Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38197916

RESUMO

OBJECTIVES: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI). METHODS: In a prospective registry of consecutive patients undergoing first PVI, mean EAT attenuation values were measured on contrast-enhanced cardiac CT scans in Hounsfield units (HU) within low (- 195 to - 45 HU) and high (- 44 to - 15 HU) threshold EAT compartments around the left atrium (LA). EAT dispersion was defined as the difference between the mean HU values within the two EAT compartments. Continuous variables were compared between groups using the Mann-Whitney U test and cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. RESULTS: A total of 208 patients were included, 135 with paroxysmal AF and 73 with persistent AF. LA EAT dispersion was significantly larger in patients with persistent compared to paroxysmal AF (52.6 HU vs. 49.9 HU; p = 0.001). After 1 year of follow-up, LA EAT dispersion above the mean (> 50.8 HU) was associated with a higher risk of AF recurrence (HR 2.3, 95% CI 1.5-3.6; p < 0.001). It retained its predictive value when corrected for age, sex, body mass index, LA volume, and AF type (HR 2.8, 95% CI 1.6-4.6; p < 0.001). CONCLUSION: A larger LA EAT dispersion on contrast-enhanced cardiac CT scans, reflecting EAT heterogeneity, is independently associated with AF recurrence after PVI. CLINICAL RELEVANCE STATEMENT: Based on LA EAT dispersion assessment, a more accurate risk stratification and patient selection may be possible based on a pre-procedural cardiac CT when planning PVI. KEY POINTS: • Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). • A larger left atrial EAT dispersion in a pre-procedural cardiac CT was associated with a higher 1-year AF recurrence risk after pulmonary vein isolation. • A pre-procedural cardiac CT with left atrial EAT dispersion assessment may provide a more accurate risk stratification and patient selection for PVI.

2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38597211

RESUMO

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Fenótipo , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
Pacing Clin Electrophysiol ; 47(6): 853-861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38655610

RESUMO

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida
4.
J Cardiovasc Electrophysiol ; 34(2): 292-299, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36490307

RESUMO

INTRODUCTION: Contact force sensing catheters are widely used for ablation of cardiac arrhythmias. They allow quantification of catheter-to-tissue contact, which is an important determinant for lesion formation and may reduce the risk of complications. The accuracy of these sensors may vary across the measurement range, catheter-to-tissue angle, and amongst manufacturers. We aim to compare the accuracy and reproducibility of four different force sensing ablation catheters. METHODS: A measurement setup containing a heated saline water bath with an integrated force measurement unit was constructed and validated. Subsequently, we investigated four different catheter models, each equipped with a unique measurement technology: Tacticath Quartz (Abbott), AcQBlate Force (Biotronik/Acutus), Stablepoint (Boston Scientific), and Smarttouch SF (Biosense Webster). For each model, the accuracy of three different catheters was measured within the range of 0-60 g and at contact angles of 0°, 30°, 45°, 60°, and 90°. RESULTS: In total, 6685 measurements were performed using 4 × 3 catheters (median of 568, interquartile range: 511-606 measurements per catheter). Over the entire measurement-range, the force measured by the catheters deviated from the real force by the following absolute mean values: Tacticath 1.29 ± 0.99 g, AcQBlate Force 2.87 ± 2.37 g, Stablepoint 1.38 ± 1.29 g, and Smarttouch 2.26 ± 2.70 g. For some models, significant under- and overestimation of >10 g were observed at higher forces. Mean absolute errors of all models across the range of 10-40 g were <3 g. CONCLUSION: Contact measured by force-sensing catheters is accurate with 1-3 g deviation within the range of 10-40 g. Significant errors can occur at higher forces with potential clinical consequences.


Assuntos
Ablação por Cateter , Catéteres , Humanos , Reprodutibilidade dos Testes , Desenho de Equipamento , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Cateteres Cardíacos
5.
Europace ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165671

RESUMO

BACKGROUND: Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS: The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS: Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION: When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters.

6.
Europace ; 25(4): 1500-1502, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36892147

RESUMO

AIMS: Pulsed field ablation (PFA) for pulmonary vein isolation (PVI) combines the benefits of high procedural efficacy and safety. Transseptal puncture (TSP) to obtain left atrial (LA) access during PVI remains an important source of complications during LA procedures. For PFA procedures, TSP is generally performed using a standard transseptal sheath that is then exchanged over the wire for a dedicated PFA sheath, which might be a potential source for air embolism. We aimed to prospectively evaluate the feasibility and safety of a simplified workflow using the PFA sheath (Faradrive, Boston Scientific) directly for TSP. METHODS AND RESULTS: We prospectively enrolled 100 patients undergoing PVI using PFA at two centres. TSP was performed using the PFA sheath and a standard 98 cm transseptal needle under fluoroscopic guidance. TSP via the PFA sheath was successfully performed in all patients and no complications occurred. The median time from the first groin puncture to the completed LA access was 12 min (IQR 8-16 min). CONCLUSION: An over-the-needle TSP directly with the PFA sheath proved feasible and safe in our study. This simplified workflow has the potential to reduce the risk of air embolism, to shorten procedure time, and to reduce cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Embolia Aérea , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Embolia Aérea/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Punções/métodos , Resultado do Tratamento
7.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225174

RESUMO

AIMS: The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data are scarce. METHODS AND RESULTS: Consecutive patients undergoing PWA using PFA were included. Posterior wall ablation was performed using a pentaspline PFA catheter and verified by 3D-electroanatomical mapping. Follow-up was performed using 7-day Holter ECGs 3, 6, and 12 months after ablation. Recurrence of any atrial arrhythmia lasting more than 30 s was defined as failure. Lesion durability was assessed during redo procedures. Posterior wall ablation was performed in 215 patients (70% males, median age 70 [IQR 61-75] years, 67% redo procedures) and was successful in all patients (100%) by applying a median of 36 (IQR 32-44) PFA lesions. Severe adverse events were cardiac tamponade and vascular access complication in one patient each (0.9%). Median follow-up was 7.3 (IQR 5.0-11.8) months. One-year arrhythmia-free outcome in Kaplan-Meier analysis was 53%. A redo procedure was performed in 26 patients (12%) after a median of 6.9 (IQR 2.4-11) months and showed durable PWA in 22 patients (85%) with only minor lesion regression. Among four patients with posterior wall reconnection, three (75%) presented with roof-dependent AT. CONCLUSION: Posterior wall ablation with this pentaspline PFA catheter can be safely and efficiently performed with a high durability observed during redo procedures. The added value of durable PWA for the treatment of atrial fibrillation remains to be evaluated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Veias Pulmonares/cirurgia , Recidiva
8.
Radiology ; 305(1): 56-65, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35670718

RESUMO

Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at cardiac CT may be a noninvasive surrogate marker for the metabolic activity of EAT. Purpose To determine the relationship between LA e-EAT and recurrence after AF ablation. Materials and Methods In a secondary analysis of a prospective registry of consecutive patients (from July 2018 to December 2019) undergoing first AF ablation, total and LA EAT were segmented on preprocedural noncontrast- and contrast-enhanced cardiac CT scans. LA e-EAT volume fraction was defined as the LA EAT volume difference between the noncontrast- and contrast-enhanced scan divided by the total LA EAT volume on the noncontrast-enhanced scan (threshold values, -15 HU to -195 HU). Continuous variables were compared between groups by using the Mann-Whitney U test. Cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. Results A total of 212 patients (mean age, 64 years; 159 men) who underwent a first AF ablation were included (paroxysmal AF, 64%; persistent AF, 36%). The LA EAT volume was higher in patients with persistent versus paroxysmal AF (50 cm3 [IQR, 37-72] vs 37 [IQR, 27-49]; P < .001), but no difference was found for LA e-EAT (P = .09). After 1 year of follow-up, AF recurrence rate was 77 of 212 (36%). LA e-EAT above the mean (>33%) was associated with a higher risk of AF recurrence (hazard ratio [HR], 2.1; 95% CI: 1.3, 3.3; P < .01). In a multivariable Cox regression analysis, LA e-EAT retained its predictive value when corrected for sex, age, AF phenotype, LA volume index, and LA EAT volume (HR, 1.9; 95% CI: 1.1, 3.1; P = .02). Conclusion Left atrial enhancing epicardial adipose tissue was independently associated with recurrence after atrial fibrillation ablation. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Stojanovska in this issue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Tecido Adiposo/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Recidiva , Tomografia Computadorizada por Raios X/métodos
9.
J Cardiovasc Electrophysiol ; 33(7): 1617-1627, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35614867

RESUMO

INTRODUCTION: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. METHODS: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre- and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random-effects meta-analysis. RESULTS: We included 69 patients (median age 78 years [interquartile range (IQR) 72-84 years], 26% women). Follow-up duration between baseline and follow-up TTE was 11.4 months (IQR 3.5-20.1 months). At follow-up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow-up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta-analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97-1.53, p = .11). CONCLUSION: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Observacionais como Assunto , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/epidemiologia
10.
Europace ; 24(8): 1248-1255, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35699395

RESUMO

AIMS: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. METHODS AND RESULTS: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). CONCLUSION: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
11.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
12.
J Cardiovasc Electrophysiol ; 32(6): 1610-1619, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33928711

RESUMO

INTRODUCTION: Chemical ablation by retrograde infusion of ethanol into the vein of Marshall (VOM-EI) can facilitate the achievement of mitral isthmus block. This study sought to describe the efficacy and safety of this technique. METHODS AND RESULTS: Twenty-two consecutive patients (14 males, median age 71 years) with attempted VOM-EI for mitral isthmus ablation were included in the study. VOM-EI was successfully performed with a median of 4 ml of 96% ethanol in 19 patients (86%) and the mitral isthmus was successfully blocked in all (100%). Touch up endocardial and/or epicardial ablation after VOM-EI was necessary for 12 patients (63%). Perimitral flutter was present in 12 patients (63%) during VOM-EI and terminated or slowed by VOM-EI in 4 and 3 patients, respectively. The low-voltage area of the mitral isthmus region increased from 3.1 cm2 (interquartile range [IQR] 0-7.9) before to 13.2 cm2 (IQR: 8.2-15.0) after VOM-EI and correlated significantly with the volume of ethanol injected (p = .03). Median high-sensitive cardiac troponin-T increased significantly from 330 ng/L (IQR: 221-516) the evening of the procedure to 598 ng/L (IQR: 382-769; p = .02) the following morning. A small pericardial effusion occurred in three patients (16%), mild pericarditis in one (5%), and uneventful VOM dissection in two (11%). After a median follow-up of 3.5 months (IQR: 3.0-11.0), 10 of 18 patients (56%) with VOM-EI and available follow-up had arrhythmia recurrence. Repeat ablation was performed in five patients (50%) and peri-mitral flutter diagnosed in three (60%). CONCLUSION: VOM-EI is feasible, safe, and effective to achieve acute mitral isthmus block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Etanol/efeitos adversos , Humanos , Masculino , Recidiva , Veias
13.
Pacing Clin Electrophysiol ; 44(4): 703-710, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33675240

RESUMO

BACKGROUND: Radiofrequency catheter ablation of idiopathic premature ventricular complexes (PVCs) is an effective method for eliminating symptoms and preventing/reversing arrhythmia-induced cardiomyopathy. One reason for procedural failure is low PVC frequency during the procedure. We aimed to investigate the relation between pre-procedural PVC burden and outcome of idiopathic PVC catheter ablation. METHODS: Patients who underwent idiopathic PVC ablation between 2013 and 2019 at two tertiary referral centers were retrospectively included. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24h-Holter at follow-up. RESULTS: Overall, 254 patients (median age 54 years [IQR 42-64]; 47% male) were enrolled. The median pre-ablation PVC-burden was 22% (IQR 11-31%), which was reduced to a post-ablation PVC burden of 0.3% (IQR 0-4%) after a median of 90 days. Sustained ablation success was achieved in 182 patients (72%). Pre-procedural PVC burden did not differ between patients with sustained ablation success and recurrence during follow-up (median 21% vs. 22%, p = .76). When assessed in pre-ablation PVC-burden groups of ≤5%, 6-15%, 16-30%, and ≥31%, sustained ablation success was achieved in 67%, 75%, 71%, and 72%, respectively, with no significant difference (p = .89). Sustained ablation outcome for PVC-burden ≤5% versus >5% showed no difference either (67% vs. 72%, p = .52). CONCLUSIONS: Pre-procedural Holter-determined PVC burden does not predict the outcome of idiopathic PVC ablation. Thus, catheter ablation may be a reasonable first choice also for patients with symptomatic yet rare PVCs.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Suíça
14.
BMC Cardiovasc Disord ; 20(1): 427, 2020 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-32993521

RESUMO

BACKGROUND: Inflammation plays an important role in the initiation and progression of atrial fibrillation (AF), but data about the relationship between subclinical inflammation and recurrence of AF after catheter ablation remains poorly studied. We aimed to assess whether plasma levels of C-reactive protein (CRP) are associated with long-term AF recurrence following catheter ablation. METHODS: Prior to the intervention, plasma CRP concentrations were measured in patients who underwent first catheter ablation for AF. AF recurrence was evaluated after 12 months and defined as any AF episode longer than 30 s recorded on either 12-lead electrocardiogram, 24-h Holter or 7-day Holter monitoring. Multivariable adjusted Cox models were constructed to examine the association of CRP levels and AF recurrence. RESULTS: Of the 711 patients (mean age: 61 years, 25% women) included in this study, 247 patients (35%) experienced AF recurrence after ablation. Patients who were in the highest CRP quartile had a higher rate of recurrent AF compared to those who were in the lowest quartile (53.4 vs. 33.1% at 1 year of follow-up; P = 0.004). The adjusted hazard ratios (aHR) of recurrent AF across increasing quartiles of CRP were 1.0 (reference), 1.26 (95% confidence interval [CI], 0.86-1.84), 1.15 (95% CI, 0.78-1.70) and 1.60 (95% CI, 1.10-2.34) (P trend = 0.015). A similar effect was observed when CRP was analyzed as continuous variable (aHR per unit increase, 1.21; 95% CI, 1.05-1.39; P = 0.009). When a predefined CRP cut-off of 3 mg/l was applied, patients with CRP levels of 3 mg/l or above had a higher risk of AF recurrence than those with levels below (aHR, 1.44; 95% CI, 1.06-1.95; P = 0.019). CONCLUSIONS: Increasing pre-interventional CRP levels are associated with a higher risk of AF recurrence in patients undergoing catheter ablation for AF. TRAIL REGISTRATION: ClinicalTrials.gov identifier, NCT03718364.


Assuntos
Fibrilação Atrial/cirurgia , Proteína C-Reativa/análise , Ablação por Cateter , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Biomarcadores/sangue , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
15.
Europace ; 21(11): 1750-1754, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31384937

RESUMO

AIMS: We aimed to assess the novel concept of using the paced PR interval (PRI) on the surface electrocardiogram (ECG) to prove trans-isthmus block after cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFl). METHODS AND RESULTS: Consecutive patients with AFl underwent linear radiofrequency ablation of the inferior CTI (6 o'clock). After AFl termination and/or presumed completion of the CTI line, CTI block was proven by atrial pacing by the ablation catheter medial (5 o'clock) and lateral to the line (7 and 9 o'clock). Corresponding PRIs were measured on the surface ECG. CTI block was assumed, if a sudden increase in the PRI was observed by moving the pacing site from 5 to 7 o'clock, and if the latter was longer than at 9 o'clock. Afterwards, bidirectional CTI block was confirmed by differential pacing. Thirty-one patients (mean age 67 ± 16 years, 81% male) underwent CTI ablation, and 18/31 (58%) were in AFl at the time of ablation (cycle length 249 ± 31 ms). Successful CTI block as defined by the PRI method was achieved in 31/31 (100%), and the mean PRIs during pacing at 5, 7, and 9 o'clock were 203 ± 56 ms, 329 ± 70 ms, and 296 ± 66 ms, respectively. Cavotricuspid isthmus block was confirmed in all patients (100%) by coronary sinus pacing with a reversal of the local activation sequence lateral to the isthmus line. CONCLUSION: The method of PRI analysis on the surface ECG to guide CTI ablation is easy to apply and highly accurate in confirming CTI block. This simple technique enables the novel concept of CTI ablation and proof of block with a single catheter.


Assuntos
Flutter Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Idoso , Flutter Atrial/fisiopatologia , Feminino , Humanos , Masculino , Estudo de Prova de Conceito , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 42(3): 306-308, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30397910

RESUMO

Left atrial appendage (LAA) may be the source for initiation and maintenance of atrial fibrillation (AF). This report shows restoration of sinus rhythm in the atria during radiofrequency wide-area LAA electrical isolation, whereas AF persists in the LAA.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Humanos , Reoperação
17.
J Cardiovasc Electrophysiol ; 27(2): 175-82, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26541121

RESUMO

INTRODUCTION: Radiofrequency (RF) ablation of atrial tachycardia (AT) with earliest activation at the His-bundle may be associated with the risk of AV block, and detection of this AT origin using the electrocardiogram (ECG) would be helpful in planning ablation. Aim of this study was to characterize the P-wave morphology and intracardiac electrograms at the successful ablation site for this group of ATs. METHODS: All consecutive patients undergoing ablation for AT with earliest activation at the His-bundle were included. Twelve-lead ECG and intracardiac electrograms were analyzed. RESULTS: A total of 33 patients underwent successful ablation. The P-wave and the PR interval during AT (cycle length 460 ± 88, range 360-670 milliseconds) were significantly shorter compared to sinus rhythm 87 ± 18 vs. 117 ± 23 and 131 ± 37 vs. 170 ± 47 milliseconds, respectively, P < 0.01. In 28 patients (85%), the P-wave was biphasic (-/+) or triphasic (+/-/+) in the precordial leads, especially V4 -V6 , and in 25 patients (76%) it was biphasic (-/+) or triphasic (+/-/+) in the inferior leads. RF was delivered at the following locations: noncoronary aortic cusp (NCC) in 24 patients, antero-septal left atrium in 4, supero-septal right atrium in 3, left coronary cusp in 1, and between the right coronary cusp and the NCC in 1. Atrial bipolar electrograms at the successful ablation site preceded the P-wave by 38 ± 11 (range 10-60) milliseconds, and AT termination was obtained after a mean RF energy time of 10 ± 8 (range 2-31) seconds. CONCLUSION: A characteristic narrow and biphasic (-/+) or triphasic (+/-/+) P-wave in the inferior and precordial leads reliably identifies the group of AT arising from the para-Hisian region.


Assuntos
Potenciais de Ação , Fascículo Atrioventricular/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Taquicardia Supraventricular/diagnóstico , Idoso , Fascículo Atrioventricular/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia
20.
Heart Rhythm O2 ; 5(5): 257-265, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38840763

RESUMO

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed. Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA. Methods: Consecutive patients with arrhythmia recurrences after a prior thermal ablation undergoing a repeat procedure using a multipolar PFA catheter from May 2021 and December 2022 were included. After 3-dimensional electroanatomic mapping, reconnected pulmonary veins (PVs) were reisolated and veins with only ostial isolation wither ablated to widen antral PV isolation. Posterior wall ablation was performed if all PVs were durably isolated or in case of low-voltage areas on the posterior wall at the discretion of the operator. Patients underwent follow-up with 7-day Holter electrocardiography after 3, 6, and 12 months. Results: A total of 186 patients undergoing a repeat procedure using PFA were included. The median number of previous ablations was 1 (range 1-6). The prior ablation modality was radiofrequency in 129 patients (69.4%), cryoballoon in 51 (27.4%), and epicardial ablation in 6 (3.2%). At the beginning of the procedure, 258 of 744 PVs (35%) showed reconnections. Additional antral ablations were applied in 236 of 486 still isolated veins (49%). Posterior wall ablation was added in 125 patients (67%). Major complications occurred in 1 patient (transient ischemic attack 0.5%). Freedom from arrhythmia recurrence in Kaplan-Meier-analysis was 78% after 6 months and 54% after 12 months. Conclusion: PFA is a versatile and safe option for repeat procedures after failed prior thermal ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA