Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
2.
Transfusion ; 60(9): 1950-1959, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32687234

RESUMO

BACKGROUND: The study was designed to evaluate the ability of a novel electronic automatic notification system (EANS) to detect significant changes in transfusion-associated vital signs (VSs) during transfusion and to determine whether the EANS improved acute transfusion reaction (ATR) detection rates and suspected ATR reporting rates. STUDY DESIGN AND METHODS: VSs were measured three times per unit or batch product transfused:-before, 15 minutes after commencement, and at the completion of the transfusion-and recorded on the EANS. Significant changes in VSs were defined as increased temperature (≥38°C or ≥1°C change in baseline temperature), 20 mm Hg or 20% increase or decrease in systolic blood pressure, or 20% increase in pulse rate. The 6-month periods preceding and after the introduction of the EANS were defined as "before" and "after." Data from these periods were used for comparison and evaluation. RESULTS: During the after period, 945 notifications were reported from the EANS and 521 suspected ATR were detected. The suspected ATR reporting rates for the before and after were 0.29% (73/25 213) and 2.06% (521/25 304, P < .001) and the ATR detection rates before and after were 0.13% (33/25 213) and 0.49% (116/25 304, P < .001), respectively. Among 116 ATR cases, 49.1% could be detected only by significant changes in VSs. CONCLUSION: The EANS was very effective in detecting ATRs that could have been overlooked by medical staff. Further data are needed to demonstrate the extent to which the introduction of an EANS may improve the safety of transfused patients.


Assuntos
Transfusão de Sangue , Eletrônica , Software , Reação Transfusional , Sinais Vitais , Humanos , Monitorização Fisiológica , Reação Transfusional/diagnóstico , Reação Transfusional/fisiopatologia
3.
J Clin Lab Anal ; 31(6)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28124794

RESUMO

BACKGROUND: It is not easy to find natural red blood cells (RBCs) with weak A (Aw ) or weak B phenotype (Bw ) for use as quality controls in ABO subgroup testing (subgrouping). The aim of this study was to prepare RBC kodecytes with synthetic blood group A and/or B function-spacer-lipid (FSL) constructs and to evaluate the possibility of using such kodecytes as a survey material for an external proficiency test (PT) to improve the quality of subgroup analysis. METHODS: Three types of survey samples, including O phenotype RBCs and A kodecytes with Aw (0.02 mg/mL FSL-A solution) and B kodecytes with Bw (0.15 mg/mL FSL-B solution) were sent to 53 laboratories for an educational trial of PT for subgrouping. Cell typing was done using the manual tube technique. RESULTS: Forty-three laboratories responded, and the re-activities of the survey samples varied from 0 to 4+ against anti-A and anti-B monoclonal reagents(MoAbs). Twenty-nine laboratories (67%) correctly grouped the Bw kodecytes as Bw . Fifteen (35%), 21 (48%), and 6 (13%) laboratories grouped the Aw kodecytes as Aw , A2 , and O phenotypes, respectively. The anti-A MoAb clone affects the results of cell typing for Aw kodecytes. The stability of kodecytes was similar to that of natural O RBCs during storage. CONCLUSION: Our kodecytes were useful as a survey material, and the survey results showed the necessity of materials for PT for subgrouping to improve the quality of laboratory analysis regardless of the different reactions according to the MoAb.


Assuntos
Sistema ABO de Grupos Sanguíneos/classificação , Tipagem e Reações Cruzadas Sanguíneas/normas , Engenharia Celular , Ensaio de Proficiência Laboratorial/métodos , Lipídeos/química , Sistema ABO de Grupos Sanguíneos/química , Eritrócitos/química , Eritrócitos/citologia , Testes de Hemaglutinação , Humanos
4.
Ann Lab Med ; 44(4): 359-362, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237929

RESUMO

Neutralizing capacity measurement (NCM) of soluble ABH substances (SAS) in plasma was assessed to guide the selection of the appropriate ABO group of fresh-frozen plasma (FFP) for plasma exchange (PE) in blood group O recipients with ABO-incompatible transplantations. Neutralizing capacity was assessed by measuring anti-A and/or anti-B titers in samples comprising one unit of O FFP and 10 O EDTA plasma samples and subtracting the binary logarithm of the titer in each group with a saline dilution. Ten EDTA plasma samples with Lewis b (Leb) antigen positivity and 10 sets of pooled FFP from each blood group were used as diluents. In O FFP, the NCM values (mean±SD) were 3.4±0.52 (2.6±0.52) and 2.6±0.52 (1.5±0.3) in B and AB for IgM (total antibody) anti-B (both P<0.001), and in the 10 O EDTA plasma samples, they were 3.9±0.88 (3.1±0.88) and 3.2±0.79 (2.4±0.97) for IgM (P=0.0013) and total anti-B (P=0.025), respectively. In vitro analysis revealed that B FFP is more effective than AB FFP in reducing IgM and total anti-B antibody titers in O recipients, regardless of Leb antigen positivity.


Assuntos
Troca Plasmática , Plasma , Humanos , Ácido Edético , Incompatibilidade de Grupos Sanguíneos , Sistema ABO de Grupos Sanguíneos , Imunoglobulina M
5.
Ann Lab Med ; 44(3): 262-270, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38098300

RESUMO

Background: Maintaining optimal blood inventory levels in hospitals is important to prevent blood shortage and wastage. We aimed to provide an efficient blood inventory management strategy for hospital blood banks nation-wide by comparing the current use of 5-day issuable stock (IS) with Lim's IS as a novel target IS. Methods: The average and CV of daily usage (DU) were calculated from information entered into Korea's Blood Management System by 194 participating hospitals in 2019 and 2020. Using these data, Lim's IS was calculated by determining the simulated annual average blood shortage day nearest to 1 for each blood group in each hospital. The 5-day IS (5IS) was estimated by multiplying the average DU in 2018 by five to count the shortage days in 2019. Results: The average DU (0.3-231.3 units) and corresponding CV (0.33-7.14) in the participating hospitals were inversely proportional (r=-0.699 to -0.695). The hypothetical averages of 5IS and Lim's IS were 27.0±41.2 and 24.7±20.8, respectively (P=0.006). The shortage days for 5IS and Lim's IS were 8.9±22.7 and 1.0±1.9, respectively (P<0.001). Conclusions: While 5IS was unacceptable for universal application, Lim's IS remained near one shortage day and is considered more efficient than 5IS. Hospitals should implement indicators that consider DU and its variations. This is the first study to introduce Lim's IS as an indicator of optimal blood inventory, and the data are expected to provide guidance for effective blood inventory management nationwide, particularly during blood shortages.


Assuntos
Bancos de Sangue , Hospitais , Humanos , República da Coreia
6.
Ann Lab Med ; 42(6): 650-658, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35765873

RESUMO

Background: A paucity of studies evaluating failed cases of ABO grouping using autoanalyzers exists. We investigated autoanalyzer rejected cases, including serologically suspicious ABO subgroups and discrepant ABO blood grouping results from Erytra Eflexis (Grifols, Spain), to demonstrate efficient use of autoanalyzers for ABO grouping. Methods: Samples requested for ABO grouping throughout 2020 were tested using two Eflexis instruments and standard ABO RhD and reverse grouping cards. Neonatal cards were not used. When necessary, a conventional tube technique (TUBE) was used to resolve rejected/discrepant Eflexis ABO grouping results. Results: The overall sample rejection rate (RR) was 3.2% (628/19,466), 1.3% of which were due to various error flags and 1.9% for discrepant results. Cases from neonates ≤1 year old accounted for 35.3% of the rejected cases based on Eflexis results. The ABO groups with the highest and lowest RR (excluding neonates) were A and O, respectively. The 628 samples resulted in 682 rejections, which were frequently associated with reverse grouping, including 28.4% against A1 and 54.5% for B red cells. Among 14 serologically weakened A and/or B blood groups, six A2BW and two ABw, which had been missed by Eflexis, were detected using TUBE and our follow-up laboratory criteria. Conclusions: The ABO group and a proportion of neonatal samples influenced the RR due to weak reverse grouping reactivity, especially toward B red cells. Confirmatory ABO grouping by TUBE in a new patient and/or extra rejection criteria for forward grouping are needed to detect cis-AB, which is relatively common in Korea.


Assuntos
Sistema ABO de Grupos Sanguíneos , Tipagem e Reações Cruzadas Sanguíneas , Humanos , Lactente , Recém-Nascido , República da Coreia
7.
J Clin Lab Anal ; 24(1): 38-43, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20087952

RESUMO

An agonist-induced expression of CD62P by flow cytometry analysis for evaluating platelet functional reactivity has some disadvantages. We investigated the usefulness of platelet parameters by ADVIA 120 to predict an agonist-induced expression of CD62P in stored platelets. The CD62P expression by flow cytometry and the platelet parameters by ADVIA 120 were studied in samples from 27 platelet pheresis products. Delta (Delta) values were calculated as the degree of change of the platelet parameters studied with or without adenosine 5'-diphosphate sodium (ADP) stimulation. The CD62P expression of the ADP-activated platelets were correlated with the Delta platelet count (r=0.517) in the short-term storage group (within 10 hr from preparation), with the platelet component distribution width (PCDW) without ADP (r=-0.744) and the DeltaPCDW (r=-0.755) in the long-term storage group (after 10 hr from preparation). Therefore, the delta values of platelet parameters on ADVIA 120 analysis in platelets between with and without ADP stimulation could be useful as a simple predictor for the functional reactivity of stored platelets.


Assuntos
Plaquetas/fisiologia , Selectina-P/sangue , Difosfato de Adenosina/farmacologia , Plaquetas/citologia , Plaquetas/efeitos dos fármacos , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Testes Hematológicos/instrumentação , Testes Hematológicos/métodos , Humanos , Selectina-P/biossíntese , Estatísticas não Paramétricas
8.
Transfus Apher Sci ; 38(2): 93-100, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18359274

RESUMO

National apheresis registries can be used to evaluate changes in technology, clinical indications, and applications over the years. Since the establishment of the Korean Society of Apheresis (KSFA) in 1999, basic data on the status of apheresis have been collected using letters and e-mails on a biennial basis. In February 2006, a KSFA homepage and an on-line apheresis registry were constructed (http://www.apheresis.or.kr/). The registry consists of two sub-registries, one addressing overall aspects, e.g., the numbers and types of apheresis machines, total numbers of apheresis procedures, and the other addressing therapeutic plasmapheresis, e.g., diagnoses, modes of treatment, instrument used, replacement fluids, volumes processed, vascular access, anticoagulants, complications, and clinical responses. Data registered on-line is presumed to represent about 95% of total apheresis procedures performed in Korea. In this report, we introduce our on-line registry system and compared the data obtained by on-line registry with the previous ones.


Assuntos
Remoção de Componentes Sanguíneos/métodos , Troca Plasmática/métodos , Sistema de Registros , Sociedades Médicas , Remoção de Componentes Sanguíneos/instrumentação , Computadores , Humanos , Internet , Coreia (Geográfico) , Troca Plasmática/instrumentação , Plasmaferese , Software , Resultado do Tratamento
9.
Platelets ; 19(5): 328-34, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18791938

RESUMO

In spite of the frequent need of platelet transfusions, there is limited information on the association of platelet activation markers, in transfused patients with hematology/oncology disorders, with platelet function using flow cytometry. The goal of this study was to evaluate the changes of PAC-1 binding and CD62P expression, with or without agonists in patients after transfusions. Twenty-eight whole blood samples were obtained from 24 patients admitted to the department of Hematology & Oncology and transfused with platelets; these samples were compared to 30 healthy controls. Whole blood samples, either with or without agonists, such as 20 microM adenosine diphosphate (ADP) or 100 microM thrombin receptor activating peptide (TRAP), were stained with the fluorescein conjugated monoclonal antibodies PAC-1 or CD62P. Then, the percent expression for each marker was analysed using flow cytometry. ADP and TRAP induced an increased percentage of CD62P expression and PAC-1 binding after platelet transfusions compared to the samples studied before transfusion, and these findings were lower than those of the healthy controls. However, the expression of platelets without the agonists was not significantly changed, despite the transfusions. Therefore, agonist-induced platelet activation markers, studied by flow cytometry, appear to be more useful for the evaluation of platelet function after transfusions than platelet activation markers without agonists.


Assuntos
Anemia Aplástica/sangue , Citometria de Fluxo/métodos , Leucemia/sangue , Ativação Plaquetária , Transfusão de Plaquetas , Trombocitopenia/sangue , Difosfato de Adenosina/farmacologia , Adolescente , Adulto , Idoso , Anemia Aplástica/complicações , Antineoplásicos/efeitos adversos , Antineoplásicos/uso terapêutico , Biomarcadores , Feminino , Humanos , Leucemia/complicações , Leucemia/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Selectina-P/análise , Ativação Plaquetária/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/análise , Receptores de Fibrinogênio/análise , Receptores de Trombina , Trombocitopenia/induzido quimicamente , Trombocitopenia/etiologia , Trombocitopenia/terapia
10.
Ther Apher Dial ; 8(2): 97-101, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15255124

RESUMO

A nationwide survey on the status of plasma exchange in Korea was performed during the 2 year period 2001-02. Data from 496 patients were collected from 15 major hospitals. The most common indication was myasthenia gravis (15.3%), followed by thrombotic thrombocytopenic purpura (14.5%) and hemolytic uremic syndrome (9.7%). Clinical improvement was noted in 70.1% of the 415 cases. Plasma exchange by centrifugation alone accounted for 92.4%. Postcentrifugal filtration was carried out in 5.6% and double filtration in 2.0% of treatments. The most common instruments for the centrifugation were Cobe Spectra (71.3%) and Fenwal CS3000 (15.8%). Filtration was performed by either Kuraray KM8300 or Kuraray KM8800. The overall frequency of complications was 11.1% (293/2647 cases), of which symptomatic hypocalcemia was the most common (2.3%).


Assuntos
Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Troca Plasmática/estatística & dados numéricos , Sistema de Registros , Síndrome Hemolítico-Urêmica/epidemiologia , Síndrome Hemolítico-Urêmica/terapia , Humanos , Coreia (Geográfico)/epidemiologia , Miastenia Gravis/epidemiologia , Miastenia Gravis/terapia , Troca Plasmática/instrumentação , Troca Plasmática/métodos , Púrpura Trombocitopênica Trombótica/epidemiologia , Púrpura Trombocitopênica Trombótica/terapia
11.
Ann Lab Med ; 34(6): 456-62, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25368821

RESUMO

BACKGROUND: Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the methods and results of ABO Ab titers. METHODS: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recommended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). RESULTS: Several interlaboratory variations were observed in the results, technical procedures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories (P=0.006) than the tube test. CONCLUSIONS: Our study provides baseline data regarding the current status of ABO Ab titer measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.


Assuntos
Sistema ABO de Grupos Sanguíneos/imunologia , Testes de Aglutinação/normas , Anticorpos/análise , Laboratórios/normas , Humanos , Imunoglobulina G/análise , Imunoglobulina M/análise , República da Coreia , Inquéritos e Questionários , Temperatura
12.
Ann Lab Med ; 34(4): 300-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24982835

RESUMO

BACKGROUND: Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers. METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs. RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O. CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.


Assuntos
Sistema ABO de Grupos Sanguíneos/imunologia , Testes de Aglutinação/normas , Anticorpos/análise , Citometria de Fluxo , Adulto , Idoso , Testes de Aglutinação/instrumentação , Anticorpos Anti-Idiotípicos/análise , Eritrócitos/química , Eritrócitos/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Temperatura
13.
Ann Lab Med ; 34(1): 43-50, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24422195

RESUMO

BACKGROUND: Standard protocols are lacking for the preparation of platelet lysates (PL) as an alternative to using fetal bovine serum as a cell culture supplement. This study aimed to establish optimum conditions for preparing PL for use in cell cultures. METHODS: Cell density in three pooled platelet concentrates (PC) were adjusted to 1×10(12)/L and 2×10(12)/L. PL was prepared from PC by 1 to 3 freeze-thaw (FT) cycles. HaCaT cells were cultured in media supplemented with 5% or 10% PL. Cell numbers were estimated using a Cell Counting Kit-8 (CCK-8; Dojindo Laboratories, Japan). Growth factors were quantified by using the Luminex 200 system (Luminex Corporation, USA). RESULTS: Cell proliferation rates in the presence of PLs were similar when prepared from PCs of both cell densities. The rates were higher in media containing 5% PL than 10% PL when prepared by two FT cycles. Concentrations of vascular endothelial growth factor (VEGF), platelet-derived growth factor-AB/BB (PDGF-AB/BB), PDGF-AA, and epidermal growth factor (EGF) were significantly higher in PL prepared from PC with a cell density of 2×10(12)/L than 1×10(12)/L PC. However, only VEGF and PDGF-AA concentrations in PLs were correlated with HaCaT cell counts. CONCLUSIONS: The 5% PL from PC with a cell density of 1×10(12)/L prepared by two FT cycles treatment was the most effective condition that supported steady HaCaT cell proliferation. Our finding may be useful for preparing PL-supplemented cell culture media.


Assuntos
Plaquetas/metabolismo , Plaquetas/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Meios de Cultura/farmacologia , Fator de Crescimento Epidérmico/química , Fator de Crescimento Epidérmico/farmacologia , Humanos , Fator de Crescimento Derivado de Plaquetas/química , Fator de Crescimento Derivado de Plaquetas/farmacologia , Fator A de Crescimento do Endotélio Vascular/química , Fator A de Crescimento do Endotélio Vascular/farmacologia
14.
Ann Clin Lab Sci ; 43(2): 186-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23694795

RESUMO

Blasts showing hemophagocytosis have been very rarely reported in acute lymphoblastic leukemia. We report a pediatric case of B lymphoblastic leukemia (BLL) with t(12;21)(p13;q22); TEL-AML1 (ETV6-RUNX1) showing erythrophagocytosis and thrombophagocytosis by leukemic blasts. About 4% of the leukemic blasts in marrow aspirate smears showed phagocytosis of erythrocytes, platelets, or nuclear remnants in a 3-year-old Korean boy with a diagnosis of BLL. Conventional cytogenetics and molecular analysis revealed the presence of t(12;21)(p13;q22); TEL-AML1 (ETV6-RUNX1). The patient responded well to chemotherapy and is in a state of complete remission.


Assuntos
Cromossomos Humanos Par 12/genética , Cromossomos Humanos Par 13/genética , Subunidade alfa 2 de Fator de Ligação ao Core/genética , Células Progenitoras Mieloides/fisiologia , Proteínas de Fusão Oncogênica/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/patologia , Translocação Genética/genética , Pré-Escolar , Análise Citogenética , Eritrócitos/fisiologia , Humanos , Imunofenotipagem , Masculino , Fagocitose/fisiologia , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamento farmacológico , República da Coreia
15.
Thromb Res ; 131(4): e147-53, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23477707

RESUMO

BACKGROUND: Even though clopidogrel is the most used drug for cardiovascular prevention, resistance occurs in significant numbers. Therefore, we evaluated platelet aggregation ability of thienopyridines in relation with various genotypes. METHOD: The study population was randomly assigned with clopidogrel (n=43), ticlopidine (n=41), or ticlopidine plus Gingko Biloba extract (EGb) (n=43). Dosage was maintained as 75mg clopidogrel daily, 250mg ticlopidine twice daily, and 250mg ticlopidine plus 80mg Gingko Biloba extract twice daily. Using multiple electrodes aggregometry, platelet aggregation was measured by activators of adenosine diphosphate (ADP), arachidonic acid (ASP), and thrombin (TRAP) at baseline (T0), 7days (T1), and 90days (T2). Side-effects were analyzed in the 3 groups. Inhibition of platelet aggregation (IPA) was defined as percent decrease at T0 and T1. Non-responsiveness (

Assuntos
Isquemia Encefálica/tratamento farmacológico , Ginkgo biloba/química , Extratos Vegetais/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Doença Aguda , Alelos , Hidrocarboneto de Aril Hidroxilases/genética , Isquemia Encefálica/sangue , Isquemia Encefálica/genética , Clopidogrel , Citocromo P-450 CYP2C19 , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Extratos Vegetais/efeitos adversos , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Ticlopidina/efeitos adversos
16.
J Korean Surg Soc ; 83(4): 203-11, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23091792

RESUMO

PURPOSE: The goal of this study was to assess the correlation between the Helicobacter pylori status of patients who underwent curative resection for gastric adenocarcinoma and their prognosis in Eastern societies where H. pylori infection is prevalent. METHODS: Between 2006 and 2007, 192 patients who had a curative resection for the treatment of gastric adenocarcinoma were enrolled in the study. Of these patients, 18 were excluded due to an inexact evaluation of the H. pylori status, thereby leaving 174 patients in the final analysis. Serologic testing for H. pylori was assessed using an enzyme-linked immunosorbent assay kit for immunoglobulin G, and the histological presence of H. pylori was identified using the Giemsa stain. RESULTS: Of the 174 patients, 111 patients (63.8%) were confirmed for H. pylori infection. H. pylori status did not correlate with the overall or disease-free survival. For patients with stage III or IV gastric cancer, a positive H. pylori status was a significant predictive factor for recurrence over that of a negative H. pylori status (P = 0.019). Negative H. pylori status was a predictive factor for recurrence in multivariable analysis (relative risk, 2.724; 95 confidence interval, 1.192 to 6.228). CONCLUSION: Helicobacter pylori status did not correlate with the clinicopathologic factors of gastric adenocarcinoma. However, a negative Helicobacter pylori status may be a predictive factor for recurrence in patients diagnosed with advanced gastric adenocarcinoma.

19.
Korean J Lab Med ; 29(1): 59-65, 2009 Feb.
Artigo em Coreano | MEDLINE | ID: mdl-19262080

RESUMO

BACKGROUND: The aim of this study was to report the first experience of using tests of antibody to hepatitis B core antigen (anti-HBc) and antibody to hepatitis B surface antigen (anti-HBs) for the selection of blood donors in a tertiary hospital blood center in Korea. METHODS: From January 2005 to December 2007, the data of all eligible donors according to the Korean Blood Regulation Law were analyzed. Anti-HBc testing was performed in all donors, but anti-HBs was tested only in anti-HBc seropositive donors. Anti-HBs negative but anti-HBc positive donors were regarded as ineligible for blood donation. Cost for donor testing was calculated based on Korean health insurance payment schedule from 2005 to 2007. RESULTS: The seroprevalence of anti-HBc in blood donors was 23.2% (162/699) and increased with increasing age. The proportion of ineligible donors for blood collection was 2.7% (19/699) of total donors and 11.6% (19/162) of anti-HBc seropositive donors. The cost of testing for anti-HBc and anti-HBs was estimated to be about 40% of the total screening cost. CONCLUSIONS: Although additional donor screening tests for anti-HBc and anti-HBs requires increased cost and relatively small number of donors are additionally excluded by these tests, they are considered to be helpful for the safety of blood products, because our blood center has characteristics with small number of donors and relatively high percentage of donors in the age group of thirties and older.


Assuntos
Doadores de Sangue , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/imunologia , Antígenos de Superfície da Hepatite B/imunologia , Adolescente , Adulto , Fatores Etários , Bancos de Sangue , Hepatite B/diagnóstico , Hepatite B/economia , Humanos , Coreia (Geográfico) , Laboratórios Hospitalares , Pessoa de Meia-Idade , Estudos Soroepidemiológicos , Testes Sorológicos/economia
20.
Korean J Lab Med ; 29(3): 238-42, 2009 Jun.
Artigo em Coreano | MEDLINE | ID: mdl-19571622

RESUMO

Knull phenotype completely lacks all Kell system antigens. Anti-Ku antibody is seen in immunized persons with Knull phenotype by transfusion or pregnancy. It can cause a fatal hemolytic transfusion reaction. A 66-yr-old male patient with liver cirrhosis visited emergency center due to acute bleeding. The patient was at hypovolemic shock status: his blood pressure was 80/50 mmHg, pulse rate was 110/min and hemoglobin level was 4.4 g/dL. Because of the presence of antibody against high incidence antigen, we could not find any compatible blood for the patient. Nevertheless, 4 units of packed RBCs had to be transfused. Moderate hemolytic transfusion reaction was developed after transfusion. At endoscopic examination, blood was spurting from gastric cardiac varix. Endoscopic histoacryl injection was tried, and bleeding was successfully controlled. After bleeding stopped, he was managed for anemia using steroid and other medical therapy instead of transfusion. His hemoglobin level was improved to 7.7 g/dL at the time of discharge. Later he has been proved to have a Knull phenotype, which is very rare, and anti-Ku antibody. This report is the first case of anti-Ku in a Knull phenotype person in Korea, who experienced a moderate hemolytic transfusion reaction.


Assuntos
Antígenos Nucleares/imunologia , Proteínas de Ligação a DNA/imunologia , Sistema do Grupo Sanguíneo de Kell/genética , Reação Transfusional , Idoso , Incompatibilidade de Grupos Sanguíneos , Humanos , Isoanticorpos/sangue , Coreia (Geográfico) , Autoantígeno Ku , Masculino , Fenótipo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA