Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Clin Microbiol ; 50(1): 145-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22012021

RESUMO

Ninety-six samples from hepatitis B virus (HBV)-infected individuals were used to compare ViveST samples to frozen samples in COBAS TaqMan, RealArt, and VERSANT. Correlation (r) between ViveST samples and frozen samples was 0.99 in all three platforms. Correlations among tests using frozen samples were 0.96 for COBAS and RealArt, 0.94 for COBAS and VERSANT, and 0.97 for VERSANT and RealArt. The results indicate that ViveST may be useful in clinical practice. Different HBV-VL platforms correlated well with one another.


Assuntos
Dessecação/métodos , Vírus da Hepatite B/isolamento & purificação , Hepatite B/diagnóstico , Hepatite B/virologia , Plasma/virologia , Manejo de Espécimes/métodos , Carga Viral/métodos , Congelamento , Vírus da Hepatite B/genética , Humanos
3.
J Int AIDS Soc ; 17: 19262, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25413893

RESUMO

INTRODUCTION: Antiretroviral resistance leads to treatment failure and resistance transmission. Resistance data in western Kenya are limited. Collection of non-plasma analytes may provide additional resistance information. METHODS: We assessed HIV diversity using the REGA tool, transmitted resistance by the WHO mutation list and acquired resistance upon first-line failure by the IAS-USA mutation list, at the Academic Model Providing Access to Healthcare (AMPATH), a major treatment programme in western Kenya. Plasma and four non-plasma analytes, dried blood-spots (DBS), dried plasma-spots (DPS), ViveST(TM)-plasma (STP) and ViveST-blood (STB), were compared to identify diversity and evaluate sequence concordance. RESULTS: Among 122 patients, 62 were treatment-naïve and 60 treatment-experienced; 61% were female, median age 35 years, median CD4 182 cells/µL, median viral-load 4.6 log10 copies/mL. One hundred and ninety-six sequences were available for 107/122 (88%) patients, 58/62 (94%) treatment-naïve and 49/60 (82%) treated; 100/122 (82%) plasma, 37/78 (47%) attempted DBS, 16/45 (36%) attempted DPS, 14/44 (32%) attempted STP from fresh plasma and 23/34 (68%) from frozen plasma, and 5/42 (12%) attempted STB. Plasma and DBS genotyping success increased at higher VL and shorter shipment-to-genotyping time. Main subtypes were A (62%), D (15%) and C (6%). Transmitted resistance was found in 1.8% of plasma sequences, and 7% combining analytes. Plasma resistance mutations were identified in 91% of treated patients, 76% NRTI, 91% NNRTI; 76% dual-class; 60% with intermediate-high predicted resistance to future treatment options; with novel mutation co-occurrence patterns. Nearly 88% of plasma mutations were identified in DBS, 89% in DPS and 94% in STP. Of 23 discordant mutations, 92% in plasma and 60% in non-plasma analytes were mixtures. Mean whole-sequence discordance from frozen plasma reference was 1.1% for plasma-DBS, 1.2% plasma-DPS, 2.0% plasma-STP and 2.3% plasma-STB. Of 23 plasma-STP discordances, one mutation was identified in plasma and 22 in STP (p<0.05). Discordance was inversely significantly related to VL for DBS. CONCLUSIONS: In a large treatment programme in western Kenya, we report high HIV-1 subtype diversity; low plasma transmitted resistance, increasing when multiple analytes were combined; and high-acquired resistance with unique mutation patterns. Resistance surveillance may be augmented by using non-plasma analytes for lower-cost genotyping in resource-limited settings.


Assuntos
Antirretrovirais/farmacologia , Sangue/virologia , Farmacorresistência Viral , Variação Genética , Técnicas de Genotipagem/métodos , Infecções por HIV/virologia , HIV-1/efeitos dos fármacos , Adulto , Idoso , Feminino , Genótipo , HIV-1/classificação , HIV-1/genética , HIV-1/isolamento & purificação , Humanos , Quênia , Masculino , Testes de Sensibilidade Microbiana/métodos , Pessoa de Meia-Idade , Manejo de Espécimes/métodos , Adulto Jovem
4.
PLoS One ; 7(7): e40514, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22815755

RESUMO

Failure of antiretroviral regimens containing elvitegravir (EVG) and raltegravir (RAL) can result in the appearance of integrase inhibitor (INI) drug-resistance mutations (DRMs). While several INI DRMs have been identified, the evolution of EVG DRMs and the linkage of these DRMs with protease inhibitor (PI) and reverse transcriptase inhibitor (RTI) DRMs have not been studied at the clonal level. We examined the development of INI DRMs in 10 patients failing EVG-containing regimens over time, and the linkage of INI DRMs with PI and RTI DRMs in these patients plus 6 RAL-treated patients. A one-step RT-nested PCR protocol was used to generate a 2.7 kB amplicon that included the PR, RT, and IN coding region, and standard cloning and sequencing techniques were used to determine DRMs in 1,277 clones (mean 21 clones per time point). Results showed all patients had multiple PI, NRTI, and/or NNRTI DRMs at baseline, but no primary INI DRM. EVG-treated patients developed from 2 to 6 strains with different primary INI DRMs as early as 2 weeks after initiation of treatment, predominantly as single mutations. The prevalence of these strains fluctuated and new strains, and/or strains with new combinations of INI DRMs, developed over time. Final failure samples (weeks 14 to 48) typically showed a dominant strain with multiple mutations or N155H alone. Single N155H or multiple mutations were also observed in RAL-treated patients at virologic failure. All patient strains showed evidence of INI DRM co-located with single or multiple PI and/or RTI DRMs on the same viral strand. Our study shows that EVG treatment can select for a number of distinct INI-resistant strains whose prevalence fluctuates over time. Continued appearance of new INI DRMs after initial INI failure suggests a potent, highly dynamic selection of INI resistant strains that is unaffected by co-location with PI and RTI DRMs.


Assuntos
Farmacorresistência Viral/genética , Inibidores de Integrase de HIV/farmacologia , Integrase de HIV/genética , Transcriptase Reversa do HIV/genética , Mutação , Peptídeo Hidrolases/genética , Quinolonas/farmacologia , HIV-1/efeitos dos fármacos , HIV-1/enzimologia , HIV-1/genética , Humanos , Dados de Sequência Molecular , Fases de Leitura Aberta/genética , Inibidores de Proteases/farmacologia
5.
J Acquir Immune Defic Syndr ; 32(3): 292-7, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12626889

RESUMO

A retrospective, blinded study was conducted to examine the prevalence of antiretroviral drug resistance among a cohort of HIV-infected infants born in 1998 and 1999 in New York State. The earliest available HIV-positive specimen was tested. Most samples were from infants younger than 60 days of age. Genotype data were generated for the protease and reverse transcriptase genes of HIV-1 proviral DNA from 91 infected infants. Eleven infants (12.1%) had provirus with mutations associated with drug resistance, with all three classes of antiretroviral drugs represented. Two infants (2.2%) had mutations associated with resistance to two classes of antiretrovirals. Perinatal antiretroviral drug exposure was examined; it was not found to be significantly associated with the presence of resistance mutations. However, for those infants who had perinatal antiretroviral exposure and genotypic evidence of drug resistance to HIV, the mutations that were detected correlated with at least one antiretroviral from the perinatal period. The prevalence of genotypic drug resistance among this infant cohort is comparable with that found among recently infected adults. These results suggest that resistance testing should be strongly considered for perinatally infected infants, at the earliest possible time point, to avoid use of antiretroviral drugs to which the infant has preexisting resistance.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/tratamento farmacológico , HIV-1/efeitos dos fármacos , Estudos de Coortes , DNA Viral/genética , Farmacorresistência Viral/genética , Feminino , Genótipo , Infecções por HIV/epidemiologia , Infecções por HIV/genética , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/genética , Humanos , Lactente , Recém-Nascido , Masculino , New York/epidemiologia , Assistência Perinatal , Provírus/genética , Estudos Retrospectivos
6.
J Clin Microbiol ; 41(4): 1594-9, 2003 04.
Artigo em Inglês | MEDLINE | ID: mdl-12682150

RESUMO

The TRUGENE HIV-1 Genotyping Kit and OpenGene DNA Sequencing System are designed to sequence the protease (PR)- and reverse transcriptase (RT)-coding regions of human immunodeficiency virus type 1 (HIV-1) pol. Studies were undertaken to determine the accuracy of this assay system in detecting resistance-associated mutations and to determine the effects of RNA extraction methods, anticoagulants, specimen handling, and potentially interfering substances. Samples were plasma obtained from HIV-infected subjects or seronegative plasma to which viruses derived from wild-type and mutant infectious molecular clones (IMC) of HIV-1 were added. Extraction methods tested included standard and UltraSensitive AMPLICOR HIV-1 MONITOR, QIAGEN viral RNA extraction mini kit, and QIAGEN Ultra HIV extraction kit, and NASBA manual HIV-1 quantitative NucliSens. Sequence data from test sites were compared to a "gold standard" reference sequence to determine the percent agreement. Comparisons between test and reference sequences at the nucleotide level showed 97.5 to 100% agreement. Similar results were obtained regardless of extraction method, regardless of use of EDTA or acid citrate dextrose as anticoagulant, and despite the presence of triglycerides, bilirubin, hemoglobin, antiretroviral drugs, HIV-2, hepatitis C virus (HCV), HBV, cytomegalovirus, human T-cell leukemia virus type 1 (HTLV-1), or HTLV-2. Samples with HIV-1 RNA titers of >or=1,000 copies/ml gave consistent results. The TRUGENE HIV-1 Genotyping Kit and OpenGene DNA Sequencing System consistently generate highly accurate sequence data when tested with IMC-derived HIV and patient samples.


Assuntos
Farmacorresistência Viral/genética , HIV-1/efeitos dos fármacos , RNA Viral/sangue , Kit de Reagentes para Diagnóstico , Análise de Sequência de DNA , Anticoagulantes , Genótipo , Infecções por HIV/virologia , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/enzimologia , HIV-1/genética , Humanos , Dados de Sequência Molecular , Mutação , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos
7.
J Clin Microbiol ; 41(4): 1586-93, 2003 04.
Artigo em Inglês | MEDLINE | ID: mdl-12682149

RESUMO

Drug resistance and poor virological responses are associated with well-characterized mutations in the viral reading frames that encode the proteins that are targeted by currently available antiretroviral drugs. An integrated system was developed that includes target gene amplification, DNA sequencing chemistry (TRUGENE HIV-1 Genotyping Kit), and hardware and interpretative software (the OpenGene DNA Sequencing System) for detection of mutations in the human immunodeficiency virus type 1 (HIV-1) protease and reverse transcriptase sequences. The integrated system incorporates reverse transcription-PCR from extracted HIV-1 RNA, a coupled amplification and sequencing step (CLIP), polyacrylamide gel electrophoresis, semiautomated analysis of data, and generation of an interpretative report. To assess the accuracy and robustness of the assay system, 270 coded plasma specimens derived from nine patients were sent to six laboratories for blinded analysis. All specimens contained HIV-1 subtype B viruses. Results of 270 independent assays were compared to "gold standard" consensus sequences of the virus populations determined by sequence analysis of 16 to 20 clones of viral DNA amplicons derived from two independent PCRs using primers not used in the kit. The accuracy of the integrated system for nucleotide base identification was 98.7%, and the accuracy for codon identification at 54 sites associated with drug resistance was 97.6%. In a separate analysis of plasma spiked with infectious molecular clones, the assay reproducibly detected all 72 different drug resistance mutations that were evaluated. There were no significant differences in accuracy between laboratories, between technologists, between kit lots, or between days. This integrated assay system for the detection of HIV-1 drug resistance mutations has a high degree of accuracy and reproducibility in several laboratories.


Assuntos
Fármacos Anti-HIV/farmacologia , Farmacorresistência Viral/genética , Infecções por HIV/virologia , HIV-1/classificação , HIV-1/genética , Kit de Reagentes para Diagnóstico , Amplificação de Genes , Genótipo , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/efeitos dos fármacos , Humanos , Laboratórios , Dados de Sequência Molecular , Mutação , RNA Viral/sangue , Reprodutibilidade dos Testes , Análise de Sequência de DNA , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA