RESUMO
PURPOSE: Breast cancer (BC) patients undergoing FDG-PET/CT scans for neoadjuvant chemotherapy (NAC) may have additional non-BC related findings. The aim of this study is to describe the clinical implications of these findings. METHODS: We included BC patients who underwent an FDG-PET/CT scan in our institute between 2011-2020 prior to NAC. We focused on patients with an additional non-BC related finding (i.e. BC metastases were excluded) for which diagnostic work-up was performed. Information about the diagnostic work-up and the clinical consequences was retrospectively gathered. A revision of all FDG-PET/CT scans was conducted by an independent physician to assess the suspicion level of the additional findings. RESULTS: Of the 1337 patients who underwent FDG-PET/CT, 202 patients (15%) had an non-BC related additional finding for which diagnostic work-up was conducted, resulting in 318 examinations during the first year. The non-BC related findings were mostly detected in the endocrine region (26%), gastro-intestinal region (16%), or the lungs (15%). Seventeen patients (17/202: 8%, 17/1337: 1.3%) had a second primary malignancy. Only 8 patients (8/202: 4%, 8/1337: 0.6%) had a finding that was considered more prognosis-determining than their BC disease. When revising all FDG-PET/CT scans, 57 (202/57: 28%) of the patients had an additional finding categorized as low suspicious, suggesting no indication for diagnostic work-up. CONCLUSION: FDG-PET/CT scans used for dissemination imaging in BC patients detect a high number of non-BC related additional findings, often clinically irrelevant and causing a large amount of unnecessary work-up. However, in 8% of the patients undergoing diagnostic work-up for an additional finding, a second primary malignancy was detected, warranting diagnostic attention in selected patients.
Assuntos
Neoplasias da Mama , Fluordesoxiglucose F18 , Terapia Neoadjuvante , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Adulto , Compostos Radiofarmacêuticos , Quimioterapia Adjuvante , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêuticoRESUMO
PURPOSE: This study aims to identify which breast cancer patients benefit from the routine use of FDG-PET/CT in a large cohort of patients scheduled for neoadjuvant systemic therapy (NST). METHODS: A total of 1337 breast cancer patients eligible for NST were identified from a retrospective database between 2011 and 2020 at a single tertiary care hospital. All patients underwent staging with FDG-PET/CT prior to NST. The incidence and extent of asymptomatic distant metastases in different patient subgroups were determined, as well as the impact on treatment. Logistic regression analysis was used to identify prognostic patient and tumor characteristics. RESULTS: FDG-PET/CT detected distant metastases in 109 patients (8%). Initial clinical stage was a prognostic factor for the presence of distant metastases, with a significantly higher risk for stage 2b and 3 as opposed to lower stages (p < 0.001). The incidence of distant metastases was 3% (4/125) for stage 1, 2% (8/534) for stage 2a, 7% (24/354) for stage 2b and 23% (73/324) for stage 3. Other characteristics such as age, tumor subtype, histological type and grade were not correlated with the risk of distant metastases. Among the subset of patients with distant metastases, 46% received palliative treatment, while the remaining 54% were diagnosed with oligometastatic breast cancer and were treated with curative intent. CONCLUSION: The results of the current study support the routine use of FDG-PET/CT for the detection of distant metastases in breast cancer patients with initial clinical stage 2b and 3, regardless of tumor subtype.
RESUMO
INTRODUCTION: Breast cancer patients with invasive lobular carcinoma (ILC) have an increased risk of positive margins after surgery and often show little response to neoadjuvant chemotherapy (NAC). We aimed to investigate surgical outcomes in patients with ILC treated with NAC. METHODS: In this retrospective cohort study, all breast cancer patients with ILC treated with NAC who underwent surgery at the Netherlands Cancer Institute from 2010 to 2019 were selected. Patients with mixed type ILC in pre-NAC biopsies were excluded if the lobular component was not confirmed in the surgical specimen. Main outcomes were tumor-positive margins and re-excision rate. Associations between baseline characteristics and tumor-positive margins were assessed, as were complications, locoregional recurrence rate (LRR), recurrence-free survival (RFS), and overall survival (OS). RESULTS: We included 191 patients. After NAC, 107 (56%) patients had breast conserving surgery (BCS) and 84 (44%) patients underwent mastectomy. Tumor-positive margins were observed in 67 (35%) patients. Fifty five (51%) had BCS and 12 (14%) underwent mastectomy (p value < 0.001). Re-excision was performed in 35 (33%) patients with BCS and in 4 (5%) patients with mastectomy. Definitive surgery was mastectomy in 107 (56%) patients and BCS in 84 (44%) patients. Tumor-positive margins were associated with cT ≥ 3 status (OR 4.62, 95% CI 1.26-16.98, p value 0.021) in the BCS group. Five-year LRR (4.7%), RFS (81%), and OS (93%) were not affected by type of surgery after NAC. CONCLUSION: Although 33% of ILC breast cancer patients undergoing BCS after NAC required re-excision for positive resection margins, it is considered safe given that five-year RFS remained excellent and LRR and OS did not differ by extent of surgery.
Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Carcinoma Lobular , Humanos , Feminino , Carcinoma Lobular/tratamento farmacológico , Carcinoma Lobular/cirurgia , Carcinoma Lobular/patologia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Mastectomia , Terapia Neoadjuvante , Estudos Retrospectivos , Recidiva Local de Neoplasia/cirurgia , Mastectomia Segmentar , Margens de Excisão , Carcinoma Ductal de Mama/patologiaRESUMO
OBJECTIVES: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion. METHODS: We calculated the re-attendance rates of the second and third MRI screening rounds of the DENSE trial. Moreover, we calculated age-adjusted odds ratios (ORs) to study the association between characteristics and re-attendance. Women who discontinued MRI screening were asked to provide one or more reasons for this. RESULTS: The re-attendance rates were 81.3% (3458/4252) and 85.2% (2693/3160) in the second and third MRI screening round, respectively. A high age (> 65 years), a very low BMI, lower education, not being employed, smoking, and no alcohol consumption were correlated with lower re-attendance rates. Moderate or high levels of pain, discomfort, or anxiety experienced during the previous MRI screening round were correlated with lower re-attendance rates. Finally, a plurality of women mentioned an examination-related inconvenience as a reason to discontinue screening (39.1% and 34.8% in the second and third screening round, respectively). CONCLUSIONS: The willingness of women with dense breasts to re-attend an ongoing MRI screening study is high. However, emphasis should be placed on improving the MRI experience to increase the re-attendance rate if widespread supplemental MRI screening is implemented. CLINICAL RELEVANCE STATEMENT: For many women, MRI is an acceptable screening method, as re-attendance rates were high - even for screening in a clinical trial setting. To further enhance the (re-)attendance rate, one possible approach could be improving the overall MRI experience. KEY POINTS: ⢠The willingness to re-attend in an ongoing MRI screening study is high. ⢠Pain, discomfort, and anxiety in the previous MRI screening round were related to lower re-attendance rates. ⢠Emphasis should be placed on improving MRI experience to increase the re-attendance rate in supplemental MRI screening.
Assuntos
Densidade da Mama , Neoplasias da Mama , Detecção Precoce de Câncer , Imageamento por Ressonância Magnética , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/estatística & dados numéricos , Idoso , Cooperação do Paciente/estatística & dados numéricos , Programas de Rastreamento/estatística & dados numéricos , AdultoRESUMO
BACKGROUND: Neoadjuvant systemic treatment (NST) leads to pathologic complete response (pCR) in 10-89% of breast cancer patients depending on subtype. The added value of surgery is uncertain in patients who reach pCR; however, current imaging and biopsy techniques aiming to predict pCR are not accurate enough. This study aims to quantify the residual disease remaining after NST in patients with a favorable response on MRI and residual disease missed with biopsies. METHODS: In the MICRA trial, patients with a favorable response to NST on MRI underwent ultrasound-guided post-NST 14G biopsies followed by surgery. We analyzed pathology reports of the biopsies and the surgical specimens. Primary outcome was the extent of residual invasive disease among molecular subtypes, and secondary outcome was the extent of missed residual invasive disease. RESULTS: We included 167 patients. Surgical specimen showed residual invasive disease in 69 (41%) patients. The median size of residual invasive disease was 18 mm (interquartile range [IQR] 12-30) in hormone receptor-positive (HR+)/human epidermal growth factor receptor 2-negative (HER2-) patients, 8 mm (IQR 3-15) in HR+/HER2-positive (HER2+) patients, 4 mm (IQR 2-9) in HR-negative (HR-)/HER2+ patients, and 5 mm (IQR 2-11) in triple-negative (TN) patients. Residual invasive disease was missed in all subtypes varying from 4 to 7 mm. CONCLUSION: Although the extent of residual invasive disease is small in TN and HER2+ subtypes, substantial residual invasive disease is left behind in all subtypes with 14G biopsies. This may hamper local control and limits adjuvant systemic treatment options. Therefore, surgical excision remains obligatory until accuracy of imaging and biopsy techniques improve.
Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Neoplasias da Mama/metabolismo , Receptor ErbB-2/metabolismo , Terapia Neoadjuvante/métodos , Biópsia Guiada por Imagem/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêuticoRESUMO
BACKGROUND: Extremely dense breast tissue is a risk factor for breast cancer and limits the detection of cancer with mammography. Data are needed on the use of supplemental magnetic resonance imaging (MRI) to improve early detection and reduce interval breast cancers in such patients. METHODS: In this multicenter, randomized, controlled trial in the Netherlands, we assigned 40,373 women between the ages of 50 and 75 years with extremely dense breast tissue and normal results on screening mammography to a group that was invited to undergo supplemental MRI or to a group that received mammography screening only. The groups were assigned in a 1:4 ratio, with 8061 in the MRI-invitation group and 32,312 in the mammography-only group. The primary outcome was the between-group difference in the incidence of interval cancers during a 2-year screening period. RESULTS: The interval-cancer rate was 2.5 per 1000 screenings in the MRI-invitation group and 5.0 per 1000 screenings in the mammography-only group, for a difference of 2.5 per 1000 screenings (95% confidence interval [CI], 1.0 to 3.7; P<0.001). Of the women who were invited to undergo MRI, 59% accepted the invitation. Of the 20 interval cancers that were diagnosed in the MRI-invitation group, 4 were diagnosed in the women who actually underwent MRI (0.8 per 1000 screenings) and 16 in those who did not accept the invitation (4.9 per 1000 screenings). The MRI cancer-detection rate among the women who actually underwent MRI screening was 16.5 per 1000 screenings (95% CI, 13.3 to 20.5). The positive predictive value was 17.4% (95% CI, 14.2 to 21.2) for recall for additional testing and 26.3% (95% CI, 21.7 to 31.6) for biopsy. The false positive rate was 79.8 per 1000 screenings. Among the women who underwent MRI, 0.1% had either an adverse event or a serious adverse event during or immediately after the screening. CONCLUSIONS: The use of supplemental MRI screening in women with extremely dense breast tissue and normal results on mammography resulted in the diagnosis of significantly fewer interval cancers than mammography alone during a 2-year screening period. (Funded by the University Medical Center Utrecht and others; DENSE ClinicalTrials.gov number, NCT01315015.).
Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética , Mamografia , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/epidemiologia , Reações Falso-Positivas , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
PURPOSE: In clinically node-positive (cN+) breast cancer patients, evidence supporting response-guided treatment after neoadjuvant systemic therapy (NST) instead of axillary lymph node dissection (ALND) is increasing, but follow-up results are lacking. We assessed three-year axillary recurrence-free interval (aRFI) in cN+ patients with response-adjusted axillary treatment according to the 'Marking Axillary lymph nodes with Radioactive Iodine seeds' (MARI)-protocol. METHODS: We retrospectively assessed all stage II-III cytologically proven cN+ breast cancer patients who underwent the MARI-protocol between July 2014 and November 2018. Pre-NST axillary staging with FDG-PET/CT (less- or more than four suspicious axillary nodes; cALN < 4 or cALN ≥ 4) and post-NST pathological axillary response measured in the pre-NST largest tumor-positive axillary lymph node marked with an iodine seed (MARI-node; ypMARI-neg or ypMARI-pos) determined axillary treatment: no further treatment (cALN < 4, ypMARI-neg), axillary radiotherapy (ART) (cALN < 4, ypMARI-pos and cALN ≥ 4, ypMARI-neg) or ALND plus ART (cALN ≥ 4, ypMARI-pos). RESULTS: Of 272 women included, the MARI-node was tumor-negative in 56 (32%) of 174 cALN < 4 patients and 43 (44%) of 98 cALN ≥ 4 patients. According to protocol, 56 (21%) patients received no further axillary treatment, 161 (59%) received ART and 55 (20%) received ALND plus ART. Median follow-up was 3.0 years (IQR 1.9-4.1). Five patients (one no further treatment, four ART) had axillary metastases. Three-year aRFI was 98% (95% CI 96-100). The overall recurrence risk remained highest for patients with ALND (HR 4.36; 95% CI 0.95-20.04, p = 0.059). CONCLUSIONS: De-escalation of axillary treatment according to the MARI-protocol prevented ALND in 80% of cN+ patients with an excellent three-year aRFI of 98%.
Assuntos
Neoplasias da Mama , Neoplasias da Glândula Tireoide , Axila/patologia , Neoplasias da Mama/patologia , Feminino , Seguimentos , Humanos , Radioisótopos do Iodo , Excisão de Linfonodo/métodos , Linfonodos/patologia , Terapia Neoadjuvante/métodos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela/métodosRESUMO
PURPOSE: Intensive screening in BRCA1/2 mutation carriers aims to improve breast cancer (BC) prognosis. Our aim is to clarify the prognostic impact of tumor size in BRCA mutation carriers with a pT1 BC, which is currently unclear. We are especially interested in differences between pT1a, pT1b, and pT1c regarding the prognosis of node-negative breast cancer, the effect of chemotherapy, and the prevalence of lymph node involvement. METHODS: For this study, BRCA1/2-associated BC patients were selected from a nationwide cohort. Primary outcomes were 10-year overall survival (OS) per pT1a-b-c group and the effect of chemotherapy on prognosis of node-negative BC, using Kaplan-Meier and Cox models. Finally, we evaluated lymph node involvement per pT1a-b-c group. RESULTS: 963 women with pT1 BRCA1/2-associated BC diagnosed between 1990 and 2017 were included, of which 679 had pN0 BC. After a median follow-up of 10.5 years, 10-year OS in patients without chemotherapy was 77.1% in pT1cN0 and lower than for pT1aN0 (91.4%, p = 0.119) and pT1bN0 (90.8%, p = 0.024). OS was better with than without chemotherapy for pT1cN0 (91.6% vs. 77.1%, p = 0.001; hazard ratio (HR) 0.56, 95% confidence interval (CI): 0.21-1.48). Lymph node involvement was 24.9% in pT1c, 18.8% in pT1b, and 8.6% in pT1a. CONCLUSION: Smaller tumor size is associated with better OS and less lymph node involvement in pT1 BRCA1/2-associated BC patients. The results suggest that early detection in BRCA1/2 mutation carriers of pT1a/b BC may reduce mortality and the need for systemic therapy.
Assuntos
Neoplasias da Mama , Proteína BRCA1/genética , Proteína BRCA2/genética , Mama/patologia , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Estudos de Coortes , Feminino , Humanos , Mutação , PrognósticoRESUMO
Background High breast density increases breast cancer risk and lowers mammographic sensitivity. Supplemental MRI screening improves cancer detection but increases the number of false-positive screenings. Thus, methods to distinguish true-positive MRI screening results from false-positive ones are needed. Purpose To build prediction models based on clinical characteristics and MRI findings to reduce the rate of false-positive screening MRI findings in women with extremely dense breasts. Materials and Methods Clinical characteristics and MRI findings in Dutch breast cancer screening participants (age range, 50-75 years) with positive first-round MRI screening results (Breast Imaging Reporting and Data System 3, 4, or 5) after a normal screening mammography with extremely dense breasts (Volpara density category 4) were prospectively collected within the randomized controlled Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial from December 2011 through November 2015. In this secondary analysis, prediction models were built using multivariable logistic regression analysis to distinguish true-positive MRI screening findings from false-positive ones. Results Among 454 women (median age, 52 years; interquartile range, 50-57 years) with a positive MRI result in a first supplemental MRI screening round, 79 were diagnosed with breast cancer (true-positive findings), and 375 had false-positive MRI results. The full prediction model (area under the receiver operating characteristics curve [AUC], 0.88; 95% CI: 0.84, 0.92), based on all collected clinical characteristics and MRI findings, could have prevented 45.5% (95% CI: 39.6, 51.5) of false-positive recalls and 21.3% (95% CI: 15.7, 28.3) of benign biopsies without missing any cancers. The model solely based on readily available MRI findings and age had a comparable performance (AUC, 0.84; 95% CI: 0.79, 0.88; P = .15) and could have prevented 35.5% (95% CI: 30.4, 41.1) of false-positive MRI screening results and 13.0% (95% CI: 8.8, 18.6) of benign biopsies. Conclusion Prediction models based on clinical characteristics and MRI findings may be useful to reduce the false-positive first-round screening MRI rate and benign biopsy rate in women with extremely dense breasts. Clinical trial registration no. NCT01315015 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Imbriaco in this issue.
Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Mama/diagnóstico por imagem , Reações Falso-Positivas , Feminino , Humanos , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Many cT3 breast cancer patients are treated with mastectomy, regardless of response to neoadjuvant systemic therapy (NST). We evaluated local control of cT3 patients undergoing breast-conserving therapy (BCT) based on magnetic resonance imaging (MRI) evaluation post-NST. In addition, we analyzed predictive characteristics for positive margins after breast-conserving surgery (BCS). METHODS: All cT3 breast cancer patients who underwent BCS after NST between 2002 and 2015 at the Netherlands Cancer Institute were included. Local recurrence-free interval (LRFI) was estimated using the Kaplan-Meier method, and predictors for positive margins were analyzed using univariable analysis and multivariable logistic regression. RESULTS: Of 114 patients undergoing BCS post-NST, 75 had negative margins, 16 had focally positive margins, and 23 had positive margins. Of those with (focally) positive margins, 12 underwent radiotherapy, 6 underwent re-excision, and 21 underwent mastectomy. Finally, 93/114 patients were treated with BCT (82%), with an LRFI of 95.9% (95% confidence interval [CI] 91.5-100%) after a median follow-up of 7 years. Predictors for positive margins in univariable analysis were hormone receptor-positive/human epidermal growth factor receptor 2-negative (HR+/HER2-) subtype, lobular carcinoma, and non-mass enhancement (NME) on pre-NST MRI. MRI response was not correlated to positive margins. In multivariable regression, the odds of positive margins were decreased in patients with HER2-positive (HER2+; odds ratio [OR] 0.27, 95% CI 0.10-0.73; p = 0.01) and TN tumors (OR 0.17, 95% CI 0.03-0.82; p = 0.028). A trend toward positive margins was observed in patients with NME (OR 2.38, 95% CI 0.98-5.77; p = 0.055). CONCLUSION: BCT could be performed in 82% of cT3 patients in whom BCT appeared feasible on post-NST MRI. Local control in these patients was excellent. In those patients with HR+/HER2- tumors, NME on MRI, or invasive lobular carcinoma, the risk of positive margins should be considered preoperatively.
Assuntos
Neoplasias da Mama , Mastectomia Segmentar , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia , Terapia Neoadjuvante , Recidiva Local de Neoplasia/diagnóstico por imagemRESUMO
BACKGROUND: The added value of surgery in breast cancer patients with pathological complete response (pCR) after neoadjuvant systemic therapy (NST) is uncertain. The accuracy of imaging identifying pCR for omission of surgery, however, is insufficient. We investigated the accuracy of ultrasound-guided biopsies identifying breast pCR (ypT0) after NST in patients with radiological partial (rPR) or complete response (rCR) on MRI. METHODS: We performed a multicenter, prospective single-arm study in three Dutch hospitals. Patients with T1-4(N0 or N +) breast cancer with MRI rPR and enhancement ≤ 2.0 cm or MRI rCR after NST were enrolled. Eight ultrasound-guided 14-G core biopsies were obtained in the operating room before surgery close to the marker placed centrally in the tumor area at diagnosis (no attempt was made to remove the marker), and compared with the surgical specimen of the breast. Primary outcome was the false-negative rate (FNR). RESULTS: Between April 2016 and June 2019, 202 patients fulfilled eligibility criteria. Pre-surgical biopsies were obtained in 167 patients, of whom 136 had rCR and 31 had rPR on MRI. Forty-three (26%) tumors were hormone receptor (HR)-positive/HER2-negative, 64 (38%) were HER2-positive, and 60 (36%) were triple-negative. Eighty-nine patients had pCR (53%; 95% CI 45-61) and 78 had residual disease. Biopsies were false-negative in 29 (37%; 95% CI 27-49) of 78 patients. The multivariable associated with false-negative biopsies was rCR (FNR 47%; OR 9.81, 95% CI 1.72-55.89; p = 0.01); a trend was observed for HR-negative tumors (FNR 71% in HER2-positive and 55% in triple-negative tumors; OR 4.55, 95% CI 0.95-21.73; p = 0.058) and smaller pathological lesions (6 mm vs 15 mm; OR 0.93, 95% CI 0.87-1.00; p = 0.051). CONCLUSION: The MICRA trial showed that ultrasound-guided core biopsies are not accurate enough to identify breast pCR in patients with good response on MRI after NST. Therefore, breast surgery cannot safely be omitted relying on the results of core biopsies in these patients.
Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Humanos , Mastectomia , Estudos Prospectivos , Receptor ErbB-2 , Resultado do TratamentoRESUMO
PURPOSE: BRCA2 mutation carriers are offered annual breast screening with MRI and mammography. The aim of this study was to investigate the supplemental value of mammographic screening over MRI screening alone. METHODS: In this multicenter study, proven BRCA2 mutation carriers, who developed breast cancer during screening using both digital mammography and state-of-art breast MRI, were identified. Clinical data were reviewed to classify cases in screen-detected and interval cancers. Imaging was reviewed to assess the diagnostic value of mammography and MRI, using the Breast Imaging and Data System (BI-RADS) classification allocated at the time of diagnosis. RESULTS: From January 2003 till March 2019, 62 invasive breast cancers and 23 ductal carcinomas in situ were diagnosed in 83 BRCA2 mutation carriers under surveillance. Overall screening sensitivity was 95.2% (81/85). Four interval cancers occurred (4.7% (4/85)). MRI detected 73 of 85 breast cancers (sensitivity 85.8%) and 42 mammography (sensitivity 49.9%) (p < 0.001). Eight mammography-only lesions occurred. In 1 of 17 women younger than 40 years, a 6-mm grade 3 DCIS, retrospectively visible on MRI, was detected with mammography only in a 38-year-old woman. The other 7 mammography-only breast cancers were diagnosed in women aged 50 years and older, increasing sensitivity in this subgroup from 79.5% (35/44) to 95.5% (42/44) (p ≤ 0.001). CONCLUSIONS: In BRCA2 mutation carriers younger than 40 years, the benefit of mammographic screening over MRI was very small. In carriers of 50 years and older, mammographic screening contributed significantly. Hence, we propose to postpone mammographic screening in BRCA2 mutation carriers to at least age 40.
Assuntos
Proteína BRCA2/genética , Neoplasias da Mama/diagnóstico , Carcinoma Intraductal não Infiltrante/diagnóstico , Detecção Precoce de Câncer/métodos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mutação , Adulto , Neoplasias da Mama/genética , Carcinoma Intraductal não Infiltrante/genética , Feminino , Seguimentos , Heterozigoto , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos RetrospectivosRESUMO
BACKGROUND: Despite increasingly effective curative breast-conserving treatment (BCT) regimens for primary breast cancer, patients remain at risk for an ipsilateral breast tumor recurrence (IBTR). With increasing interest for repeat BCT in selected patients with IBTR, a reliable assessment of the size of IBTR is important for surgical planning. AIM: The primary aim of this study is to establish the performance in size estimation of XMG, US, and breast MRI in patients with IBTR. The secondary aim is to compare the detection of multifocality and contralateral lesions between XMG and MRI. PATIENTS AND METHODS: The sizes of IBTR on mammography (XMG), ultrasound (US), and magnetic resonance imaging (MRI) in 159 patients were compared to the sizes at final histopathology. The accuracy of the size estimates was addressed using Pearson's coefficient and Bland-Altman plots. Secondary outcomes were the detection of multifocality and contralateral lesions between XMG and MRI. RESULTS: Both XMG and US significantly underestimated the tumor size by 3.5 and 4.8 mm, respectively, while MRI provided accurate tumor size estimation with a mean underestimation of 1.1 mm. The sensitivity for the detection of multifocality was significantly higher for MRI compared to XMG (25.5% vs. 5.5%). A contralateral malignancy was found in 4.4% of patients, and in 1.9%, it was detected by MRI only. CONCLUSION: The addition of breast MRI to XMG and US in the preoperative workup of IBTR allows for more accurate size estimation. MRI provides a higher sensitivity for the detection of multifocality compared to XMG.
Assuntos
Neoplasias da Mama , Recidiva Local de Neoplasia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Mastectomia Segmentar , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Ultrassonografia MamáriaRESUMO
Background Better understanding of the molecular biology associated with MRI phenotypes may aid in the diagnosis and treatment of breast cancer. Purpose To discover the associations between MRI phenotypes of breast cancer and their underlying molecular biology derived from gene expression data. Materials and Methods This is a secondary analysis of the Multimodality Analysis and Radiologic Guidance in Breast-Conserving Therapy, or MARGINS, study. MARGINS included patients eligible for breast-conserving therapy between November 2000 and December 2008 for preoperative breast MRI. Tumor RNA was collected for sequencing from surgical specimen. Twenty-one computer-generated MRI features of tumors were condensed into seven MRI factors related to tumor size, shape, initial enhancement, late enhancement, smoothness of enhancement, sharpness, and sharpness variation. These factors were associated with gene expression levels from RNA sequencing by using gene set enrichment analysis. Statistical significance of these associations was evaluated by using a sample permutation test and the false discovery rate. Results Gene expression and MRI data were obtained for 295 patients (mean age, 56 years ± 10.3 [standard deviation]). Larger and more irregular tumors showed increased expression of cell cycle and DNA damage checkpoint genes (false discovery rate <0.25; normalized enrichment statistic [NES], 2.15). Enhancement and sharpness of the tumor margin were associated with expression of ribosomal proteins (false discovery rate <0.25; NES, 1.95). Smoothness of enhancement, tumor size, and tumor shape were associated with expression of genes involved in the extracellular matrix (false discovery rate <0.25; NES, 2.25). Conclusion Breast cancer MRI phenotypes were related to their underlying molecular biology revealed by using RNA sequencing. The association between enhancements and sharpness of the tumor margin with the ribosome suggests that these MRI features may be imaging biomarkers for drugs targeting the ribosome. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Cho in this issue.
Assuntos
Neoplasias da Mama , Genômica por Imageamento/classificação , Imageamento por Ressonância Magnética/classificação , Transcriptoma/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Mama/metabolismo , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , FenótipoRESUMO
BACKGROUND: Previous studies have shown discrepancies between index and synchronous breast cancer in histology and molecular phenotype. It is yet unknown whether this observation also applies to the MRI phenotype. PURPOSE: To investigate whether the appearance of breast cancer on MRI (i.e. phenotype) is different from that of additional breast cancer (i.e. synchronous cancer), and whether such a difference, if it exists, is associated with prognosis. STUDY TYPE: Retrospective. POPULATION: In all, 464 consecutive patients with early-stage ER+/HER2- breast cancer were included; 34/464 (7.3%) had 44 synchronous cancers in total (34 ipsilateral, 10 contralateral). SEQUENCE: 1.5T, contrast-enhanced T1 -weighted. ASSESSMENT: We assessed imaging phenotype using 50 quantitative features from each cancer and applied principal component analysis (PCA) to identify independent properties. The degree of phenotype difference was assessed. An association between phenotype differences and prognosis in terms of the Nottingham Prognostic Index (NPI) and PREDICT score were analyzed. STATISTICAL TESTS: PCA; Wilcoxon rank sum test; Benjamini-Hochberg to control the false discovery rate. RESULTS: PCA identified eight components in patients with ipsilateral synchronous cancer. Six out of eight were significantly different between index and synchronous cancer. These components represented features describing texture (three components, P < 0.001, P < 0.001, P = 0.004), size (P < 0.001), smoothness (P < 0.001), and kinetics (P = 0.004). Phenotype differences in terms of the six components were split in tertiles. Larger phenotype differences in size, kinetics, and texture were associated with significantly worse prognosis in terms of NPI (P = 0.019, P = 0.045, P = 0.014), but not for the PREDICT score (P = 0.109, P = 0.479, P = 0.109). PCA identified six components in patients with contralateral synchronous cancer. None were significantly different from the index cancer (P = 0.178, P = 0.178, P = 0.178, P = 0.326, P = 0.739, P = 0.423). DATA CONCLUSION: The MRI phenotype of ER+/HER2- breast cancer was different from that of ipsilateral synchronous cancer and a large phenotype difference was associated with worse prognosis. No significant difference was found for synchronous contralateral cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2020;51:1858-1867.
Assuntos
Neoplasias da Mama , Mama , Neoplasias da Mama/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Fenótipo , Prognóstico , Estudos RetrospectivosRESUMO
BACKGROUND: Differences in imaging parameters influence computer-extracted parenchymal enhancement measures from breast MRI. PURPOSE: To investigate the effect of differences in dynamic contrast-enhanced MRI acquisition parameter settings on quantitative parenchymal enhancement of the breast, and to evaluate harmonization of contrast-enhancement values with respect to flip angle and repetition time. STUDY TYPE: Retrospective. PHANTOM/POPULATIONS: We modeled parenchymal enhancement using simulations, a phantom, and two cohorts (N = 398 and N = 302) from independent cancer centers. SEQUENCE FIELD/STRENGTH: 1.5T dynamic contrast-enhanced T1 -weighted spoiled gradient echo MRI. Vendors: Philips, Siemens, General Electric Medical Systems. ASSESSMENT: We assessed harmonization of parenchymal enhancement in simulations and phantom by varying the MR parameters that influence the amount of T1 -weighting: flip angle (8°-25°) and repetition time (4-12 msec). We calculated the median and interquartile range (IQR) of the enhancement values before and after harmonization. In vivo, we assessed overlap of quantitative parenchymal enhancement in the cohorts before and after harmonization using kernel density estimations. Cohort 1 was scanned with flip angle 20° and repetition time 8 msec; cohort 2 with flip angle 10° and repetition time 6 msec. STATISTICAL TESTS: Paired Wilcoxon signed-rank-test of bootstrapped kernel density estimations. RESULTS: Before harmonization, simulated enhancement values had a median (IQR) of 0.46 (0.34-0.49). After harmonization, the IQR was reduced: median (IQR): 0.44 (0.44-0.45). In the phantom, the IQR also decreased, median (IQR): 0.96 (0.59-1.22) before harmonization, 0.96 (0.91-1.02) after harmonization. Harmonization yielded significantly (P < 0.001) better overlap in parenchymal enhancement between the cohorts: median (IQR) was 0.46 (0.37-0.58) for cohort 1 vs. 0.37 (0.30-0.44) for cohort 2 before harmonization (57% overlap); and 0.35 (0.28-0.43) vs. .0.37 (0.30-0.44) after harmonization (85% overlap). DATA CONCLUSION: The proposed practical harmonization method enables an accurate comparison between patients scanned with differences in imaging parameters. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 4.
Assuntos
Mama , Imageamento por Ressonância Magnética , Mama/diagnóstico por imagem , Humanos , Aumento da Imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
OBJECTIVES: To investigate whether contralateral parenchymal enhancement (CPE) on MRI during neoadjuvant endocrine therapy (NET) is associated with the preoperative endocrine prognostic index (PEPI) of ER+/HER2- breast cancer. METHODS: This retrospective observational cohort study included 40 unilateral ER+/HER2- breast cancer patients treated with NET. Patients received NET for 6 to 9 months with MRI response monitoring after 3 and/or 6 months. PEPI was used as endpoint. PEPI is based on surgery-derived pathology (pT- and pN-stage, Ki67, and ER-status) and stratifies patients in three groups with distinct prognoses. Mixed effects and ROC analysis were performed to investigate whether CPE was associated with PEPI and to assess discriminatory ability. RESULTS: The median patient age was 61 (interquartile interval: 52, 69). Twelve patients had PEPI-1 (good prognosis), 15 PEPI-2 (intermediate), and 13 PEPI-3 (poor). High pretreatment CPE was associated with PEPI-3: pretreatment CPE was 39.4% higher on average (95% CI = 1.3, 91.9%; p = .047) compared with PEPI-1. CPE decreased after 3 months in PEPI-2 and PEPI-3. The average reduction was 24.4% (95% CI = 2.6, 41.3%; p = .032) in PEPI-2 and 29.2% (95% CI = 7.8, 45.6%; p = .011) in PEPI-3 compared with baseline. Change in CPE was predictive of PEPI-1 vs PEPI-2+3 (AUC = 0.77; 95% CI = 0.57, 0.96). CONCLUSIONS: CPE during NET is associated with PEPI-group in ER+/HER2- breast cancer: a high pretreatment CPE and a decrease in CPE during NET were associated with a poor prognosis after NET on the basis of PEPI. KEY POINTS: ⢠Change in contralateral breast parenchymal enhancement on MRI during neoadjuvant endocrine therapy distinguished between patients with a good and intermediate/poor prognosis at final pathology. ⢠Patients with a poor prognosis at final pathology showed higher baseline parenchymal enhancement on average compared to patients with a good prognosis. ⢠Patients with an intermediate/poor prognosis at final pathology showed a higher average reduction in parenchymal enhancement after 3 months of neoadjuvant endocrine therapy.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Adulto , Idoso , Mama/patologia , Sistema Endócrino , Feminino , Humanos , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: To analyze the feasibility and accuracy of micro-computed tomography (micro-CT) for surgical margin assessment in breast excision specimen. MATERIALS AND METHODS: Two data sets of 30 micro-CT scans were retrospectively evaluated for positive resection margins by four observers in two phases, using pathology as a gold standard. Results of phase 1 were evaluated to define micro-CT evaluation guidelines for phase 2. Interobserver agreement was also assessed (kappa). In addition, a prospective study was conducted in which 40 micro-CT scans were directly acquired, reconstructed, and evaluated for positive resection margins by one observer. A suspect positive resection margin on micro-CT was annotated onto the specimen with ink, enabling local validation by pathology. Main outcome measures were accuracy, sensitivity, specificity, and positive predictive value (PPV). RESULTS: Average accuracy, sensitivity, specificity, and PPV for the four observers were 63%, 38%, 70%, and 22%, respectively, in phase 1 and 72%, 40%, 78%, and 26%, respectively, in phase 2. The interobserver agreement was fair [kappa (range), 0.31 (0.12-0.80) in phase 1 and 0.23 (0-0.43) in phase 2]. In the prospective study 70% of the surgical resection margins were correctly evaluated. Ten specimens were annotated for positive resection margins, which correlated with three positive and three close (<1 mm) margins on pathology. Sensitivity, specificity, and PPV were 38%, 78%, and 30%, respectively. CONCLUSIONS: Micro-CT imaging of breast excision specimen has moderate accuracy and considerable interobserver variation for analysis of surgical resection margins. Especially sensitivity and PPV need to be improved before micro-CT-based margin assessment can be introduced in clinical practice.
Assuntos
Neoplasias da Mama/cirurgia , Mama/diagnóstico por imagem , Margens de Excisão , Mastectomia Segmentar , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Países Baixos , Variações Dependentes do Observador , Período Pós-Operatório , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade , Microtomografia por Raio-XRESUMO
BACKGROUND: Breast cancer surgeons struggle with differentiating healthy tissue from cancer at the resection margin during surgery. We report on the feasibility of using diffuse reflectance spectroscopy (DRS) for real-time in vivo tissue characterization. METHODS: Evaluating feasibility of the technology requires a setting in which measurements, imaging and pathology have the best possible correlation. For this purpose an optical biopsy needle was used that had integrated optical fibers at the tip of the needle. This approach enabled the best possible correlation between optical measurement volume and tissue histology. With this optical biopsy needle we acquired real-time DRS data of normal tissue and tumor tissue in 27 patients that underwent an ultrasound guided breast biopsy procedure. Five additional patients were measured in continuous mode in which we obtained DRS measurements along the entire biopsy needle trajectory. We developed and compared three different support vector machine based classification models to classify the DRS measurements. RESULTS: With DRS malignant tissue could be discriminated from healthy tissue. The classification model that was based on eight selected wavelengths had the highest accuracy and Matthews Correlation Coefficient (MCC) of 0.93 and 0.87, respectively. In three patients that were measured in continuous mode and had malignant tissue in their biopsy specimen, a clear transition was seen in the classified DRS measurements going from healthy tissue to tumor tissue. This transition was not seen in the other two continuously measured patients that had benign tissue in their biopsy specimen. CONCLUSIONS: It was concluded that DRS is feasible for integration in a surgical tool that could assist the breast surgeon in detecting positive resection margins during breast surgery. Trail registration NIH US National Library of Medicine-clinicaltrails.gov, NCT01730365. Registered: 10/04/2012 https://clinicaltrials.gov/ct2/show/study/NCT01730365.