in coffee, red wine, carrot juice, beetroot juice, or curry solution. ΔE and SFE were measured initially after polishing, after discoloration, and after repolishing. Data were analyzed using univariate analysis, 1-way ANOVA followed by the Scheffé post hoc test, Kolmogorov-Smirnov test, Kruskal-Wallis test, Mann-Whitney U test, and Wilcoxon test (α=.05). RESULTS: Ceramage had the highest FS, followed by dialog Vario and SR Nexco. Gradia Plus, and in:joy had the lowest FS, followed by Signum composite. FS was reduced by increasing of thermocycles. The highest ΔE was measured for curry and the lowest for carrot juice and red wine, followed by beetroot juice and coffee. The highest ΔE between the initial polished specimens and repolished specimens were observed for Ceramage. The remaining VCRs showed differences in ΔE between 0.95 (Signum composite) and 1.30 (SR Nexco). The SFE of the VCRs was similar. After storage in discoloring media, all VCRs had higher SFE than directly after polishing (initial). Repolishing decreased the SFE values compared with those of specimens measured after storage. CONCLUSIONS: FS, ΔE, and SFE differed between the VCRs tested. Discoloration of the VCRs depended on the food and beverage and could be corrected to a clinically acceptable range by repolishing.


Assuntos
Resinas Compostas , Cor , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
15.
Clin Oral Investig ; 24(12): 4519-4530, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32424461

RESUMO

OBJECTIVES: To analyse the residual monomer (MMA) elution of polymethyl methacrylate (PMMA) in distilled water after diverse fabrication methods and aging procedures. MATERIALS AND METHODS: PMMA specimens (N = 192, PalaXpress; Kulzer, Hanau, Germany) were manufactured (pouring, n = 96/injection, n = 96) and polymerized in water (55°C) without pressure (n = 48) and with 2 bar pressure (n = 48). Specimens were grinded (n = 24) or polished (n = 24) and aged for 12 h in distilled water/37°C (n = 12) or at air/20°C (n = 12) and stored afterwards in distilled water at 37°C. MMA elution was evaluated after 1, 2, 3, 4, 5, 6, 7, 10, 15 days (UV/Vis spectrophotometry). Data were analysed with Kolmogorov-Smirnov, Mann-Whitney-U and Cohen-d test using SPSS (α < 0.5). RESULTS: The pouring procedure resulted in significantly higher MMA elution than the injection procedure up to 5 days. Polymerization with a pressure of 2 bar reduced the MMA elution significantly for poured specimens. Polishing reduced the MMA elution in comparison to grinding. CONCLUSIONS: The fabrication procedure (pouring/injection) showed the strongest correlation to the MMA elution (r = 0.500), followed by polishing (r = 0.243), the pressure during polymerization (r = 0.109) and the storage medium (r = 0.053). CLINICAL RELEVANCE: Higher MMA elution may increase the risk of chemical irritations, allergic reactions and hypersensitivities of the oral mucosa. Technicians and dentists should be aware about the elution differences dependent on the fabrication procedure.


Assuntos
Bases de Dentadura , Polimetil Metacrilato , Resinas Acrílicas , Materiais Dentários , Alemanha , Teste de Materiais , Espectrofotometria
16.
Clin Oral Investig ; 24(1): 277-284, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31098712

RESUMO

OBJECTIVES: Analyze and quantify the residual monomer elution of nine conventional and CAD/CAM (computer-aided design/computer-aided manufacturing) dental polymers during artificial aging. MATERIALS AND METHODS: A total of 360 square-shaped specimens (14 × 12 × 2 ± 0.05 mm) were fabricated from eight CAD/CAM polymer blanks (n = 40): Avadent Base material, Avadent Teeth material, PMMA Multi blank, PMMA Mono blank, Temp Premium, Telio CAD, Ceramill Temp, Shofu Block HC, and conventional polymer PalaXpress. Specimens were aged in distilled water for 60 days at 37 °C and the evaluation of the residual monomer elution was made through UV spectrophotometry. Statistical analysis was carried out in the SPSS software. One-way ANOVA and Scheffé post hoc test were applied (α < 0.05). RESULTS: Aging time significantly changed the elution in all groups, except for PalaXpress. Statistically significant differences of elution were found between the materials. Shofu Block HC presented the highest, whereas PMMA Multi blank A3 and Mono blank A1 presented the lowest elution after the 60th day of aging. CONCLUSIONS: CAD/CAM dental polymers as well as the conventional polymer PalaXpress eluted residual monomer within aging time. The differences in elution were material-dependent; still, the maximum elution found is below the specified threshold of ISO standard 20795-1. CLINICAL RELEVANCE: With the evolution of CAD/CAM technology, material's manufacturers have invested in the development of polymeric materials with higher resistance and stability to produce indirect restorations using CAD/CAM. It is expected that these materials present lower elution of residual monomer than conventional polymers.


Assuntos
Desenho Assistido por Computador , Materiais Dentários , Polímeros , Polimetil Metacrilato , Teste de Materiais , Propriedades de Superfície
17.
Clin Oral Investig ; 23(1): 327-335, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29658069

RESUMO

OBJECTIVES: To investigate discoloration reduction and changes of surface properties of a CAD/CAM resin composite after 14 days´ storage in red wine and polishing with nine different prophylactic polishing pastes (PPPs). MATERIALS AND METHODS: Rectangular discs (N = 172) were fabricated and polished (P4000) using GC Cerasmart (GC Europe) to investigate different polishing protocols with 1-4 related descending PPPs (22 in total): Cleanic/CLE-Kerr, CleanJoy/CLJ-Voco, Clean Polish/Super Polish/SPO-Kerr, Clinpro Prophy Paste/CPP-3M, Détartrine/DET-Septodont, Nupro/NUP-Dentsply Sirona, Prophy Paste CCS/CCS-Directa, Proxyt/PXT-Ivoclar Vivadent, and Zircate/ZIR Prophy Paste-Dentsply Sirona. Surface properties (roughness values (RV)/Ra, Rz, Rv, surface free energy (SFE), surface gloss (G), and discoloration (ΔE)) were analyzed before and after storage and additional polishing. Data were examined using Kolmogorov-Smirnov test, three-way ANOVA followed by Tukey-B post hoc, Mann-Whitney U, and Kruskal-Wallis H tests (α < 0.05). RESULTS: Regarding RV, CLE, followed by CCS, and CPP showed the highest values; the lowest presented SPO and DET (p < 0.001). No impact of PPP was observed on ΔE values (p = 0.160). The lowest SFE presented DET, followed by SPO; highest showed CCS followed by NUP and CPP (p < 0.001). Within G, lowest values were observed for CLE and NUP, followed by CCS, ZIP, and CLJ (p < 0.001); the highest presented SPO (p < 0.001). Polishing showed generally a positive impact on SFE values (p < 0.001-p = 0.007), except ZIP (p = 0.322) and CLE (p = 0.083). G increased and RV decreased after polishing (p < 0.001), except SPO, with no significant change for G (p = 0.786). CONCLUSIONS: Polishing with PPPs improves the surface properties and is generally recommended. The choice of PPP has a minor role in removing discolorations. Multi-step systems should be carried out conscientiously. CLINICAL RELEVANCE: The proper selection of PPP is essential for the clinical outcome of surface properties of prosthetic restorations. Not every polishing paste leads to the same final surface quality.


Assuntos
Resinas Compostas/química , Polimento Dentário/métodos , Profilaxia Dentária/métodos , Restauração Dentária Permanente , Cremes Dentais/química , Desenho Assistido por Computador , Teste de Materiais , Propriedades de Superfície , Descoloração de Dente/prevenção & controle , Vinho
18.
J Esthet Restor Dent ; 31(3): 179-189, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30609191

RESUMO

OBJECTIVE: In severe congenital or acquired orofacial anomalies, both dental esthetics and function are usually compromised. In particular, the esthetic ideas of the final desired appearance may differ from patient to patient, as the human esthetic sensibility differs significantly. Especially in complex cases, digital technology today offers outstanding improvements and simplifications in craniomaxillofacial surgical and prosthetic treatments, leading to a wide range of planning and pretreatment options. CLINICAL CONSIDERATIONS: This case report describes a patient-oriented interdisciplinary craniomaxillofacial surgical and prosthetic treatment with noninvasive tooth-colored splints, a Le Fort I osteotomy, and a full-mouth rehabilitation to meet the patient's demand for better function as well as orofacial esthetics and harmony. CONCLUSIONS: By means of the digitally planned Le Fort I intervention and completion of the prosthetic rehabilitation, it was possible to optimize esthetics and facial harmony. CLINICAL SIGNIFICANCE: In complex cases, digital technology today offers outstanding improvements and simplifications in craniomaxillofacial surgery and prosthetic treatments, leading to a wide range of planning and pretreatment options. Computer-aided design/computer-aided manufacturing technology enables the fabrication of tooth-colored flexible polycarbonate splints that offer a noninvasive, removable, functional, and esthetic solution. In intricate cases involving craniomaxillofacial anomalies, often together with necessary orofacial surgeries or prosthetic treatments due to moderate to severe tooth wear, such digital preprosthetic treatment and planning options represent an important enhancement with more predictable results.


Assuntos
Desenho Assistido por Computador , Reabilitação Bucal , Estética , Estética Dentária , Humanos
19.
J Prosthet Dent ; 121(4): 683-689, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30527568

RESUMO

STATEMENT OF PROBLEM: Determining the relationship between variable thicknesses and the translucency of dental ceramics is essential for optimizing esthetics in different clinical situations. PURPOSE: The purpose of this in vitro study was to analyze the relationship between layer thickness and translucency of 2 multi-layered monolithic zirconia materials and to develop an equation by which the grade of translucency can be calculated dependent on the materials' layer thicknesses in advance. MATERIAL AND METHODS: Two semisintered multi-layered zirconia blanks, namely KATANA Zirconia Super Translucent Multi-Layered Disk (Noritake Dental Supply Co, Ltd) and Zirconia Ultra Translucent Multi-Layered Disk (UTML) (Noritake Dental Supply Co, Ltd), were sectioned (N=96) to separate the 4 layers (n=12 per layer): enamel layer, transition layer 1, transition layer 2, body layer. All specimens were sintered in a furnace (M2 Plus; Thermo-Star) at 1500°C for 2 hours and automatically polished under water cooling up to P2400 for the thicknesses of 1.6, 1.3, 1.0, 0.7, and 0.4 mm. Transmittance of visible light was measured using a spectrophotometer (Lambda 35; Perkin Elmer). Data were analyzed using the Kolmogorov-Smirnov, 2-way ANOVA, and Scheffé post hoc tests (α=.01) and curve fitting. RESULTS: Analyzing the fitting of the values of the 8 material groups to the linear, exponential, and logarithmic curves, 7 of the 8 groups (not UTML body layer) fitted the most (R-square value closer to 1.0) to the logarithmic curve. Constants were obtained from the distance to the x-axis and the curvature. CONCLUSIONS: The methodology of this study provided the materials' specific constants a and b by analyzing the translucency behavior of KATANA Super Translucent Multi-Layered Disk and Ultra Translucent Multi-Layered Disk in different thicknesses, allowing further translucency calculation by applying the developed formula and the constants.


Assuntos
Materiais Dentários , Estética Dentária , Cerâmica , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície , Zircônio
20.
J Esthet Restor Dent ; 30(1): 22-29, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28925546

RESUMO

OBJECTIVE: Oral rehabilitation often requires a multidisciplinary approach including restorative dentistry, prosthodontics, and periodontology to fulfill high esthetic and functional demands, frequently combined with changes in the vertical dimension. The presence of gingival recessions can be associated with numerous factors, such as brushing or preparation trauma and persistent inflammation of the gingiva due to inadequate marginal fit of restorations. Because gingival recessions can cause major esthetic and functional problems, obtaining stability of the gingival tissue around prosthetic restorations is of essential concern. Modifications of the occlusal vertical dimension require sufficient experience of the whole dental team. Especially in patients with functional problems and craniomandibular dysfunction, a newly defined occlusal position should be adequately tested and possibly adjusted. CLINICAL CONSIDERATIONS: This case report presents a complete prosthetic rehabilitation combined with a periodontal surgical approach for a patient with gingival recessions and functional/esthetic related problems. The vertical dimension was carefully defined through long-term polymethyl methacrylate provisionals as a communication tool between all parts involved. All-ceramic crowns were inserted after periodontal healing as definitive rehabilitation. CONCLUSIONS: Complex rehabilitation in patients with high esthetic demands including soft tissue corrections requires a multidisciplinary team approach that consists of periodontal surgeon, dentist and dental technician.


Assuntos
Retração Gengival , Reabilitação Bucal , Coroas , Estética Dentária , Humanos , Regeneração , Dimensão Vertical
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA