Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 625(7996): 673-678, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38267680

RESUMO

Quantum electrodynamics (QED), the quantum field theory that describes the interaction between light and matter, is commonly regarded as the best-tested quantum theory in modern physics. However, this claim is mostly based on extremely precise studies performed in the domain of relatively low field strengths and light atoms and ions1-6. In the realm of very strong electromagnetic fields such as in the heaviest highly charged ions (with nuclear charge Z ≫ 1), QED calculations enter a qualitatively different, non-perturbative regime. Yet, the corresponding experimental studies are very challenging, and theoretical predictions are only partially tested. Here we present an experiment sensitive to higher-order QED effects and electron-electron interactions in the high-Z regime. This is achieved by using a multi-reference method based on Doppler-tuned X-ray emission from stored relativistic uranium ions with different charge states. The energy of the 1s1/22p3/2 J = 2 → 1s1/22s1/2 J = 1 intrashell transition in the heaviest two-electron ion (U90+) is obtained with an accuracy of 37 ppm. Furthermore, a comparison of uranium ions with different numbers of bound electrons enables us to disentangle and to test separately the one-electron higher-order QED effects and the bound electron-electron interaction terms without the uncertainty related to the nuclear radius. Moreover, our experimental result can discriminate between several state-of-the-art theoretical approaches and provides an important benchmark for calculations in the strong-field domain.

2.
J Synchrotron Radiat ; 28(Pt 1): 176-180, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399566

RESUMO

Dichroism is one of the most important optical effects in both the visible and the X-ray range. Besides absorption, scattering can also contribute to dichroism. This paper demonstrates that, based on the example of polyimide, materials can show tiny dichroism even far from electronic resonances due to scattering. Although the effect is small, it can lead to a measurable polarization change and might have influence on highly sensitive polarimetric experiments.

3.
Rev Sci Instrum ; 93(11): 113301, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461450

RESUMO

In this work, the first proof of the principal of an in situ diagnostics of the heavy-ion beam intensity distribution in irradiation of solid targets is proposed. In this scheme, x-ray fluorescence that occurs in the interaction of heavy-ions with target atoms is used for imaging purposes. The x-ray conversion to optical radiation and a transport-system was developed, and its first test was performed in experiments at the Universal Linear Accelerator in Darmstadt, Germany. The Au-beam intensity distribution on thin foils and Cu-mesh targets was imaged using multiple x-ray pinholes (polychromatic imaging) and 2D monochromatic imaging of Cu Kα radiation by using a toroidally bent silicon crystal. The presented results are of importance for application in experiments on the investigation of the equation of states of high energy density matter using high intensity GeV/u heavy-ion beams of ≥1010 particles/100 ns.

4.
Rev Sci Instrum ; 92(1): 013101, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514249

RESUMO

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

5.
Sci Rep ; 10(1): 14564, 2020 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-32884061

RESUMO

We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within [Formula: see text] for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.

7.
Rev Sci Instrum ; 83(11): 113507, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206062

RESUMO

We developed a detection scheme, capable of measuring X-ray line shape of tracer ions in µm thick layers at the rear side of a target foil irradiated by ultra intense laser pulses. We performed simulations of the effect of strong electric fields on the K-shell emission of silicon and developed a spectrometer dedicated to record this emission. The combination of a cylindrically bent crystal in von Hámos geometry and a CCD camera with its single photon counting capability allows for a high dynamic range of the instrument and background free spectra. This approach will be used in future experiments to study electric fields of the order of TV/m at high density plasmas close to solid density.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 81(2 Pt 2): 026406, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20365664

RESUMO

We study warm dense matter formed by subpicosecond laser irradiation at several 10(19) W/cm(2) of thin Ti foils using x-ray spectroscopy with high spectral (E/DeltaE approximately 15,000) and one-dimensional spatial (Deltax=13.5 microm) resolutions. Ti Kalpha doublets modeled by line-shape calculations are compared with Abel-inverted single-pulse experimental spectra and provide radial distributions of the bulk-electron temperature and the absolute-photon number Kalpha yield in the target interiors. A core with approximately 40 eV extends homogeneously up to ten times the laser-focus size. The spatial distributions of the bulk-electron temperature and Kalpha yield are strongly correlated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA