Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Vasc Interv Radiol ; 18(3): 337-42, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17377178

RESUMO

PURPOSE: To evaluate the efficacy of carotid artery stent placement with embolic protection. MATERIALS AND METHODS: During a 2-year period (May 2003 to April 2005), 232 patients underwent carotid artery stent placement with the Acculink RX stent-graft and an embolic protection device. There were 150 men (mean age,70 years; age range, 58-85 years) and 82 women (mean age, 76 years; age range, 56-82 years). One hundred sixty-five patients were symptomatic and 67 were asymptomatic. All patients were at high risk for carotid endarterectomy. RESULTS: The procedure was technically successful in 231 patients. The procedure was stopped in one patient due to asystole. In three patients, a cervical approach was necessary owing to aortic arch anatomy. During the procedure,11 patients (4.74%) experienced bradycardia and two developed a major stroke (0.86%). The mean follow-up was 30 months (range, 12-36 months). Four patients died. No stent occlusion was observed. During the late follow-up period(>30 days), two patients (0.86%) had minor strokes, three (1.29%) had nonfatal transient ischemic attacks, and seven(3.01%) had myocardial infarctions. CONCLUSION: Carotid artery stent placement with cerebral protection by using the specific devices compares favorably to previously reported surgical results.


Assuntos
Prótese Vascular/estatística & dados numéricos , Doenças das Artérias Carótidas/epidemiologia , Doenças das Artérias Carótidas/terapia , Embolização Terapêutica/instrumentação , Embolização Terapêutica/estatística & dados numéricos , Stents , Idoso , Idoso de 80 Anos ou mais , Feminino , Grécia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Resultado do Tratamento
2.
Cardiovasc Intervent Radiol ; 30(3): 370-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17295078

RESUMO

PURPOSE: Traumatic rupture of the thoracic aorta secondary to blunt chest trauma is a life-threatening emergency and a common cause of death, usually following violent collisions. The objective of this retrospective report was to evaluate the efficacy of endovascular treatment of thoracic aortic disruptions with a single commercially available stent-graft. METHODS: Nine men (mean age 29.5 years) were admitted to our institution between January 2003 and January 2006 due to blunt aortic trauma following violent motor vehicle collisions. Plain chest radiography, spiral computed tomography, aortography, and transesophageal echocardiography were used for diagnostic purposes in all cases. All patients were diagnosed with contained extramural thoracic aortic hematomas, secondary to aortic disruption. One patient was also diagnosed with a traumatic thoracic aortic dissection, secondary to blunt trauma. All subjects were poor surgical candidates, due to major injuries such as multiple bone fractures, abdominal hematomas, and pulmonary contusions. All repairs were performed using the EndoFit (LeMaitre Vascular) stent-graft. RESULTS: Complete exclusion of the traumatic aortic disruption and pseudoaneurysm was achieved and verified at intraoperative arteriography and on CT scans, within 10 days of the repair in all patients. In 1 case the deployment of a second cuff was necessary due to a secondary endoleak. In 2 cases the left subclavian artery was occluded to achieve adequate graft fixation. No procedure-related deaths have occurred and no cardiac or peripheral vascular complications were observed within the 12 months (range 8-16 months) follow-up. CONCLUSIONS: This is the first time the EndoFit graft has been utilized in the treatment of thoracic aortic disruptions secondary to chest trauma. The repair of such pathologies is technically feasible and early follow-up results are promising.


Assuntos
Angioplastia , Aorta Torácica/lesões , Ruptura Aórtica/cirurgia , Prótese Vascular , Traumatismo Múltiplo/cirurgia , Stents , Ferimentos não Penetrantes/cirurgia , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Aortografia , Humanos , Masculino , Traumatismo Múltiplo/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ferimentos não Penetrantes/diagnóstico por imagem
3.
J Endovasc Ther ; 12(3): 280-7, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15943502

RESUMO

PURPOSE: To evaluate the feasibility and efficacy of a specific aortomonoiliac endograft and the durability of the femorofemoral bypass for treatment of abdominal aortic aneurysm (AAA). METHODS: From 2002 to 2004, 39 high-risk (ASA III/IV) patients (36 men; median age 74 years, range 63-84) with AAA (n = 33) or AAA and common iliac artery aneurysm (n = 6) were treated with an EndoFit aortomonoiliac endograft and femorofemoral crossover bypass. The contralateral iliac axis was obstructed with an endoluminal occluder. Patients were followed with contrast-enhanced computed tomography at 1, 6, 12, and 24 months. RESULTS: EndoFit AMI stent-grafts were implanted successfully in all patients. Perioperative mortality was zero. Endoleak occurred in 3 (7.7%) cases. A proximal type I endoleak was identified at 1 month and was treated with a proximal cuff. Two type II endoleaks are under surveillance because the aneurysm sac shows no enlargement. Thrombosis of the femorofemoral graft occurred in 1 case during the immediate postoperative period due to insufficient inflow from a residual stenosis of the endograft (primary patency 97.5%). The deficit was treated successfully (secondary patency 100%). Two (5.1%) tunnel hematomas were treated conventionally. Median follow-up was 14 months (range 6-30). All patients are alive. None of the aneurysms has ruptured or been converted to an open procedure. Graft migration, serious infection, paraplegia, distal embolization, or any other serious complication has not been observed. CONCLUSIONS: In high surgical risk patients with complex iliac anatomy, aortomonoiliac endograft with femorofemoral crossover bypass is feasible and efficacious. Moreover, the midterm patency of the extra-anatomic bypass appears quite satisfactory.


Assuntos
Angioscopia/métodos , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/instrumentação , Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA