Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38924288

RESUMO

INTRODUCTION: Access site complications remain common following atrial fibrillation (AF) catheter ablation. Femoral vascular closure devices (VCDs) reduce time to hemostasis compared with manual compression, although large-scale data comparing clinical outcomes between the two approaches are lacking. METHODS: Two cohorts of patients undergoing AF ablation were identified from 36 healthcare organizations using a global federated research network (TriNetX): those receiving a VCD for femoral hemostasis, and those not receiving a VCD. A 1:1 propensity score matching (PSM) model based on baseline characteristics was used to create two comparable cohorts. The primary outcome was a composite of all-cause mortality, vascular complications, bleeding events, and need for blood transfusion. Outcomes were assessed during early (within 7 days of ablation) and extended follow-up (within 8-30 days of ablation). RESULTS: After PSM, 28 872 patients were included (14 436 in each cohort). The primary composite outcome occurred less frequently in the VCD cohort during early (1.97% vs. 2.60%, odds ratio (OR) 0.76, 95% confidence interval (CI) 0.65-0.88; p < .001) and extended follow-up (1.15% vs. 1.43%, OR 0.80, 95% CI 0.65-0.98; p = .032). This was driven by a lower rate of vascular complications during early follow-up in the VCD cohort (0.83% vs. 1.26%, OR 0.66, 95% CI 0.52-0.83; p < .001), and fewer bleeding events during early (0.90% vs. 1.23%, OR 0.73, 95% CI 0.58-0.92; p = .007) and extended follow-up (0.36% vs. 0.59%, OR 0.61, 95% CI 0.43-0.86; p = .005). CONCLUSION: Following AF ablation, femoral venous hemostasis with a VCD was associated with reduced complications compared with hemostasis without a VCD.

2.
J Cardiovasc Electrophysiol ; 35(6): 1165-1173, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571287

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is often performed under general anaesthesia (GA) or deep sedation. Anaesthetic availability is limited in many centers, and deep sedation is prohibited in some countries without anaesthetic support. Very high-power short duration (vHPSD-90W/4 s) PVI using the Q-Dot catheter is generally well tolerated under mild conscious sedation (MCS) though an understanding of catheter stability and long-term effectiveness is lacking. We analyzed lesion metrics and 12-month freedom from atrial arrythmia with this approach. METHODS: Our approach to radiofrequency (RF) PVI under MCS is standardized and includes a single catheter approach with a steerable sheath. We identified patients undergoing Q-Dot RF PVI between March 2021 and December 2022 in our center, comparing those undergoing vHPSD ablation under MCS (90W/MCS) against those undergoing 50 W ablation under GA (50 W/GA) up to 12 months of follow-up. Data were extracted from clinical records and the CARTO system. RESULTS: Eighty-three patients met our inclusion criteria (51 90W/MCS; 32 50 W/GA). Despite shorter ablation times (353 vs. 886 s; p < .001), the 90 W/MCS group received more lesions (median 87 vs. 58, p < .001), resulting in similar procedure times (149.3 vs. 149.1 min; p = .981). PVI was achieved in all cases, and first pass isolation rates were similar (left wide antral circumferential ablation [WACA] 82.4% vs. 87.5%, p = .758; right WACA 74.5% vs. 78.1%, p = .796; 90 W/MCS vs. 50 W/GA respectively). Analysis of 6647 ablation lesions found similar mean impedance drops (10.0 ± 1.9 Ω vs. 10.0 ± 2.2 Ω; p = .989) and mean contact force (14.6 ± 2.0 g vs. 15.1 ± 1.6 g; p = .248). Only median 2.5% of lesions in the 90 W/MCS cohort failed to achieve ≥ 5 Ω drop. In the 90 W/MCS group, there were no procedural related complications, and 12-month freedom from atrial arrhythmia was observed in 78.4%. CONCLUSION: vHPSD PVI is feasible under MCS, with encouraging acute and long-term procedural outcomes. This provides a compelling option for centers with limited anaesthetic support.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Sedação Consciente , Frequência Cardíaca , Veias Pulmonares , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fatores de Tempo , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Cateteres Cardíacos , Intervalo Livre de Progressão , Fatores de Risco
3.
J Cardiovasc Electrophysiol ; 34(3): 664-672, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36478627

RESUMO

BACKGROUND: Ventricular scar is traditionally highlighted on a bipolar voltage (BiVolt) map in areas of myocardium <0.50 mV. We describe an alternative approach using Ripple Mapping (RM) superimposed onto a BiVolt map to differentiate postinfarct scar from conducting borderzone (BZ) during ventricular tachycardia (VT) ablation. METHODS: Fifteen consecutive patients (left ventricular ejection fraction 30 ± 7%) underwent endocardial left ventricle pentaray mapping (median 5148 points) and ablation targeting areas of late Ripple activation. BiVolt maps were studied offline at initial voltage of 0.50-0.50 mV to binarize the color display (red and purple). RMs were superimposed, and the BiVolt limits were sequentially reduced until only areas devoid of Ripple bars appeared red, defined as RM-scar. The surrounding area supporting conducting Ripple wavefronts in tissue <0.50 mV defined the RM-BZ. RESULTS: RM-scar was significantly smaller than the traditional 0.50 mV cutoff (median 4% vs. 12% shell area, p < .001). 65 ± 16% of tissue <0.50 mV supported Ripple activation within the RM-BZ. The mean BiVolt threshold that differentiated RM-scar from BZ tissue was 0.22 ± 0.07 mV, though this ranged widely (from 0.12 to 0.35 mV). In this study, septal infarcts (7/15) were associated with more rapid VTs (282 vs. 347 ms, p = .001), and had a greater proportion of RM-BZ to RM-scar (median ratio 3.2 vs. 1.2, p = .013) with faster RM-BZ conduction speed (0.72 vs. 0.34 m/s, p = .001). Conversely, scars that supported hemodynamically stable sustained VT (6/15) were slower (367 ± 38 ms), had a smaller proportion of RM-BZ to RM-scar (median ratio 1.2 vs. 3.2, p = .059), and slower RM-BZ conduction speed (0.36 vs. 0.63 m/s, p = .036). RM guided ablation collocated within 66 ± 20% of RM-BZ, most concentrated around the RM-scar perimeter, with significant VT reduction (median 4.0 episodes preablation vs. 0 post, p < .001) at 11 ± 6 months follow-up. CONCLUSION: Postinfarct scars appear significantly smaller than traditional 0.50 mV cut-offs suggest, with voltage thresholds unique to each patient.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Volume Sistólico , Técnicas Eletrofisiológicas Cardíacas , Função Ventricular Esquerda
4.
Europace ; 23(6): 878-886, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33693677

RESUMO

AIMS: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. METHODS AND RESULTS: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35-40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35-40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions (n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35-40 W groups, respectively (P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). CONCLUSION: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 29(3): 404-411, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29341322

RESUMO

BACKGROUND: Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. METHODS: We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. RESULTS: Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). CONCLUSIONS: The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 28(11): 1285-1294, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28776822

RESUMO

BACKGROUND: Ripple mapping (RM) displays electrograms as moving bars over a three-dimensional surface displaying bipolar voltage, and has shown in a single-center series to be effective for atrial tachycardia (AT) mapping without annotation of local activation time or window-of-interest assignment. We tested the reproducibility of these findings in operators naïve to RM, using it for the first time in postablation AT. METHODS: Maps were collected with multielectrode catheters and CARTO ConfiDENSE. A diagnosis of the tachycardia mechanism was made using RM and an assessment of operator confidence was made according to a three-grade scale (1 highest-3 lowest). RESULTS: The first 20 patients (64 ± 9 years, median two previous ablations) undergoing RM-guided AT ablation across five sites were studied. High-density maps (2,935 ± 1,328 points) in AT (CL = 296 ± 95 milliseconds) were collected. Macroreentrant ATs bordered by scar or anatomical obstacles were identified in n = 12 (60%), small reentrant ATs around scar in n = 3 (15%), and focal ATs from scar in n = 5 (25%). Diagnostic confidence with RM was grade 1 in n = 13 (65%), where operators felt confident to proceed to ablation without entrainment. Ablation offered the correct diagnosis n = 18 (90%). Retrospective review of the accompanying LAT maps demonstrated potential sources for error related to the window of interest selection, interpolation, and differentiating regions of scar during tachycardia on the voltage map. CONCLUSION: RM was easy to adopt by operators using it for the first time, and identified the correct target for ablation with high diagnostic confidence in most cases of complex AT.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Adulto , Idoso , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
8.
J Cardiovasc Electrophysiol ; 28(12): 1445-1453, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28833757

RESUMO

INTRODUCTION: We hypothesized that very high-density mapping of typical atrial flutter (AFL) would facilitate a more complete understanding of its circuit. Such very high-density mapping was performed with the RhythmiaTM (Boston Scientific) mapping system using its 64 electrode basket catheter. METHODS AND RESULTS: Data were acquired from 13 patients in AFL. Functional anatomy of the right atrium (RA) was readily identified during mapping including the Crista Terminalis and Eustachian ridge. The leading edge of the activation wavefront was identified without interruption and its conduction velocity (CV) was calculated. CV was not different at the cavotricuspid isthmus (CTI) compared to the remainder of the RA (1.02 vs. 1.03 m/s, P = 0.93). The sawtooth pattern of the surface electrocardiogram (EKG) flutter waves was compared to the position of the dominant wavefront. The downslope of the surface EKG flutter waves represented on average 73% ± 9% of the total flutter cycle length. During the downslope, the activation wavefront traveled significantly further than during the upslope (182 ± 21 milliseconds vs. 68 ± 29 milliseconds, P < 0.0001) with no change in CV between the two phases (0.88 vs. 0.91 m/s, P = 0.79). CONCLUSION: CV at the CTI is not slower than other RA regions during typical AFL. The gradual downslope of the sawtooth EKG  is not due to slow conduction at the CTI suggesting that success of ablation at this site relates to anatomical properties rather than the presence of a "slow isthmus."


Assuntos
Flutter Atrial/fisiopatologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Valva Tricúspide/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
9.
Heart Rhythm ; 21(1): 45-53, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38176771

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) represents a valuable image integration technique, with the unique advantage of dynamic real-time scar characterization. OBJECTIVES: The goals of this study were to assess the correlation between ICE-defined and electroanatomic mapping (EAM)-defined scar in patients with ischemic cardiomyopathy and to define the outcomes of ICE-guided ventricular tachycardia (VT) ablation. METHODS: Thirty-eight patients with ischemic cardiomyopathy (SOUNDSCAR cohort) underwent full left ventricular (LV) ICE imaging and EAM. ICE-defined scar parameters (end-diastolic and end-systolic wall diameter [EDWD and ESWD], end-systolic wall thickening [percentage difference between EDWD and ESWD with respect to EDWD], slope [end-diastole to end-systole wall thickening], and American Heart Association wall motion scoring) were correlated with EAM-defined scar (voltage <1.5 mV). In a separate cohort (n = 21), outcomes of an ICE-guided VT ablation approach (EAM focused to ICE-defined scar regions) were compared with those of conventional ablation (full left ventricular mapping with EAM only; n = 21). RESULTS: In the 38 SOUNDSCAR patients (mean age 67 ± 11 years; 35 male [92%]; left ventricular ejection fraction 31% ± 10%; 2474 ICE segments; 524 ICE sectors), all ICE-defined parameters strongly predicted EAM-defined scar (area under the curve: American Heart Association score 0.873; ESWD 0.880; EDWD 0.827; slope 0.855; percentage difference between EDWD and ESWD with respect to EDWD, 0.851). All ICE-defined parameters had large effect sizes for predicting EAM-defined scar (logistic regression, P < .001). A detailed topographical comparison of ICE-defined (slope) and EAM-defined scar was possible in 25 patients and demonstrated 88% ± 10% overlap. Compared with conventional VT ablation, ICE-guided ablation was associated with shorter procedure times and comparable VT-free survival (ICE-guided vs conventional: procedure time 240 ± 20 minutes vs 298 ± 39 minutes; P < .001; VT recurrence 3 [14%] vs 7 [31%]; P = .19). CONCLUSION: ICE-defined scar demonstrates a strong correlation with EAM-defined scar. ICE-guided VT ablation is associated with enhanced procedural efficiency.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Volume Sistólico , Função Ventricular Esquerda , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Ventrículos do Coração , Isquemia Miocárdica/complicações , Cardiomiopatias/complicações , Ablação por Cateter/métodos , Resultado do Tratamento , Cicatriz/etiologia , Cicatriz/complicações
10.
J Arrhythm ; 40(3): 501-507, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38939768

RESUMO

Background: Patients who have recurrent atrial fibrillation (AF) following redo catheter ablation may eventually be managed with a pace-and-ablate approach, involving pacemaker implant followed by atrioventricular nodal ablation (AVNA). We sought to determine which factors would predict subsequent AVNA in patients undergoing redo AF ablation. Methods: We analyzed patients undergoing redo AF ablations between 2013 and 2019 at our institution. Follow-up was censored on December 31, 2021. Patients with no available follow-up data were excluded. Time-to-event analysis with Cox proportional hazard regression was used to compare those who underwent AVNA to those who did not. Results: A total of 467 patients were included, of whom 39 (8.4%) underwent AVNA. After multivariable adjustment, female sex (aHR 4.68 [95% CI 2.30-9.50]; p < 0.001), ischemic heart disease (aHR 2.99 [95% CI 1.25-7.16]; p = 0.014), presence of a preexisting pacemaker (aHR 3.25 [95% CI 1.10-9.60]; p = 0.033), and persistent AF (aHR 2.22 [95% CI 1.07-4.59]; p = 0.032) were associated with increased risk of subsequent AVNA requirement. Conclusion: Female sex, ischemic heart disease, and persistent AF may be useful clinical predictors of the requirement for subsequent AVNA and may be considered as part of shared clinical decision making.

11.
Heart Rhythm ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38763378

RESUMO

BACKGROUND: With the exponential growth of catheter ablation for atrial fibrillation (AF), there is increasing interest in associated health care costs. Pulsed field ablation (PFA) using a single-shot pentaspline multielectrode catheter has been shown to be safe and effective for AF ablation, but its cost efficiency compared to conventional thermal ablation modalities (cryoballoon [CB] or radiofrequency [RF]) has not been evaluated. OBJECTIVE: The purpose of this study was to compare cost, efficiency, effectiveness, and safety between PFA, CB, and RF for AF ablation. METHODS: We studied 707 consecutive patients (PFA: 208 [46.0%]; CB: 325 [29.4%]; RF: 174 [24.6%]) undergoing first-time AF ablation. Individual procedural costs were calculated, including equipment, laboratory use, and hospital stay, and compared between ablation modalities, as were effectiveness and safety. RESULTS: Skin-to-skin times and catheter laboratory times were significantly shorter with PFA (68 and 102 minutes, respectively) than with CB (91 and 122 minutes) and RF (89 and 123 minutes) (P < .001). General anesthesia use differed across modalities (PFA 100%; CB 10.2%; RF 61.5%) (P < .001). Major complications occurred in 1% of cases, with no significant differences between modalities. Shorter procedural times resulted in lower staffing and laboratory costs with PFA, but these savings were offset by substantially higher equipment costs, resulting in higher overall median costs with PFA (£10,010) than with CB (£8106) and RF (£8949) (P < .001). CONCLUSION: In this contemporary real-world study of the 3 major AF ablation modalities used concurrently, PFA had shorter skin-to-skin and catheter laboratory times than did CB and RF, with similarly low rates of complications. However, PFA procedures were considerably more expensive, largely because of higher equipment cost.

12.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636929

RESUMO

BACKGROUND: No study has assessed the durability of pulmonary vein isolation (PVI) with radiofrequency (RF) and cryoballoon (CB) in patients with persistent atrial fibrillation. These data are especially lacking for those with significantly diseased left atria (LA). OBJECTIVES: The goals of this study were to assess PVI durability in patients with significant LA disease and to compare reconnection rates between RF and CB. METHODS: Forty-four patients (mean age 63 years; 34 (77%) male; median time since atrial fibrillation diagnosis 22.5 months; median indexed LA volume 36 mL/m2) were randomized 1:1 to RF or CB PVI. A redo procedure using ultra-high-density electroanatomic mapping was mandated at 2 months, where PV reconnections were identified and reisolated. RESULTS: Thirty-eight patients underwent both procedures (CB n = 17; RF n = 21). Index RF procedures were longer (median 158 minutes vs 97 minutes; P < .001) but required less fluoroscopy (9.5 minutes vs 23 minutes; P < .001). At the index RF procedure, a median of 47% of LA myocardium had voltage < 0.5 mV, suggesting that half of the mapped LA comprised scar. PV reconnection was observed in 73 of 152 PVs (48.0%) and was more frequent with CB (58.8%) than with RF (39.3%) (P = .022). Reconnection of at least 1 PV was detected in >75% of patients. Significantly more ablation was required during the redo procedure to reisolate PVs in the CB arm (median 10.8 minutes vs 1.2 minutes; P < .001). CONCLUSION: PVI durability may be poor in those with significant LA scarring and dilatation, even with modern thermal ablation technologies. RF resulted in significantly better PVI durability than did CB in this complex population. TRIAL REGISTRATION: clinicaltrials.gov identifier: NCT04111731.

13.
Heart Rhythm O2 ; 5(4): 224-233, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690145

RESUMO

Background: Defining postinfarct ventricular arrhythmic substrate is challenging with voltage mapping alone, though it may be improved in combination with an activation map. Omnipolar technology on the EnSite X system displays activation as vectors that can be superimposed onto a voltage map. Objective: The study sought to optimize voltage map settings during ventricular tachycardia (VT) ablation, adjusting them dynamically using omnipolar vectors. Methods: Consecutive patients undergoing substrate mapping were retrospectively studied. We categorized omnipolar vectors as uniform when pointing in one direction, or in disarray when pointing in multiple directions. We superimposed vectors onto voltage maps colored purple in tissue >1.5 mV, and the voltage settings were adjusted so that uniform vectors appeared within purple voltages, a process termed dynamic voltage mapping (DVM). Vectors in disarray appeared within red-blue lower voltages. Results: A total of 17 substrate maps were studied in 14 patients (mean age 63 ± 13 years; mean left ventricular ejection fraction 35 ± 6%, median 4 [interquartile range 2-8.5] recent VT episodes). The DVM mean voltage threshold that differentiated tissue supporting uniform vectors from disarray was 0.27 mV, ranging between patients from 0.18 to 0.50 mV, with good interobserver agreement (median difference: 0.00 mV). We found that VT isthmus components, as well as sites of latest activation, isochronal crowding, and excellent pace maps colocated with tissue along the DVM border zone surrounding areas of disarray. Conclusion: DVM, guided by areas of omnipolar vector disarray, allows for individualized postinfarct ventricular substrate characterization. Tissue bordering areas of disarray may harbor greater arrhythmogenic potential.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38261098

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Despite promising success rates, redo ablation is sometimes required. At redo, PVs may be found to be isolated (silent) or reconnected. We studied patients with silent vs reconnected PVs at redo and analysed associations with adverse outcomes. METHODS: Patients undergoing redo AF ablations between 2013 and 2019 at our institution were included and stratified into silent PVs or reconnected PVs. The primary outcome was a composite of further redo ablation, non-AF ablation, atrioventricular nodal ablation, and death. Secondary outcomes included arrhythmia recurrence. RESULTS: A total of 467 patients were included with mean 4.6 ± 1.7 years follow-up, of whom 48 (10.3%) had silent PVs. The silent PV group had had more often undergone >1 prior ablation (45.8% vs 9.8%; p<0.001), had more persistent AF (62.5% vs 41.1%; p=0.005) and had more non-PV ablation performed both at prior ablation procedures and at the analysed redo ablation. The primary outcome occurred more frequently in those with silent PVs (25% vs 13.8%; p=0.053). Arrhythmia recurrence was also more common in the silent PV group (66.7% vs 50.6%; p=0.047). After multivariable adjustment, female sex (aHR 2.35 [95% CI 2.35-3.96]; p=0.001) and ischaemic heart disease (aHR 3.21 [95% CI 1.56-6.62]; p=0.002) were independently associated with the primary outcome, and left atrial enlargement (aHR 1.58 [95% CI 1.20-2.08]; p=0.001) and >1 prior ablation (aHR 1.88 [95% CI 1.30-2.72]; p<0.001) were independently associated with arrhythmia recurrence. Whilst a finding of silent PVs was not itself significant after multivariable adjustment, this provides an easily assessable parameter at clinically indicated redo ablation which informs the clinician of the likelihood of a worse future prognosis. CONCLUSIONS: Patients with silent PVs at redo AF ablation have worse clinical outcomes.

15.
Heart Rhythm ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38848856

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden. OBJECTIVE: The study aimed to limit ablation within postinfarction scar to conduction channels within the scar to reduce VT recurrence. METHODS: Patients undergoing catheter ablation for recurrent implantable cardioverter-defibrillator therapy for postinfarction VT were recruited at 5 centers. Left ventricular maps were collected on CARTO using a Pentaray catheter. Ripple mapping was used to categorize infarct scar potentials (SPs) by timing. Earliest SPs were ablated sequentially until there was loss of the terminal SPs without their direct ablation. The primary outcome measure was sustained VT episodes as documented by device interrogations at 1 year, which was compared with VT episodes in the year before ablation. RESULTS: The study recruited 50 patients (mean left ventricular ejection fraction, 33% ± 9%), and 37 patients (74%) met the channel ablation end point with successful loss of latest SPs without direct ablation. There were 16 recurrences during 1-year follow-up. There was a 90% reduction in VT burden from 30.2 ± 53.9 to 3.1 ± 7.5 (P < .01) per patient, with a concomitant 88% reduction in appropriate shocks from 2.1 ± 2.7 to 0.2 ± 0.9 (P < .01). There were 8 deaths during follow-up. Those who met the channel ablation end point had no significant difference in mortality, recurrence, or VT burden but had a significantly lower ablation burden of 25.7 ± 4.2 minutes vs 39.9 ± 6.1 minutes (P = .001). CONCLUSION: Scar channel ablation is feasible by ripple mapping and can be an alternative to more extensive substrate modification techniques.

16.
Heart Rhythm ; 21(5): 571-580, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286246

RESUMO

BACKGROUND: Three-dimensional (3D) mapping of the ventricular conduction system is challenging. OBJECTIVE: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV). METHODS: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation. Ripple maps were viewed from the end of the P wave to QRS onset in 1-ms increments. Clusters of >3 ripple bars were interrogated for the presence of Purkinje potentials, which were tagged on the 3D geometry. Repeating this process allowed conduction system delineation. RESULTS: Maps were reviewed in 24 patients (mean 3112 ± 613 points). There were 150.9 ± 24.5 Purkinje potentials per map, at the left posterior fascicle (LPF) in 22 patients (92%) and at the left anterior fascicle (LAF) in 15 patients (63%). The LAF was shorter (41.4 vs 68.8 mm; P = .0005) and activated for a shorter duration (40.6 vs 64.9 ms; P = .002) than the LPF. Fourteen of 24 patients had left bundle branch block (LBBB), with 11 of 14 (78%) having Purkinje potential-associated breakout. There were fewer breakouts from the conduction system during LBBB (1.8 vs 3.4; 1.6 ± 0.6; P = .039) and an inverse correlation between breakout sites and QRS duration (P = .0035). CONCLUSION: We applied ripple mapping to present a detailed electroanatomic characterization of the conduction system in the postinfarct LV. Patients with broader QRS had fewer LV breakout sites from the conduction system. However, there was 3D mapping evidence of LV breakout from an intact conduction system in the majority of patients with LBBB.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco , Ventrículos do Coração , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Masculino , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Pessoa de Meia-Idade , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Ablação por Cateter/métodos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/complicações , Eletrocardiografia , Ramos Subendocárdicos/fisiopatologia , Idoso , Imageamento Tridimensional , Mapeamento Potencial de Superfície Corporal/métodos
18.
Eur Heart J Case Rep ; 7(2): ytad016, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36819886

RESUMO

Background: Guidelines support upgrade to cardiac resynchronization therapy (CRT) through His-bundle pacing (HBP) in pacing-induced cardiomyopathy and moderate left ventricular systolic dysfunction (LVSD). Lead-related venous occlusion can represent an obstacle to upgrade procedures. We describe a technique to overcome venous occlusion through direct puncture of a collateral vein facilitating upgrade to HBP. Case summary: An 84-year-old man with a right ventricular (RV) pacemaker was referred with New York Heart Association (NYHA) Class III breathlessness secondary to moderate LVSD (left ventricular ejection fraction [LVEF] 45%). Device interrogation revealed 100% RV pacing and AV-dyssynchrony. To optimize atrioventricular (AV) and interventricular (VV) synchrony a CRT upgrade with HBP was planned. Venography revealed an occluded left subclavian vein which was probed in a retrograde manner using a 6F MPA catheter from right femoral venous access. We were able to direct the catheter distal to the left brachio-cephalic vein and define the occlusion using contrast. A collateral branch was identified, a J-wire was left in this branch and venous access was secured at this medial subclavian site using the Seldinger technique. A right atrial lead was deployed and 69 cm ISI-1 His lead was deployed via a C315 sheath at the His-bundle. The resulted in non-selective HBP (Stim-QRS end 146 ms). There were no procedural complications. Two months later both symptoms and LV function (LVEF 55%) improved. Discussion: Lead-related venous occlusion occurs frequently and can be probed in a retrograde manner from femoral venous access using contrast, facilitating direct percutaneous puncture of collateral venous branches to allow upgrade to CRT via HBP.

19.
J Interv Card Electrophysiol ; 66(7): 1533-1539, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37594646

RESUMO

BACKGROUND: Catheter ablation is routinely used to treat scar-related atrial tachycardia (s-AT). Conventional ablation often involves creating anatomical "lines" that transect myocardial tissue supporting reentry. This can be extensive, creating iatrogenic scar as a nidus for future reentry, and may account for arrhythmia recurrence. High-density mapping may identify "narrower isthmuses" requiring less ablation, with ripple mapping proven to be an effective approach in identifying. This trial explores whether ablation of narrower isthmuses in s-AT, defined using ripple mapping, results in greater freedom from arrhythmia recurrence compared to conventional ablation. METHODS: The Ripple-AT-Plus trial (registration ClinicalTrials.gov , NCT03915691) is a prospective, multicentre, single-blinded, randomised controlled trial with 12-month follow-up. Two hundred s-AT patients will be randomised in a 1:1 fashion to either "ripple mapping-guided isthmus ablation" vs conventional ablation on the CARTO3 ConfiDENSE system (Biosense Webster). The primary outcome will compare recurrence of any atrial arrhythmia. Multicentre data will be analysed over a secure web-based cloud-storage and analysis software (CARTONETTM). CONCLUSION: This is the first trial that considers long-term patient outcomes post s-AT ablation, and whether targeting narrower isthmuses in the era of high density is optimal.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Cicatriz/cirurgia , Estudos Prospectivos , Taquicardia Supraventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
20.
J Interv Card Electrophysiol ; 66(3): 693-700, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36214805

RESUMO

BACKGROUND: Ultrasound (US) is being increasingly used to guide vascular access for electrophysiology (EP) procedures in many centres. Nonetheless, the incidence and predictors of vascular complications in the US era are limited. In this study, we describe our experience of vascular access-related complications associated with EP procedures which were performed with the routine use of US-guided vascular access. METHODS: A total of 10,158 consecutive EP procedures in 8361 patients performed from April 2014 (when our centre moved to a policy of routine US-guided vascular access for EP procedures) to March 2022 were included. The outcome of interest was any vascular access-related complication that occurred within 7 days of the procedure; these were classified as severe if surgical intervention and/or blood transfusion was required, major if non-surgical intervention or delayed hospital discharge was required, or minor if it did not fulfil the criteria for severe or major. RESULTS: During the study period, 2 (0.02%) severe vascular complications occurred, including 1 pseudo-aneurysm requiring surgery and 1 retroperitoneal haemorrhage requiring blood transfusion. Nine (0.09%) major complications occurred, including 6 hematomas managed by compression devices, 1 type B aortic dissection, 1 AV fistula managed conservatively and 1 haematoma managed conservatively but delayed hospital discharge. Eighteen (0.18%) minor haematomas were seen that did not require any intervention or delayed hospital discharge. On multivariable analysis, female sex [OR (95% CI): 2.5 (1.2, 5.4)] and use of an arterial access [OR (95% CI): 19.3 (7.1, 52.3)] were seen to be independent predictors of the 29 vascular complications. CONCLUSION: With the use of US-guided vascular access in EP procedures, major vascular complications are exceedingly rare, particularly those needing surgical intervention. Our results provide additional evidence for scientific guidelines to support US use.


Assuntos
Hematoma , Hemorragia , Humanos , Feminino , Incidência , Fatores de Risco , Hematoma/diagnóstico por imagem , Hematoma/epidemiologia , Hematoma/etiologia , Eletrofisiologia , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA