1.
J Appl Biomech ; 31(3): 164-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25642697

RESUMO

Impact damping by elastic fixation is a principal engineering strategy to increase the durability of load-bearing structures exposed to prolonged dynamic loading. This biomechanical study evaluated axial impact damping provided by a novel dynamic locking plate. In this design, locking screw holes are elastically suspended within a silicone envelope inside the locking plate. Axial impact damping was assessed for 3 distinct fixation constructs applied to bridge a 10-mm fracture gap of a femoral diaphysis surrogate: a standard locking plate, a dynamic locking plate, and an Ilizarov ring fixator. First, the 3 fixation constructs were characterized by determining their axial stiffness. Subsequently, constructs were subjected to a range of axial impact loads to quantify damping of force transmission. Compared with standard locked plating constructs, dynamic plating constructs were 58% less stiff (P < .01) and Ilizarov constructs were 88% less stiff (P < .01). Impact damping correlated inversely with construct stiffness. Compared with standard plating, dynamic plating constructs and Ilizarov constructs dampened the transmission of impact loads by up to 48% (P < .01) and 74% (P < .01), respectively. In conclusion, lower construct stiffness correlated with superior damping of axial impact loads. Dynamic locking plates provide significantly greater impact damping compared with standard locking plates.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Aceleração , Força Compressiva , Módulo de Elasticidade , Análise de Falha de Equipamento , Desenho de Prótese , Estresse Mecânico , Viscosidade
2.
J Clin Med ; 13(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38792446

RESUMO

The controlled dynamization of fractures can promote natural fracture healing by callus formation, while overly rigid fixation can suppress healing. The advent of locked plating technology enabled new strategies for the controlled dynamization of fractures, such as far cortical locking (FCL) screws or active plates with elastically suspended screw holes. However, these strategies did not allow for the use of non-locking screws, which are typically used to reduce bone fragments to the plate. This study documents the first in vivo study on the healing of ovine tibia osteotomies stabilized with an advanced active plate (AAP). This AAP allowed plate application using any combination of locking and non-locking screws to support a wide range of plate application techniques. At week 9 post-surgery, tibiae were harvested and tested in torsion to failure to assess the healing strength. The five tibiae stabilized with an AAP regained 54% of their native strength and failed by spiral fracture through a screw hole, which did not involve the healed osteotomy. In comparison, tibiae stabilized with a standard locking plate recovered 17% of their strength and sustained failure through the osteotomy. These results further support the stimulatory effect of controlled motion on fracture healing. As such, the controlled dynamization of locked plating constructs may hold the potential to reduce healing complications and may shorten the time to return to function. Integrating controlled dynamization into fracture plates that support a standard fixation technique may facilitate the clinical adoption of dynamic plating.

3.
J Trauma ; 69(2): 411-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20699751

RESUMO

BACKGROUND: Hybrid plating (HP) may improve fixation strength of locked plating (LP) constructs by combining the use of locked and nonlocked screws within a bone segment. This biomechanical study evaluated whether a hybrid bridge plating construct provides greater fixation strength than an all-locked construct in the osteoporotic diaphysis. METHODS: LP and HP constructs were applied to a validated surrogate of the osteoporotic femoral diaphysis in a bridge plating configuration. In LP constructs, plates were applied with three locking screws on each side of the fracture gap and remained 1 mm elevated. In HP constructs, plates were applied with two conventional screws complemented by a single locked screw on each side of the fracture. Constructs were tested under dynamic loading to failure in bending, torsion, and axial loading to analyze construct strength and failure mechanism in each loading mode. RESULTS: Compared with the LP construct, the HP construct was 7% stronger in bending (p = 0.17), 42% stronger in torsion (p < 0.001), and 7% weaker in axial compression (p = 0.003). In bending, constructs failed by periprosthetic fracture. In torsion, LP constructs failed by screw breakage, and HP constructs failed by periprosthetic fracture or breakage of the locking screw. In axial compression, all constructs failed by screw migration. CONCLUSIONS: HP delivered similar bending strength and higher torsional strength than an all-locked bridge plating construct, while causing only a small decrease in axial strength. It may therefore provide an attractive alternative to an all-locked construct for plate fixation in the osteoporotic diaphysis.


Assuntos
Placas Ósseas , Parafusos Ósseos , Diáfises/cirurgia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Osteoporose/complicações , Fenômenos Biomecânicos , Diáfises/patologia , Fraturas do Fêmur/etiologia , Fixação Interna de Fraturas/métodos , Humanos , Teste de Materiais , Modelos Biológicos , Osteoporose/patologia , Estresse Mecânico , Resistência à Tração , Suporte de Carga
4.
Ann Biomed Eng ; 48(1): 68-78, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31342338

RESUMO

Bicycle helmets effectively mitigate skull fractures, but there is increasing concern on their effectiveness in mitigating traumatic brain injury (TBI) caused by rotational head acceleration. Bicycle falls typically involve oblique impacts that induce rotational head acceleration. Recently, bicycle helmet with dedicated rotation-damping systems have been introduced to mitigate rotational head acceleration. This study investigated the impact performance of four helmets with different rotation-damping systems in comparison to a standard bicycle helmet without a rotation-damping system. Impact performance was tested under oblique impact conditions by vertical drops of a helmeted headform onto an oblique anvil at 6.2 m/s impact speed. Helmet performance was quantified in terms of headform kinematics, corresponding TBI risk, and resulting brain strain. Of the four rotation-damping systems, two systems significantly reduced rotational head acceleration, TBI risk, and brain strain compared to the standard bicycle helmet. One system had no significant effect on impact performance compared to control helmets, and one system significantly increase linear and rotational head acceleration by 62 and 61%, respectively. In conclusion, results revealed significant differences in the effectiveness between rotation-damping systems, whereby some rotation-damping systems significantly reduced rotational head acceleration and associated TBI risk.


Assuntos
Ciclismo , Dispositivos de Proteção da Cabeça , Equipamentos Esportivos , Aceleração , Fenômenos Biomecânicos , Lesões Encefálicas Traumáticas/prevenção & controle , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Rotação
5.
Accid Anal Prev ; 124: 58-65, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30634159

RESUMO

BACKGROUND: A novel bicycle helmet concept has been developed to mitigate rotational head acceleration, which is a predominant mechanism of traumatic brain injury (TBI). This WAVECEL concept employs a collapsible cellular structure that is recessed within the helmet to provide a rotational suspension. This cellular concept differs from other bicycle helmet technologies for mitigation of rotational head acceleration, such as the commercially available Multi-Directional Impact Protection System (MIPS) technology which employs a slip liner to permit sliding between the helmet and the head during impact. This study quantified the efficacy of both, the WAVECEL cellular concept, and a MIPS helmet, in direct comparison to a traditional bicycle helmet made of rigid expanded polystyrene (EPS). METHODS: Three bicycle helmet types were subjected to oblique impacts in guided vertical drop tests onto an angled anvil: traditional EPS helmets (CONTROL group); helmets with a MIPS slip liner (SLIP group); and helmets with a WAVECEL cellular structure (CELL group). Helmet performance was evaluated using 4.8 m/s impacts onto anvils angled at 30°, 45°, and 60° from the horizontal plane. In addition, helmet performance was tested at a faster speed of 6.2 m/s onto the 45° anvil. Five helmets were tested under each of the four impact conditions for each of the three groups, requiring a total of 60 helmets. Headform kinematics were acquired and used to calculate an injury risk criterion for Abbreviated Injury Score (AIS) 2 brain injury. RESULTS: Linear acceleration of the headform remained below 90 g and was not associated with the risk of skull fracture in any impact scenario and helmet type. Headform rotational acceleration in the CONTROL group was highest for 6.2 m/s impacts onto the 45° anvil (7.2 ± 0.6 krad/s2). In this impact scenario, SLIP helmets and CELL helmets reduced rotational acceleration by 22% (p = 0003) and 73% (p < 0.001), respectively, compared to CONTROL helmets. The CONTROL group had the highest AIS 2 brain injury risk of 59 ± 8% for 6.2 m/s impacts onto the 45° anvil. In this impact scenario, SLIP helmets and CELL helmets reduced the AIS 2 brain injury risk to 34.2% (p = 0.001) and 1.2% (p < 0.001), respectively, compared to CONTROL helmets. DISCUSSION: Results of this study are limited to a narrow range of impact conditions, but demonstrated the potential that rotational acceleration and the associated brain injury risk can be significantly reduced by the cellular WAVECEL concept or a MIPS slip liner. Results obtained under specific impact angles and impact velocities indicated performance differences between these mechanisms. These differences emphasize the need for continued research and development efforts toward helmet technologies that further improve protection from brain injury over a wide range a realistic impact parameters.


Assuntos
Ciclismo/lesões , Lesões Encefálicas Traumáticas/prevenção & controle , Dispositivos de Proteção da Cabeça , Aceleração/efeitos adversos , Fenômenos Biomecânicos , Estudos de Casos e Controles , Desenho de Equipamento , Humanos
6.
Iowa Orthop J ; 28: 73-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19223952

RESUMO

Contemporary locking plates promote biological fixation through indirect reduction techniques and by elevating the plate from the bone. They have improved fixation strength in osteoporotic bone. Periarticular locking plates are rapidly being adopted for bridge plating of periprosthetic femur fractures. When these plates are used for indirect reduction and bridge plating osteosynthesis, fracture union occurs by secondary bone healing with callus formation which is stimulated by interfragmentary motion. In two patients with similar periprosthetic femur fractures treated with periarticular locking plates one fracture healed by ample callus formation while the other resulted in a non-union and had no callus formation six months post-operatively. The case, which progressed to secondary bone healing with callus formation, exhibited varus migration as a result of loss of fixation. The non-union case retained stable fixation. The difference in outcome may indicate that callus formation was promoted by interfragmentary motion secondary to loss of fixation. Conversely, in absence of fixation failure, callus formation was suppressed by stable fixation with a stiff locking plate construct which reduced interfragmentary motion. These observations suggest that locked plating constructs should be sufficiently flexible when applied for bridge plating of comminuted fractures to promote callus formation.


Assuntos
Placas Ósseas , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Prótese de Quadril , Acidentes por Quedas , Idoso , Fenômenos Biomecânicos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Consolidação da Fratura , Humanos , Radiografia , Falha de Tratamento
7.
J Biomech ; 40(15): 3297-304, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17572432

RESUMO

In vitro comparative testing of fracture fixation implants is limited by the highly variable material properties of cadaveric bone. Bone surrogate specimens are often employed to avoid this confounding variable. Although validated surrogate models of normal bone (NB) exist, no validated bone model simulating weak, osteoporotic bone (OPB) is available. This study presents an osteoporotic long-bone model designed to match the lower cumulative range of mechanical properties found in large series of cadaveric femora reported in the literature. Five key structural properties were identified from the literature: torsional rigidity and strength, bending rigidity and strength, and screw pull-out strength. An OPB surrogate was designed to meet the low range for each of these parameters, and was mechanically tested. For comparison, the same parameters were determined for surrogates of NB. The OPB surrogate had a torsional rigidity and torsional strength within the lower 2% and 16%, respectively, of the literature based cumulative range reported for cadaveric femurs. Its bending rigidity and bending strength was within the lower 11% and 8% of the literature-based range, respectively. Its pull-out strength was within the lower 2% to 16% of the literature based range. With all five structural properties being within the lower 16% of the cumulative range reported for native femurs, the OPB surrogate reflected the diminished structural properties seen in osteoporotic femora. In comparison, surrogates of NB demonstrated structural properties within 23-118% of the literature-based range. These results support the need and utility of the OPB surrogate for comparative testing of implants for fixation of femoral shaft fractures in OPB.


Assuntos
Fraturas Ósseas/patologia , Implantes Experimentais , Modelos Biológicos , Osteoporose/cirurgia , Fenômenos Biomecânicos , Humanos
8.
Iowa Orthop J ; 37: 1-10, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28852327

RESUMO

BACKGROUND: Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has been shown to induce faster and stronger bone healing in vivo compared to rigid locking plates. This prospective observational study represents the first clinical use of active locking plates. It documents our early clinical experience with active plates for stabilization of humeral shaft fractures to assess their durability and understand potential complications. METHODS: Eleven consecutive patients with humeral shaft fractures (AO/OTA types 12 A-C) were prospectively enrolled at a level I and a level II trauma center. Fractures were stabilized by using active locking plates without supplemental bone graft or bone morphogenic proteins. The screw holes of active locking plates are elastically suspended in elastomer envelopes inside the plate, enabling up to 1.5 mm of controlled interfragmentary motion. Progression of fracture healing and integrity of implant fixation was assessed radiographically at 3, 6, 12, and 24 weeks post surgery. Patient-reported functional outcome measures were obtained at 6, 12, and 24 weeks post surgery. The primary endpoint of this study was plate durability in absence of plate bending or breakage, or failure of the elastically suspended locking hole mechanism. Secondary endpoints included fracture healing, complications requiring revision surgery, and functional outcome scores. RESULTS: The eleven patients had six simple AO/ OTA type 12A fractures, three wedge type 12B fractures, and two comminuted type 12C fracture, including one open fracture. All active locking plates endured the 6-month loading period without any signs of fatigue or failure. Ten of eleven fractures healed at 10.9 ± 5.2 weeks, as evident by bridging callus and pain-free function. One fracture required revision surgery 37 weeks post surgery due to late fixation failure at the screwbone interface in the presence of a atrophic delayed union. The average Disability of the Arm, Shoulder and Hand (DASH) score improved from 31 ± 22 at week 6 to 13 ± 15 by week 24, approaching that of the normal, healthy population (DASH = 10.1). By week 12, the difference between Constant shoulder scores, expressed as the difference between the affected and contralateral arm (8 ± 8), was considered excellent. By week 24, the SF-12 physical health score (44 ± 9) and mental health score (48 ± 11) approached the mean value of 50 that represents the norm for the general U.S. population. CONCLUSION: Absence of failure of the plate and locking holes suggests that dynamic fixation of humeral shaft fractures with active plates provides safe and effective fixation. Moreover, early callus bridging and excellent functional outcome scores suggest that dynamic fixation with active locking plates may promote increased fracture healing over standard locked plating.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Adulto , Parafusos Ósseos , Feminino , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação , Resultado do Tratamento , Adulto Jovem
9.
J Orthop Trauma ; 31(10): 531-537, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28657927

RESUMO

BACKGROUND: Decreasing the stiffness of locked plating constructs can promote natural fracture healing by controlled dynamization of the fracture. This biomechanical study compared the effect of 4 different stiffness reduction methods on interfragmentary motion by measuring axial motion and shear motion at the fracture site. METHODS: Distal femur locking plates were applied to bridge a metadiaphyseal fracture in femur surrogates. A locked construct with a short-bridge span served as the nondynamized control group (LOCKED). Four different methods for stiffness reduction were evaluated: replacing diaphyseal locking screws with nonlocked screws (NONLOCKED); bridge dynamization (BRIDGE) with 2 empty screw holes proximal to the fracture; screw dynamization with far cortical locking (FCL) screws; and plate dynamization with active locking plates (ACTIVE). Construct stiffness, axial motion, and shear motion at the fracture site were measured to characterize each dynamization methods. RESULTS: Compared with LOCKED control constructs, NONLOCKED constructs had a similar stiffness (P = 0.08), axial motion (P = 0.07), and shear motion (P = 0.97). BRIDGE constructs reduced stiffness by 45% compared with LOCKED constructs (P < 0.001), but interfragmentary motion was dominated by shear. Compared with LOCKED constructs, FCL and ACTIVE constructs reduced stiffness by 62% (P < 0.001) and 75% (P < 0.001), respectively, and significantly increased axial motion, but not shear motion. CONCLUSIONS: In a surrogate model of a distal femur fracture, replacing locked with nonlocked diaphyseal screws does not significantly decrease construct stiffness and does not enhance interfragmentary motion. A longer bridge span primarily increases shear motion, not axial motion. The use of FCL screws or active plating delivers axial dynamization without introducing shear motion.


Assuntos
Placas Ósseas , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Modelos Anatômicos , Resistência ao Cisalhamento , Fenômenos Biomecânicos , Parafusos Ósseos , Diáfises/lesões , Diáfises/cirurgia , Desenho de Equipamento , Fixação Interna de Fraturas/métodos , Humanos
10.
J Orthop Trauma ; 31(2): 71-77, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27861456

RESUMO

OBJECTIVES: Active plates dynamize a fracture by elastic suspension of screw holes within the plate. We hypothesized that dynamic stabilization with active plates delivers stronger healing relative to standard compression plating. METHODS: Twelve sheep were randomized to receive either a standard compression plate (CP) or an active plate (ACTIVE) for stabilization of an anatomically reduced tibial osteotomy. In the CP group, absolute stabilization was pursued by interfragmentary compression with 6 cortical screws. In the ACTIVE group, dynamic stabilization after bony apposition was achieved with 6 elastically suspended locking screws. Fracture healing was analyzed weekly on radiographs. After sacrifice 9 weeks postsurgery, the torsional strength of healed tibiae and contralateral tibiae was measured. Finally, computed tomography was used to assess fracture patterns and healing modes. RESULTS: Healing in both groups included periosteal callus formation. ACTIVE specimens had almost 6 times more callus area by week 9 (P < 0.001) than CP specimens. ACTIVE specimens recovered on average 64% of their native strength by week 9, and were over twice as strong as CP specimens, which recovered 24% of their native strength (P = 0.008). Microcomputed tomography demonstrated that compression plating induced a combination of primary bone healing and gap healing. Active plating consistently stimulated biological bone healing by periosteal callus formation. CONCLUSIONS: Compared with compression plating, dynamic stabilization of simple fractures with active plates delivers significantly stronger healing.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Animais , Parafusos Ósseos , Análise de Falha de Equipamento , Desenho de Prótese , Ovinos , Fraturas da Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
J Bone Joint Surg Am ; 98(6): 466-74, 2016 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-26984914

RESUMO

BACKGROUND: Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates. METHODS: Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure. RESULTS: At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap. CONCLUSIONS: Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE: The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura/fisiologia , Fraturas Cominutivas/cirurgia , Fraturas da Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Estudos Prospectivos , Desenho de Prótese , Carneiro Doméstico
12.
J Orthop Res ; 23(6): 1329-35, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15994054

RESUMO

Previous mechanical studies concerning cut-out of lag screws for pertrochanteric hip fractures have relied on static or dynamic uniaxial loading regimens to induce construct failure by varus collapse and superior cut-out. However, the hip is loaded in a multiplanar, dynamic manner during normal gait. We designed a hip implant performance simulator (HIPS) system to evaluate lag screw cut-out under multiplanar loading representative of normal gait. Five surrogate pertrochanteric fracture specimens with lag screw fixation were loaded up to 20,000 cycles using a biaxial rocking motion (BRM) gait simulation protocol. Another five specimens were loaded using a standard uniaxial loading protocol. The BRM loading group exhibited combined varus collapse (5.4+/-2.9 degrees ) and backward rotation (7.2+/-2.8 degrees ). The uniaxial loading group exhibited four times less varus collapse (1.4+/-1.1 degrees ) as compared to the BRM group, and only negligible rotation. For correlation of lag screw migration in surrogate specimens to that in native bone, six human cadaveric specimens were subjected to BRM loading. The degree of varus collapse (8.5+/-7.7 degrees ) and rotation (7.2+/-6.4 degrees ) in cadaveric specimens were comparable to that in surrogate specimens, with the surrogate specimens showing significantly less variability. The results demonstrate that accounting for clinically realistic multiplanar loading vectors significantly affects implant migration, and therefore should be considered when evaluating the fixation strength of hip screw implants.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Fenômenos Biomecânicos , Fraturas do Quadril/fisiopatologia , Humanos , Rotação , Caminhada
13.
J Biomech ; 38(4): 667-72, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15713286

RESUMO

This biomechanical study reports strain gradients in patellofemoral joint cross-sections of seven porcine specimens in response to 1% unconfined axial compression subsequent to specific amounts of off-set strain. Strain distributions were quantified with a customized laser-based electronic speckle pattern interferometry (ESPI) system in a non-contact manner, delivering high-resolution, high-sensitivity strain maps over entire patellofemoral cartilage cross-sections. Strain reports were evaluated to determine differences in strain magnitudes between the superficial, middle, and deep cartilage layers in femoral and patellar cartilage. In addition, the effect of 5%, 10%, 15%, and 20% off-set strain on depth-dependent strain gradients was quantified. Regardless of the amount of off-set strain, the superficial layer of femoral cartilage absorbed the most strain, and the deep layer absorbed the least strain. These depth-dependent strain gradients were most pronounced for 5% off-set strain, at which the superficial layer absorbed on average 5.7 and 23.7 times more strain as compared to the middle and deep layers, respectively. For increased off-set strain levels, strain gradients became less pronounced. At 20% off-set strain, differences in layer-specific strain were not statistically significant, with the superficial layer showing a 1.4 fold higher strain as the deep layer. Patellar cartilage exhibited similar strain gradients and effects of off-set strain, although the patellar strain was on average 19% larger as compared to corresponding femoral strain reports. This study quantified for the first time continuous strain gradients over patellofemoral cartilage cross-sections. Next to provision of a detailed functional characterization of normal diarthrodial joints, this novel experimental approach holds considerable attraction to investigate joint degenerative processes.


Assuntos
Cartilagem Articular/lesões , Entorses e Distensões/etiologia , Animais , Fenômenos Biomecânicos , Cartilagem Articular/fisiologia , Força Compressiva , Desenho de Equipamento , Técnicas In Vitro , Articulação do Joelho/patologia , Articulação do Joelho/fisiologia , Lasers , Suínos
14.
J Orthop Res ; 33(8): 1218-25, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25721801

RESUMO

Axial dynamization of an osteosynthesis construct can promote fracture healing. This biomechanical study evaluated a novel dynamic locking plate that derives symmetric axial dynamization by elastic suspension of locking holes within the plate. Standard locked and dynamic plating constructs were tested in a diaphyseal bridge-plating model of the femoral diaphysis to determine the amount and symmetry of interfragmentary motion under axial loading, and to assess construct stiffness under axial loading, torsion, and bending. Subsequently, constructs were loaded until failure to determine construct strength and failure modes. Finally, strength tests were repeated in osteoporotic bone surrogates. One body-weight axial loading of standard locked constructs produced asymmetric interfragmentary motion that was over three times smaller at the near cortex (0.1 ± 0.01 mm) than at the far cortex (0.32 ± 0.02 mm). Compared to standard locked constructs, dynamic plating constructs enhanced motion by 0.32 mm at the near cortex and by 0.33 mm at the far cortex and yielded a 77% lower axial stiffness (p < 0.001). Dynamic plating constructs were at least as strong as standard locked constructs under all test conditions. In conclusion, dynamic locking plates symmetrically enhance interfragmentary motion, deliver controlled axial dynamization, and are at least comparable in strength to standard locked constructs. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1218-1225, 2015.


Assuntos
Placas Ósseas , Diáfises/cirurgia , Fraturas do Fêmur/cirurgia , Consolidação da Fratura , Fenômenos Biomecânicos , Parafusos Ósseos , Fraturas do Fêmur/fisiopatologia , Humanos , Torção Mecânica
15.
J Orthop Trauma ; 16(6): 367-73, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12142823

RESUMO

OBJECTIVES: To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN: Biomechanical investigation on human cadaveric specimens. SETTING: Biomechanics laboratory. INTERVENTION: Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created in seven human cadaveric specimens. A prototype pelvic strap was applied subsequently at three distinct transverse levels around the pelvis. Circumferential pelvic compression was induced by gradual tensioning of the strap to attempt complete reduction of the symphysis diastasis. MAIN OUTCOME MEASUREMENTS: Pelvic reduction was evaluated with respect to strap tension and the strap application site. The effect of circumferential compression on intraperitoneal pressure and skin-strap interface pressure was measured. RESULTS: A successive increase in circumferential compression consistently induced a gradual decrease in symphysis diastasis. An optimal strap application site was determined, at which circumferential compression most effectively yielded pelvic reduction. The minimum strap tension required to achieve complete reduction of symphysis diastasis was determined to be 177 +/- 44 Newtons and 180 +/- 50 Newtons in the partially stable and unstable pelvis, respectively. CONCLUSIONS: Application of circumferential compression to the pelvic soft tissue envelope with a pelvic strap was an efficient means to achieve controlled reduction of external rotation-type pelvic fractures. This study derived application parameters with direct clinical implication for noninvasive emergent management of traumatic pelvic ring disruptions.


Assuntos
Fraturas Ósseas/terapia , Ossos Pélvicos/lesões , Idoso , Idoso de 80 Anos ou mais , Bandagens , Fenômenos Biomecânicos , Cadáver , Feminino , Fraturas Ósseas/fisiopatologia , Humanos , Masculino , Ossos Pélvicos/fisiopatologia , Pressão
16.
J Orthop Trauma ; 18(6): 361-8, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15213501

RESUMO

OBJECTIVES: To establish a laboratory model of implant cutout, which can evaluate the effect of implant design on cutout resistance in a clinically realistic "worst case" scenario. SETTING: Orthopaedic biomechanics laboratory. DESIGN: Implant cutout was simulated in an unstable pertrochanteric fracture model, which accounted for dynamic loading, osteoporotic bone, and a defined implant offset. For model characterization, lag screw cutout was simulated in human cadaveric specimens and in polyurethane foam surrogates. Subsequently, foam surrogates were used to determine differences in cutout resistance between 2 common lag screws (dynamic hip screw, Gamma) and 2 novel blade-type implant designs (dynamic helical hip system, trochanteric fixation nail). MAIN OUTCOME MEASURES: Implant migration was continuously recorded with a spatial motion tracking system as a function of the applied loading cycles. In addition, the total number of loading cycles to cutout failure was determined for specific load amplitudes. RESULTS: Implant migration in polyurethane surrogates closely correlated with that in cadaveric specimens, but yielded higher reproducibility and consistent cutout failure. The cutout model was able to delineate significant differences in cutout resistance between specific implant designs. At any of 4 load amplitudes (0.8 kN, 1.0 kN, 1.2 kN, 1.4 kN) dynamic hip screw lag screws failed earliest. The gamma nail lag screw could sustain significantly more loading cycles than the dynamic hip screw. Of all implants, trochanteric fixation nail implants demonstrated the highest cutout resistance. CONCLUSIONS: Implant design can significantly affect the fixation strength and cutout resistance of implants for pertrochanteric fracture fixation. The novel cutout model can predict differences in cutout resistance between distinct implant designs.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Quadril/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Fraturas do Quadril/cirurgia , Humanos , Masculino , Modelos Biológicos , Suporte de Carga
17.
J Orthop Trauma ; 28(4): 181-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24231583

RESUMO

OBJECTIVES: Document fixation and healing of distal femur fractures stabilized by plate osteosynthesis using far cortical locking (FCL) screws. DESIGN: Prospective and observational. SETTING: Two level 1 and 1 level 2 trauma centers. PATIENTS: Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33A, 33C). INTERVENTION: Fractures were stabilized by plate osteosynthesis with MotionLoc FCL screws without supplemental bone graft or bone morphogenic proteins. Patients were followed up for a minimum of 1 year with functional and radiographic assessments obtained at postoperative weeks 6, 12, and 24 and computed tomography scans at week 12. If union was not confirmed within 1 year, follow-up was continued until union or revision surgery. MAIN OUTCOME MEASURES: The primary end point was fracture union in the absence of complications and secondary interventions. Fracture healing was defined by resolution of pain at the fracture site and cortical bridging on biplanar radiographs. Complications were defined by fixation failure, loss of reduction, implant breakage, infection, nonunion, and need for revision. RESULTS: Thirty-one fractures were available for follow-up. None of the 125 FCL screws used for diaphyseal fixation broke or lost fixation. One of the 31 fractures displaced into varus (ΔVarus = 5.8 degrees). Thirty of the 31 fractures healed within 15.6 ± 6.2 weeks. At an average follow-up of 17 ± 4 months, there were 2 revisions: one to correct a malrotation at day 5 and one to treat a nonunion at 6 months. CONCLUSIONS: Absence of implant and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Adulto Jovem
18.
Injury ; 44(2): 232-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22910817

RESUMO

BACKGROUND: Surgical stabilization of flail chest injury with generic osteosynthesis implants remains challenging. A novel implant system comprising anatomic rib plates and intramedullary splints may improve surgical stabilization of flail chest injuries. This observational study evaluated our early clinical experience with this novel implant system to document if it can simplify the surgical procedure while providing reliable stabilization. METHODS: Twenty consecutive patients that underwent stabilization of flail chest injury with anatomic plates and intramedullary splints were prospectively enrolled at two Level I trauma centres. Data collection included patient demographics, injury characterization, surgical procedure details and post-operative recovery. Follow-up was performed at three and six months to assess pulmonary function, durability of implants and fixation and patient health. RESULTS: Patients had an Injury Severity Score of 28±10, a chest Abbreviated Injury Score of 4.2±0.4 and 8.5±2.9 fractured ribs. Surgical stabilization was achieved on average with five plates and one splint. Intra-operative contouring was required in 14% of plates. Post-operative duration of ventilation was 6.4±8.6 days. Total hospitalization was 15±10 days. At three months, patients had regained 84% of their expected forced vital capacity (%FVC). At six months, 7 of 15 patients that completed follow-up had returned to work. There was no mortality. Among the 91 rib plates, 15 splints and 605 screws in this study there was no hardware failure and no loss of initial fixation. There was one incidence of wound infection. Implants were removed in one patient after fractures had healed. CONCLUSIONS: Anatomic plates eliminated the need for extensive intraoperative plate contouring. Intramedullary rib splints provided a less-invasive fixation alternative for single, non-comminuted fractures. These early clinical results indicate that the novel implant system provides reliable fixation and accommodates the wide range of fractures encountered in flail chest injury.


Assuntos
Placas Ósseas , Tórax Fundido/cirurgia , Fixação Intramedular de Fraturas/métodos , Fraturas das Costelas/cirurgia , Adulto , Idoso , Materiais Biocompatíveis/uso terapêutico , Feminino , Tórax Fundido/diagnóstico por imagem , Tórax Fundido/fisiopatologia , Seguimentos , Humanos , Escala de Gravidade do Ferimento , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Fraturas das Costelas/fisiopatologia , Centros de Traumatologia , Resultado do Tratamento
19.
Accid Anal Prev ; 59: 109-17, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23770518

RESUMO

Angular acceleration of the head is a known cause of traumatic brain injury (TBI), but contemporary bicycle helmets lack dedicated mechanisms to mitigate angular acceleration. A novel Angular Impact Mitigation (AIM) system for bicycle helmets has been developed that employs an elastically suspended aluminum honeycomb liner to absorb linear acceleration in normal impacts as well as angular acceleration in oblique impacts. This study tested bicycle helmets with and without AIM technology to comparatively assess impact mitigation. Normal impact tests were performed to measure linear head acceleration. Oblique impact tests were performed to measure angular head acceleration and neck loading. Furthermore, acceleration histories of oblique impacts were analyzed in a computational head model to predict the resulting risk of TBI in the form of concussion and diffuse axonal injury (DAI). Compared to standard helmets, AIM helmets resulted in a 14% reduction in peak linear acceleration (p<0.001), a 34% reduction in peak angular acceleration (p<0.001), and a 22-32% reduction in neck loading (p<0.001). Computational results predicted that AIM helmets reduced the risk of concussion and DAI by 27% and 44%, respectively. In conclusion, these results demonstrated that AIM technology could effectively improve impact mitigation compared to a contemporary expanded polystyrene-based bicycle helmet, and may enhance prevention of bicycle-related TBI. Further research is required.


Assuntos
Aceleração , Acidentes de Trânsito , Ciclismo/lesões , Concussão Encefálica/prevenção & controle , Lesão Axonal Difusa/prevenção & controle , Dispositivos de Proteção da Cabeça/normas , Ciclismo/fisiologia , Fenômenos Biomecânicos , Lesões Encefálicas/prevenção & controle , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Manequins , Modelos Biológicos
20.
J Orthop Trauma ; 25 Suppl 1: S29-34, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21248557

RESUMO

The high stiffness of periarticular locked plating constructs can suppress callus formation and fracture healing. Replacing standard locking screws with far cortical locking (FCL) screws can decrease construct stiffness and can improve fracture healing in diaphyseal plating constructs. However, FCL function has not been tested in conjunction with periarticular plating constructs in which FCL screws are confined to the diaphyseal segment. This biomechanical study evaluated if diaphyseal fixation of a periarticular locking plate with FCL screws reduces construct stiffness and induces parallel interfragmentary motion without decreasing construct strength. Periarticular locking plates were applied to stabilize distal femur fractures in 22 paired femurs using either a standard locked plating approach (LP group) or FCL for diaphyseal fixation (FCL group) using MotionLoc screws (Zimmer, Warsaw, IN). Each specimen was evaluated under quasiphysiological loading to assess construct stiffness, construct durability under dynamic loading, and residual strength after dynamic loading. FCL constructs had an 81% lower initial stiffness than LP constructs. They induced nearly five times more interfragmentary motion than LP constructs under one body weight loading (P < 0.001). FCL constructs generated parallel interfragmentary motion, whereas LP constructs exhibited 48% less motion at the near cortex than at the far cortex (P = 0.002). Seven LP constructs and eight FCL constructs survived 100,000 loading cycles. The residual strength of surviving constructs was 4.9 ± 1.6 kN (LP group) and 5.3 ± 1.1 kN (FCL group, P = 0.73). In summary, FCL screws reduce stiffness, generate parallel interfragmentary motion, and retain the strength of a periarticular locked plating construct. Therefore, FCL fixation may be advisable for stiffness reduction of periarticular plating constructs to promote fracture healing by callus formation.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Idoso , Fenômenos Biomecânicos , Cadáver , Desenho de Equipamento , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA