Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38875184

RESUMO

PURPOSE: Evaluate effectiveness and safety of a crosslinked hyaluronate (HA) canalicular filler (Lacrifill Canalicular Gel) compared to a commercially available hydrogel canalicular plug (Form Fit). SETTING: 5 sites in United States. DESIGN: Prospective, multicenter, controlled, double-masked, randomized 2:1 (filler:plug). METHODS: Adults (≥22 years) with Schirmer test (with anesthesia) ≤10 mm/5 minutes, presence of corneal staining, ocular surface disease index (OSDI) of ≥23 with ≤3 responses of "not applicable," patent lacrimal drainage system, and bilateral best-corrected distance visual acuity of 20/40 or better. Filler or plugs were instilled bilaterally in the inferior canaliculi. Primary effectiveness endpoint was non-inferiority of the mean within subject change from baseline to Month 3 in Schirmer score for patients receiving filler compared to plugs. The key secondary effectiveness endpoint was non-inferiority of the proportion of patients with filler achieving improvement from baseline to Month 3 in OSDI by a minimal clinically important difference (MCID). Additional endpoints included the mean change from baseline to 3 and 6 months in tear meniscus height, OSDI, corneal staining, tear break-up time, and safety. RESULTS: 157 patients were randomized; 99 patients with crosslinked HA filler and 52 patients with hydrogel plugs completed the study. Filler was non-inferior to plugs in the mean Schirmer score change from baseline and in the proportion of patients achieving a clinically important improvement in OSDI. CONCLUSIONS: Crosslinked HA filler is a safe, well-tolerated, and effective method to treat dry eye. Clinically and statistically significant improvements in signs and symptoms of dry eye were sustained through 6 months.

3.
Clin Ther ; 46(2): 104-113, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38216351

RESUMO

PURPOSE: This study was undertaken to evaluate the safety and efficacy of CSF-1 (0.4% pilocarpine hydrochloride ophthalmic solution) for use in individuals with presbyopia. METHODS: Two Phase 3 multicenter, randomized, double-masked, vehicle-controlled, parallel-group clinical trials were conducted in 35 private ophthalmology clinics in the United States from October 2020 to February 2022. Key inclusion criteria were the following: (1) age 45-64 years, (2) distance-corrected near visual acuity (DCNVA) at 40 cm ≥0.40 and ≤0.90 logarithm of the minimum angle of resolution (logMAR, approximately 20/50-20/160 Snellen) in at least 1 eye, (3) manifest refraction (MR) between -4.50 and +2.00 diopter (D) sphere in each eye with ≤2.00D difference between eyes, (4) <2.00D of cylinder MR in each eye, (5) ≤0.04 logMAR (20/20-2 or better) corrected distance visual acuity (CDVA) at 4 m in each eye. Key exclusion criteria were the following: (1) >0.14 logMAR (7 letters) improvement in post-vehicle treatment in monocular DCNVA in either eye at visit 1, (2) introcular pressure (IOP) <9 or >22 mm Hg, (3) average dark-adapted pupillometry <3.5 mm in either eye, (4) prior refractive surgery or intraocular lens (IOL) implantation. Participants applied CSF-1 or vehicle twice per day for 2 weeks. Efficacy and safety assessments were performed at several times on days 1, 8, and 15. Response was defined as ≥3-line gain in DCNVA without loss of ≥1-line in CDVA in the study eye under mesopic room lighting conditions. The primary efficacy endpoint was measured 1 hour post-dose 1 on day 8. Key secondary endpoints were 2 hours post-dose 1, and 1 and 2 hours post-dose 2, also on day 8. Safety endpoints were ocular and non-ocular treatment-related adverse events (TRAE), conjunctival redness, drop comfort, slit-lamp biomicroscopy, intraocular pressure, indirect fundoscopy, and CDVA at 4 m. FINDINGS: Six hundred thirteen participants were randomized to CSF-1 (n = 309) or vehicle (n = 304). Participants were predominantly White (80.8%) and female (62.0%), with mean age (standard deviation) of 54.7 (4.8). CSF-1 met the primary and key secondary endpoints. At the primary endpoint, 40.1% of the CSF-1 group achieved response versus 19.1% of the vehicle group (P < 0.0001). The percentage of responders was significantly greater in CSF-1 compared with vehicle at all tested times. Changes from baseline in all safety endpoints were comparable between groups. Most adverse events (AEs) were mild and transient. Neither serious nor severe AEs were reported with CSF-1. IMPLICATIONS: CSF-1, a low-dose pilocarpine ophthalmic solution, demonstrated superiority to vehicle in improving near vision in individuals with presbyopia without compromising distance vision. CSF-1 demonstrated a favorable safety profile. CLINICALTRIALS: gov identifier: NCT04599933 (NEAR-1), NCT04599972 (NEAR-2).


Assuntos
Lentes Intraoculares , Presbiopia , Feminino , Humanos , Pessoa de Meia-Idade , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Fator Estimulador de Colônias de Macrófagos , Soluções Oftálmicas/efeitos adversos , Pilocarpina/efeitos adversos , Presbiopia/tratamento farmacológico , Presbiopia/complicações
4.
Curr Opin Ophthalmol ; 24(4): 281-7, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23703461

RESUMO

PURPOSE OF REVIEW: This study provides an overview of the three types of corneal inlays now in use for the correction of presbyopia and reviews recently published evidence of the inlays' safety and efficacy. RECENT FINDINGS: Results for corneal reshaping and refractive inlays are promising, but very limited. Small-aperture inlays are already in widespread use and have been shown to improve uncorrected near and intermediate vision without a significant loss in distance acuity or an unacceptable increase in visual symptoms. Complications have been minimal, but the inlays may be removed if necessary. They do not prevent visualization or imaging of the retina and may be retained during subsequent cataract surgery. SUMMARY: The presbyopic demographic is large and growing, with a high level of interest in spectacle independence. There is currently no other effective solutions for presbyopes who desire good uncorrected vision at all distances without the risks of intraocular surgery or the visual compromises of monovision. Additional research is needed, but the future for corneal inlay technology is bright.


Assuntos
Substância Própria/cirurgia , Presbiopia/cirurgia , Próteses e Implantes , Substância Própria/fisiopatologia , Humanos , Procedimentos Cirúrgicos Oftalmológicos , Presbiopia/fisiopatologia , Implantação de Prótese , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
5.
Clin Ophthalmol ; 17: 2219-2230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37564159

RESUMO

Purpose: To compare the preservative-free corticosteroid 0.2% betamethasone sodium phosphate BID (SURF-201) to vehicle BID in patients undergoing routine cataract surgery. Methods: Phase 2, multicenter, randomized (1:1 ratio), double-masked, vehicle-controlled, parallel-group study in patients scheduled for uncomplicated cataract surgery without the aid of a femtosecond laser. Subjects instilled topical medications for 16 days beginning the day before cataract surgery (Day -1), 1 dose administered at least 1 hour prior to cataract surgery (on Day 0) and 1 dose on the evening after cataract surgery, and then 2 doses administered each day through Day 15; patients were re-evaluated on Days 22 and 32 to ensure no rebound inflammation. Primary outcome was the difference in the proportion of subjects with anterior chamber cell (ACC) grade 0 between the two groups at Day 15. Secondary outcomes included pain scores and overall safety. Results: There was a statistically significant difference (P=0.004) in the proportion of subjects in the SURF-201 treatment group with an ACC grade of 0 at Day 15 (n=22/39 [56.4%]) compared to subjects in the vehicle treatment group (n=9/43 [20.9%]). There was no statistically significant difference (P=0.528) in the proportion of subjects in the SURF-201 treatment group who had a visual analog scale pain score of 0 at Day 15 (n=35/38 [89.7%]) compared to subjects in the vehicle group (n=33/40 [82.5%]). A slightly higher incidence of adverse events occurred in subjects in the SURF-201 treatment group (n=27/40 [67.5%]) compared to the vehicle treatment group (n=23/43 [53.5%]). Conclusion: SURF-201 is an effective topical, preservative-free corticosteroid when dosed BID for the treatment of postoperative inflammation and prevention of pain in a post-cataract population.

6.
Br J Ophthalmol ; 107(1): 62-65, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34433548

RESUMO

INTRODUCTION: Laser trabeculoplasty is an effective and widely used treatment for glaucoma. A new laser technology, the Eagle direct selective laser trabeculoplasty (DSLT) device, may provide automated, fast, simple, safe and effective laser treatment for glaucoma in a broader range of clinical settings. This trial aims to test the hypothesis that translimbal DSLT is effective and not inferior to selective laser trabeculoplasty (SLT) in reducing intraocular pressure (IOP) in open angle glaucoma (OAG). METHODS AND ANALYSIS: This is a multicentre, randomised, controlled, investigator-masked study. The primary efficacy outcome is intergroup difference in mean change from baseline IOP measured at 6 months. Secondary outcomes include mean percentage reduction in IOP at 3, 6 and 12 months; proportion of participants with at least 20% reduction in IOP from baseline at 6 months; change in ocular hypotensive medications at 12 months and evaluation of safety. Participants were aged >= 40 years with OAG, including exfoliative or pigmentary glaucoma, or ocular hypertension with untreated or washed out IOP 22-35 mm Hg. TREATMENTS: DSLT: 120 shots, 3 ns, 400 µm spot size, energy 1.4-1.8 mJ delivered at the limbus over 2 s. SLT: approximately 100 shots, 3 ns, 400 µm spot size administered 360 degrees at the limbus using any gonioscopy lens, energy 0.3-2.6 mJ. A sample size of 164 is sufficient to detect a non-inferiority margin of 1.95 mm Hg for change from baseline IOP. CLINICAL TRIAL REGISTRATION NUMBER: NCT03750201, ISRCTN14033075.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Trabeculectomia , Humanos , Trabeculectomia/métodos , Pressão Intraocular , Terapia a Laser/métodos , Glaucoma/cirurgia , Resultado do Tratamento
7.
Eye (Lond) ; 37(15): 3249-3255, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36964261

RESUMO

BACKGROUND: Twelve ocular surface disease experts convened to achieve consensus about Demodex blepharitis (DB) using a modified Delphi panel process. METHODS: Online surveys were administered using scaled, open-ended, true/false, and multiple-choice questions. Consensus for questions using a 1 to 9 Likert scale was predefined as median scores of 7-9 and 1-3. For other question types, consensus was achieved when 8 of 12 panellists agreed. Questions were randomized, and results of each survey informed the following survey. RESULTS: Twelve practitioners comprised the Demodex Expert Panel on Treatment and Eyelid Health (DEPTH). Following 3 surveys, experts agreed that DB is chronic (n = 11) and recurrent (n = 12) and is often misdiagnosed. Consensus was achieved regarding inflammation driving symptoms (median = 7; range 7-9), collarettes as the most common sign (n = 10) and pathognomonic for DB (median = 9; range 8-9), and itching as the most common symptom (n = 12). Panellists agreed that DB may be diagnosed based on collarettes, mites, and/or patient symptoms (n = 10) and felt that patients unresponsive to typical therapies should be evaluated for DB (n = 12). Consensus about the most effective currently available OTC treatment was not reached. CONCLUSIONS: The Delphi methodology proved effective in establishing consensus about DB, including signs, symptoms, and diagnosis. Consensus was not reached about the best treatment or how to grade severity. With increased awareness, eyecare practitioners can offer DB patients better clinical outcomes. A follow-up Delphi panel is planned to obtain further consensus surrounding DB treatment.

8.
Clin Ophthalmol ; 17: 667-679, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36875531

RESUMO

Purpose: To obtain consensus on Demodex blepharitis (DB) treatment using a modified Delphi panel process. Methods: Literature search identified gaps in knowledge surrounding treatment of DB. Twelve ocular surface disease experts comprised the Demodex Expert Panel on Treatment and Eyelid Health (DEPTH). They completed a live roundtable discussion in addition to 3 surveys consisting of scaled, open-ended, true/false, and multiple-choice questions pertaining to the treatment of DB. Consensus for scaled questions using a 1 to 9 Likert scale was predefined as median scores of 7-9 and 1-3. For other question types, consensus was achieved when 8 of 12 panelists agreed. Results: The experts agreed that an effective therapeutic agent for treatment of DB would likely decrease the necessity of mechanical intervention, such as lid scrubs or blepharoexfoliation (Median = 8.5; Range 2-9). When treating DB, panelists believed that collarettes serve as a surrogate for mites, and that eliminating or reducing collarettes should be the main clinical goal of treatment (Median = 8; Range 7-9). The panelists would treat patients with at least 10 collarettes, regardless of other signs or symptoms and agreed that DB can be cured, but there is always the possibility for a reinfestation (n = 12). There was also consensus that collarettes, and therefore mites, are the primary treatment target and the way by which clinicians can monitor patient response to therapy (Median = 8; Range 7-9). Conclusion: Expert panelists achieved consensus on key facets of DB treatment. Specifically, there was consensus that collarettes are pathognomonic for DB, that DB patients with >10 collarettes should be treated even in the absence of symptoms, and that treatment efficacy can be tracked by collarette resolution. By increasing awareness about DB, understanding the goals of and monitoring treatment efficacy, patients will receive better care and, ultimately, better clinical outcomes.

9.
J Ocul Pharmacol Ther ; 38(10): 657-663, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36327101

RESUMO

Background: This phase 2 study evaluated the therapeutic potential of netarsudil to reduce corneal edema and to improve vision in patients with Fuchs corneal dystrophy (FCD). Methods: Patients (N = 40) with baseline central corneal thickness (CCT) of ≥600 µm and best-corrected visual acuity (BCVA) of 70-20 letters (20/40-20/400 Snellen equivalent) were randomized 1:1 to receive netarsudil once a day (QD) or twice a day (BID) for 8 weeks. Primary endpoint was mean CCT change from baseline at week 4. Results: Netarsudil QD and BID significantly reduced CCT at week 4 [mean change (standard error of mean), 28.4 (7.99) µm, P = 0.0021; and 20.1 (8.75) µm, P = 0.0335, respectively]. Five (12.5%) patients achieved complete resolution of corneal edema at week 4. BCVA improved by 3.2 (2.76) letters with QD and 1.5 (2.84) letters with BID, and 10 (25%) patients [5 with QD (P = 0.0078) and 5 with BID (P = 0.0096)] gained ≥10 letters at week 4. Improvements in CCT and vision were observed at week 2 and persisted at week 8, without significant differences between the 2 doses at any time point. Netarsudil QD significantly improved visual acuity and glare factor scores on the Visual Function and Corneal Health Status (V-FUCHS) questionnaire at weeks 4 and 8 (mean change, -0.4 to -0.3; P ≤ 0.0200). Netarsudil was well tolerated. Reticular edema developed in one (2.5%) patient with BID, which resolved with treatment discontinuation. Conclusions: Netarsudil QD led to significant reductions in corneal edema as well as improvements in vision and patient-reported symptoms of glare and visual impairment in patients with FCD. Clinical Trial Registration Number: NCT04498169.


Assuntos
Edema da Córnea , Distrofia Endotelial de Fuchs , Humanos , Edema da Córnea/tratamento farmacológico
10.
J Glaucoma ; 31(8): e49-e68, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35701875

RESUMO

PRCIS: A literature review of selective laser trabeculoplasty (SLT) energy dose-response found no definitive relationship between intraocular pressure (IOP) reduction with respect to total or pulse energy, race, pigmentation, or application pattern. PURPOSE: SLT is a safe and effective treatment for lowering IOP. Although evidence is mounting for the advantage of its use as a first-line treatment for IOP reduction, the SLT procedures in use vary widely. The purpose of this literature review was to investigate whether there were any relationships between SLT energy and efficacy for lowering IOP in the published literature. METHODS: A literature review was undertaken that included studies in which energy levels required for successful SLT treatment were investigated: in general, with respect to angle pigmentation, race or ethnicity, and treatment arc extent. RESULTS: There was no indication that higher (or lower) energy used in the treatment leads to greater (or less) IOP reduction. Similar results were obtained regarding the level of trabecular meshwork pigmentation. Race was not found to be associated with altered dose response in SLT. There were indications that treating the full 360 degrees, as opposed to smaller arcs, could be beneficial for more IOP reduction. IOP reduction from SLT was found to be similar to that provided by topical medications. CONCLUSIONS: The optimal energy level of SLT needed for IOP reduction has not yet been definitively established, with all reported pulse energies resulting in similar IOP reduction. Furthermore, similar lack of conclusive findings exists regarding optimal SLT energy dosage for use in different races and degrees of trabecular meshwork pigmentation. This parameter and each of the abovementioned factors requires further research.


Assuntos
Glaucoma de Ângulo Aberto , Terapia a Laser , Hipotensão Ocular , Trabeculectomia , Glaucoma de Ângulo Aberto/tratamento farmacológico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Terapia a Laser/métodos , Lasers , Hipotensão Ocular/cirurgia , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Resultado do Tratamento
11.
Anal Chem ; 83(9): 3493-8, 2011 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21466194

RESUMO

An accurate and precise measurement of selenium in Standard Reference Material (SRM) 3149, a primary calibration standard for the quantitative determination of selenium, has been accomplished by instrumental neutron activation analysis (INAA) in order to resolve a question arising during the certification process of the standard. Each limiting factor of the uncertainty in the activation analysis, including the sample preparation, irradiation, and γ-ray spectrometry steps, has been carefully monitored to minimize the uncertainty in the determined mass fraction. Neutron and γ-ray self-shielding within the elemental selenium INAA standards contributed most significantly to the uncertainty of the measurement. An empirical model compensating for neutron self-shielding and reducing the self-shielding uncertainty was successfully applied to these selenium standards. The mass fraction of selenium in the new lot of SRM 3149 was determined with a relative standard uncertainty of 0.6%.


Assuntos
Nêutrons , Radioquímica/instrumentação , Selênio/análise , Calibragem , Modelos Lineares , Radioquímica/normas , Padrões de Referência , Incerteza
12.
J Med Econ ; 24(1): 410-420, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33210975

RESUMO

AIMS: To assess the cost-effectiveness of corneal collagen cross-linking (CXL) versus no CXL for keratoconus in the United States (US). METHODS: A discrete-event microsimulation was developed to assess the cost-effectiveness of corneal cross-linking (CXL, Photrexa + KXL combination product) versus no CXL for patients with keratoconus. The lifetime model was conducted from a US payor perspective. The source for CXL efficacy and safety data was a 12-month randomized, open-label, sham-controlled, multi-center, pivotal trial comparing CXL versus no CXL. Other inputs were sourced from the literature. The primary outcome was the incremental cost per quality-adjusted life year gained. Costs (2019 USD) and effects were discounted 3% annually. The impacts of underlying uncertainty were evaluated by scenario, univariate, and probabilistic analyses. RESULTS: Starting at a mean baseline age of 31 years and considering a mixed population consisting of 80% slow-progressors and 20% fast-progressors, the CXL group was 25.9% less likely to undergo penetrating keratoplasty (PK) and spent 27.9 fewer years in advanced disease stages. CXL was dominant with lower total direct medical costs (-$8,677; $30,994 versus $39,671) and more QALYs (1.88; 21.80 versus 19.93) compared to no CXL. Considering the impact of reduced productivity loss in an exploratory scenario, CXL was associated with a lifetime cost-savings of $43,759 per patient. CXL was cost-effective within 2 years and cost-saving within 4.5 years. LIMITATIONS: Limitations include those that are common to similar pharmacoeconomic models that rely on disparate sources for inputs and extrapolation on short-term outcomes to a long-term analytical horizon. CONCLUSIONS: Keratoconus is a progressive and life-altering disease with substantial clinical, economic, and humanistic consequences. The economic value of cross-linking is maximized when applied earlier in the disease process and/or younger age, and extends to improved work productivity, out-of-pocket costs, and quality of life.


Assuntos
Ceratocone , Fotoquimioterapia , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Seguimentos , Humanos , Recém-Nascido , Ceratocone/tratamento farmacológico , Modelos Econômicos , Fármacos Fotossensibilizantes/uso terapêutico , Qualidade de Vida , Riboflavina/uso terapêutico , Raios Ultravioleta
13.
J AOAC Int ; 93(4): 1262-74, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20922961

RESUMO

Standard Reference Material (SRM) 1849 Infant/Adult Nutritional Formula has been issued by the National Institute of Standards and Technology (NIST) as a replacement for SRM 1846 Infant Formula, issued in 1996. Extraction characteristics of SRM 1846 have changed over time, as have NIST's analytical capabilities. While certified mass fraction values were provided for five constituents in SRM 1846 (four vitamins plus iodine), certified mass fraction values for 43 constituents are provided in SRM 1849 (fatty acids, elements, and vitamins) and reference mass fraction values are provided for an additional 43 constituents including amino acids and nucleotides, making it the most extensively characterized food-matrix SRM available from NIST.


Assuntos
Fórmulas Infantis/normas , Aminoácidos/análise , Comportamento Cooperativo , Ácidos Graxos/análise , Humanos , Lactente , Fórmulas Infantis/química , Padrões de Referência , Vitaminas/análise
14.
Clin Ophthalmol ; 14: 71-80, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32021070

RESUMO

INTRODUCTION: This study evaluated long-term reductions in intraocular pressure (IOP) and medication following implantation of 2 second-generation trabecular micro-bypass stents (iStent inject®) in eyes with open-angle glaucoma (OAG) not controlled on 1 preoperative medication. MATERIAL AND METHODS: In this prospective interventional multi-surgeon study, standalone implantation of 2 iStent inject stents was performed in 57 eyes of 57 subjects with OAG, preoperative IOP of 18-30 mmHg on 1 medication, and preoperative post-washout IOP of 22-38 mmHg. The main outcome measures included the proportions of eyes achieving medication-free IOP ≤18 mmHg, IOP ≤15 mmHg, or ≥20% IOP reduction versus preoperative unmedicated IOP. Assessments included IOP, medications, visual acuity, visual field, pachymetry, complications, and interventions. Subjects were followed for 48 months with follow-up continuing in all eyes. RESULTS: At Month 48 (n=57), 95% of eyes achieved an IOP reduction of ≥20% without medication versus preoperative washout IOP; and although they had eliminated medication, 81% of eyes still had an IOP reduction of ≥20% versus preoperative IOP on 1 medication. Mean 48-month unmedicated IOP decreased by 46% to 13.2±1.6 mmHg vs 24.4±1.3 mmHg preoperatively (p<0.0001), with 95% of medication-free eyes having IOP ≤18mmHg and 82% having IOP ≤15mmHg. Over the course of follow-up, 3 eyes had medication added and 1 eye underwent a secondary glaucoma surgery, and safety parameters were favorable. DISCUSSION: Standalone iStent inject implantation in OAG patients on 1 preoperative medication resulted in average IOP reduction to ≤15 mmHg with the elimination of medication and favorable safety through 48 months. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT02868190.

15.
Clin Ophthalmol ; 14: 2739-2746, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33061256

RESUMO

PURPOSE: To investigate the safety and tolerability of the multi-pressure dial (MPD) worn overnight for seven consecutive days. DESIGN: Prospective, open-label, randomized, single-site study. SUBJECTS: Twenty eyes of 10 subjects with open-angle glaucoma were fitted with an MPD and randomized to negative pressure application of -10 mmHg in one eye (study eye) worn overnight for 7 consecutive days. METHODS: Safety measures included best-corrected visual acuity (BCVA), intraocular pressure (IOP) changes from baseline during and after negative pressure application, slit lamp and dilated fundus exam findings, and rate of adverse events. Subjective assessments were completed daily by the subjects during the 7-day study period and immediately following the study period. RESULTS: Prior to the 7-day testing period, application of 10 mmHg negative pressure reduced mean IOP from 18.2 ± 3.8 mmHg to 14.0 ± 2.1 mmHg (p<0.01), a 22% reduction. After 7 days of consecutive nightly wear, repeat IOP measurements with the application of negative pressure showed a decrease in mean IOP from 16.9 ± 4.3 mmHg to 13.5 ± 3.7 mmHg. The observed IOP reduction was in addition to the subjects' current treatment regimen. There were no statistically significant changes in IOP, BCVA from baseline following the 7-day period of nightly wear with the application of negative pressure. The patient-reported outcomes were favorable. CONCLUSION: The MPD can safely and comfortably be worn overnight. The decrease in IOP of >20% in addition to current therapy is both clinically and statistically significant. The MPD shows promise as a potential new treatment option for nocturnal IOP control.

16.
Transl Vis Sci Technol ; 9(12): 19, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33240572

RESUMO

Purpose: To evaluate the intraocular pressure (IOP)-lowering effect of a multi-pressure dial (MPD) at targeted negative pressure settings. Methods: Prospective, intrasubject controlled study of 65 healthy subjects randomized to receive no negative pressure for 60 minutes or negative pressure application at designated levels of 25%, 50%, and 75% of baseline IOP for 20 minutes each. The main outcome measure was mean IOP with application of negative pressure. Results: In the study eye group, from a baseline IOP of 15.8 ± 3.6 mm Hg, the mean IOP was 13.5 ± 3.4, 11.5 ± 3.1, and 10.2 ± 2.7 mm Hg with negative pressure settings of 25%, 50% and 75%, respectively. In the control eye group, from a baseline IOP of 15.5 ± 3.0 mm Hg, the mean IOP values at the same time points, without negative pressure, were 15.6 ± 3.0, 15.5 ± 2.5 and 15.3 ± 2.4 mm Hg. The difference between the mean IOPs of the two groups was significantly different at all negative pressure settings (P < 0.001) in comparison with baseline. There was one minor adverse event, a corneal abrasion, that was unrelated to device wear. Conclusions: Negative pressure application to the periocular space with a multi-pressure dial can produce titratable IOP reduction while the device is worn with active negative pressure. To our knowledge, this technology represents the first nonpharmacologic, nonlaser, nonsurgical method for IOP reduction. Translational Relevance: This represents the first study demonstrating the IOP-lowering ability of the multi-pressure dial, a device that uses a novel IOP-lowering strategy by delivering negative pressure to the periocular region.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Anti-Hipertensivos/uso terapêutico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Humanos , Estudos Prospectivos , Tonometria Ocular
17.
Ophthalmic Surg Lasers Imaging Retina ; 51(11): 633-639, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33231696

RESUMO

BACKGROUND AND OBJECTIVE: Clinical trials in neovascular age-related macular degeneration (nAMD) demonstrate that high visual acuity (VA) can be maintained, and low VA can be improved with anti-vascular endothelial growth factor (VEGF) treatment. Few real-world data investigating the relationship between baseline VA and long-term outcomes exist. This study compares VA at diagnosis and after treatment using data from a large patient registry. PATIENTS AND METHODS: Retrospective study of IRIS Registry patients diagnosed with nAMD in one or both eyes between January 2013 and June 2017. Patients received at least two anti-VEGF injections in the study eye(s) less than 45 days apart during the study period. Primary outcomes were the percentage of eyes with 20/40 VA or better at diagnosis and association of VA at diagnosis with longer-term visual outcomes. RESULTS: The study included 162,902 eyes. Among all included eyes, 34.3% presented with 20/40 VA or better at diagnosis. Patients with 20/40 vision or better at baseline maintained a mean VA of 20/40 or better for 2 years after treatment initiation. CONCLUSIONS: Baseline VA at nAMD diagnosis predicts long-term VA outcomes. Early diagnosis before VA is adversely affected is a key factor in preserving vision in patients with nAMD. [Ophthalmic Surg Lasers Imaging Retina. 2020;51:633-639.].


Assuntos
Ranibizumab , Acuidade Visual , Degeneração Macular Exsudativa , Inibidores da Angiogênese/uso terapêutico , Seguimentos , Humanos , Injeções Intravítreas , Ranibizumab/uso terapêutico , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/tratamento farmacológico
18.
Ophthalmology ; 116(4): 691-701, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19344821

RESUMO

PURPOSE: To analyze the patient reported outcome of satisfaction after LASIK surgery. DESIGN: Systematic review. PARTICIPANTS: Patient data from previously reported studies. METHODS: A literature search conducted for the years 1988 to 2008 that included pertinent LASIK surgery information from the review of 2915 retrieved citations. All abstracts from these citations were reviewed and 1581 were deemed to be relevant for review. Complete copies of each of these relevant (1581) articles were obtained, and after thorough analysis each was rated based on the strength of the study design and weight of evidence. A level I rating was assigned to properly conducted, well-designed, randomized clinical trials; a level II rating to well-designed cohort and case-control studies; and a level III rating to case series, case reports, and poorly designed prospective and retrospective studies. Level I and II rated, peer-reviewed articles were entered into a database, and level III articles were eliminated. A total of 309 articles were incorporated into this database, representing level I and level II well-controlled studies of primary LASIK surgery. MAIN OUTCOME MEASURES: Patients' satisfaction rates and factors associated with dissatisfaction. RESULTS: Nineteen of the 309 database articles (6.1%) reported on both patient quality of life and satisfaction and together encompassed a total of 2198 subjects. The procedures from these 19 articles took place between 1995 and 2003. The overall patient satisfaction rate after primary LASIK surgery was 95.4% (2097 of 2198 subjects; range of patient satisfaction for the 19 articles was 87.2%-100%). The patient satisfaction rate after myopic LASIK was 95.3% (1811 of 1901 patients), and after hyperopic LASIK was 96.3% (286 of 297 subjects). CONCLUSIONS: Based on this review, worldwide, an average 95.4% of patients were satisfied with their outcome after LASIK surgery. With 16.3 million procedures performed worldwide, and more than a decade of clinical studies and technological innovation, LASIK surgery should be considered among the most successful elective procedures. LASIK surgery compares more favorably with other elective surgical procedures in terms of generally higher satisfaction rates.


Assuntos
Hiperopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia/cirurgia , Satisfação do Paciente/estatística & dados numéricos , Qualidade de Vida , Adolescente , Adulto , Idoso , Bibliometria , Saúde Global , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Am J Ophthalmol ; 203: 78-88, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30849341

RESUMO

PURPOSE: To examine the association of donor, recipient, and operative factors on graft dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK) in the Cornea Preservation Time Study (CPTS) as well as the effects of graft dislocation and elevated IOP on graft success and endothelial cell density (ECD) 3 years postoperatively. DESIGN: Cohort study within a multi-center, double-masked, randomized clinical trial. METHODS: 1090 individuals (1330 study eyes), median age 70 years, undergoing DSAEK for Fuchs endothelial corneal dystrophy (94% of eyes) or pseudophakic or aphakic corneal edema (6% of eyes). Recipient eyes receiving donor corneal tissue randomized by preservation time (PT) of 0-7 days (N = 675) or 8-14 days (N = 655) were monitored for early or late graft failure through 3 years. Donor, recipient, operative, and postoperative parameters were recorded including graft dislocation (GD), partial detachment, and pre- and post-operative IOP. Pre- and postoperative central donor ECD were determined by a central image analysis reading center. Proportional hazards, mixed effects, and logistic regression models estimated risk ratios and (99% confidence intervals). RESULTS: Three independent predictive factors for GD were identified: a history of donor diabetes (odds ratio [OR]: 2.29 [1.30, 4.02]), increased pre-lamellar dissection central corneal thickness (OR: 1.13 [1.01, 1.27] per 25µ increase), and operative complications (OR: 2.97 [1.24, 7.11]). Among 104 (8%) eyes with GD, 30 (28.9%) developed primary donor or early failure and 5 (4.8%) developed late failure vs. 15 (1.2%; P < .001) and 29 (2.4%; P = .04), respectively, of 1226 eyes without GD. 24 (2%) of 1330 study eyes had early acutely elevated postoperative IOP that was associated with a higher risk of graft failure through 3 years (hazard ratio: 3.42 [1.01, 11.53]), but not with a lower mean 3-year ECD (mean difference 61 (-479, 601) cells/mm2, P = .77). History of elevated postoperative IOP beyond 1 month was not significantly associated with 3-year graft success or ECD. CONCLUSIONS: Donor diabetes, increased donor corneal thickness, and intraoperative complications were associated with an increased risk of GD. Early acutely elevated postoperative IOP and GD significantly increased the risk for graft failure following DSAEK.


Assuntos
Córnea/patologia , Edema da Córnea/cirurgia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Distrofia Endotelial de Fuchs/cirurgia , Rejeição de Enxerto/prevenção & controle , Pressão Intraocular/fisiologia , Preservação de Órgãos/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Contagem de Células , Edema da Córnea/diagnóstico , Método Duplo-Cego , Feminino , Seguimentos , Distrofia Endotelial de Fuchs/diagnóstico , Rejeição de Enxerto/diagnóstico , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA