Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 208(9): 917-929, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37703083

RESUMO

Rationale: Clinical trials have shown that use of elexacaftor/tezacaftor/ivacaftor (ETI) is associated with improvements in sweat chloride, pulmonary function, nutrition, and quality of life in people with cystic fibrosis (CF). Little is known about the impact of ETI on ventilation inhomogeneity and lung structure. Objectives: RECOVER is a real-world study designed to measure the impact of ETI in people with CF. The primary endpoints were lung clearance (lung clearance index; LCI2.5) and FEV1. Secondary endpoints included spirometry-controlled chest computed tomography (CT) scores. Methods: The study was conducted in seven sites in Ireland and the United Kingdom. Participants ages 12 years and older who were homozygous for the F508del mutation (F508del/F508del) or heterozygous for F508del and a minimum-function mutation (F508del/MF) were recruited before starting ETI and were followed up over 12 months. LCI2.5 was measured using nitrogen multiple breath washout (MBW) at baseline and at 6 and 12 months. Spirometry was performed as per the criteria of the American Thoracic Society and the European Respiratory Society. Spirometry-controlled chest CT scans were performed at baseline and at 12 months. CT scans were scored using the Perth Rotterdam Annotated Grid Morphometric Analysis (PRAGMA) system. Other outcome measures include weight, height, Cystic Fibrosis Quality of Life Questionnaire-Revised (CFQ-R), and sweat chloride. Measurements and Main Results: One hundred seventeen people with CF ages 12 and older were recruited to the study. Significant improvements were seen in LCI scores (-2.5; 95% confidence interval [CI], -3.0, -2.0) and in the percents predicted for FEV1 (8.9; 95% CI, 7.0, 10.9), FVC (6.6; 95% CI, 4.9, 8.3), and forced expiratory flow between 25% and 75% of expired volume (12.4; 95% CI, 7.8, 17.0). Overall PRAGMA-CF scores reflecting airway disease improved significantly (-3.46; 95% CI, -5.23, -1.69). Scores for trapped air, mucus plugging, and bronchial wall thickening improved significantly, but bronchiectasis scores did not. Sweat chloride levels decreased in both F508del/F508del (-43.1; 95% CI, -47.4, -38.9) and F508del/MF (-42.8; 95% CI, -48.5, -37.2) groups. Scores on the Respiratory Domain of the CFQ-R improved by 14.2 points (95% CI, 11.3, 17.2). At 1 year, sweat chloride levels were significantly lower for the F508del/F508del group compared with scores for the F508del/MF group (33.93 vs. 53.36, P < 0.001). Conclusions: ETI is associated with substantial improvements in LCI2.5, spirometry, and PRAGMA-CF CT scores in people with CF ages 12 years and older. ETI led to improved nutrition and quality of life. People in the F508del/F508del group had significantly lower sweat chloride on ETI treatment compared with the F508del/MF group. Clinical trial registered with www.clinicaltrials.gov (NCT04602468).


Assuntos
Fibrose Cística , Humanos , Aminofenóis/uso terapêutico , Benzodioxóis/uso terapêutico , Agonistas dos Canais de Cloreto/uso terapêutico , Cloretos/análise , Fibrose Cística/diagnóstico por imagem , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/uso terapêutico , Pulmão , Mutação , Qualidade de Vida , Tomografia Computadorizada por Raios X
2.
Respir Res ; 24(1): 199, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37568199

RESUMO

BACKGROUND: Data from clinical trials of lumacaftor-ivacaftor (LUM-IVA) demonstrate improvements in lung clearance index (LCI) but not in FEV1 in children with Cystic Fibrosis (CF) aged 6-11 years and homozygous for the Phe508del mutation. It is not known whether LUM/IVA use in children can impact the progression of structural lung disease. We sought to determine the real-world impact of LUM/IVA on lung structure and function in children aged 6-11 years. METHODS: This real-world observational cohort study was conducted across four paediatric sites in Ireland over 24-months using spirometry-controlled CT scores and LCI as primary outcome measures. Children commencing LUM-/IVA as part of routine care were included. CT scans were manually scored with the PRAGMA CF scoring system and analysed using the automated bronchus-artery (BA) method. Secondary outcome measures included rate of change of ppFEV1, nutritional indices and exacerbations requiring hospitalisation. RESULTS: Seventy-one participants were recruited to the study, 31 of whom had spirometry-controlled CT performed at baseline, and after one year and two years of LUM/IVA treatment. At two years there was a reduction from baseline in trapped air scores (0.13 to 0.07, p = 0.016), but an increase from baseline in the % bronchiectasis score (0.84 to 1.23, p = 0.007). There was no change in overall % disease score (2.78 to 2.25, p = 0.138). Airway lumen to pulmonary artery ratios (AlumenA ratio) were abnormal at baseline and worsened over the course of the study. In 28 participants, the mean annual change from baseline LCI2.5 (-0.055 (-0.61 to 0.50), p = 0.85) measurements over two years were not significant. Improvements from baseline in weight (0.10 (0.06 to 0.15, p < 0.0001), height (0.05 (0.02 to 0.09), p = 0.002) and BMI (0.09 (0.03 to 0.15) p = 0.005) z-scores were seen with LUM/IVA treatment. The mean annual change from baseline ppFEV1 (-2.45 (-4.44 to 2.54), p = 0.66) measurements over two years were not significant. CONCLUSION: In a real-world setting, the use of LUM/IVA over two years in children with CF aged 6-11 resulted in improvements in air trapping on CT but worsening in bronchiectasis scores. Our results suggest that LUM/IVA use in this age group improves air trapping but does not prevent progression of bronchiectasis over two years of treatment.


Assuntos
Bronquiectasia , Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Aminopiridinas/uso terapêutico , Pulmão/diagnóstico por imagem , Combinação de Medicamentos , Mutação
3.
Mol Ther ; 28(4): 1190-1199, 2020 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-32059764

RESUMO

MicroRNAs that are overexpressed in cystic fibrosis (CF) bronchial epithelial cells (BEC) negatively regulate CFTR and nullify the beneficial effects of CFTR modulators. We hypothesized that it is possible to reverse microRNA-mediated inhibition of CFTR using CFTR-specific target site blockers (TSBs) and to develop a drug-device combination inhalation therapy for CF. Lead microRNA expression was quantified in a series of human CF and non-CF samples and in vitro models. A panel of CFTR 3' untranslated region (UTR)-specific locked nucleic acid antisense oligonucleotide TSBs was assessed for their ability to increase CFTR expression. Their effects on CFTR activity alone or in combination with CFTR modulators were measured in CF BEC models. TSB encapsulation in poly-lactic-co-glycolic acid (PLGA) nanoparticles was assessed as a proof of principle of delivery into CF BECs. TSBs targeting the CFTR 3' UTR 298-305:miR-145-5p or 166-173:miR-223-3p sites increased CFTR expression and anion channel activity and enhanced the effects of ivacaftor/lumacaftor or ivacaftor/tezacaftor in CF BECs. Biocompatible PLGA-TSB nanoparticles promoted CFTR expression in primary BECs and retained desirable biophysical characteristics following nebulization. Alone or in combination with CFTR modulators, aerosolized CFTR-targeting TSBs encapsulated in PLGA nanoparticles could represent a promising drug-device combination therapy for the treatment for CFTR dysfunction in the lung.


Assuntos
Brônquios/metabolismo , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Fibrose Cística/terapia , MicroRNAs/genética , Oligonucleotídeos/farmacologia , Adulto , Aminofenóis/farmacologia , Aminopiridinas/farmacologia , Benzodioxóis/farmacologia , Brônquios/citologia , Brônquios/efeitos dos fármacos , Células Cultivadas , Criança , Pré-Escolar , Fibrose Cística/genética , Fibrose Cística/metabolismo , Combinação de Medicamentos , Sinergismo Farmacológico , Células Epiteliais/citologia , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Feminino , Humanos , Indóis/farmacologia , Lactente , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Nanopartículas , Oligonucleotídeos/genética , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Quinolonas/farmacologia
4.
BMC Pulm Med ; 21(1): 158, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980186

RESUMO

BACKGROUND: Oscillating Positive Expiratory Pressure (OPEP) devices are important adjuncts to airway clearance therapy in patients with cystic fibrosis (CF). Current devices are typically reusable and require daily, or often more frequent, cleaning to prevent risk of infection by acting as reservoirs of potentially pathogenic organisms. In response, a daily disposable OPEP device, the UL-OPEP, was developed to mitigate the risk of contamination and eliminate the burdensome need for cleaning devices. METHODS: A convenience sample of 36 participants, all current OPEP device users, was recruited from a paediatric CF service. For one month, participants replaced their current OPEP device with a novel daily disposable device. Assessment included pre- and post-intervention lung function by spirometry, as well as Lung Clearance Index. Quality of life was assessed using the Cystic Fibrosis Questionnaire - Revised, while user experience was evaluated with a post-study survey. RESULTS: 31 participants completed the study: 18 males; median age 10 years, range 4-16 years. Lung function (mean difference ± SD, %FEV1 = 1.69 ± 11.93; %FVC = 0.58 ± 10.04; FEV1: FVC = 0.01 ± 0.09), LCI (mean difference ± SD, 0.08 ± 1.13), six-minute walk test, and CFQ-R were unchanged post-intervention. Participant-reported experiences of the device were predominantly positive. CONCLUSIONS: The disposable OPEP device maintained patients' lung function during short term use (≤ 1 month), and was the subject of positive feedback regarding functionality while reducing the risk of airway contamination associated with ineffective cleaning. REGISTRATION: The study was approved as a Clinical Investigation by the Irish Health Products Regulatory Authority (CRN-2209025-CI0085).


Assuntos
Oscilação da Parede Torácica/métodos , Fibrose Cística/terapia , Pulmão/fisiopatologia , Respiração com Pressão Positiva/métodos , Adolescente , Criança , Pré-Escolar , Estudos de Coortes , Fibrose Cística/fisiopatologia , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/patologia , Masculino , Depuração Mucociliar , Modalidades de Fisioterapia , Qualidade de Vida
5.
BMC Pulm Med ; 21(1): 326, 2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34666748

RESUMO

BACKGROUND: Handheld oscillating positive expiratory pressure (OPEP) devices have been a mainstay of treatment for patients with hypersecretory conditions such as cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD) since the 1970s. Current devices are reusable and require regular cleaning and disinfection to prevent harbouring potentially pathogenic organisms. Adherence to cleaning regimens for respiratory devices is often poor and in response to this, a prototype disposable OPEP device-the 'UL-OPEP' (University of Limerick-Oscillating Positive Expiratory Pressure device)-was developed to mitigate the risk of contamination by pathogens. The device was previously evaluated successfully in a group of paediatric CF patients. The aim of the current study was to initially evaluate the safety of the prototype in patients with COPD over a period of 1 month to ensure no adverse events, negative impacts on lung function, exercise tolerance, or quality of life. Data on user experience of the device were also collected during post-study follow-up. METHODS: A sample of 50 volunteer participants were recruited from pulmonary rehabilitation clinics within the local hospital network. The patients were clinically stable, productive, and not current or previous users of OPEP devices. Participants were invited to use a prototype disposable OPEP device daily for a period of 1 month. Pre- and post-study lung function was assessed with standard spirometry, and exercise tolerance with the 6-min-walk-test (6MWT). Quality of life was assessed using the St. George's Respiratory Questionnaire (SGRQ), and user experience of the prototype device evaluated using a post-study questionnaire. RESULTS: 24 Participants completed the study: 9 were female. Overall median age was 67.5 years, range 53-85 years. Lung function, 6-min walk test, and SGRQ scores showed no significant change post-study. User feedback was positive overall. CONCLUSIONS: The results indicate that the UL-OPEP is safe to use in patients with COPD. No adverse events were recorded during the study or in the follow-up period of 2 weeks. The device did not negatively impact patients' lung function, exercise tolerance, or quality of life during short term use (1 month), and usability feedback received was generally positive. Larger, longer duration studies will be required to evaluate efficacy. Registration The study was approved as a Clinical Investigation by the Irish Health Products Regulatory Authority (CRN-2209025-CI0085).


Assuntos
Oscilação da Parede Torácica/instrumentação , Oscilação da Parede Torácica/métodos , Doença Pulmonar Obstrutiva Crônica/terapia , Espirometria/instrumentação , Espirometria/métodos , Idoso , Idoso de 80 Anos ou mais , Oscilação da Parede Torácica/psicologia , Equipamentos Descartáveis , Feminino , Volume Expiratório Forçado , Humanos , Irlanda , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Projetos Piloto , Espirometria/psicologia , Inquéritos e Questionários
6.
Thorax ; 75(6): 449-458, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32265339

RESUMO

RATIONALE: Mutations in the cystic fibrosis transmembrane regulator (CFTR) gene form the basis of cystic fibrosis (CF). There remains an important knowledge gap in CF as to how diminished CFTR activity leads to the dominant inflammatory response within CF airways. OBJECTIVES: To investigate if extracellular vesicles (EVs) contribute to inflammatory signalling in CF. METHODS: EVs released from CFBE41o-, CuFi-5, 16HBE14o- and NuLi-1 cells were characterised by nanoparticle tracking analysis (NTA). EVs isolated from bronchoalveolar lavage fluid (BALF) from 30 people with CF (PWCF) were analysed by NTA and mass spectrometry and compared with controls. Neutrophils were isolated from the blood of 8 PWCF to examine neutrophil migration in the presence of CFBE41o- EVs. RESULTS: A significantly higher level of EVs were released from CFBE41o- (p<0.0001) and CuFi-5 (p=0.0209) relative to control cell lines. A significantly higher level of EVs were detected in BALF of PWCF, in three different age groups relative to controls (p=0.01, 0.001, 0.002). A significantly lower level of EVs were released from CFBE41o- (p<0.001) and CuFi-5 (p=0.0002) cell lines treated with CFTR modulators. Significant changes in the protein expression of 126 unique proteins was determined in EVs obtained from the BALF of PWCF of different age groups (p<0.001-0.05). A significant increase in chemotaxis of neutrophils derived from PWCF was observed in the presence of CFBE41o EVs (p=0.0024) compared with controls. CONCLUSION: This study demonstrates that EVs are produced in CF airway cells, have differential protein expression at different ages and drive neutrophil recruitment in CF.


Assuntos
Fibrose Cística/metabolismo , Vesículas Extracelulares/metabolismo , Adolescente , Adulto , Fatores Etários , Líquido da Lavagem Broncoalveolar/química , Linhagem Celular , Movimento Celular , Células Cultivadas , Quimiotaxia , Criança , Pré-Escolar , Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Feminino , Humanos , Lactente , Masculino , Espectrometria de Massas , Nanopartículas , Neutrófilos/metabolismo , Projetos Piloto , Transdução de Sinais , Transfecção
7.
Pediatr Res ; 88(4): 587-592, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32357363

RESUMO

BACKGROUND: Poorly performing diagnostic tests can impact patient safety. Clinical investigations must have good precision and diagnostic accuracy before widespread use in clinical practice. Transient elastography (TE) measures liver stiffness, a surrogate marker of liver fibrosis in adults and children. Studies to evaluate its repeatability and reproducibility (precision) in children are limited. Our aim was to determine (i) the normal range of TE measurements and (ii) the repeatability and reproducibility of TE in healthy children. METHODS: TE was performed in 257 healthy children, of whom 235 (91%, mean age 11.7 years, standard deviation (SD) 2.51, 107 were males (45.5%)) had two valid TE measurements performed, at least 24 h apart, by two operators under similar circumstances. High-quality TE images were obtained for each examination. RESULTS: The normal range of TE was 2.88-6.52 kPa. The mean difference between paired measurements was 0.044 (SD 0.4). The 95% limits of agreement ranged from -0.8 to +0.76 kPa for repeat measurements. There was a difference of >1 kPa between measurements in 61/235 (25.9%) children. The lack of precision was similar across all age groups. CONCLUSIONS: This study demonstrates that TE does not have acceptable precision in healthy children, because random measurement variation results in the lack of agreement between paired measurements. IMPACT: The precision and diagnostic accuracy of a new technology must be determined before it is deployed in children in order to ensure that appropriate clinical decisions are made, and healthcare resources are not wasted. TE is widely used to diagnose liver disease in children without adequate evaluation of the precision (repeatability) of TE either in healthy children or children with liver disease. This study demonstrates that TE does not have adequate precision in children. This study was performed in accordance with methods previously published for children. Refinements to the test protocol, such as duration of fasting or probe size, will have to be evaluated for their impact on precision and accuracy before the test is deployed in research studies or clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/fisiopatologia , Adolescente , Índice de Massa Corporal , Criança , Progressão da Doença , Feminino , Humanos , Fígado/fisiopatologia , Masculino , Pressão , Valores de Referência , Reprodutibilidade dos Testes , Resultado do Tratamento
8.
Semin Respir Crit Care Med ; 40(6): 701-714, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31679154

RESUMO

The diagnosis of cystic fibrosis (CF) has traditionally relied on the presence of clinical features of the disease. Today, diagnosis through newborn screening (NBS) is becoming the standard of modern CF care. CF NBS programs can identify CF prior to clinical presentation, but for the advantages of an early diagnosis to accrue a scrupulous system must be in place to ensure all steps in the program are performing. As we move rapidly into the era of CF transmembrane conductance regulator (CFTR) protein modulators, the opportunity to start a presymptomatic infant, identified through CF NBS, on these agents offers the prospect of true disease-modifying interventions which could result in a paradigm shift in CF care.Conversely, the introduction of NBS has resulted in many children being asymptomatic at the time of diagnosis. Some screened newborns are classified as "CF Screening Positive, Inconclusive Diagnosis", or "CFTR-related metabolic syndrome" when the diagnosis can neither be confirmed nor excluded. Appropriate assessment and follow-up should be arranged at specialist centers as a proportion of these infants and adults will eventually be diagnosed with CF.Symptoms and signs are particularly pertinent when considering a diagnosis of CF outside the context of NBS. In older patients with a late diagnosis, the spectrum of clinical presentation can be very variable with vigilant clinicians from multiple specialties suspecting the diagnosis in conditions such as recurrent pulmonary infections, male infertility, pancreatitis, nasal polyposis, and malabsorption.In addition to clinical symptoms or positive NBS results, sweat test and genetic analysis are cornerstones in the diagnosis of CF, but in some cases the diagnosis cannot be confirmed on genetic or sweat testing. Difficult diagnosis may be supported by in vivo or ex vivo electrophysiology measurements on respiratory or intestinal epithelia. This can be done by either measuring transepithelial nasal potential difference or intestinal current measurements.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/genética , Fibrose Cística/diagnóstico , Triagem Neonatal , Adulto , Criança , Ensaios Clínicos como Assunto , Fibrose Cística/genética , Diagnóstico Diferencial , Diagnóstico Precoce , Testes Genéticos , Humanos , Recém-Nascido , Mutação
9.
Ann Clin Microbiol Antimicrob ; 17(1): 14, 2018 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-29571294

RESUMO

BACKGROUND: Neisseria meningitidis is associated with meningitis and septicemia. Septic meningococcal arthritis is relatively uncommon and its diagnosis associated with clinical and microbiological challenges. Early recognition and treatment is required to prevent joint destruction. PURPOSE: We describe a case of an eleven-year-old boy with septic arthritis and the first reported use of a multiplexed diagnostic PCR test, capable of simultaneous rapid detection of 14 pathogens directly from CSF samples, to determine presence of N. meningitides in a synovial fluid sample. RESULTS: In this case, blood cultures and an aspiration of the joint fluid were negative for microbial growth, but leucocytes were present. Analysis of samples using the multiplexed FilmArray® meningitis/encephalitis panel (MEP) proved positive for N. meningitidis. In parallel, samples forwarded to an accredited reference laboratory confirmed the findings by bacterial 16S rRNA gene amplification and sequencing. Subsequent to these results, empiric treatment with intravenous flucloxacillin was discontinued and oral amoxicillin administered for 1 month. The status of the patient improved with etiology-based antimicrobial therapy. CONCLUSIONS: This case demonstrates difficulties associated with clinical and microbiological diagnosis of primary septic meningococcal arthritis. We describe the first successful use of the FilmArray® MEP assay in detection of N. meningitidis in that context.


Assuntos
Artrite Infecciosa/diagnóstico , Artrite Infecciosa/microbiologia , Encefalite/diagnóstico , Encefalite/microbiologia , Meningite Meningocócica/diagnóstico , Meningite Meningocócica/microbiologia , Reação em Cadeia da Polimerase Multiplex/métodos , Neisseria meningitidis/isolamento & purificação , Líquido Cefalorraquidiano/microbiologia , Criança , DNA Bacteriano/análise , DNA Bacteriano/sangue , DNA Bacteriano/líquido cefalorraquidiano , Humanos , Masculino , Técnicas de Diagnóstico Molecular/métodos , Neisseria meningitidis/genética , Neisseria meningitidis/patogenicidade , RNA Ribossômico 16S/genética , Sepse/diagnóstico , Sepse/microbiologia
12.
BMC Pulm Med ; 16(1): 57, 2016 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-27103163

RESUMO

BACKGROUND: Burkholderia contaminans is an emerging pathogen in the cystic fibrosis (CF) setting. Included in the Burkholderia cepacia complex (Bcc), B. contaminans is a Gram negative, motile, obligate aerobe previously classified as a pseudomonad. Previous reports have described B. contaminans isolation from patients in Portugal, Switzerland, Spain, Argentina and the USA. This, however, is the first report relating to B. contaminans affecting Irish patients with CF, initially detected in a paediatric setting. CASE PRESENTATION: Burkholderia contaminans was identified in the routine analysis of sputum from a fourteen year old boy, at his annual review and subsequently from the sputum from his 19 year old brother. RecA gene sequencing and pulsed field gel electrophoresis (PFGE) were unable to distinguish between the isolates, which demonstrated with susceptibility to ciprofloxacin, cotrimoxazole, meropenem, pipercillin/tazobactam and ceftazidime. Both isolates were resistant to aztreonam, with reduced susceptibility to tobramycin. Following treatment with intravenous meropenem and ceftazidime, oral ciprofloxacin and nebulised tobramycin for 6 weeks, sputum specimens from both patients were negative for B. contaminans. No other member of the local CF cohort proved positive. CONCLUSIONS: Bcc bacteria are associated with poor prognosis in CF and decreased life expectancy, specifically leading to a more rapid decline in lung function and, in some cases, to a fatal necrotizing pneumonia known as the "cepacia syndrome". Some species exhibit innate resistance to multiple antimicrobial agents and their transmission rate can be high in susceptible patients. In that context, we describe the first incidence of CF-related B. contaminans in Ireland and its successful eradication from two patients, one paediatric, using an aggressive antimicrobial regimen.


Assuntos
Infecções por Burkholderia/complicações , Complexo Burkholderia cepacia/isolamento & purificação , Fibrose Cística/complicações , Infecções Respiratórias/complicações , Água do Mar/microbiologia , Irmãos , Escarro/microbiologia , Adolescente , Infecções por Burkholderia/epidemiologia , Infecções por Burkholderia/microbiologia , Humanos , Incidência , Irlanda/epidemiologia , Masculino , Oceanos e Mares , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/microbiologia , Adulto Jovem
14.
BMC Pulm Med ; 15: 114, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26445233

RESUMO

BACKGROUND: Pseudomonas aeruginosa is a pathogen associated with cystic fibrosis that has potential to decrease lung function and cause respiratory failure. Paranasal sinuses are increasingly recognised as potential reservoirs for intermittent colonisation by P. aeruginosa. This case documents investigation and outcome of P. aeruginosa recurrence in a male paediatric patient over an eight year period. CASE PRESENTATION: A 12 year old Irish male paediatric cystic fibrosis patient experienced intermittent culturing of P. aeruginosa from the oropharyngeal region, indicating chronic infection of the sinuses despite absence of symptoms, retaining good lung function, and normal bronchoscopy and bronchoalveolar lavage. However, P. aeruginosa was isolated from a sinus wash-out and was identified as a unique strain of P. aeruginosa that was also cultured from cough swabs. Despite treatment, successful eradication from the paranasal sinuses was not achieved. CONCLUSIONS: Few reports have addressed the paranasal sinuses as a reservoir for lung infection in cystic fibrosis patients despite increased recognition of the need to investigate this niche. In this case, attempts at eradication of P. aeruginosa present in paranasal sinuses including oral and nebulised antimicrobials proved unsuccessful. However, detection of P. aeruginosa in the paranasal sinuses instigated antimicrobial treatment which may have contributed to prevention of migration to the lower airways. Our outcome provides additional insight and may indicate utility of nasal lavage or nasal endoscopy in paediatric cystic fibrosis patients' annual review clinic visits.


Assuntos
Antibacterianos/uso terapêutico , Portador Sadio/tratamento farmacológico , Fibrose Cística/terapia , Infecções por Pseudomonas/tratamento farmacológico , Sinusite/tratamento farmacológico , Criança , Fibrose Cística/complicações , Humanos , Masculino , Seios Paranasais/microbiologia , Infecções por Pseudomonas/complicações , Pseudomonas aeruginosa , Recidiva , Sinusite/complicações , Falha de Tratamento
16.
Eur Respir J ; 44(2): 394-404, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24696116

RESUMO

Airway disease in cystic fibrosis (CF) is characterised by impaired mucociliary clearance, persistent bacterial infection and neutrophilic inflammation. Lipoxin A4 (LXA4) initiates the active resolution of inflammation and promotes airway surface hydration in CF models. 15-Lipoxygenase (LO) plays a central role in the "class switch" of eicosanoid mediator biosynthesis from leukotrienes to lipoxins, initiating the active resolution of inflammation. We hypothesised that defective eicosanoid mediator class switching contributes to the failure to resolve inflammation in CF lung disease. Using bronchoalveolar lavage (BAL) samples from 46 children with CF and 19 paediatric controls we demonstrate that the ratio of LXA4 to leukotriene B4 (LTB4) is depressed in CF BAL (p<0.01), even in the absence of infection (p<0.001). Furthermore, 15-LO2 transcripts were significantly less abundant in CF BAL samples (p<0.05). In control BAL, there were positive relationships between 15-LO2 transcript abundance and LXA4/LTB4 ratio (p=0.01, r=0.66) and with percentage macrophage composition of the BAL fluid (p<0.001, r=0.82), which were absent in CF. Impoverished 15-LO2 expression and depression of the LXA4/LTB4 ratio are observed in paediatric CF BAL. These observations provide mechanistic insights into the failure to resolve inflammation in the CF lung.


Assuntos
Araquidonato 15-Lipoxigenase/metabolismo , Fibrose Cística/sangue , Leucotrieno B4/química , Lipoxinas/química , Antibacterianos/uso terapêutico , Líquido da Lavagem Broncoalveolar/química , Criança , Pré-Escolar , Fibrose Cística/metabolismo , Fibrose Cística/fisiopatologia , Feminino , Humanos , Inflamação , Leucotrieno A4/química , Estudos Longitudinais , Pulmão/imunologia , Pulmão/patologia , Pneumopatias/microbiologia , Macrófagos Alveolares/metabolismo , Masculino , Neutrófilos/citologia , Neutrófilos/metabolismo
17.
Ir J Med Sci ; 192(5): 2291-2299, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36417107

RESUMO

BACKGROUND: Oscillating positive expiratory pressure (OPEP) devices play a key role in airway clearance, particularly in patients with cystic fibrosis. These devices, however, have the potential to become reservoirs for pathogenic organisms and require daily, or even more frequent, cleaning. This places a large burden on patients and their carers. AIMS: The objective of this work was to develop a disposable OPEP device, with comparable mechanical performance to commercial devices, that negates the need for cleaning after use thus reducing microbiological risks. METHODS: 3D printing was used to iterate and develop a prototype disposable device (The University of Limerick OPEP, abbreviated to the UL-OPEP) that was compared with a selection of commercially available devices for mean pressure and oscillation amplitude (cmH2O), as well as oscillation frequency (Hz). All devices were tested using a healthy volunteer at a target expiratory flow of ~ 20 L/min. The target therapeutic range was 10-20 cmH2O at a flow rate of 10-20 L/min as is reported widely in the literature. RESULTS: The prototype disposable device achieved a mean pressure of 14.82 cmH2O at a mean flow rate of 18.82 L/min, and generated an oscillation frequency of 26 Hz with an amplitude of 1.28 cmH2O. These characteristics compare favourably with existing, more complex, reusable OPEP devices. CONCLUSIONS: The UL-OPEP device is a small, disposable OPEP device, that generates pressure and oscillation amplitudes for clinically effective airway clearance. The device negates the need for cleaning and disinfecting, removing the risk of devices acting as a potential reservoir for pathogenic organisms while maintaining mucus-clearing benefits.


Assuntos
Oscilação da Parede Torácica , Fibrose Cística , Humanos , Volume Expiratório Forçado , Fibrose Cística/terapia , Muco , Modalidades de Fisioterapia
18.
Access Microbiol ; 5(12)2023.
Artigo em Inglês | MEDLINE | ID: mdl-38188240

RESUMO

Introduction: Chryseobacterium shandongense is a Gram-negative Flavobacterium bacillus with intrinsic multidrug-resistant properties. Case Presentation: Herein, we present the first case report of human C. shandongense infection, relating to an implantable portal and catheter (port-a-cath) central line in a 5-year-old female with cystic fibrosis. The infection was identified using a Bruker MALDI-TOF Biotyper with BDAL (v12) of blood, which was cultured due to pyrexia and rigour following port-a-cath access. This report details the effective eradication of C. shandongense infection from the port-a-cath device using initial empirical gentamicin followed by targeted ciprofloxacin locks and systemic antibiotics. Conclusion: We demonstrated successful eradication of C. shandongense from a port-a-cath device, including the minimum inhibitory concentrations (MICs) required in this case. The result was eradication of central access infection, preventing progression to bacteraemia/septicaemia and preserving central access in a child with cystic fibrosis and established respiratory disease.

19.
J Cyst Fibros ; 22(3): 484-495, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36372700

RESUMO

BACKGROUND: The aim of this study was to record the current status of newborn bloodspot screening (NBS) for CF across Europe and assess performance. METHODS: Survey of representatives of NBS for CF programmes across Europe. Performance was assessed through a framework developed in a previous exercise. RESULTS: In 2022, we identified 22 national and 34 regional programmes in Europe. Barriers to establishing NBS included cost and political inertia. Performance was assessed from 2019 data reported by 21 national and 21 regional programmes. All programmes employed different protocols, with IRT-DNA the most common strategy. Six national and 11 regional programmes did not use DNA analysis. CONCLUSIONS: Integrating DNA analysis into the NBS protocol improves PPV, but at the expense of increased carrier and CFSPID recognition. Some programmes employ strategies to mitigate these outcomes. Programmes should constantly strive to improve performance but large datasets are needed to assess outcomes reliably.


Assuntos
Fibrose Cística , Testes Genéticos , Recém-Nascido , Humanos , Testes Genéticos/métodos , Fibrose Cística/diagnóstico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Tripsinogênio , Triagem Neonatal/métodos
20.
J Cyst Fibros ; 2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37806792

RESUMO

BACKGROUND: RECOVER is a multicentre post-approval study of Elexacaftor/Tezacaftor/Ivacaftor (ETI) in pwCF in Ireland and the UK. The CFAbd-Score is the first validated CF-specific patient reported outcome measure (PROM) focusing on gastrointestinal symptoms; it comprises 28 items in 5 domains. In a preliminary study, we previously reported reductions in abdominal symptoms (AS) in pwCF after 26 weeks of ETI-therapy using the CFAbd-Score. AIM: to assess changes in AS in a second, large cohort and explore novel GI-biomarkers of gut inflammation and cell-proliferation in pwCF over one year of ETI-therapy. METHODS: Participants were recruited as part of the RECOVER study at 8 sites (Ireland&UK). The CFAbd-Score was administered prior to ETI-initiation, and subsequently at 1,2,6 and 12 months on treatment. Faecal M2-pyruvate kinase (M2-PK) and calprotectin (FC) were quantified in samples collected at baseline, 1 and 6 months. RESULTS: 108 CFAbd-Scores and 73 stool samples were collected at baseline. After 12 months of ETI-therapy, total CFAbd-Scores had significantly declined (15.0±1.4→9.8±1.2pts/p<0.001), and so had all its five domains of "pain" (16.9±2.0pts→9.9±1.8pts/p<0.01), "GERD" (14.4±1.8→9.9±1.6/p<0.05), "disorders of bowel movements" (19.2±1.4→14.1±1.5/p<0.01), "appetite" (7.0±1.1→4.6±1.2/p<0.01) and "impaired-QoL" (13.3±1.9→7.5±1.5/p<0.001). Levels of M2-PK and FC significantly decreased during ETI-therapy. DISCUSSION: In-depth analysis of AS with the CFAbd-Score reveals a statistically significant, clinically relevant and sustained improvement with ETI. We attribute this to high sensitivity of the implemented CF-specific PROM, developed and validated following FDA-guidelines. Furthermore, for the first time during ETI-therapy a significant decline in faecal M2-PK, a marker of inflammation and cell-proliferation, was found, in parallel to FC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA